PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polysomnography”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Transcutaneous and end-tidal carbon dioxide pressures should be measured during pediatric polysomnography.

Pediatric obstructive sleep apnea (OSAS) is characterized by partial airway obstruction, alveolar hypoventilation, and elevated arterial CO2 (PaCO2). Thus, a reliable, practical method of estimating CO2 is needed for pediatric polysomnography. Therefore, we measured both transcutaneous CO2 (PtcCO2) and end-tidal CO2 (PETCO2) in 15 pediatric polysomnographic evaluations. Sleep state, the highest PtcCO2, and the highest PETCO2 were recorded for 5,159 thirty-second epochs. Although PtcCO2 and PETCO2 were available for 78.5 and 73.0% of epochs, respectively, at least one estimator was available for 92% of the epochs. One infant who would not tolerate a nasal sampling catheter had no PETCO2 data. For 13 of 14 studies there was a relatively constant difference between PtcCO2 and PETCO2. The difference between PtcCO2 and PETCO2 was within 4 mm Hg in 63.9% of 3,072 epochs. Across 14 studies, mean PtcCO2 exceeded mean PETCO2 by 2.8 +/- 3.0 mm Hg, and it was within 4 mm Hg in 10 studies. In three subjects, PETCO2 was intermittently or consistently less than PtcCO2 because of tachypnea, increased physiologic dead space, or severe partial airway obstruction; in one subject PtcCO2 exceeded PETCO2 for undetermined reasons during one electrode application. The results of this study indicate that PtcCO2, as well as PETCO2, should be measured during pediatric polysomnography. By utilizing both PtcCO2 and PETCO2 there was a 70% reduction in the number of epochs that could not be assessed for hypoventilation. For an individual subject or electrode application there was a constant, and usually close, relationship, between PtcCO2 and PETCO2.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Gas Monitoring, Transcutaneous↗

Polysomnography in drug development.

Polysomnography in drug development is used to detect desirable and undesirable effects of drugs on normal and disturbed sleep. Although this method is essential for the approval of new hypnotic drugs, it is quite often neglected in the development of drugs that show unwanted side effects on normal sleep. In this review, the requirements for qualified polysomnography are described, the strong and weak points of the method are discussed, and its importance for the drug development process is pointed out.

Animals↗

Adults with ADHD and sleep complaints: a pilot study identifying sleep-disordered breathing using polysomnography and sleep quality assessment.

OBJECTIVE: ADHD and sleep-disordered breathing are both prevalent in adulthood. Because both conditions may be responsible for similar symptoms of cognitive impairment, the authors investigate whether their presentation may overlap in adults diagnosed with ADHD. METHOD: Data are collected from six adults with sleep complaints who were diagnosed with ADHD using rigorous clinical criteria. All participants undergo overnight polysomnography and complete questionnaires about sleep quality, circadian sleep pattern, and daytime fatigue. RESULTS: On standardized measures, all participants report poor sleep quality, two report daytime fatigue, and none report distinct deviation from normal sleep and wake cycle pattern. Polysomnography reveals evidence of sleep-disordered breathing and sleep fragmentation in all participants. CONCLUSION: Objective evidence of breathing-related sleep disorders can be found in some adults with carefully diagnosed ADHD who report sleep complaints. This report highlights the importance of identifying treatable sleep disorder comorbidity in adults with ADHD.

Adult↗

Simultaneous laboratory-based comparison of ResMed Autoset with polysomnography in the diagnosis of sleep apnoea/hypopnoea syndrome.

ResMed Autoset (AS) is a simplified diagnosis system for obstructive sleep apnoea/hypopnoea syndrome (OSAS) based on the respiratory flow/time relationship by pressure variation measured through simple nasal prongs. A multicentre prospective trial was used to compare AS and polysomnography (PSG) for diagnosing 95 patients, with suspected OSAS. Physicians gave a pretest probability of the patient having OSAS. The apnoea/hypopnoea index (AHI) was compared between the two methods of diagnosis for the whole population and for subgroups according to the pretest probability. Twenty-four patients had AHI < 15 events x h(-1) on PSG and 19 AHI 15-30, and 52 patients had AHI > or = 30. Correlation between AHI assessed by AS and PSG was r=0.87 for total sleep time (TST), p<0.0001. A Bland and Altman plot gave an agreement between the two methods of +/-40%. For a threshold of AHI > or = 15 events x h(-1) to diagnose OSAS, AS has a sensitivity of 92%, specificity of 79%, positive predictive value of 93% and negative predictive value of 76%. With a pretest probability > or = 80%, sensitivity and positive predictive value were 98 and 100% respectively. Of six false negative, four had a high pretest probability (> 80%) or Epworth score > or = 10. Using these parameters as a criterion for proceeding to PSG after a negative AS study would mean that two apnoeic patients (AHI 20 and 17 events x h(-1) by PSG) would escape detection. The Autoset is useful for the detection of obstructive sleep apnoea but with high pretest probability and a negative Autoset result polysomnography should be performed.

