PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Radiotherapy Planning, Computer-Assisted”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Visualization of 3-D treatment plans with fast neutrons.

The treatment planning for radiotherapy with fast neutrons requires modifications of the planning systems used for photons. The neutron- and photon-component of the treatment fields must be determined and can then be used for separate calculations. The corrections for inhomogeneities are performed by use of attenuation coefficients and the corresponding corrections for changes in the kerma. The treatment planning system MEVAPLAN (Siemens) was modified to follow these requirements. Thus treatment planning for 14 MeV DT-neutrons could be performed. The multiplanar option is used to calculate 3D-dose distributions based on up to 40 serial CT slices. The generated three-dimensional dose matrix and the CT data are transferred via magnetic tape to the visualization system VOXEL-MAN developed at the University Hospital of Hamburg. This system uses a ray casting algorithm based on the generalized Voxel-model to display detailed 3D-images of human anatomy together with the calculated dose distribution. Different treatment plans for neutrons and photons are calculated and visualized. Various manipulations of the data-sets are displayed to improve the critical examination of the simulated dose distribution and to discern the quality of treatment techniques.

Fast Neutrons↗

ROENTGEN: case-based reasoning and radiation therapy planning.

ROENTGEN is a design assistant for radiation therapy planning which uses case-based reasoning, an artificial intelligence technique. It learns both from specific problem-solving experiences and from direct instruction from the user. The first sort of learning is the normal case-based method of storing problem solutions so that they can be reused. The second sort is necessary because ROENTGEN does not, initially, have an internal model of the physics of its problem domain. This dependence on explicit user instruction brings to the forefront representational questions regarding indexing, failure definition, failure explanation and repair. This paper presents the techniques used by ROENTGEN in its knowledge acquisition and design activities.

Artificial Intelligence↗

[Conformation radiotherapy of carcinoma of the prostate].

During the period from 1975 to 1989, 84 patients with carcinoma of the prostate were treated with conformation radiotherapy at Tokyo Metropolitan Komagome Hospital. The radiation field encompassed only the area of the prostate gland; it did not include the pelvic lymph nodes. The clinical stage of the 84 tumors was 22 in Stage A, 31 in Stage B, 15 in Stage C and 16 in Stage D. The average age of patients was 73.4 years, with range of 54 to 88 years. The average dose to the tumor was 65.7 Gy, with range of 60 Gy to 70 Gy. Hormone therapy was applied to 42 cases. The 5- and 10-year cumulative survival rates were 90.7% and 70.5% for Stage A, 41.7% and 26.7% for Stage B, 48.9% and 48.9% for Stage C, and 32.6% and 0% for Stage D, respectively. The 5-year cause-specific cumulative survival rates were 100% for Stage A, 92.3% for Stage B, 65.0% for Stage C and 40.3% for Stage D, respectively. Patients with poorly differentiated adenocarcinomas or undifferentiated carcinomas showed poorer survival than those with well-differentiated carcinoma. Only 7 cases suffered in-field recurrence, and 2 cases suffered recurrence at pelvic lymph nodes. Acute reactions were noted in 13 cases. Late complications following treatment were acceptable. Mild to moderate complications were recognized in 2 cases, but neither patient required surgery. In conclusion, our data suggest the advantage of the conformation technique applied to radiation therapy for carcinoma of the prostate.

Aged↗

High-performance computing in radiation cancer treatment.

In 1989 a consortium of the Radiation Oncology and Computer Science Departments at the University of North Carolina, BellSouth Corporation, GTE, and the MCNC was formed in response to the high-speed network initiative proposed by the National Science Foundation and the Defense Advanced Research Projects Agency. One of the purposes of this effort has been to demonstrate that applications exist that require gigabit per second networks. Our consortium, known as VISTAnet, proposed to use real-time radiation therapy treatment planning as the application that would require the use of a gigabit network. The plan was to develop a system that could rapidly calculate and display a three-dimensional radiation dose distribution for any configuration of radiation beams. The gigabit network would be used to tie the dose calculations done with the Cray Y-MP at the Research Triangle to the graphics engine at the Department of Computer Science (Pixel-Planes 5) and the medical workstation at Radiation Oncology. The system would then provide the radiation physician with the capability of considering hundreds of potential treatment plans, instead of the usual two or three, with the goal of arriving at a highly optimized plan within a few minutes.

Computer Communication Networks↗

Computer-aided medical decision making in radiotherapy.

Radiotherapy departments are becoming sophisticated in working with computers for isodose computations, treatment machine verifications and administrative and medical records. The next step lies in computer-assisted medical decision making. The logic for a patient's diagnostic work-up and treatment protocol can be stored in a computer. It can then be used as an aid in making the diagnosis, in prescribing the treatment and for quality control. For patients who fit established protocols the computer can select and list treatment using the logic of that protocol. Such a system has been implemented for the postoperative radiotherapy of breast cancer on a trial basis. Its potential usefulness is illustrated by results in 25 consecutive patients. Physician acceptance and costs of the program are under investigation.

