PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polystyrenes”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

The effects of surface chemistry and adsorbed proteins on monocyte/macrophage adhesion to chemically modified polystyrene surfaces.

Monocytes and macrophages play critical roles in inflammatory responses to implanted biomaterials. Monocyte adhesion may lead to macrophage activation and the foreign body response. We report that surface chemistry, preadsorbed proteins, and adhesion time all play important roles during monocyte adhesion in vitro. The surface chemistry of tissue culture polystyrene (TCPS), polystyrene, Primaria, and ultra low attachment (ULA) used for adhesion studies was characterized by electron spectroscopy for chemical analysis. Fibrinogen adsorption measured by (125)I-labeled fibrinogen was the lowest on ULA, higher on TCPS, and the highest on polystyrene or Primaria. Monocyte adhesion on protein preadsorbed surfaces for 2 h or 1 day was measured with a lactate-dehydrogenase method. Monocyte adhesion decreased over time. The ability of preadsorbed proteins to modulate monocyte adhesion was surface dependent. Adhesion was the lowest on ULA, higher and similar on TCPS or polystyrene, and the highest on Primaria. Monocyte adhesion on plasma or fibrinogen adsorbed surfaces correlated positively and linearly to the amount of adsorbed fibrinogen. Preadsorbed fibronectin, immunoglobulin G, plasma, or serum also promoted adhesion compared with albumin preadsorbed or uncoated surfaces. Overall, biomaterial surface chemistry, the type and amount of adsorbed proteins, and adhesion time all affected monocyte adhesion in vitro.

Adsorption↗

Role of serum vitronectin and fibronectin in adhesion of fibroblasts following seeding onto tissue culture polystyrene.

The suitability of polymeric biomaterials as surfaces for the attachment and growth of cells has often been investigated in tissue culture. In this study the contribution that adsorption of serum fibronectin (Fn) or vitronectin (Vn) make to the attachment and spreading of fibroblast cells during the first 90 min following seeding was determined for two modified tissue culture polystyrenes, as model biomaterial surfaces. The amount of serum Vn and Fn which adsorbed onto tissue culture grade polystyrene (TCP) from different serum concentrations over the range of 0.1-30% (v/v) were determined and compared to attachment of cells of the BHK-21 and HT1080 fibroblast lines. There was no simple correlation between the amount of Fn or the amount of Vn adsorbed and cell attachment and spreading. The requirement for Fn or Vn for attachment and spreading of BHK-21 or HT1080 cells onto modified polystyrene (either TCP or to Primaria) during the first 90 min of cell culture was directly tested by selective removal of Fn or Vn from the serum prior to addition to the culture medium. Attachment and spreading of BHK-21 or HT1080 cells onto TCP or Primaria surfaces were reduced in a concentration-dependent manner when the cells were seeded in medium containing 2% (v/v) or higher concentrations of Vn-depleted serum. BHK-21 cells or HT1080 cells seeded in medium containing Fn-depleted serum (which contained Vn) attached and spread onto TCP or Primaria. Both BHK-21 cells and HT1080 cells failed to attach to TCP or Primaria when seeded in medium containing serum depleted of both Vn and Fn. The requirement for serum Vn or Fn for fibroblast attachment to TCP was also tested using cells of a human dermal fibroblast strain. The attachment of the dermal fibroblasts to TCP during the first 90 min of culture was not decreased by depletion of Vn from the 15% (v/v) serum, but there was a reduction in the proportion of the attached cells which had spread. Selective depletion of serum Fn did not have any effect on either cell attachment or spreading. Our results show that for fibroblast cells, particularly with cell lines such as BHK-21 or HT1080 but also with cell strains, the first binding of cells onto tissue culture polystyrene when plated in medium containing serum is a result of adsorption onto the surface of serum Vn. The adsorption of serum Vn onto the surface overcomes the effect of serum components which tend to decrease cell attachment.

Adsorption↗

Binding and orientation of fibronectin on polystyrene surfaces using immobilized bacterial adhesin-related peptides.

