Trace analysis of ethanol, MTBE, and related oxygenate compounds in water using solid-phase microextraction and gas chromatography/mass spectrometry.

Solid-phase microextraction (SPME) and gas chromatography/mass spectrometry have been combined for trace-level determination of very polar compounds in water, including the widely used gasoline oxygenates ethanol and methyl tert-butyl ether (MTBE). A relatively simple extraction method using a divinylbenzene/Carboxen/poly(dimethylsiloxane) SPME fiber was optimized for the routine analysis of ethanol and MTBE in groundwater and reagent water. A sodium chloride concentration of 25% (w/w) combined with an extraction time of 25 min provided the greatest sensitivity while maintaining analytical efficiency. Replicate analyses in fortified reagent and groundwater spiked with microgram per liter concentrations of ethanol and MTBE indicate quantitative and reproducible recovery of these and related oxygenate compounds. Method detection limits were 15 microg L(-1) for ethanol, 1.8 microg L(-1) for tert-butyl alcohol, 0.038 microg L(-1) for tert-amyl methyl ether, 0.025 microg L(-1) for ethyl-tert-butyl ether, and 0.008 microg L(-1) for MTBE.

Ethanol↗

Low part per trillion determination of reactive alkanethiols in wastewater by in situ derivatization-solid-phase microextraction followed by GC/MS.

A solid-phase microextraction (SPME) procedure for the simultaneous determination of volatile alkanethiols (i.e., methane-, ethane-, propanethiol) and dihydrogen sulfide in aqueous samples as stable thioethers followed by GC/MS determination was developed. Accordingly, N-ethylmaleimide as derivatization reagent in the aqueous phase was used for the first time, improving the analyte stability and method sensitivity in comparison to the determination of free forms. Thus, pH of the aqueous medium, reaction time, and derivatization reagent concentration have been evaluated, and the main parameters affecting the SPME process (i.e., coating selection, extraction mode and time profile, extraction and desorption temperatures) optimized. At the selected derivatization and extraction conditions, the proposed method provided no matrix effect either in the derivatization reaction or in the microextraction steps. RSD values were lower than 11% and LODs from 0.74 to 5.2 ng L(-1). The developed procedure was successfully applied to different water and wastewater samples, where dihydrogen sulfide and some of the target alkanethiols were identified at low-microgram per liter concentrations.

Journal Article↗

Identification of volatile compounds in cantaloupe at various developmental stages using solid phase microextraction.

Using an automated rapid headspace solid phase microextraction (SPME) method for volatile extraction in cantaloupes, 86 compounds already reported for muskmelons were recovered and an additional 53 compounds not previously reported were identified or tentatively identified. The SPME method extracted a copious number of volatiles that can be analyzed to clearly differentiate between variety, growth stage, and stage of harvest ripeness. Most of the newly reported compounds in cantaloupe were esters and aldehydes that have already been demonstrated as flavor-related compounds in other products. All esters believed to have flavor impact increased progressively after pollination, and this trend continued with increasing harvest maturity. However, compound recovery often decreased when fruits were harvested over-ripe. Most aldehydes increased during early growth stages and then tapered off with increasing harvest maturity. The SPME method suitably recovered most compounds reported to impart characteristic flavor/aroma in muskmelons. SPME offers experimental flexibility and the ability to discover more compounds and address flavor quality changes in fresh-cut cantaloupe.

Aldehydes↗

Detection of methyl ethyl ketone in urine using headspace solid phase microextraction and gas chromatography.

