[The execution of pharmaceutical analyses in the presence of polyethylene glycol derivatives. 1. Polyethylene glycol stearate in aqueous solution].
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Recently, in vitro studies have linked gamma radiation sterilization in air and subsequent oxidation to decreasing mechanical properties and rapid polyethylene wear. As a result of these studies, orthopaedic device manufacturers have developed alternate sterilization strategies designed to limit or to prevent oxidative degradation. We compared how the in vivo wear performance of conventional and highly-crystalline polyethylene acetabular liners was affected by two sterilization strategies (gas plasma sterilization and gamma radiation sterilization in vacuum-barrier packaging) as compared with gamma radiation sterilization in air. METHODS: Using multivariate linear regression analysis, we analyzed radiographic wear data on 385 total hip implants after a mean duration of follow-up of 6.2 years (range, four to eleven years). Two hundred and twenty-seven components had been sterilized with gamma radiation in air, seventy-seven had been sterilized with gas plasma, and eighty-one had been sterilized with gamma radiation in vacuum-barrier packaging. The liners had a mean shelf life of 0.65 +/- 0.85 year. Two hundred and fifty-two components were made from conventional ultra-high molecular weight polyethylene (Enduron), and 133 were made from highly crystalline ultra-high molecular weight polyethylene (Hylamer). RESULTS: In the conventional polyethylene group, the clinical wear performance of the components that had been sterilized with gamma radiation, either in air or in vacuum-barrier packaging, was superior to that of the nonirradiated components that had been sterilized with gas plasma. However, in the highly-crystalline polyethylene group, only the components that had been sterilized with radiation in vacuum-barrier packaging had a reduced rate of in vivo wear; the components that had been sterilized with gamma radiation in air had essentially the same high wear rate as did the liners that had been sterilized with gas plasma. CONCLUSIONS: The radiographic wear data on conventional polyethylene are consistent with the findings of laboratory studies that have demonstrated that radiation-induced cross-linking has a beneficial effect on polyethylene wear resistance. The conventional and highly-crystalline polyethylene liners in the present study, however, responded differently to gamma radiation sterilization in air despite the fact that the implants in both groups had very short shelf lives. This finding probably was due to the difference in the morphological structures of the two polyethylenes and the resulting greater susceptibility of highly-crystalline polyethylene to oxidative degradation. CLINICAL RELEVANCE: These findings provide clinical information that will help surgeons to make informed decisions concerning which components to implant. The data on Hylamer polyethylene liners provide insight into the expected performance of liners of this type that have already been implanted as well as potential insight into the performance of new polyethylenes. In particular, this information demonstrates that differences in the structure of polyethylene, as seen with the different highly cross-linked polyethylenes currently on the market, can affect clinical wear behavior. LEVEL OF EVIDENCE: Therapeutic study, Level III-2 (retrospective cohort study). See Instructions to Authors for a complete description of levels of evidence.
Permeability changes of polyethylene glycol 400 have been seen in patients with inflammatory bowel diseases. Because the colon can be involved in inflammatory bowel disease, the mechanisms, kinetics, and influence of intraluminal factors on polyethylene glycol 400 permeation of perfused colonic segments of rats were studied. The absorption rate of polyethylene glycol 400 was linearly related to its luminal concentration (r = 0.94), suggesting that passive diffusion is a significant mechanism involved in polyethylene glycol 400 absorption. Changing the perfusate pH from 6.0 to 7.5 did not affect water absorption or polyethylene glycol 400 permeation. Increasing luminal osmolarity significantly decreased water and polyethylene glycol 400 absorption (P less than 0.01). The relationship between polyethylene glycol 400 and water absorption at different luminal osmolarities was linear (r = 0.97). At luminal osmolarity of 0.3 osm/L, 14.3% of polyethylene glycol 400 absorption was mediated by passive diffusion and 85.7% was mediated by convection. The solvent drag reflection coefficient for polyethylene glycol 400 in the colon was 0.03. Taurocholic acid (10 mmol/L) and chenodeoxycholic acid (5 mmol/L) decreased polyethylene glycol 400 and water absorption (P less than 0.01). Addition of 1 micrograms/mL of 16,16-dimethyl prostaglandin E2, 2 mmol/L of dibutyryladenosine-3',5'-cyclic monophosphate, or 10 mmol/L of aminophylline significantly decreased water and polyethylene glycol 400 absorption (P less than 0.01). These studies demonstrate that polyethylene glycol 400 permeation of the colon is mediated by both passive diffusion and solvent drag. Convective absorption is the major mechanism of polyethylene glycol 400 permeation of the colon. Polyethylene glycol 400 permeation is modified by bile acids, prostaglandins, and cyclic nucleotides through changes in water flux.