Fibronectin (FN) is known to bind to bacteria via high affinity receptors on bacterial surfaces known as adhesins. The binding of bacteria to FN is thought to have a key role in foreign device associated infections. For example, previous studies have indicated that Staphylococcus aureus adhesins bind to the 29 kDa NH(3) terminus end of FN, and thereby promote bacteria adherence to surfaces. Recently, the peptide sequences within the S. aureus adhesin molecule that are responsible for FN binding have been identified. Based on these observations, we hypothesize that functional FN can be bound and specifically oriented on polystyrene surfaces using bacterial adhesin-related (BRP-A) peptide. We further hypothesize that monoclonal antibodies that react with specific epitopes on the FN can be used to quantify both FN binding and orientation on these surfaces. Based on this hypothesis, we initiated a systematic investigation of the binding and orientation of FN on polystyrene surfaces using BRP-A peptide. To test this hypothesis, the binding and orientation of the FN to immobilized BRP-A was quantified using (125)I-FN, and monoclonal antibodies. (125)I-FN was used to quantitate FN binding to peptide-coated polystyrene surfaces. The orientation of bound FN was demonstrated by the use of monoclonal antibodies, which are reactive with the amine (N) or carboxyl (C) termini of the FN. The results of our studies demonstrated that when the BRP-A peptide was used to bind FN to surfaces that: 1. functional FN was bound to the peptide; 2. anti-C terminus antibodies bound to the peptide FN; and 3. only limited binding of anti-N terminus antibodies to peptide-bound FN occurred. We believe that the data that indicate an enhanced binding of anti-C antibodies reactive to anti-N antibodies are a result of the FN binding in an oriented manner with the N termini of FN bound tightly to the BRP-A on the polystyrene surface.

Adhesins, Bacterial↗

Rate and pattern of gastric emptying in humans using 99mTc-labeled triethylenetetraamine-polystyrene resin.

The preparation and application of a new radiopharmaceutical used in the investigation of the rate and pattern of gastric emptying by external scintigraphy are described. Triethylenetetraamine was bound covalently to cross-linked chloromethylated polystyrene. The triethylenetetraamine-polystyrene resin tenaciously and rapidly bound technetium 99m. The gastric emptying rate was evaluated in normal adult volunteers and patients by serially recording the gastric radioactivity after ingestion of a test meal mixed with 99mTc-labeled triethylenetetraamine-polystyrene resin. The data indicated that 99mTc-labeled triethylenetetraamine-polystyrene resin was an ideal agent for assessing the rate and pattern of gastric emptying in humans. The gastric emptying half-time (t 1/2 GE) in normal subjects ranged from 25 to 75 min.

Ethylenediamines↗

Comparative evaluation of four trityl-type amidomethyl polystyrene resins in Fmoc solid phase peptide synthesis.

Four trityl-type (i.e. non-substituted trityl-, o-Cl-trityl-, o-F-trityl- and p-CN-trityl-) amidomethyl polystyrene resins were evaluated comparatively, in terms of the stability of the trityl-ester bond in slightly acidic dichloromethane solutions, and the p-CN-trityl-amidomethyl polystyrene resin was found to be the most stable of them. The above resins were applied, in parallel with Wang benzyl-type resin, well known for its stability in mild acidic conditions, to the Fmoc solid phase synthesis of the 43-amino acid residue long bioactive peptide thymosin beta-4. Independent of their differences in acid sensitivity, the resins seemed to function equally well under the conditions used, since pure thymosin beta-4 was obtained with a final yield of approximately 30% from each resin. The trityl-type amidomethyl polystyrene resins were also applied, in parallel with the Wang resin, to the Fmoc solid phase synthesis of a bioactive peptide containing proline at its C-terminus, i.e. the N-terminal tetrapeptide of thymosin beta-4, AcSDKP. In this case, the best yield (87%) was obtained with the o-Cl-trityl-amidomethyl polystyrene resin, which may be the resin of choice, of those studied, for the Fmoc solid phase peptide synthesis.

Molecular Structure↗

Size-dependent proinflammatory effects of ultrafine polystyrene particles: a role for surface area and oxidative stress in the enhanced activity of ultrafines.