Adult↗

A polysomnography study of eszopiclone in elderly patients with insomnia.

OBJECTIVE: To evaluate the safety and efficacy of eszopiclone 2 mg in elderly patients (aged 64-86 years) with chronic insomnia. METHODS: This was a randomized, double-blind, placebo-controlled 2-week study. Patients meeting DSM-IV criteria for primary insomnia and screening polysomnography criteria (wakefulness after sleep onset [WASO] >or= 20 min and latency to persistent sleep >or= 20 min) were randomized to 2 weeks of nightly treatment with eszopiclone 2 mg (n = 136) or placebo (n = 128). Efficacy was assessed using polysomnography (Nights 1, 2, 13, and 14) and patient reports (Nights 1-14); safety was assessed using adverse events, clinical labs, physical examination, and vital signs. The mean of all efficacy results during the double-blind period was used for the efficacy analysis. RESULTS: Results indicated that eszopiclone was associated with significantly shorter sleep onset, less WASO, higher sleep efficiency, more total sleep time, and greater patient-reported quality and depth of sleep scores than placebo (p < 0.05 for all) with a trend in patient-reported morning sleepiness (p = 0.07). Other measures of daytime functioning (ability to function, daytime alertness, and sense of well-being) were not significantly different between the two treatment groups. Among patients who napped, eszopiclone patients reported fewer naps (p = 0.03) and less cumulative naptime (median: 98 min placebo, 70 min eszopiclone, p = 0.07). Unpleasant taste, dry mouth, somnolence, and dizziness were higher in the eszopiclone group (12.5%, 8.8%, 6.6%, and 6.6%, respectively) than in the placebo group (0%, 1.6%, 5.5%, and 1.6%, respectively). CONCLUSION: In this study, eszopiclone was well tolerated and produced significant improvements in both polysomnographic and patient-reported measures of sleep maintenance, sleep induction, and sleep duration in elderly patients with chronic primary insomnia.

Aged↗

Usefulness of polysomnography in epilepsy patients.

We reviewed the records of 63 adult epilepsy patients who underwent polysomnograms in our laboratory since 1985 to determine the indications for polysomnography and the results of testing. Reasons for referral included excessive daytime sleepiness, suspected obstructive sleep apnea (OSA), and characterization of nocturnal spells. The most common polysomnographic diagnosis was OSA, although we also found narcolepsy, insufficient sleep syndrome with possible idiopathic hypersomnolence, and previously unrecognized nocturnal seizures. We treated OSA with continuous positive airway pressure in 28 patients, 15 of whom were using the device at follow-up appointments. The majority of patients treated for OSA or other disorders reported an improvement in sleepiness or seizure control. Polysomnography, when indicated, is beneficial in epilepsy patients.

Adult↗

Sleep deprivation worsens obstructive sleep apnea. Comparison between diurnal and nocturnal polysomnography.

Daytime polysomnography (DPG) has been suggested for diagnosis of obstructive sleep apnea syndrome (OSAS), because it is less expensive than whole-night polysomnography investigation (NPG). To ensure sleep during day recordings, patients are often instructed to stay awake the night preceding DPG. This procedure has been validated against NPG, and also against apnea mattress recordings combined with ear oximetry (AMO). Twenty patients with OSAS symptoms were examined with NPG and simultaneous AMO and 2 to 3 weeks later with DPG 3 to 4 h in the morning after 1 nights sleep deprivation. Median apnea-hypopnea index (AHI) of DPG was 37 (95% confidence interval [CI], 19 to 44), significantly higher than median AHI of NPG (14; 95% CI, 12 to 27), whereas median nocturnal oxygen desaturation index (ODI) (11; 95% CI, 9 to 25) did not differ significantly from median AHI of NPG. Sensitivity values for DPG increased from 81 to 100% when the criteria AHI greater than 5, greater than 10, greater than 15, and greater than 20 were used, respectively. Specificity values also increased with the AHI used as cutoff point, from 50% (AHI>5) to 75% (AHI>20). In AMO, there were one false-negative case and four nonclassifiable borderline cases. If these types of simplified tests for OSAS are used for diagnosis, the risk of both false-negative and positive results (DPG) or nonclassifiable borderline cases (AMO) must be considered. Since there was a significant increase in AHI in DPG after sleep deprivation in comparison to conventional NPG, the former procedure should not be used for staging of the disease. These results also stress the importance of advice to OSAS patients concerning regular sleeping habits.

