PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Ultrasonography, Doppler, Color”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Evaluation of hemodynamic changes in the ophthalmic artery with color Doppler ultrasonography after strabismus surgery.

PURPOSE: To investigate the blood flow changes in ophthalmic artery with color Doppler ultrasonography after strabismus surgery. METHODS: Twenty eyes of 19 patients who underwent recession or resection surgery on two horizontal rectus muscles in 1 eye were examined using color Doppler ultrasonography preoperatively and 1 week and 1 month postoperatively. Measurements from both eyes of 16 age- and sex-matched normal subjects served as control data. The systolic maximum velocity, mean velocity, end-diastolic velocity, pulsatility index, and resistance index of the ophthalmic artery were determined. The Mann-Whitney U test was performed for comparison of the control and study group preoperatively for any hemodynamic parameter. Statistical comparison of the preoperative and postoperative measures in the study group was performed with Friedman's two-way analysis of variance. RESULTS: No difference (P>.05) was observed preoperatively between the study and control groups for any hemodynamic parameter in the ophthalmic artery. Although the ophthalmic artery showed a slight increase in systolic maximum velocity 1 month postoperatively, there were no statistically significant differences (P>.05) in velocities or resistance in the ophthalmic artery at any interval. CONCLUSION: Two horizontal rectus muscle operations in a previously unoperated eye do not cause significant hemodynamic changes in the ophthalmic artery. However, further studies are needed to obtain more information about the effect of multiple vertical rectus muscle operations on the blood flow parameters of the ophthalmic artery.

Adolescent↗

[Clinical studies for venogenic impotence with color Doppler ultrasonography--evaluation of resistance index of the cavernous artery].

BACKGROUND: Pharmaco-dynamic infusion cavernosometry and cavernosography (pharmaco-DICC) is essential for diagnosis of venogenic impotence, however it is so invasive. On the other hand, color Doppler ultrasonography is non-invasive and has become one of the useful diagnostic methods for arteriogenic impotence. And there are some reports evaluating whether venogenic impotence can be diagnosed using color Doppler ultrasonography. In this study, we investigated whether the resistance index (RI) could be useful for screening for venogenic impotence. METHODS: We performed color Doppler ultrasonography in 49 patients who had shown negative responses to an intracavernous injection of 20 mcg of prostaglandin E1 (PGE1). They previously underwent pharmaco-DICC and were diagnosed venogenic impotent when the maintenance flow rate was equal to or more than 20 ml/min. In 49 patients, 17 patients had DICC normality, while 32 patients had corporal leakages. After an intracavernous injection of 20 mcg of PGE1, we performed color Doppler ultrasonography, and measured peak systolic velocity (PSV) and end diastolic velocity (EDV) in the cavernous artery. RI was calculated as follows. RI = (PSV-EDV)/PSV We adopted the RI value near to 1 as the case's RI from two RI values of bilateral cavernous arteries, and compared RI values with the results of pharmaco-DICC. RESULTS: RI range in patients with normal DICC results was 0.895 +/- 0.092 (0.70-1.00), while RI range in patients with corporal leakages was 0.742 +/- 0.095 (0.55-0.97). RI values in patients with corporal leakages were significantly lower than those in patients with normal DICC results although there was some overlap in each group. From receiver-operating-characteristic curve (ROC curve) of the correlation between sensitivity and specificity at various RI values compared with DICC results, the RI cut off values were set up at 0.75 and 0.90, and classified the patients into 3 group according to their RI cut off values. In 10 patients with 0.9 < RI, 9 patients (90%) had DICC normality. In 17 patients with 0.75 < RI < or = 0.9, 7 patients had DICC normality while 10 patients had corporal leakages. In 22 patients with RI < or = 0.75, 21 patients (95.5%) had corporal leakages. CONCLUSION: We consider without carrying out pharmaco-DICC that patients with 0.9 < RI were not venogenic impotent, while patients with RI < or = 0.75 had corporal leakages. Pharmaco-DICC will remain essential only in patients with 0.75 < RI < or = 0.9.