Studies into the effects of ultrafine particles in the lung have shown adverse effects considered to be due in part to the particle size. Air pollution particles (PM(10)) are associated with exacerbations of respiratory disease and deaths from cardiovascular causes in epidemiological studies and the ultrafine fraction of PM(10) has been hypothesized to play an important role. The aim of the present study was to investigate proinflammatory responses to various sizes of polystyrene particles as a simple model of particles of varying size including ultrafine. In the animal model, we demonstrated that there was a significantly greater neutrophil influx into the rat lung after instillation of 64-nm polystyrene particles compared with 202- and 535-nm particles and this was mirrored in other parameters of lung inflammation, such as increased protein and lactate dehydrogenase in bronchoalveolar lavage. When surface area instilled was plotted against inflammation, these two variables were directly proportional and the line passed through zero. This suggests that surface area drives inflammation in the short term and that ultrafine particles cause a greater inflammatory response because of the greater surface area they possess. In vitro, we measured the changes in intracellular calcium concentration in mono mac 6 cells in view of the potential role of calcium as a signaling molecule. Calcium changes after particle exposure may be important in leading to proinflammatory gene expression such as chemokines. We demonstrated that only ultrafine polystyrene particles induced a significant increase in cytosolic calcium ion concentration. Experiments using dichlorofluorescin diacetate demonstrated greater oxidant activity of the ultrafine particles, which may explain their activity in these assays. There were significant increases in IL-8 gene expression in A549 epithelial cells after treatment with the ultrafine particles but not particles of other sizes. These findings suggest that ultrafine particles composed of low-toxicity material such as polystyrene have proinflammatory activity as a consequence of their large surface area. This supports a role for such particles in the adverse health effects of PM(10).

Animals↗

The immunochemistry of sandwich-ELISAs. IV. The antigen capture capacity of antibody covalently attached to bromoacetyl surface-functionalized polystyrene.

The antigen capture capacity of antibodies covalently immobilized on injection-molded polystyrene beads was evaluated. Bromoacetyl groups on the bead surfaces rendered them reactive to protein nucleophilic groups. The bromoacetyl surface exhibited up to a ten-fold greater capacity for protein compared to unmodified polystyrene, with no detectable dissociation such as occurs with simple adsorption. Biotinylated anti-fluorescein was immobilized on this surface both through direct covalent attachment and indirectly via streptavidin, which was first covalently attached to the bead. Comparisons of the resulting biological activity, normalized to the amount of anti-fluorescein on the bead, were made between the attachment methods and simple passive adsorption. The presence of the streptavidin spacer on the bromoacetyl surfaces improved the antigen capture capacity of antifluorescein, for fluoresyl-albumin by 45% compared to direct covalent linkage of the antibody to modified polystyrene and by 160% relative to antibody adsorbed on unmodified polystyrene.

Acetates↗

Coating of proteins to polystyrene ELISA plates in the presence of detergents.

The influence of several detergents on protein coating of polystyrene plates has been investigated. At concentrations equal to or higher than their respective critical micelle concentration (CMC) all detergents prevent attachment of proteins to polystyrene. However, coating of proteins on polystyrene plates can be achieved in the presence of detergents at concentrations 10-100 times lower than their CMC values. There is a strong correlation between the CMC and the detergent concentration inhibiting protein binding to polystyrene by 50%. The rank correlation coefficient for the binding of thyroid plasma membrane antigens was 0.97 (P less than 0.01). The influence of a detergent on the efficiency of protein coating of plastic surfaces also depends to some extent on protein-detergent interactions. Attachment of small hydrophilic proteins such as human IgG is more strongly inhibited by detergents than is the coating of hydrophobic thyroid plasma membrane antigens or thyroglobulin. Some detergents do not interfere with protein attachment to plastics and permit subsequent ELISA assays for hydrophobic, detergent solubilized plasma membrane proteins.

Cell Membrane↗

Preparation of diazotized polystyrene latex and its use in agglutination assays.