Adult↗

Portable computerized polysomnography in attended and unattended settings.

STUDY OBJECTIVE: We compared the validity of a new portable polysomnographic recorder against a laboratory-based polysomnographic system from the same manufacturer. DESIGN AND PATIENTS: Simultaneous, full polysomnographic recordings from the portable device (PSGP) and the laboratory-based system (PSGL) were obtained using separate sets of sensors on 20 patients referred for investigation of sleep apnea. SETTING: After initial optimization of signals, the portable device was left unattended in 10 of the patients (to simulate home studies), while in the other 10 the signals were reviewed on a laptop computer screen and adjustments to electrode or sensor placement made as needed during the studies. Recordings were manually scored by a technologist blinded to the origin of the data. MEASUREMENTS AND RESULTS: The quality of signals was comparable between the PSGP and PSGL studies, apart from a slight decrease in respiratory signal quality during PSGP studies that led to reduced confidence in respiratory event scoring. SaO2 signal loss was also greater in unattended PSGP. There was good agreement between PSGP and PSGL for sleep variables and the apnea-hypopnea index (r=0.99). The periodic limb movement index was slightly lower during unattended PSGP. Blinded physician assessment of the records led to a recommendation for repeat studies due to poor signal quality in one (10%) attended and one (10%) unattended portable recording. There was no significant discordance between PSGP and PSGL in the final diagnostic formulations. CONCLUSION: Portable polysomnography is a viable alternative to laboratory-based polysomnography and may be improved further by better sensor attachment.

Adult↗

Home unattended vs hospital telemonitored polysomnography in suspected obstructive sleep apnea syndrome: a randomized crossover trial.

STUDY OBJECTIVE: To compare home unattended polysomnography (H-PSG) with polysomnography performed in a local hospital and telemonitored by a sleep laboratory (T-PSG) in the diagnosis of obstructive sleep apnea syndrome (OSAS). DESIGN: Randomized crossover trial. PATIENTS: Ninety-nine patients with suspected OSAS who underwent H-PSG and T-PSG on 2 consecutive nights, according to a randomized order. MEASUREMENTS: H-PSG and T-PSG were compared in terms of (1) effectiveness, only recordings providing interpretable signals from at least one EEG, the electro-oculograph, the electromyograph, air flow, thoracic or abdominal movements, and arterial oxygen saturation for 180 min of sleep were considered to be effective; (2) patient preference assessed by a questionnaire; and (3) polysomnographic indexes and final interpretative results in patients for whom both recordings were legible. RESULTS: Recordings were considered to be ineffective in 11.2% of T-PSG (95% confidence interval [CI], 4.9 to 17.4%) and in 23.4% of H-PSG (95% CI, 19.12 to 27.68%). Thermistor problems were the main cause of failure of H-PSG. Forty-one percent of patients preferred H-PSG, and 55% preferred T-PSG. H-PSG and T-PSG did not differ in terms of sleep and respiratory indexes in the 65 patients in whom both recordings were legible. H-PSG and T-PSG were concordant in 58 of 65 patients using a 10-event-per-hour apnea-hypopnea index cutoff value for the diagnosis of OSAS. CONCLUSIONS: T-PSG is clearly superior to H-PSG from a technical point of view and tends to be preferred by patients. The site of recording (home vs hospital) has no influence on polysomnographic indexes.

Cross-Over Studies↗

Comparison of home oximetry monitoring with laboratory polysomnography in children.

