PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microscopy, Scanning Probe”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Surface ultrastructure of pit organ, spectacle, and non pit organ epidermis of infrared imaging boid snakes: A scanning probe and scanning electron microscopy study.

Boid snakes possess unique infrared imaging pit organs. The ultrastructure of the surfaces of these organs scatter or reflect electromagnetic radiation of specific wavelengths. Pit organ epidermal surfaces of boid snakes are covered with arrays of pore-like structures called micropits. In order to determine the dimensions of this complicated surface structure, we have performed the first ultrastructural analysis on snake epidermis by high-resolution microscopy techniques. Using scanning probe microscopy and scanning electron microscopy, we found that the epidermis of pit organ, maxillary non pit organ, spectacle, and ventral scales contain arrays of micropits. These scale surfaces also contain major surface features of overlapping plate-like structures. Pit organ micropits averaged 319 nm in diameter and 46 nm in depth and were spaced an average of 808 nm from each other. These micropits were significantly deeper, of greater diameter, and spaced at greater distances apart than those of the other scales. Plate structures of the pit organs had a mean distance between plates of 3.5 microm and a mean plate step height of 151 nm. These differences serve to strengthen the argument that arrays of micropit and plate surface structures function as spectral filters or anti-reflective coatings with respect to incident electromagnetic radiation.

Animals↗

Signatures of spin-charge separation in scanning probe microscopy.

We analyze the effect of an auxiliary scatterer, such as the potential of a scanning tip, on the conductance of an interacting one-dimensional electron system. We find that the differential conductance for tunneling into the end of a semi-infinite quantum wire reflects the separation of the elementary excitations into spin and charge modes. The separation is revealed as a specific pattern in the dependence of the conductance on bias and on the position of the scatterer.

Journal Article↗

Electrochemical deposition of molecular adsorbates for in situ scanning probe microscopy.

We have studied gold and graphite electrodes in an electrochemistry cell under various solutions using the scanning tunneling microscope (STM). The gold (111) surface yields quite reproducible images and cyclic voltammograms. In situ voltammograms show that, under certain conditions, nanomolar quantities of DNA fragments can suppress the adsorption of a buffer salt of millimolar concentration. When the DNA concentration is reduced below that required for a monolayer coverage, the salt adsorption is restored. We show images of bare gold, gold covered with an adsorbate produced by the buffer salt, and gold prepared with a concentration of DNA fragments close to that required for monolayer coverage added to the buffer. Under these conditions, the surface is found to be uniformly covered with a characteristic structure.

Adsorption↗

Potential-induced resonant tunneling through a redox metalloprotein investigated by electrochemical scanning probe microscopy.

The redox metalloprotein azurin self-chemisorbed onto Au(1 1 1) substrates has been investigated by electrochemically controlled scanning tunneling (STM) and scanning force/lateral force microscopy (SFM/LFM) and cyclic voltammetry (CV) in aqueous solution. The combined use of STM and SFM/LFM under electrochemical control in the negative side of the azurin redox midpoint (+116 mV vs. SCE) has delivered unique information on the nature of the STM images. While in STM the bright spots, believed to be associated with azurin molecules, are visible only for potential values higher than -125 mV, the concurrent electrochemical SFM results show adsorbed proteins over the whole potential range investigated (from -225 to +75 mV). Stepping the potential back and forth (between -25 and -125 mV) in STM imaging, it has been possible to make bright spots appearing and disappearing repeatedly, indicating that STM image formation arises possibly through resonant tunneling via the redox levels of azurin. These results represent the first clear evidence of potential-dependent tunneling in proteins adsorbed onto a conductive substrate.

Journal Article↗

Integrated confocal and scanning probe microscopy for biomedical research.

Atomic force microscopy (AFM) continues to be developed, not only in design, but also in application. The new focus of using AFM is changing from pure material to biomedical studies. More frequently, it is being used in combination with other optical imaging methods, such as confocal laser scanning microscopy (CLSM) and fluorescent imaging, to provide a more comprehensive understanding of biological systems. To date, AFM has been used increasingly as a precise micromanipulator, probing and altering the mechanobiological characteristics of living cells and tissues, in order to examine specific, receptor-ligand interactions, material properties, and cell behavior. In this review, we discuss the development of this new hybrid AFM, current research, and potential applications in diagnosis and the detection of disease.

Animals↗

Study of inhomogeneities in sources prepared for alpha-particle spectrometry using scanning probe microscopy.