Headspace solid-phase microextraction coupled with gas chromatography/flame ionization detection was developed to measure urinary methyl ethyl ketone (MEK). A fused silica fiber coated with 75 microns carboxen/polydimethylsiloxane was used to extract urinary MEK. The optimal extraction conditions were obtained when temperature was 50 degrees C, extraction time was 15 minutes, and ammonium sulfate concentration was 0.5 g/mL. The optimal desorption temperature and time were 200 degrees C and 5 minutes, respectively. The concentration range of calibration curves was 27 to 8000 ng/mL of MEK. The within-day and between-day pooled coefficients of variation (9 concentrations, triplicate samples) were 5.4% and 8.8%, respectively. The limit of detection and limit of quantitation were 4.2 ng/mL and 21.6 ng/mL, respectively. The recovery (+/- standard deviation) of MEK was 100.2% +/- 8.6% (n = 3). MEK in urine was stable for at least 1 month when stored at -20 degrees C. This method proved to be applicable for the analysis of urinary MEK of exposed workers in a plastic material printing plant. We concluded that this new method is sensitive, inexpensive, simple, and reliable for measuring the occupational exposure of MEK.

Adult↗

[Estimation of the octanol-water partition coefficients of PAHs by solid-phase microextraction].

Eleven PAHs were analyzed by solid-phase microextraction-gas chromatography/ion trap detector and their partition coefficients were obtained at equilibrium. When the polymer coating of the fiber may be viewed as one kind of organic solvent, the linear free energy relationship between the polydimethylsiloxane-water partition coefficient (Ksw) and octanol-water partition coefficient (Kow) was established by solid-phase microextraction, which was log Ksw = 0.9318 log Kow-0.2056 with good correlation coefficient 0.9504. The linear equation may be used to estimate the octanol-water partition coefficient of other PAHs and similar H acceptors compounds. Being compared with Leo's method which was based on the additive-constitutive nature of the partition coefficient, the solid-phase microextraction method may distinguish efficiently Kow of the isomer.

Chromatography, Gas↗

Determination of chlorophenols by solid-phase microextraction and liquid chromatography with electrochemical detection.

A solid-phase microextraction method has been developed for the determination of 19 chlorophenols (CPs) in environmental samples. The analytical procedure involves direct sampling of CPs from water using solid-phase microextraction (SPME) and determination by liquid chromatography with electrochemical detection (LC-ED). Three kinds of fibre [50 microm carbowax-templated resin (CW-TPR), 60 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) and 85 microm polyacrylate (PA)] were evaluated for the analysis of CPs. Of these fibres, CW-TPR is the most suitable for the determination of CPs in water. Optimal conditions for both desorption and absorption SPME processes, such as composition of the desorption solvent (water-acetonitrile-methanol, 20:30:50) and desorption time (5 min), extraction time (50 min) and temperature (40 degrees C) as well as pH (3.5) and ionic strength (6 g NaCl) were established. The precision of the SPME-LC-ED method gave relative standard deviations (RSDs) of between 4 and 11%. The method was linear over three to four orders of magnitude and the detection limits, from 3 to 8 ng l(-1), were lower than the European Community legislation limits for drinking water. The method was applied to the analysis of CPs in drinking water and wood samples.

Chlorophenols↗

Determination of amphetamine, methamphetamine and dimethamphetamine in human urine by solid-phase microextraction (SPME)-gas chromatography/mass spectrometry.

A simple and rapid assay method for three stimulant drugs (amphetamine, methamphetamine, and dimethamphetamine) in human urine using solid-phase microextraction was developed. In solid-phase microextraction, the drugs were equilibrated between the adsorbent coated-fiber and aqueous sample matrix. After adsorption of the analytes, the fiber was directly transferred to the injector of a gas chromatograph, where the analytes were thermally desorbed and subsequently separated by the gas chromatograph and detected by mass spectrometer. The solid-phase microextraction method, which did not require solvents, was found to be a fast and simple analytical method. We optimized the solid-phase microextraction technique, for factors such as the NaCl salt effect (30%), pH effect (pH=12.4), equilibration time (30 min), desorption time (1 min) and coated-fiber type (100 microm poly(dimethylsiloxane)) and detected the stimulants in human urine, obtained from human subjects. The detection limits of each drug were below 1-10 ng/ml. The developed method can be applied to the abused drug test.

Amphetamine↗

Coupling solid-phase microextraction to liquid chromatography. A review.

