PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microchip Analytical Procedures”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

A novel high-throughput automated chip-based nanoelectrospray tandem mass spectrometric method for PAMPA sample analysis.

Parallel artificial membrane permeability assay (PAMPA) has recently gained popularity as a novel, high-throughput assay capable of rapidly screening compounds for their permeability characteristics in early drug discovery. The analytical techniques typically used for PAMPA sample analysis are HPLC-UV, LC/MS or more recently UV-plate reader. The LC techniques, though sturdy and accurate, are often labor and time intensive and are not ideal for high-throughput. On the other hand, UV-plate reader technique is amenable to high-throughput but is not sensitive enough to detect the lower concentrations that are often encountered in early drug discovery work. This article investigates a novel analytical method, a chip-based automated nanoelectrospray mass spectrometric method for its ability to rapidly analyze PAMPA permeability samples. The utility and advantages of this novel analytical method is demonstrated by comparing PAMPA permeability values obtained from nanoelectrospray to those from conventional analytical methods. Ten marketed drugs having a broad range of structural space, physico-chemical properties and extent of intestinal absorption were selected as test compounds for this investigation. PAMPA permeability and recovery experiments were conducted with model compounds followed by analysis by UV-plate reader, UV-HPLC as well as the automated nanoelectrospray technique (nanoESI-MS/MS). There was a very good correlation (r(2) > 0.9) between the results obtained using nanoelectrospray and the other analytical techniques tested. Moreover, the nanoelectrospray approach presented several advantages over the standard techniques such as higher sensitivity and ability to detect individual compounds in cassette studies, making it an attractive high-throughput analytical technique. Thus, it has been demonstrated that nanoelectrospray analysis provides a highly efficient and accurate analytical methodology to analyze PAMPA samples generated in early drug discovery.

Automation↗

Magnetoresistive-based biosensors and biochips.

Over the past five years, magnetoelectronics has emerged as a promising new platform technology for biosensor and biochip development. The techniques are based on the detection of the magnetic fringe field of a magnetically labeled biomolecule interacting with a complementary biomolecule bound to a magnetic-field sensor. Magnetoresistive-based sensors, conventionally used as read heads in hard disk drives, have been used in combination with biologically functionalized magnetic labels to demonstrate the detection of molecular recognition. Real-world bio-applications are now being investigated, enabling tailored device design, based on sensor and label characteristics. This detection platform provides a robust, inexpensive sensing technique with high sensitivity and considerable scope for quantitative signal data, enabling magnetoresistive biochips to meet specific diagnostic needs that are not met by existing technologies.

Biosensing Techniques↗

Environmental microbiology-on-a-chip and its future impacts.

Rapid advances in microfabrication, DNA and protein microarray and microfluidic technologies have enabled the development of fully-integrated, miniaturized systems. These so called 'laboratory-on-a-chip' (LOC) devices perform sample preparation (i.e. concentration, separation and purification) together with biochemical reactions and detection steps in a simple and automated manner. We believe LOC technology for environmental microbiology studies will have immediate impacts on microbial monitoring by achieving detection and identification within minutes at the single-cell level, and on microbial ecology by deepening the understanding of microbial community structure and diversity and correlating these with niche-specific functions within a micro space. In the long run, significant impacts are anticipated on environmental metagenomics and proteomics.

Environmental Microbiology↗

Active pixel sensor array as a detector for electron microscopy.

A new high-resolution recording device for transmission electron microscopy (TEM) is urgently needed. Neither film nor CCD cameras are systems that allow for efficient 3-D high-resolution particle reconstruction. We tested an active pixel sensor (APS) array as a replacement device at 200, 300, and 400 keV using a JEOL JEM-2000 FX II and a JEM-4000 EX electron microscope. For this experiment, we used an APS prototype with an area of 64 x 64 pixels of 20 microm x 20 microm pixel pitch. Single-electron events were measured by using very low beam intensity. The histogram of the incident electron energy deposited in the sensor shows a Landau distribution at low energies, as well as unexpected events at higher absorbed energies. After careful study, we concluded that backscattering in the silicon substrate and re-entering the sensitive epitaxial layer a second time with much lower speed caused the unexpected events. Exhaustive simulation experiments confirmed the existence of these back-scattered electrons. For the APS to be usable, the back-scattered electron events must be eliminated, perhaps by thinning the substrate to less than 30 microm. By using experimental data taken with an APS chip with a standard silicon substrate (300 microm) and adjusting the results to take into account the effect of a thinned silicon substrate (30 microm), we found an estimate of the signal-to-noise ratio for a back-thinned detector in the energy range of 200-400 keV was about 10:1 and an estimate for the spatial resolution was about 10 microm.