The preparation of this immunological latex consisted of the following steps: the synthesis of polystyrene, polynitrostyrene, polyaminostyrene and polystyrene diazonium salt latex. The quantities of emulsifier and initiator used in the synthesis of the polystyrene latex were much larger than those used in the conventional method. Reduction of the polynitrostyrene latex involved adding latex dropwise to a large excess of 6% sodium hydrosulphite-2 N potassium hydroxide solution with sodium lauryl benzene sulphonate as an emulsifier. When the mixture was heated at 70 degrees C for 4 h, the emulsion of polyaminostyrene was diazotized. The polystyrene diazonium salt latex obtained was capable of combining with 20-40% by weight of antibody protein. The immunopolystyrene diazonium latex reagents showed a positive agglutination reaction of 78-91% when mixed with serum from patients with leptospirosis and two other infectious diseases. The test, which can be completed within 3 min has been used to assay over 1200 patient samples.

Agglutination Tests↗

Glycocalicin binding to von Willebrand factor adsorbed onto collagen-coated or polystyrene surfaces.

In order to analyze the interaction of platelets with von Willebrand factor (vWF) and collagen, we studied the binding of glycocalicin (GC) and formalin-fixed platelets to vWF adsorbed onto uncoated or collagen-coated polystyrene surfaces. These studies show that three-fold more vWF binds to collagen-coated polystyrene than to polystyrene coated with fibrin monomer or fibrinogen. At saturation, 37 +/- 2.9 ng vWF bound to the collagen-coated wells, compared to 12.8 +/- 5.4 ng, and 10.9 +/- 2.7 ng of vWF bound to wells coated with fibrin monomer and fibrinogen, respectively. GC also bound significantly more to collagen-coated wells than to wells coated with fibrinogen, and this binding was increased approximately two-fold (from 7 +/- 0.65 ng to 14 +/- 1.1 ng) in the presence of vWF adsorbed to the collagen-coated surface. Only 2 ng of GC was bound to 3000 ng of vWF when the latter was adsorbed directly onto a polystyrene surface. In contrast, GC binding to vWF adsorbed onto a collagen-coated surface was enhanced 600-fold with 7.0 ng of GC bound to 18 ng of immobilized vWF. Formalin-fixed platelets showed little binding to vWF adsorbed onto the microtiter wells. At saturation, 7 x 10(4) platelets bound to 3000 ng of vWF; a 6-fold increase in platelet binding was observed using collagen-coated wells and this binding was increased even further in the presence of vWF, resulting in 250-fold increase in platelet binding to vWF when the latter was adsorbed onto a collagen surface. These studies suggest that (1) GC is involved in platelet binding to collagen and this binding is increased by vWF; (2) GC binding to vWF is enhanced by the collagen-coated surface; (3) the adsorption of vWF onto a collagen surface may induce conformational changes in vWF that promote its interaction with GC or glycoprotein Ib.

Adsorption↗

Lead-polystyrene transition zone dosimetry in high-energy photon beams.

In order to study the dose enhancement under sheets of lead positioned directly on the skin of patients, parallel-plate ionization chamber measurements in high-energy photon beams (4-15 MV) were performed below a lead-polystyrene interface. The dose in the transition zone can be much higher or lower than in the situation with full buildup of polystyrene. The enhancement of ionization directly beneath the lead-polystyrene interface, compared to the ionization at a reference depth in polystyrene, increases with photon energy and field size. The field size dependence is due to an increase in relative contribution to the energy fluence of low-energy photons scattered in the phantom and for the 4 MV beam also to photons scattered in the head of the accelerator. By adding a thin (100 microns) plastic absorber against the lead, the low-energy and large-angle electrons, which give rise to the enhanced interface dose, can largely be removed. The data indicate that lead as bolus material should only be used with extreme caution.

Humans↗

Characterisation of electrospun polystyrene scaffolds for three-dimensional in vitro biological studies.