Solid-phase microextraction (SPME) is a technique for extraction of organic compounds from gaseous, aqueous, and solid matrices. SPME is rapid and simple, ideal for automation and for in situ measurements, and no harmful solvents are needed. The principle of SPME involves equilibration of the analytes between the sample matrix and an organic polymeric phase coated on a fused-silica fiber. SPME is traditionally combined with analysis by gas chromatography (GC) and this combination has proved sensitive, accurate, and precise for quantitative analysis of different classes of volatile compound. More recently SPME has been coupled with liquid chromatography to widen its range of application to non-volatile and thermally unstable compounds also. This article reviews the status of SPME coupled with liquid chromatography. It focuses on different applications of the technique, e.g. environmental samples, biological fluids, and food samples, to show that SPME-HPLC has great potential in the analysis of a wide range of compounds in different matrices.

Journal Article↗

Sampling and Raman confocal microspectroscopic analysis of airborne particulate matter using poly(dimethylsiloxane) solid-phase microextraction fibers.

Commercial poly(dimethylsiloxane) (PDMS) 7-microm solid-phase microextraction (SPME) fibers were used for sampling and Raman spectroscopic analysis of a tailpipe diesel exhaust, candle smoke, cigarette smoke, and asbestos dust. Samples were collected via direct exposure of the SPME fiber to contaminated air. The mass loading for SPME fibers was varied by changing the sampling time. Results indicate that PDMS-coated fibers provide a simple, fast, reusable, and cost-effective air sampling tool for airborne particulates. The PDMS coating was stable; Raman bands of the PDMS coating were observed exactly at the same wavenumber positions before and after air sampling. Raman spectroscopic analysis resulted in identification of several characteristic bands allowing chemical speciation of particulates. The advantage of the SPME fiber is the open bed geometry allowing for application of various spectroscopic methods of particulate analysis. This paper describes the first-ever combined application of SPME technology with Raman confocal microspectroscopy for sampling and analysis of airborne particulates. Advantages of the combination of solid-phase microextraction and Raman microspectroscopy for airborne particulate analysis are discussed. Challenges associated with combined SPME sampling and Raman analysis of single particles are also described.

Journal Article↗

Time-weighted average water sampling with a diffusion-based solid-phase microextraction device.

A new diffusion-based solid-phase microextraction (SPME) time-weighted average (TWA) field water sampling device was developed and investigated by field trial. The sampler is constructed with copper tube and caps and a commercial SPME fiber assembly. The device possesses all advantages of SPME; it is solvent-free, reusable, combines sampling, isolation and enrichment into one step, and the fiber can be directly injected into a gas chromatograph for analysis with a commercial SPME fiber holder, without further treatment. Field trials in Laurel Creek (Waterloo, Ont., Canada) and Hamilton Harbour (Hamilton, Ont., Canada) illustrated that the device is durable, easy to deploy, and the mass uptake of the device is independent of the face velocity. The device provides good precision [relative standard deviations (RSDs) are less than 20%] and the data obtained with this device are quite comparable to those obtained with the spot sampling method, which demonstrates that the newly developed SPME water sampling device is suitable for long-term monitoring of organic pollutants in water.

Diffusion↗

Diffusive sampling of methylene chloride with solid phase microextraction.

This study examined the characteristics of a solid phase microextraction (SPME) assembly as a passive sampler to determine the short-term exposure level (STEL) of methylene chloride. Two types of SPME fibers and six sampling-related factors were chosen and nested in an L(18) Taguchi's orthogonal array. Samples were thermally desorpted and analyzed by gas chromatograph equipped with an electron capture detector (GC/ECD). The use of 85-mum Carboxen/polydimethylsiloxane (Car/PDMS) fibers resulted in greater adsorbed mass, which was highly correlated with the product of concentration and sampling time (r>0.99, p<0.0001), than 85-microm polyacrylate fibers. The sampling rate (SR) of the 85-microm Carboxen/polydimethylsiloxane fibers was not significantly affected by variations in relative humidity (0-80%) and coexistent toluene (none to 100 ppm). Variance of sampling rate was predominantly attributed to the diffusive path length (86.4%) and sampling time (5.7%). With diffusive paths of 3, 10 and 15 mm, the sampling rates of 85-microm Carboxen/polydimethylsiloxane fibers for methylene chloride were 1.4 x 10(-2), 7.7 x 10(-3) and 5.1 x1 0(-3)mL min(-1), respectively. The measured sampling rates were greater than the theoretical values, and decreased with increment of sampling time until they came to constant.