Breast Neoplasms↗

Bayesian statistics: a guided tour.

An overview of Bayesian statistical decision theory is presented in the tutorial spirit. A section on fundamental principles is followed by selected applications of the Bayesian approach to parameter estimation, pattern recognition, image processing, computer-aided medical diagnosis, optimal diagnostic test selection, and radiotherapy treatment planning.

Decision Making↗

Investigating the potential of three-dimensional treatment planning.

3-D treatment planning has received a great deal of attention in the radiation therapy community over the last several years. This new technology makes use of the continuous improvements in computer hardware and graphics capabilities, along with major improvements in treatment planning software, to provide a fully three dimensional simulation of the patient, radiation beams, and dose distributions which are used for radiation therapy of various cancers. With these capabilities, the physician and treatment planner may now optimize the radiation beams used to treat the patient much more effectively than in the past, when only a limited description of the patient, beams, and doses was available. This paper describes several of the new capabilities of these 3-D planning systems, some research studies which are currently being performed to evaluate the usefulness of the new technology, and finally some of the costs associated with its implementation.

Computer Simulation↗

[Ultrasound in tumor diagnostics and treatment planning (author's transl)].

The fundamental requirements of irradiation planning are discussed delimitating the minimum and maximum demands of planning. Different possibilities to represent the topographic relations within the irradiation plane of the patient's cross-section are described. The computer-assisted system for irradiation planning, installed at our hospital by means of MAT construction, is discussed. A pathway is shown which leads to individual treatment planning and considers dosimetrically the actual conditions of the patient who will undergo radiation therapy. The possibilities and limits of ultrasonic cross-sectional imaging are demonstrated.

Diagnosis, Computer-Assisted↗

Computer-assisted 3D-reconstruction and statistics of the limbic system. 1. Computer-assisted 3D-reconstruction of the hippocampal formation, the fornix, and the mamillary bodies.

The hippocampal formation of eight perfusion-fixed human brains was examined using new methods according to stereotactic and morphometric principles (macrovibratome and computer-aided 3D reconstruction). The reconstructions form part of a neuroanatomical reference system (NeuRef). This reference system allows for 3D visualisation of the brain and its components on a computer graphic workstation, as well as for the presentation of the union set based on a neuroanatomical structure taken from this sample of brains. This retrievable knowledge of neurofunctional systems is important for the preoperative planning of neurosurgeons and the adjustment of radiotherapy.

Adult↗

New methods of imaging in diagnostic radiology Sylvanus Thompson Memorial Lecture.

A brief history of the recent developments in computer-assisted tomography (CAT) is presented. The development of whole-body scanners from the basic brain scanner, the trend towards higher-speed scanners using multiple detectors in a fan-type geometry, and some of the unsolved problems related to CAT scanners are discussed, as well as the potential use of whole-body scanning in radiotherapy treatment planning and in radiobiology. A review of recent developments in electrostatic imaging is presented and a new method of imaging called ionography is described in detail. It is shown how a single exposure can be used to produce a number of copies, each with a different amount of edge contrast, under the control of the radiologist. Further, it is shown how this can be done using a closed system so that the ionography chamber never needs to be opened. Some of the recent commercial developments in this field are described. It is suggested that in the future radiology departments may be replaced by departments of imaging, which will include all ways of obtaining diagnostic information and where such a department would be problem oriented rather than technique oriented. The need for basic scientific support by a medical physics and engineering group in such a department is emphasized.

Electrons↗

True three-dimensional dose computations for megavoltage x-ray therapy: a role for the superposition principle.

The objective of radiation therapy is to concentrate a prescribed radiation dose accurately within a target volume in the patient. Major advances in imaging technology have greatly improved our ability to plan radiation treatments in three dimensions (3D) and to verify the treatment geometrically, but there is a concomitant need to improve dosimetric accuracy. It has been recommended that radiation doses should be computed with an accuracy of 3% within the target volume and in radiosensitive normal tissues. We review the rationale behind this recommendation, and describe a new generation of 3D dose algorithms which are capable of achieving this goal. A true 3D dose calculation tracks primary and scattered radiations in 3D space while accounting for tissue inhomogeneities. In the past, dose distributions have been computed in a 2D transverse slice with the assumption that the anatomy of the patient dose not change abruptly in nearby slices. We demonstrate the importance of computing 3D scatter contributions to dose from photons and electrons correctly, and show the magnitude of dose errors caused by using traditional 2D methods. The Monte Carlo technique is the most general and rigorous approach since individual primary and secondary particle tracks are simulated. However, this approach is too time-consuming for clinical treatment planning. We review an approach that is based on the superposition principle and achieves a reasonable compromise between the speed of computation and accuracy in dose. In this approach, dose deposition is separated into two steps. Firstly, the attenuation of incident photons interacting in the absorber is computed to determine the total energy released in the material (TERMA). This quantity is treated as an impulse at each irradiated point. Secondly, the transport of energy by scattered photons and electrons is described by a point dose spread kernel. The dose distribution is the superposition of the kernels, weighted by the magnitude of the TERMA impulse for all interaction sites. In this review, we demonstrate the capabilities of the superposition method, particularly for situations of charged particle disequilibrium, and we report on the progress made by several research groups in adapting this method to clinical treatment planning. In the future, the superposition method will have a significant role in dose optimization for conformal irradiation techniques because of its close correspondence to image reconstruction by filtered back-projection.