STUDY OBJECTIVES: To measure the accuracy and reliability of a portable home oximetry monitor with an automated analysis for the diagnosis of obstructive sleep apnea (OSA) in children. DESIGN: Prospective cohort study. SETTING: Alberta Lung Association Sleep Center, Alberta Children's Hospital Sleep Clinic. STUDY SUBJECTS: Consecutive, otherwise healthy children, aged 4 to 18 years, presenting to the Pediatric Sleep Service at the Alberta Children's Hospital for assessment of possible OSA. INTERVENTIONS: All subjects underwent 2 nights of monitoring in the home with an oximetry-based portable monitor with an automatic internal scoring algorithm. A third night of monitoring was done simultaneously with computerized laboratory polysomnography according to American Thoracic Society guidelines. MEASUREMENTS AND RESULTS: Both test-retest reliability of the portable monitor-based desaturation index (DI) between 2 nights at home and between laboratory and home were high using the Bland and Altman analysis (mean agreement, 0.32 and 0.64; limits of agreement, - 8.00 to 8.64 and - 0.75 to 6.50, respectively). The polysomnographic apnea-hypopnea index (AHI) agreed poorly with the portable monitor DI (mean difference, 1.27; limits of agreement, - 12.02 to 15.02). The sensitivity and specificity of the monitor for the identification of moderate sleep apnea (polysomnography AHI > 5/h) were 67% and 60%, respectively. CONCLUSION: Portable monitoring based only on oximetry alone is not adequate for the identification of OSA in otherwise healthy children.

Adolescent↗

Evidence supporting routine polysomnography before bariatric surgery.

BACKGROUND: Obstructive sleep apnea (OSA) is common in morbidly obese patients, with a reported prevalence from 12 to 40%. Preoperative diagnosis of OSA is important for both perioperative airway management and the prevention of postoperative pulmonary complications. BMI has been reported to be an independent risk factor, and has been used recently in scoring systems to help predict OSA. Our hypothesis was that OSA is highly prevalent in patients presenting for bariatric surgery, and that BMI alone is not a good predictor of the presence or absence of sleep apnea. METHODS: A cross-sectional study was undertaken of the last 170 consecutive patients presenting for bariatric surgery in a single surgeon's practice. Clinical and demographic data were available from our prospective database, and polysomnography results were reviewed retrospectively. Sleep apnea was noted as present or absent, and graded from mild to severe. The patient population was stratified by BMI into severely obese (BMI 35-39.9), morbidly obese (BMI 40-49.9), super-obese (BMI 50-59.9), and super-super-obese (BMI >or= 60). RESULTS: OSA had been diagnosed before surgical consultation in 26 of the 170 patients (15.3%). Sleep studies were not available in 7 patients (4.1%). The remaining 137 patients (80.6%) had sleep data available, and 105 (76.6%) had sleep apnea (based on American Board of Sleep Medicine criteria). There was no correlation of sleep apnea with BMI. The overall prevalence of OSA in this cohort was 77% (131/170). CONCLUSIONS: In this large patient cohort, sleep apnea was prevalent (77%) independent of BMI, and most cases were not diagnosed before bariatric surgical consultation. These data support the use of routine screening polysomnography before bariatric surgery.

Adult↗

Kleine-Levin syndrome. Clinical course, polysomnography and multiple sleep latency test. Case report.

A case of Kleine-Levin syndrome, with chronic severe periodic hypersomnia is described in a 17-year-old female. The first episode started when she was 15 years old. The episodes were characterized by periodic hypersomnia accompanied by hyperphagia, lasting 5 days, and repeating at 28 to 60 day intervals. The severity of hypersomnia prevented her from attending school activities. Outside the hypersomnia periods, she was asymptomatic. EEG, brain computerized tomography and brain nuclear magnetic resonance were normal; all-night polysomnography, Multiple Sleep Latency Test (MSLT) and Epworth Sleepiness Scale (ESS) were within normal limits. During the period of hypersomnolence, polysomnography showed short sleep latency and short REM latency. MSLT mean sleep latency was 1.8 min; and REM period was present in one subtest; the ESS was markedly elevated.

Carbamazepine↗

[Diurnal sleep study for sleep related breathing disorders--the utility of nasendoscopic diurnal polysomnography using diazepam].