BACKGROUND: Immunological responses to proteins that adhere to ultra-high molecular weight polyethylene have not, to our knowledge, been examined previously in patients who have aseptic loosening. In the current study, polyethylene components from forty-nine failed prostheses recovered during revision procedures were examined for the presence of antibodies that were bound to the polyethylene surface or that were reactive with other proteins that were bound to the polyethylene surface. METHODS: The polyethylene components consisted of thirty acetabular cups recovered during revision total hip arthroplasties and nineteen tibial components recovered during revision total knee arthroplasties. After extensive washing, bound proteins were extracted from the polyethylene components with use of 0.1-molar glycine-hydrogen chloride solution followed by four-molar guanidine hydrochloride solution. RESULTS: Sufficient protein for analysis was recovered from forty-two polyethylene components. Polyacrylamide gel electrophoresis demonstrated a minimum of one and a maximum of twelve protein bands, with molecular weights ranging from thirteen to 231 kilodaltons. Immunoblotting revealed the presence of type-I collagen in most (thirty-four) of the forty-two explants, whereas aggrecan proteoglycans were detected in eight samples. Immunoglobulin also was detected in most (thirty-three) extracts, whereas type-II collagen was consistently absent. The presence of autologous antibodies directed against polyethylene-bound proteins in sera drawn at the time of the revision was investigated. Antibodies that were reactive against the ultra-high molecular weight polyethylene-bound proteins were detected in twenty-six of the forty-two patients with use of the Western blot technique. The number of reactive bands ranged from one to six, and the strongest binding was directed against a 103-kilodalton protein. Assays for specificity revealed that these sera autologous antibodies were reactive against the type-I collagen that was present in the explant solutions. CONCLUSIONS: We hypothesize that immunoglobulin complexed with polyethylene may fix complement and that the complement cascade may in turn attract inflammatory cells to the polyethylene surface. Our data support the hypothesis that an immunological response to antigens bound to the polyethylene surface may contribute to aseptic loosening. CLINICAL RELEVANCE: Despite improvements in materials and designs of prostheses, aseptic loosening is the most common complication of total joint replacement, frequently leading to revision operations. We examined the immunological response to proteins that bind to ultra-high molecular weight polyethylene in patients who had aseptic loosening and discovered a high prevalence of antibodies to polyethylene-bound proteins. This immunological response may contribute to an inflammatory reaction in the periprosthetic tissue, ultimately leading to increased bone resorption around the prosthesis.
PURPOSE OF THE STUDY: The experience obtained during revision surgery and findings of polyethylene granulomas in surrounding tissues of replacement as well as marked differences in the viability of implants resulted in the study of polyethylene disease and its basic mechanisms producing the development of osteoaggressive granulomas. We investigated the morphology of particles and their number in tissues surrounding the implant. The aim of our study was to develop a method for the detection of polyethylene particles in tissues, to identify different types of wear and to assess factors that may influence the viability of joint arthroplasty in general. MATERIAL: Every revizion of joint arthroplasty performed during the last five years was evaluated in terms of the presence of polyethylene granules and the viability state of articular polyethylene inserts. A total of 55 samples were taken from tissues around loosened endoprostheses. The location of each sample was exactly determined. METHOD: A technique was developed to identify wear particles and to visualize them after all organic structures of a polyethylene granuloma were dissolved with nitrogenic acid. RESULTS: The viability of articular polyethylene implants showed extreme differences in relation to different periods of manufacture and probably also to different methods of sterilization. Articular inserts sterilized with formaldehyde (the method used at the beginning of arthroplasty in our country) showed the highest viability and the lowest wear. The polyethylene particles present in tissues surrounding the implant were characterized in terms of morphology and size. DISCUSSION: The comparison of literature data and our results has revealed that there are many unknown facts about the quality and structure of polyethylene. The method of sterilization also appears to play a role. Because the issue is complex, we were not able to identify all factors leading, in some cases, to an early and unexpected failure of the implant and we consider further investigation to be necessary. CONCLUSIONS: Polyethylene disease is an important factor limiting the viability of joint arthroplasty. It results from a complex interaction of polyethylene particles arising by wear with surrounding tissues. The particles, less than 0.5 micron in size, are phagocytized by macrophages and, by complex mechanism of expression of inflammation mediators, they result in the inhibition of osteogenesis and activation of osteoclastic processes. The previous methods of sterilization with formaldehyde vapors apparently reduced wear influenced the resistance of polyethylene to wear to a lesser degree. A method was developed to detect these particles and to characterize their morphology in the tissues of a polyethylene granuloma.
BACKGROUND: Cross-linked polyethylene was developed to reduce volumetric wear in prosthetic joints. Hip simulator studies have shown promising results with regard to wear reduction. This study evaluated the short-term in vivo wear of a moderately cross-linked polyethylene. METHODS: Linear head penetration, as an assessment of in vivo polyethylene wear, was measured in two groups of patients after total hip replacement. Twenty-four hips received a conventional polyethylene insert and thirty-four, a cross-linked polyethylene liner; both inserts were manufactured by the same company. Linear and volumetric wear rates were measured on radiographs with use of a validated computer-assisted technique and were adjusted for patient-related factors. Patient activity was assessed by a computerized two-dimensional accelerometer worn on the ankle. RESULTS: Patients with a conventional polyethylene insert showed a mean linear wear rate of 0.13 mm per year and a mean volumetric wear rate of 87.6 mm(3) per year. The group with a cross-linked polyethylene liner showed a mean linear wear rate of 0.02 mm per year and a mean volumetric wear rate of 17.0 mm(3) per year. Wear in the group with cross-linked polyethylene was 81% lower than that in the group with conventional polyethylene (p < 0.00001). Accounting for differences in patient activity, the adjusted wear rates per million cycles for a patient weight of 70 kg were 53 mm(3) per million cycles for conventional polyethylene and 15 mm(3) per million cycles for cross-linked polyethylene, a 72% reduction (p = 0.0002). No factor, other than the type of polyethylene, was found to influence the difference in wear rates between the two groups. CONCLUSIONS: The results of this study are promising. The in vivo wear reduction with this cross-linked polyethylene is consistent with the predictions of hip simulator studies.