[New aspects of shock therapy with volume expanders (author's transl)].

For successful primary treatment of hemorrhagic shock the infusion of volume expanders is a ""conditio sine qua non''. Of the original possibilities for selection, Ringer's lactated injection can no longer be recommended for the compensation of intravascular loss in the light of more recent pathophysiological knowledge. Opposite to this, gelatin, dextran, hydroxyethyl starch, and albumin solutions are available as the mainstay of an adequate volume expansion. The danger of anaphylactoid side effects is to be estimated as about equal in all 4 groups of substances. Seen from the point of view of replacement function and of rheological and pharmacological properties, the higher molecular dextrans may still be considered the method of choice for shock therapy.

Dextrans↗

[Mediators and their antagonists in shock therapy].

The list of shock mediators currently comprises more than 150 candidates. A careful analysis using the criteria of Koch-Dale together with decision trees for exclusion of bias revealed that only histamine, C5a, beta-endorphin, tumor necrosis factor (TNF) thromboxane B2, platelet-activating factor (PAF), and oxygen free radicals are shown to be causally associated with shock symptoms. Although experimental studies with inhibitors of these mediators were convincing, there is still a lack of evidence under clinical conditions (exception histamine: anaphylactic shock). Combinations of antagonists against different causal mediators are the most promising future approaches.

Acute-Phase Proteins↗

Failure of third-generation implantable cardioverter defibrillators to abort shock therapy for nonsustained ventricular tachycardia due to shortcomings of the VF confirmation algorithm.

Unnecessary shocks by ICDs for rhythms other than sustained VT or VF have been described as the most frequent adverse event in ICD patients. To avoid unnecessary shocks for self-terminating arrhythmias, the third-generation Jewel PCD defibrillators 7202, 7219, and 7220 Plus use a specially designed VF confirmation algorithm after charge end. The purpose of this study was to determine the ability of this VF confirmation algorithm to recognize nonsustained VT, and to analyze the reasons for failure of the PCD device to abort shock therapy for nonsustained VT despite use of this VF confirmation algorithm. Analysis of stored electrograms of electrical events triggering high voltage capacitor charging in the programmed VF zone of the device showed 36 spontaneous episodes of nonsustained VT (227 +/- 21 beats/min) during 18 +/- 7 months follow-up in 15 patients who had a Jewel PCD implanted at our hospital. Intracardiac electrogram recordings and simultaneously retrieved marker channels demonstrated that the ICD shock was appropriately aborted according to the VF confirmation algorithm in 24 (67%) of 36 episodes of nonsustained VT. Twelve episodes (33%) of nonsustained VT, however, were followed by spontaneous ICD shock in 6 (40%) of the 15 study patients. The only reason for all 12 shocks for sustained VT was the inability of the device to recognize the absence of VT after charge end due to shortcomings of the VF confirmation algorithm: 11 of the 12 shocks for nonsustained VT were triggered by the occurrence of paced beats during the VF confirmation period and 1 shock for nonsustained VT was triggered by the occurrence of 2 premature beats after charge end. Thus, better VF confirmation algorithms need to be incorporated in future PCD devices to avoid unnecessary shocks for nonsustained VT.

Defibrillators, Implantable↗