UNLABELLED: Twenty two patients with obstructive sleep apnea syndrome were examined by nocturnal polysomnography (n-PSG), and the obstructive sites in the upper airway were observed by nasendoscopic diurnal polysomnography using diazepam (n-d-PSGD). The types of apnea were divided into three groups according to the obstructive sites in the upper airway: soft palate apnea, tongue base apnea, and combined type apnea. Among the 22 patients, there were 17 soft palate apneas, 3 tongue base apneas and 2 combined type apneas. All patients underwent uvulopalatopharyngoplasty (UPPP). Preoperative values of AI, AR, DI and mean sleep SaO2 were 37.2, 24.5%, 31.4 and 92.5%, and the postoperative values were 10.4, 7.3%, 6.8 and 94.8%, respectively. Criteria were established to define UPPP responders, as follows: 50% or more reduction in AI and postoperative AI less than 20. The overall improvement rate was 81.0%. The improvement rates for soft palate apnea, combined type apnea and tongue base apnea were 93.8%, 50.0%, and 0%, respectively. In 15 of the 22 patients, measurements of mesopharyngeal and esophageal pressures were performed simultaneously with n-d-PSGD. In these 15 patients, 12 soft palate apneas, 2 combined type apneas and 3 tongue base apneas were observed with n-d-PSGD, while 7 soft palate apneas, 3 combined type apneas and 5 tongue base apneas were detected by measuring the pressures. The results of these two methods concurred in only nine of fifteen patients. It was suspected that the obstructive sites in the upper airway were identified by tissues with n-d-PSGD, but by region with the pressure measuring method. It was suggested that UPPP is the most suitable treatment for patients with soft palate type apnea, without pathologic obesity. IN CONCLUSION: n-d-PSGD is a useful method of evaluating respiratory status during sleep, can be performed in a few hours, and can simultaneously identify the obstructive site in the upper airway, so as to allow treatment planning.

Diazepam↗

[Validating a 7-channel ambulatory polygraph unit. 2: Simultaneous polysomnography].

PURPOSE: For some time, the ambulatory diagnosis of respiratory disturbances during sleep has included the use of seven-channel recording units. One of these systems is the POLY-MESAM unit (MAP, Germany). METHODS: The aim of the present study was to validate the POLY-MESAM system by simultaneously performing 12-channel polysomnography. Forty-nine patients (45 males and 4 females) with different severities of obstructive sleep-related breathing disorders were included. Obstructive sleep apnea was diagnosed, when an apnea-hypopnea index (AHI) > 15 was found by polysomnography. The sensitivity and specificity for POLY-MESAM were calculated on the basis of the polysomnographic AHI. RESULTS: The sensitivity of POLY-MESAM for detecting patients with an AHI > 15 was 86.4% and the specificity was 100%. CONCLUSIONS: The POLY-MESAM system was easy to use. The sensitivity and specificity for the MESAM4 unit were 92% and 97% respectively, which was similar to POLY-MESAM. Additionally, POLY-MESAM provided the possibility for distinguishing the different kinds of apneas. Thus, POLY-MESAM was considered to be a useful development of the previous MESAM4 unit. In some cases, use of the POLY-MESAM unit resulted in underestimation of the AHI. POLY-MESAM produced false-negative results in patients with mild to moderate OSA. This finding was reflected in the relatively poorer sensitivity of the method (86.4%). Cardiorespiratory sleep studies (as possible with POLY-MESAM) are best limited to patients for whom the diagnosis of OSA is highly probable or as a follow-up tool in selected circumstances.

Computer Systems↗

Rates of sensor loss in unattended home polysomnography: the influence of age, gender, obesity, and sleep-disordered breathing.

OBJECTIVES: To evaluate study failure and sensor loss in unattended home polysomnography and their relationship to age, gender, obesity, and severity of sleep-disordered breathing (SDB). DESIGN: A cross-sectional analysis of data gathered prospectively for the Sleep Heart Health Study (SHHS). SETTING: Unattended polysomnography was performed in participants' homes by the staff of the sites that are involved in SHHS. PARTICIPANTS: 6,802 individuals who met the inclusion criteria (age >40 years, no history of treatment of sleep apnea, no tracheostomy, no current home oxygen therapy) for SHHS. RESULTS: A total of 6802 participants had 7151 studies performed. 6161 of 6802 initial studies (90.6%) were acceptable. Obesity was associated with a decreased likelihood of a successful initial study. After one or more attempts, 6440 participants (94.7%) had studies that were judged as acceptable. The mean duration of scorable signals for specific channels ranged from 5.7 to 6.8 hours. The magnitudes of the effects of age, gender, BMI, and RDI on specific signal durations were not clinically significant. CONCLUSION: Unattended home PSG as performed for SHHS was usually successful. Participant characteristics had very weak associations with duration of scorable signal. This study suggests that unattended home PSG, when performed with proper protocols and quality controls, has reasonable success rates and signal quality for the evaluation of SDB in clinical and research settings.

Age Factors↗

The effect of in-laboratory polysomnography on sleep and objective daytime sleepiness.