Cryoelectron Microscopy↗

Microchip laser-induced fluorescence detection of proteins at submicrogram per milliliter levels mediated by dynamic labeling under pseudonative conditions.

We have previously demonstrated on-column dynamic labeling of protein-SDS complexes on capillaries and microchips for laser-induced fluorescence (LIF) detection using both a commercially available fluor and a protein separation buffer. Upon binding to hydrophobic moieties (of the analyte or separation buffer), the fluor undergoes a conformational change allowing fluorescence detection at 590 nm following excitation with 488-nm light. Our original work showed on-chip limits of detection (LOD) comparable with those using UV detection (1 x 10(-5) M) on capillaries-falling significantly short of the detection limits expected for LIF. This was largely a function of the physicochemical characteristics of the separation buffer components, which provided significant background fluorescence. Having defined the contributing factors involved, a new separation buffer was produced which reduced the background fluorescence and, consequently, increased the available dye for binding to protein-SDS complexes, improving the sensitivity in both capillaries and microchips by at least 2 orders of magnitude. The outcome is a rapid, sensitive method for protein sizing and quantitation applicable to both capillary and microchip separations with a LOD of 500 ng/mL for bovine serum albumin. Interestingly, sensitivity on microdevices was improved by inclusion of the dye in the sample matrix, while addition of dye to samples in conventional CE resulted in a drastic reduction in sensitivity and resolution. This can be explained by the differences in the injection schemes used in the two systems. The linear range for protein quantitation covered at least 2 orders of magnitude in microchip applications. On-chip analysis of human sera allowed abnormalities, specifically the presence of elevated levels of gamma-globulins, to be determined.

Blood Proteins↗

Microchip dialysis of proteins using in situ photopatterned nanoporous polymer membranes.

Chip-level integration of microdialysis membranes is described using a novel method for in situ photopatterning of porous polymer features. Rapid and inexpensive fabrication of nanoporous microdialysis membranes in microchips is achieved using a phase separation polymerization technique with a shaped UV laser beam. By controlling the phase separation process, the molecular weight cutoffs of the membranes can be engineered for different applications. Counterflow dialysis is used to demonstrate extraction of low molecular weight analytes from a sample stream, using two different molecular weight cutoff (MWCO) membranes; the first one with MWCO below 5700 for desalting protein samples, and the second one with a higher MWCO for size-based fractionation of proteins. Modeling based on a simple control volume analysis on the microdialysis system is consistent with measured concentration profiles, indicating both that membrane properties are uniform, well-defined, and reproducible and that diffusion of subcutoff analytes through the membrane is rapid.

Dialysis↗

Fully automated chip-based mass spectrometry for complex carbohydrate system analysis.

Carbohydrates represent a major class of biopolymers, which occur in nature either as oligosaccharides or glycoconjugates, in which the sugar moiety is linked to proteins or lipids. The significance of mass spectrometry for highly sensitive analysis of complex carbohydrates increased after the introduction of the electrospray ionization and matrix assisted laser desorption/ionization methods and the possibility of tandem MS for sequencing of single molecular species in complex mixtures. Rapid and sensitive characterization of carbohydrates in biological systems by automated nanoscale liquid delivery and chip-based electrospray interface techniques have not been developed so far. In this contribution, the implementation and optimization of a fully automated chip-based nanoelectrospray assembly (NanoMate system), operating in the negative ion mode, in combination with QTOF-tandem MS for mapping/sequencing and computer-assisted structure assignment for carbohydrate components in complex mixtures is presented.

Automation↗

Surface-modified poly(methyl methacrylate) capillary electrophoresis microchips for protein and peptide analysis.

Polymeric materials have emerged as appealing alternatives to conventional inorganic substrates for the fabrication of microscale analytical systems; however, native polymeric surfaces typically require covalent modification to ensure optimum biocompatibility. 2-Bromoisobutyryl bromide was immobilized on poly(methyl methacrylate) (PMMA) substrates activated using an oxygen plasma. Atom-transfer radical polymerization was then performed to graft poly(ethylene glycol) (PEG) on the PMMA surface. PMMA microcapillary electrophoresis (muCE) devices made with the covalently modified surfaces exhibited substantially reduced electroosmotic flow and nonspecific adsorption of proteins on microchannel surfaces. Experiments using fluorescein isothiocyanate-conjugated bovine serum albumin indicated that both column efficiency and migration time reproducibility were 1 order of magnitude better with derivatized compared to untreated PMMA muCE chips. Fast, reproducible, and efficient separations of proteins and peptides were demonstrated using the PEG-grafted PMMA muCE chips. All analyses were completed in less than 60 s, and separation efficiencies as high as 5.2 x10(4) plates for a 3.5-cm-long separation channel were obtained. These results demonstrate the general applicability of surface-grafted PMMA microdevices for a broad range of protein analyses.