The purpose of this study was to produce a well-characterised electrospun polystyrene scaffold which could be used routinely for three-dimensional (3D) cell culture experimentation. A linear relationship (p<0.01) between three principal process variables (applied voltage, working distance and polymer concentration) and fibre diameter was reliably established enabling a mathematical model to be developed to standardise the electrospinning process. Surface chemistry and bulk architecture were manipulated to increase wetting and handling characteristics, respectively. X-ray photoelectron spectroscopy (XPS) confirmed the presence of oxygen-containing groups after argon plasma treatment, resulting in a similar surface chemistry to treated tissue culture plastic. The bulk architecture of the scaffolds was characterised by scanning electron microscopy (SEM) to assess the alignment of both random and aligned electrospun fibres, which were calculated to be 0.15 and 0.66, respectively. This compared to 0.51 for collagen fibres associated with native tissue. Tensile strength and strain of approximately of 0.15 MPa and 2.5%, respectively, allowed the scaffolds to be routinely handled for tissue culture purposes. The efficiency of attachment of smooth muscle cells to electrospun scaffolds was assessed using a modified 3-[4,5-dimethyl(thiazol-2yl)-3,5-diphery] tetrazolium bromide assay and cell morphology was assessed by phalloidin-FITC staining of F-actin. Argon plasma treatment of electrospun polystyrene scaffold resulted in significantly increased cell attachment (p<0.05). The alignment factors of the actin filaments were 0.19 and 0.74 for the random and aligned scaffold respectively, compared to 0.51 for the native tissue. The data suggests that electrospinning of polystyrene generates 3D scaffolds which complement polystyrene used in 2D cell culture systems.

Animals↗

Preparation of multilayered gold-silica-polystyrene core-shell particles by seeded polymerization.

A preparation method for multilayered gold-silica-polystyrene core-shell composite particles is proposed. The gold-silica core-shell particles of 192-nm-sized, synthesized by coating the 18-nm-sized gold particles with silica by a seeded growth technique, were used as cores for succeeding polystyrene coating. After surface modification of gold-silica composite particles by methacryloxypropyltrimethoxysilane (MPTMS), polymerizations of styrene (0.16-0.4 M) were conducted with 8 x 10(-3) M of potassium persulfate initiator in the presence of 1 x 10(-3) M of sodium p-styrenesulfonate anionic monomer. Multilayered core-shell gold-silica-polystyrene particles that contained a single core could be obtained. The coefficient of variation of size distribution (CV) of the composite particles was less than 7%, and polystyrene shell thickness was in a range of 193 to 281 nm.

Gold↗

Application of neutral hydrophobic hypercrosslinked polystyrene to the separation of inorganic anions by ion chromatography.

Neutral hydrophobic hypercrosslinked polystyrene was shown to exhibit anion-exchange properties in the pH range 2.6-4.3 that can be attributed to the presence of protonated carbonyls in the framework of the polymer. This resin does not contain any other heteroatoms, except oxygen, responsible for the occurrence of positive charge at the surface. The anion-exchange selectivity of MN-200 and monosized spherical hypercrosslinked polystyrene to inorganic anions with diluted perchloric, nitric and sulfuric acid solutions as eluent was studied and the selectivity was found to be different from that observed for the common anion-exchangers. The main features of hypercrosslinked polystyrene are weak retention of sulphate and comparatively strong retention of nitrite that can be useful in practical ion chromatography. The influence of column temperature on the retention was investigated. Calculated adsorption heats are in the range from -2 to 19 kJ/mol. The retention mechanism of inorganic anions on neutral hypercrosslinked polystyrene includes both ion-exchange and hydrophobic interactions.

Anions↗

Retention behaviour of polystyrene oligomers in reversed-phase liquid chromatography.

Reversed-phase liquid chromatography (RPLC) was employed to investigate the behaviour of low-molecular-mass polystyrene oligomers with three different end groups, n-butyl, sec-butyl, and tert.-butyl polystyrenes. Exothermodynamic retention studies on the polystyrene oligomers were carried out using a C18 stationary phase column and 100% methanol mobile phase over the temperature range 15 to 60 degrees C. The resulting van't Hoff plots were linear over the entire temperature range for all three end group polystyrenes. Enthalpy-entropy compensation (EEC) showed a linear compensation for the higher-order oligomers, but was non-linear for the lower-order oligomers, indicating a change in the mechanism of retention. Differences in the extent of retention for each of the three end groups were also apparent. The ramifications of these differences are discussed.

Chromatography, Liquid↗

Molecular mechanisms of improved adhesion and growth of an endothelial cell line cultured on polystyrene implanted with fluorine ions.