Image Processing, Computer-Assisted↗

High dose rate treatment of a maxillary sarcomatoid carcinoma: a case report.

A 37-year old Native American woman presented with a rare sarcomatoid carcinoma of the left maxilla. She underwent extensive resection, but developed an orbital cavity recurrence. This was treated with external beam radiation therapy. The boost posed dosimetric difficulties due to the anatomic peculiarities of the treatment area. Extensive treatment planning for a high dose rate Iridium 192 source helped overcome these problems. Control of the tumor was achieved in the site of recurrence.

Adult↗

Various wedge isodose angles for treatment planning.

Various wedge isodose angles or simply wedge angles smaller than the nominal wedge angle were created by combining the isodose distributions generated from a single physical wedge with the isodose distributions of the open field for the 8-MV photon beam. The particular wedge angle generated depends on the weights imposed on these isodose distributions. The relationship between these weights and the wedge angle were examined and found to be nonlinear. The difference between the wedge angles defined at 10 cm depth and those defined using the 50% isodose curve is less 6 degrees. The present data was fitted using two proposed empirical equations.

Humans↗

A computer-assisted three-dimensional treatment planning system.

The three-dimensional treatment planning system developed at the Rhode Island Hospital visualizes the spatial interrelationships of the radiation beam, the tumor, and the adjacent organs within the patient. It is possible to rotate and vary the scale of the display to better comprehend the extent of these structures. By viewing the display as if from along the radiation beam, one can design shaped treatment fields which best suit the three-dimensional nature of the disease. With this system, it is possible to reduce the volume of normal tissue which would typically be irradiated if two-dimensional treatment planning techniques and assumptions were employed.

Computers↗

Backgrounds of computer-assisted treatment planning in radiation therapy.

Interaction of ionising radiation and living materials causes biological damage of tempory or permanent nature. In radiation therapy this phenomenon is used in a controlled fashion in order to stop the proliferation of malignant cells, while at the same time limiting the permanent damage to healthy tissues and organs to at least tolerable levels. Because of the often relatively small differences in response of malignant growths and normal tissues, the margins between tolerable and intolerable are so small that the greatest precision in treatment planning and execution is required. The nature of this treatment agent implies that the radiation therapist has to rely very much on instrumentally obtained and processed information, in all phases of this medical activities around the patient. In this paper a description is given of the backgrounds of computer-assisted methods which have enabled modern individualised and optimised planning for therapy with high enery X - and gamma beams.

Cobalt Radioisotopes↗

[Computerized planning of radiotherapy].

The hypophysis was studied by MR tomography in 148 patients with the most prevalent diseases of the hypothalamohypophyseal system and in 13 ones with primary hypothyrosis. The findings evidence a great variety of changes in the MRT picture in the examinees. The method permits a reliable diagnosis of hypophyseal macroadenoma and of an 'empty' sella turcica. Qualitative and quantitative criteria for MRT diagnosis of these conditions are suggested. The diagnostic value of MRT for the detection of macroadenomas is still to be researched. The method was effectively used for a dynamic follow-up of the hypophyseal status in the course of pathogenetic therapy; the formation of an 'empty' sella turcica is possible against the background of dopamine agonist therapy and substitution therapy of primary hypothyrosis.

Adolescent↗

[Optimization in planning and application of 60 Co gamma irradiations - analysis of the problem (author's transl)].

As an aspect of the complex problem of optimization in therapeutical transmission of radiation energy to Man, the dose distribution within a cross-sectional area of the body is considered. For the judgement on optimal dose distributions, involving judgement on irradiation technique, boundary conditions are needed which encompass important parameters of a dose distribution (= criterion for optima). For computer-assisted optimization the boundary conditions are to be scheduled by an appropriate algorithm. The parameters describing a dose distribution are indicated. Practical utilization of computer-assisted optimization of dose is represented by means of two optimization schedules.

Cobalt Radioisotopes↗