Adult↗

Color Doppler ultrasonography and serum CA 125 in the differentiation of benign and malignant ovarian tumors.

Color Doppler ultrasonography and serum CA 125 were used to evaluate 114 adnexal tumors prior to surgery. Six patients were excluded from this study because of ovarian cancer, borderline ovarian malignancy, and tubal gestation. A total of 108 patients were eligible: 83 patients with benign and 25 patients with malignant ovarian tumors. Resistance index (RI) was used to determine the peripheral resistance of intratumoral vessels. The cutoff point for the RI was defined as 0.5. The blood flow was considered to be normal when the RI was greater than 0.5 and abnormal when it was less than 0.5. The blood flow was detected in 100% of malignant tumors and 59% of benign tumors. The initial cutoff value for CA 125 was 35 U/mL. Sensitivity, specificity, positive predictive value, and negative predictive value were compared in terms of RI, serum CA 125, and a combination of the two. Our conclusion is that the combination of RI and CA 125 gives a sensitivity of 100% and negative predictive value of 100%. If the cutoff point of CA 125 was raised from 35 to 65 U/mL, then a specificity of 100% and positive predictive value of 100% were also attained with the use of RI and CA 125 without changes in sensitivity or negative predictive value. We conclude that the combination of color Doppler ultrasonography and serum CA 125 is an effective method to differentiate benign from malignant ovarian tumors.

Adolescent↗

Color Doppler ultrasonography in the diagnosis of vascular abnormalities associated with ureteropelvic junction obstruction.

PURPOSE: To determine if color Doppler ultrasonography is able to identify vascular abnormalities linked to ureteropelvic junction (UPJ) obstruction. PATIENTS AND METHODS: We used color Doppler scanning in 21 patients to determine whether there were aberrant vessels. RESULTS: The study detected 11 aberrant vessels, resulting in 10 true positives and 9 true negatives. Thus, the overall diagnostic accuracy was 90.4%. CONCLUSION: Color Doppler ultrasonography is reliable in the preoperative diagnosis of aberrant vessels associated with UPJ obstruction.

Adolescent↗

Adjunctive color Doppler ultrasonography in second-trimester transabdominal amnioinfusion.

Transabdominal amnioinfusion improves the diagnostic accuracy of ultrasonography in pregnancies complicated by second-trimester oligohydramnios. Needle localization may be difficult because of patient obesity or the absence of an acoustic window. The two cases presented demonstrate that color Doppler imaging facilitates amnioinfusion by visualizing the injection jet of free-flowing infusate, confirming intraamniotic needle placement.

Adult↗

Ovarian torsion: diagnosis by color Doppler ultrasonography.

BACKGROUND: Ovarian torsion, although a rare gynecologic emergency, is a threat to women of all ages. Traditionally, ultrasonography and laparoscopy facilitated early diagnosis and treatment of this condition. This case report highlights the usefulness of color Doppler ultrasonography in the diagnosis of ovarian torsion. CASE: A 25-year-old patient who conceived after ovulation induction was treated conservatively for mild ovarian hyperstimulation and threatened abortion. She subsequently underwent selective first-trimester multifetal reduction and was admitted and treated for suspected pelvic infection. On the 17th post-procedure morning, ovarian torsion was diagnosed using color Doppler ultrasonography. CONCLUSION: Because gynecologists face serious management dilemmas when confronted with ovarian torsion, this technique of using color Doppler ultrasonography should provide a highly specific finding in complete ovarian torsion, aiding the clinician in prompt diagnosis and treatment.

Adult↗

Intervillous and spiral artery flows in normal pregnancies between 5 and 10 weeks of amenorrhea using color Doppler ultrasonography.