Endothelial cells derived from the bovine pulmonary artery (line CPAE, CCL 209, American Tissue Culture Collection, Rockville, MD, USA) were cultured on pristine or fluorine ion-irradiated polystyrene (5 x 10(12) or 5 x 10(14) F ions/cm2, 150 keV). At 24-h post-seeding interval, the number of cells which adhered to the ion-modified polystyrene was significantly higher than on the unmodified material (+20 and +58% in cultures with the polystyrene irradiated by lower and higher ion doses, respectively). On day 7, the populations cultured on the irradiated substrates grew to higher densities, exceeding the controls at the lower and higher ion doses by 69 and 180%, respectively. The cells on ion-implanted samples were also larger (+70-95% and +90-99% at the lower and higher ion doses, respectively) and contained more protein (+16% at both ion doses). As was shown by ELISA, the polystyrene irradiated by the higher ion dose enhanced the expression of a cytoskeletal protein, vimentin (+65%) and protein of focal adhesion plaques, talin (+15%). The content of integrin alpha5beta1 (VLA-5), receptor for fibronectin, was increased at both lower and higher ion doses (+22 and +57%). In contrast to this, the content of ICAM-1 and vinculin was similar in cells grown on both pristine and ion-irradiated growth substrates. Moreover, the expression of VCAM-1 and ELAM-1 was lower by 11-14% in both ion dose groups. The present study has shown that ion implantation of polymers improves the adhesion and growth of endothelial cells without elevating the expression of immunoglobulin and selectin types of adhesion molecules. This surface modification should promote colonization of an artificial vascular prosthesis by endothelial cells and make it less vulnerable by immune system cells of the recipient.

Animals↗

Selective surface adhesion of the toxic microalga Alexandrium minutum induced by contact with substituted polystyrene derivatives.

On the basis of observations that biospecific random copolymers (RACS) could induce phenotypic changes on contact with selected eukaryotic or prokaryotic cell lines, polystyrene derivatives of known compositions and obtained by random substitutions of sodium sulfonate and of sulfamides of aspartic acid dimethyl ester, phenylalanine and leucine, were placed in contact with swimming dinophytes of the PSP toxin producing species Alexandrium minutum and of the non-toxic species Heterocapsa triquetra. A. minutum cells exhibited higher adhesion for the random copolymer made up of polystyrene (29%), polystyrene aspartic acid dimethyl ester sulfamide (47%) and polystyrene sodium sulfonate (24%), than for samples of this series with different compositions. In contrast to this, A. minutum adhesion remained very low throughout the phenylalanine and leucine copolymer series. These results indicate that the cell-substrate adhesion phenomenon is dependent upon the final composition of the copolymer, i.e. that it is composition-specific. Taxonomic specificity was then demonstrated by presenting the PSAspOMe copolymer series with cells of the non toxic species H. triquetra (Peridinialia) related to A. minutum (Gonyaulacacea), and by observing no specific association, i.e. no signal above background levels at any composition. Specific ligand-cell adhesion is evidenced for the first time between biospecific RACS and phytoplankton, which may inspire a new generation of structures to be used in aquaculture as protective nets over shellfish clusters, or as selective filtering devices to assist in shellfish depuration from toxic microalgae.

Animals↗

Effect of sodium polystyrene sulfonate on lithium bioavailability.

STUDY OBJECTIVE: To examine the effect of a single dose of sodium polystyrene sulfonate and sorbitol on lithium absorption. DESIGN: Prospective, randomized, crossover. SETTING: University teaching hospital. TYPE OF PARTICIPANTS: Healthy volunteers. INTERVENTIONS: Subjects ingested 600 mg lithium carbonate on two occasions, with and without 30 g concomitant sodium polystyrene sulfonate. Blood samples were drawn up to 24 hours after ingestion and assayed for serum lithium concentration. MEASUREMENTS AND MAIN RESULTS: Compared with control, sodium polystyrene sulfonate and sorbitol reduced the area under the lithium serum concentration-time curve by 11.33%, reduced the mean observed peak serum lithium concentration 0.07 +/- 0.08 mmol/L, and delayed the time to the mean observed peak serum lithium concentration by 2.04 +/- 2.40 hours. CONCLUSION: Sodium polystyrene sulfonate and sorbitol may be used in patients immediately or shortly after ingestion of a significant acute overdose of lithium in situations in which hemodialysis cannot be instituted promptly.

Absorption↗