For high-resolution alpha-particle spectrometry, sources of high quality must be prepared by methods giving the thinnest and most homogeneous deposit possible on a suitable support. Surface characteristics of several types of alpha-particle sources were studied using a scanning probe microscope. Major inhomogeneities were observed, which means that the materials and techniques used for thc preparation of sources must be improved.

Journal Article↗

Characterization of High Resolution Resists and Metal Shims by Scanning Probe Microscopy.

Technologies such as compact disc (CD) manufacturing, hologram embossing, and security printing rely on the reproduction of micro-patterns generated on surfaces by optical or electron-beam lithographic writing onto electron-beam or photoresists. The periodicity of such patterns varies from sub-micron to several microns, with depths up to 0.5 µm. The scanning probe microscope (SPM) is becoming a routine tool for analysis of these micro-patterns, to check on depths and lateral dimensions of features. Direct scanning of resist-covered plates is now possible, without damage, using resonant low-contact force SPM with etched silicon cantilevers. Metal shims produced from the master resist plates can also be scanned and checked for defects prior to production of embossed foils. The present article discusses examples of the use of a Digital Instruments 3100 microscope in analysis of production electron-beam lithography plates with a 0.5 µm resist thickness. We also examine features of nickel replicas ("father" and "mother" shims) produced by electroforming from the original plate. With SPM measurements of the development profile of a particular plate, corrections can be made to exposures and development times during production to correct errors. An example is given of such a feedback process.

Journal Article↗

Scanning probe microscopy characterization of single chains based on a one-dimensional oxalato-bridged manganese(II) complex with 4-aminotriazole.

The compound [Mn(mu-ox)(4atr)2]n (1) (ox = oxalato and 4atr = 4-amine-1,2,4-triazole) has been synthesized and characterized by FT-IR spectroscopy, thermal analysis, variable-temperature magnetic measurements, and X-ray single-crystal diffraction methods. The crystal structure of compound 1 consists of one-dimensional linear chains in which trans-[Mn(4atr)2]2+ units are sequentially bridged by centrosymmetric bis-bidentate oxalato ligands. Cryomagnetic measurements show an overall antiferromagnetic behavior of the compound. Isolated chains of this polymer have been obtained by sonication of 1 in ethanol or treatment of the polymer with NaOH and morphologically characterized on highly oriented pyrolitic graphite and mica surfaces by atomic force microscopy and scanning tunneling microscopy. The procedures employed to obtain single chains of this coordination polymer open a route for future nanotechnological applications of these types of materials.

Journal Article↗

Growth of cationic lipid toward bilayer lipid membrane by solution spreading: scanning probe microscopy study.

The growth of cationic lipid dioctadecyldimethylammonium bromide (DODAB) toward bilayer lipid membrane (BLM) by solution spreading on cleaved mica surface was studied by atomic force microscopy (AFM). Bilayer of DODAB was formed by exposing mica to a solution of DODAB in chloroform and subsequently immersing into potassium chloride solution for film developing. AFM studies showed that at the initial stage of the growth, the adsorbed molecules exhibited the small fractal-like aggregates. These aggregates grew up and expanded laterally into larger patches with time and experienced from monolayer to bilayer, finally a close-packed bilayer film (5.4+/-0.2 nm) was approached. AFM results of the film growth process indicated a growth mechanism of nucleation, growth and coalescence of dense submonolayer, it revealed the direct information about the film morphology and confirmed that solution spreading was an effective technique to prepare a cationic bilayer in a short time.

Aluminum Silicates↗

Immobilization strategies for biological scanning probe microscopy.

Biological atomic force microscopy (AFM) is now established as a method for studying the structure and function of biomolecular objects at the solid-liquid interface. Major progress in this field is linked to new developments in instrumentation, a better understanding of tip-sample interactions, and improved sample preparation techniques. In this review, the most common strategies for biomolecular immobilization with respect to biological AFM applications are summarized.

Microscopy, Atomic Force↗

Reduction of tip-sample contact using dielectrophoretic force scanning probe microscopy.

Dielectrophoretic force microscopy is shown to allow for facile noncontact imaging of systems in aqueous media. Electrokinetic tip-sample forces were predicted from topography measurements of an interface and compared with experimental images. Correlation function and power spectral density analyses indicated that image feedback was maintained without mechanical contact using moderate potentials (e.g., approximately 18 nm off the surface for a 7-Vpp, 100-kHz waveform). The applied dielectrophoretic force and the corresponding increase in effective tip radius were predictably adjusted by changing the peak potential.

Mathematics↗