MSLT guidelines recommend performing MSLTs following polysomnography (PSG) to document the preceding night's sleep. We tested the hypothesis that patients are objectively sleepier after in-laboratory full diagnostic PSG than after a sleep recording at home. Sixteen patients with the sleep apnea/hypopnea syndrome (SAHS; AHI 35+/-SD 28 per hour slept) were recruited into a randomized crossover study. To monitor sleep with minimal disruption at home, only sleep was recorded on 2 consecutive nights, the first for acclimatization. The laboratory limb followed standard PSG. Both study nights were followed next day by MSLT and MWT. There were no differences in MSLT (12.0 SD 5.1 home, 11.6+/-4.7 min laboratory; p=0.7), MWT (32.7+/-8.7, 31.6+/-9.3 min; p=0.6) or total sleep time (362+/-53, 343+/-51 min; p=0.15) between home and laboratory limbs. However, on the home night, fewer microarousals (31+/-14, 54+/-25/hr slept; p<0.0001) and less % wake (15+/-10, 24+/-11; p=0.006) were found. On the home study night, patients had greater % REM sleep, slow-wave sleep and sleep efficiency (all p<0.009). This study does not support the hypothesis that patients are sleepier after laboratory PSG compared to home study night. However, the improved sleep at home raises the question whether laboratory-based polysomnography is always required prior to MSLT/MWT testing or whether less obtrusive monitoring of sleep duration at home would sometimes suffice.

Adult↗

Patients with attention-deficit/hyperactivity disorder without observed apneic episodes in sleep or daytime sleepiness have normal sleep on polysomnography.

STUDY OBJECTIVE: There is continuing speculation about the relationship between attention-deficit/hyperactivity disorder (ADHD) and obstructive sleep apnea (OSA) or periodic limb movement disorder (PLMD)/restless legs syndrome. The objective was to determine if a significant portion of children with ADHD diagnosed using DSM-IV criteria have OSA or PLMD. SETTING: Sleep disorders centers in a private practice setting and a hospital setting. PARTICIPANTS: Children aged 6 to 14 years with ADHD were enrolled. Patients with snoring were not excluded. Although patients with snoring plus either observed apneic episodes in sleep or excessive daytime sleepiness were to be excluded, as were patients with restless legs at night, only 1 subject actually had to be excluded because of these criteria. MEASUREMENTS AND RESULTS: Forty children were evaluated with a polysomnogram. A respiratory disturbance index cut-off of more than 5 per hour of sleep was used to diagnose OSA, and a periodic limb movement (with arousal) index cut-off of 5 or more per hour of sleep was used to diagnose PLMD. The Attention-Deficit/Hyperactivity Disorder Rating Scale-IV-Parent Version: Investigator Administered and Scored was used to determine severity of inattentive, hyperactive, and total ADHD symptoms. Except for a somewhat longer rapid eye movement sleep latency and decreased percentage of rapid eye movement sleep, polysomnography was essentially normal. No patient had OSA or PLMD on polysomnography. CONCLUSIONS: OSA or PLMD is not a common underlying disorder or etiologic factor in patients who meet the criteria for ADHD. In the absence of symptoms suggesting a primary sleep disorder, such as snoring with observed apneic episodes in sleep or daytime sleepiness or restless legs, polysomnographic evaluation does not seem indicated in patients with ADHD.

Adolescent↗

[A case of benign childhood epilepsy with centrotemporal spike diagnosed by a seizure during polysomnography and clinical and EEG follow-up].

A healthy boy who had showed no evidence of cerebral lesions developed epileptic seizures resembling grand mal during nocturnal sleep at the age of 9 years and 2 months. Interictal EEG showed diffuse sharp waves that were maximal in the right centroparietal area and recurred at short intervals. Polysomnography for one night was performed when the patient was 9 years and 11 months old. The values of sleep variables (percentage of sleep period time for each sleep stage, sleep latency, REM density) were within normal limits. Interictal sharp waves appeared most frequently in the stages 3 and 4, and least in the stages REM and W. Partial seizure of the left face occurred with impaired consciousness in the stage 2 at around 5 a.m. On the ictal EEG, a low-voltage fast discharge was initiated in the right frontal area, followed by a diffuse rhythmic discharge of high voltage at 5-6 Hz, which was associated with a clinical seizure. The seizures completely ceased within one month after the polysomnography. Interictal sharp waves that migrated to the centrotemporal or midtemporal area disappeared at the age of 15 years and 9 months. The patient is now 19 years and 5 months of age. Although his interictal EEG and clinical seizures were atypical, we diagnose his disease as benign childhood epilepsy with centrotemporal spike based on the polysomnographic findings and the clinical and EEG follow-up.

Adolescent↗