Animals↗

Development of a micro total analysis system incorporating chemiluminescence detection and application to detection of cancer markers.

We developed a micro total analysis system (mu-TAS) incorporating chemiluminescence detection, in which the chemiluminescence reaction of isoluminol isothiocyanato (ILITC) (as a chemiluminescence reagent for labeling)-microperoxidase (as a catalyst)-hydrogen peroxide (as an oxidant) was adopted. The analysis system performed the following three processes on a microchip: immune reaction for high selectivity, electrophoresis for formation and transportation of the sample plug, and chemiluminescence detection for high sensitivity. The three processes were compactly integrated onto the microchip to give the mu-TAS. The microchip contained two microchannels that crossed at an intersection, while the ends of the microchannels accessed four reservoirs. As the first process, the immune reaction was performed using an antibody-immobilized glass bead. The glass bead was placed in one of the reservoirs along with antigen (analyte) and a known amount of ILITC-labeled antigen to set up a competitive immune reaction. For electrophoresis, as the second process, the reactant after the immune reaction was fed electrophoretically into the intersection resulting in a sample plug. The sample plug was then moved into another reservoir containing hydrogen peroxide solution. At this point, chemiluminescence detection was performed as the third process: the labeled antigen mixed with the hydrogen peroxide and the catalyst included in the migration buffer to produce chemiluminescence. Chemiluminescence was detected by a photomultiplier tube located under the reservoir. The mu-TAS described here was capable of determining, with high selectivity and sensitivity, human serum albumin or immunosuppressive acidic protein as a cancer marker in human serum.

Biomarkers, Tumor↗

Development of a microchip-based bioassay system using cultured cells.

We developed a novel bioassay system using a glass microchip and cultured cells. A microchamber for cell culture and microchannels for reactions and detection were fabricated on a Pyrex glass substrate by photolithography and wet etching techniques. Cell culture, chemical and enzymatic reactions, and detection were integrated into the microchip. To keep different temperatures locally in three areas of the microchip, we designed and fabricated a temperature control device. Nitric oxide released from macrophage-like cells stimulated by lipopolysaccharide was successfully monitored with the microchip, the temperature control device, and a thermal lens microscope. The total assay time was reduced from 24 to 4 h, and detection limit of NO was improved from 1 x 10(-6) to 7 x 10(-8) M compared with conventional methods. Moreover, the system could monitor a time course of the release, which is difficult to measure by conventional batch methods. We conclude that this system is promising for a rapid bioassay system with very small consumption of cells.

Animals↗

Compact detector for proteins based on two-photon excitation of native fluorescence.

A compact, inexpensive detector for proteins has been constructed based on two-photon excitation of fluorescence from phenylalanine, tyrosine, and tryptophan. The fluorescence was excited by a solid-state microchip laser operating at 532 nm. Detection limits for phenylalanine, tyrosine, and tryptophan were 62 microM, 2.0 microM, and 470 nM, respectively, in a volume of 3 fL. The detection limit for a test protein, bovine serum albumin, was 130 nM.

Animals↗

Microchip HPLC of peptides and proteins.

Rapid microchip reversed-phase HPLC of peptides and proteins at pressure gradients of 12 bar/cm (180 psi/cm) has been performed using a microdevice that integrates subnanoliter on-chip injection and separation with a miniaturized fluorescence detector. Proteins and peptides were separated on a C18 side-chain porous polymer monolith defined by contact lithography, and injection was achieved via a pressure-switchable fluoropolymer valve defined using projection lithography. Preliminary separations of peptide standards and protein mixtures were performed in 40-200 s, and switching between samples with no detectible sample carryover has been performed. The injections and separations were reproducible; the relative standard deviation (RSD) for retention time was 0.03%, and peak area RSD was 3.8%. Sample volumes ranging from 220 to 800 pL could be linearly metered by controlling the pressure injection pulse duration with conventional timing and valving. The current prototype system shows the potential for rapid and autonomous HPLC separations with varying modalities and the potential for direct connection to mass spectrometers at nanospray flow rates.