Chromatography, Gas↗

Analysis of chloro- and nitrobenzenes in water by a simple polyaniline-based solid-phase microextraction coupled with gas chromatography.

A simple solid-phase microextraction (SPME) device, coupled with gas chromatography-electron capture detection (GC-ECD) was developed to detect trace levels of chloro- and nitrobenzene compounds in environmental water samples. Polyaniline (PANI) was chosen as the extraction material for the SPME device, and was electrochemically deposited on a stainless steel wire to achieve high mechanical stability. Due to the peculiar pi-pi conjugated structure, PANI coating shows a stable performance in high temperature (to 350 degrees C) and solvents (organic and inorganic). The porous structure of PANI film characterized by scanning electron microscopy (SEM) revealed high extraction efficiency. The possible extraction mechanism was explained by the study carried out using electrochemical impedance spectroscopy (EIS). Eight chloro- and nitrobenzene compounds were selected to evaluate the SPME-GC procedures. The key parameters such as extraction and desorption temperature and time, and the ionic strength were investigated and optimized. The method was applied to the detection of environmental water samples collected from Taihu Lake, representing nowadays contamination level under industrial impact. The whole PANI-SPME-GC method offers high accuracy and precision, high sensitivity and low detection limits. Thus, the method developed could be used as a new way to monitor the trace levels of chloro- and nitrobenzene compounds in real water bodies.

Aniline Compounds↗

Comparison of different fibers for the solid-phase microextraction of phthalate esters from water.

Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) has been applied to determine six phthalate esters and one adipate ester in water. The SPME parameters were optimized for several commercially available fibers. A 65-microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) was the fiber selected and was applied to analysis of water from the Ebro river and the industrial port of Tarragona. The studied compounds were found at concentrations ranging from 0.4 microg l(-1) for di-n-butyl phthalate ester (DnBP) to 3.2 microg l(-1) for bis(2-ethylhexyl) phthalate ester (DEHP). The linear range for real samples was from 0.1 to 10 microg l(-1) for most phthalates, and the limits of detection of the method were between 3 and 30 ng l(-1). Repeatability and reproducibility between days (n = 5) for 1 microg l(-1) samples were below 13 and 18%, respectively.

Dibutyl Phthalate↗

Optimization of headspace sampling using solid-phase microextraction for volatile components in tobacco.

Solid-phase microextraction (SPME) was evaluated as a tool for headspace sampling of tobacco samples. Several experimental parameters (e.g. sampling temperature, pH, moisture, and the type of SPME fibers) were optimized to improve sampling efficiency in two aspects; maximum adsorption and selective adsorption of volatile components onto SPME fibers. The effect of these parameters was often dominated by the physical and chemical nature (e.g. volatility, polarity) of target compounds, thus, SPME sampling conditions can be adjusted to favor a selected group of compounds, such as organic acids in tobacco.

Gas Chromatography-Mass Spectrometry↗

Determination of carbonyl compounds in water by derivatization-solid-phase microextraction and gas chromatographic analysis.

The solid-phase microextraction (SPME) technique was evaluated for the determination of 23 carbonyl compounds in water. The carbonyl compounds in water were derivatized with omicron-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine hydrochloride (PFBHA), extracted with SPME from liquid or headspace and analyzed by GC with electron capture detection (GC-ECD). The effects of agitation techniques and the addition of salt (NaCl) on extraction, the absorption-time and absorption-concentration profiles were examined. The precision of the SPME technique for the determination of carbonyl compounds was evaluated with spiked bidistilled water, ozonated drinking water, and rain water. The relative standard deviations obtained from different spiked water matrix were similar, and in the range of 5.7-21.1%. The precision can be further improved by using an internal standard. With 4 ml of water sample, the limits of detection for most of the tested carbonyl compounds using liquid or headspace SPME-GC-ECD were similar and in the range of 0.006-0.2 micrograms/l, except for glyoxal and methylglyoxal, which showed low sensitivity when using headspace SPME. In the analysis of an ozonated drinking water sample, the SPME techniques gave comparable results to those of the conventional liquid-liquid extraction method.