Chromatography, High Pressure Liquid↗

Extrinsic Fabry-Perot interferometry for noncontact temperature control of nanoliter-volume enzymatic reactions in glass microchips.

Optical fiber extrinsic Fabry-Perot interferometry (EFPI) was investigated as a noncontact temperature sensor and utilized for regulating the temperature of small-volume solutions in microchips. Interference pattern analysis determined the optical path lengths (OPL) associated with reflections from various surfaces on or in the microchip, in particular, from gold sputtered on the bottom of a microchannel. Since OPL is directly proportional to refractive index, which is dependent on solution temperature, the EFPI sensor was capable of noncontact monitoring of solution temperature simply from alterations in the measured path length. Calibration of the sensor against a thermocouple was performed while heating the microchip in a noncontact manner with an IR lamp. The combination of EFPI temperature sensor, IR-mediated heating, and air cooling allowed a fully noncontact system for small-volume temperature control in microchip structures, and its utility was illustrated by optimal digestion of DNA by a temperature-dependent restriction endonuclease in 320 nL. The functionality and simplicity of the microchip EFPI temperature sensor was enhanced by replacing the prebonding sputtered gold with a tunable, chemically plated semireflective silver coating created in situ after chip fabrication. This provided an 8-fold improvement in the lowest detectable temperature change (deltaT = 0.1 degrees C), facilitated primarily by enhanced reflection from both the bottom and top surfaces of the microchannel. This approach for controlling micro- and nanoscale reactions--with heating, cooling, and temperature control being carried out in a completely noncontact fashion--provides an accurate and sensitive method for executing chemical and biochemical reactions in microchips.

Biosensing Techniques↗

Electrokinetically synchronized polymerase chain reaction microchip fabricated in polycarbonate.

This paper presents a novel method for DNA thermal amplification using the polymerase chain reaction (PCR) in an electrokinetically driven synchronized continuous flow PCR (EDS-CF-PCR) configuration carried out in a microfabricated polycarbonate (PC) chip. The synchronized format allowed patterning a shorter length microchannel for the PCR compared to nonsynchronized continuous flow formats, permitting the use of smaller applied voltages when the flow is driven electrically and also allowed flexibility in selecting the cycle number without having to change the microchip architecture. A home-built temperature control system was developed to precisely configure three isothermal zones on the chip for denaturing (95 degrees C), annealing (55 degrees C), and extension (72 degrees C) within a single-loop channel. DNA templates were introduced into the PCR reactor, which was filled with the PCR cocktail, by electrokinetic injection. The PCR cocktail consisted of low salt concentrations (KCl) to reduce the current in the EDS-CF-PCR device during cycling. To control the EOF in the PC microchannel to minimize dilution effects as the DNA "plug" was shuttled through the temperature zones, Polybrene was used as a dynamic coating, which resulted in reversal of the EOF. The products generated from 15, 27, 35, and 40 EDS-CF-PCR amplification cycles were collected and analyzed using microchip electrophoresis with LIF detection for fragment sizing. The results showed that the EDS-CF-PCR format produced results similar to that of a conventional block thermal cycler with leveling effects observed for amplicon generation after approximately 25 cycles. To the best of our knowledge, this is the first report of electrokinetically driven synchronized PCR performed on chip.

DNA↗

Polymer nanochannels fabricated by thermomechanical deformation for single-molecule analysis.

A simple method for fabricating nanoscale channels based on thermomechanical deformation of rigid polymer substrates is demonstrated. Polycarbonate preforms containing microchannels with cross-sectional dimensions on the order of tens of micrometers are controllably deformed to produce submicrometer dimensions. The reduced channel dimensions are achieved by heating the preform while applying a uniaxial tensile force to reduce channel cross sections through the Poisson effect. Nanochannels with circular or elliptical cross sections are defined by varying the channel position and preform geometry prior to deformation. Arrays of parallel nanochannels with critical dimensions down to 400 nm are described. Using the fabrication method, a nanochannel network is fabricated for the detection of single protein molecules via confocal fluorescence microscopy. The chip includes a detection channel with cross-sectional dimensions approaching the confocal volume dimensions of the detection optics and a larger adjacent reference channel used to optimize focusing. Detection of fluorescently labeled bovine serum albumin at 15 and 150 nM concentrations is presented, demonstrating the ability to perform single-molecule fluorescence measurements in polycarbonate chips using visible wavelengths for excitation and detection.

Chemistry Techniques, Analytical↗