Absorption↗

Fibers coated with molecularly imprinted polymers for solid-phase microextraction.

The simplicity and flexibility of solid-phase microextraction have been combined with the selectivity of molecularly imprinted polymers (MIPs). Silica fibers were coated reproducible with a 75-microm layer of methacrylate polymer either nonimprinted or imprinted with clenbuterol to compare their extraction characteristics under various conditions. Although the template molecule could be removed effectively from the imprinted polymer, structural analogues of clenbuterol were used for evaluation. The influence of pH on the extractability of brombuterol was investigated. Extraction yields up to approximately 80% were obtained when both types of fibers were used to extract brombuterol from phosphate buffer (pH 7.0). In contrast, yields of about 75 and <5% were obtained when extraction was performed from acetonitrile with imprinted and nonimprinted polymers, respectively, which demonstrates the selectivity of the MIP-coated fiber. Time sorption profiles were measured for the extraction of brombuterol from buffer and acetonitrile at the 10 and 100 ng/mL level with both types of fibers in order to compare extraction characteristics. Equilibrium times of about 30 and 90 min were found for the extraction of brombuterol from acetonitrile and buffer, respectively. The MIP-coated fibers were capable of extracting five structural analogues of clenbuterol from both buffer and acetonitrile, which suggests that the amine alcohol part of these molecules is responsible for interaction with the imprinted polymer. To achieve selective extraction of brombuterol from human urine, MIP-coated fibers were washed with acetonitrile after the extraction. Clean extracts and yields of approximately 45% were obtained, demonstrating the suitability of MIP-coated fibers for the analysis of biological samples.

Journal Article↗

Electrochemically controlled solid-phase microextraction based on conductive polypyrrole films.

Solid-phase microextraction (SPME) fiber coatings based on conductive polypyrrole films were prepared for the electrochemical extraction and desorption of ionic analytes. Simple preparation of each of the PPY extraction coatings on a platinum wire was possible with a constant potential method, but more importantly, cycling of the film between oxidation and reduction potentials facilitated the extraction and desorption of ionic analytes. The analytes were desorbed into a sample aliquot of water and were determined by flow injection analysis using a mass spectrometer. The fiber coatings and the developed electrochemical SPME method were found to be stable and reproducible (RSD < 5%; N = 5) and could be extended to several cations and anions, confirming the versatility of the approach. Preconcentration of the analyte on the fiber was also possible by repeating the processes to increase the amount of analyte extracted.

Letter↗

Determination of 3-chloropropane-1,2-diol in liquid hydrolyzed vegetable proteins and soy sauce by solid-phase microextraction and gas chromatography/mass spectrometry.

Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) method was developed to determine 3-chloropropane-1,2-diol (3-MCPD) in hydrolyzed vegetable protein and Chinese soy sauce. The 3-MCPD was firstly derivativized with phenylboronic acid in aqueous solution at 90 degrees C for 10 min, then extracted by HS-SPME and finally detected with GC/MS, parameters related to both the derivative reaction and the HS-SPME process were optimized. The proposed method has a linear range of 0.0194-394 microg g(-1), a detection limit of 3.87 ng g(-1) (S/N = 3), and a precision of RSD = 7.5% (n = 5). Seventeen real samples, including four HVPs and thirteen soy sauce samples, were analyzed to examine the feasibility of the proposed procedure; with a concentration of 3-MCPD and acceptable recoveries at 0.71 microg g(-1) spiked levels were obtained. Being simpler, faster and more environmentally benign than the existing methods, this method is accurate and suitable for routine analysis.