OBJECTIVE: The aim of our study was to investigate early placental circulation development and spiral and uterine artery flows in normal 1st-trimester pregnancies. METHODS: A prospective study of intervillous and spiral artery flows in 49 normal pregnancies (5-10 weeks of amenorrhea) was performed. Transvaginal color and pulsed-wave Doppler techniques (6-MHz probe) were used as routine ultrasound scanning modalities before pregnancy termination for psychosocial reasons. RESULTS: In all pregnancies, between 5 and 10 weeks, continuous nonpulsatile intervillous flow (mean V(max) 3.55 cm/s) and spiral artery flow (mean peak systolic velocity 16.2 cm/s, mean diastolic index D/S 0.49 +/- 0.089) were detected. In the 47 women in whom the uterine artery flow was measured, the mean peak systolic velocity was 67.5 cm/s, the mean diastolic index was 0.12, and bilateral notching was observed. CONCLUSIONS: In all cases, between 5 and 10 weeks, slow and continuous nonpulsatile intrachorionic flow could be detected, whereas pulsatile flow was detected in spiral arteries. The true nature of this early intervillous circulation remains to be determined.

Adolescent↗

Preoperative assessment of vascularity by color Doppler ultrasonography in human rectal carcinoma.

PURPOSE: Although angiogenesis assessed by immunostaining endothelial cells (microvessel density) is a well-known prognostic factor in a wide variety of human solid tumors, preoperative determination of microvessel density seems to be difficult in rectal carcinoma. Thus, we performed transanal color Doppler ultrasonography in 46 patients with rectal carcinoma to assess preoperative angiogenic status and compare it with microvessel density in surgical specimens. METHODS: Time-averaged maximal velocity, peak systolic velocity, number of vascular points, and vascular point index were conducted by color Doppler ultrasonography in 46 patients with rectal carcinoma. Number of vascular points was defined as the number of vessels with pulsation in the section of tumor. Vascular point index was defined as the average number of vascular points divided by the area assessed by color Doppler ultrasonography in the section of tumor. The profiles of number of vascular points were similar to those assessed by microangiography in five rectal carcinomas. RESULTS: Vascular point index significantly correlated with microvessel density (P < 0.0001). No significant correlation was found between microvessel density and time-averaged maximal velocity or peak systolic velocity. Vascular point index was also a better indicator of lymph node metastasis and venous invasion than microvessel density. In addition, 11 of 46 cases with postoperative hematogenous metastasis (23.9 percent) were observed prospectively. Vascular point index may be a best predictor for hematogenous metastasis from rectal carcinoma compared with peak systolic velocity, time-averaged maximal velocity, and microvessel density by receiver operating characteristic analysis. CONCLUSION: These results suggest that preoperative quantification of angiogenesis using color Doppler ultrasonography will provide quick and useful information in the management of rectal carcinoma.

Blood Flow Velocity↗

Color Doppler ultrasonography in the earlier differentiation of benign molehydatidiforms from malignant gestational trophoblastic disease.

BACKGROUND: To find out the effectiveness of color Doppler ultrasonography of the uterine arteries in the differentiation of benign molehydatidiforms from malignant gestational trophoblastic disease. METHODS: Prospective study was performed in 32 women who were referred to the Oncology Department with the diagnosis of gestational trophoblastic disease. Uterine artery Doppler studies were made and resistance index for both uterine arteries were calculated. In the follow-up, twelve of these patients required chemotherapy (first group) and 20 of them were treated with only suction curettage (second group). Non parametric Mann Whitney U test was used for the statistical analysis. RESULTS: Median of the lowest uterine artery resistance index were 0.29 for the first group and 0.46 for the second group. Resistance index were significantly lower in the first group (alpha<0.001). Color Doppler study of the uterine arteries is helpful in the differentiation of benign molehydatiforms from malignant gestational trophoblastic disease.

Adult↗

Post-traumatic arterial priapism evaluation with color Doppler ultrasonography: a case report.

The patient was a 19-year-old man who was examined due to persistent penile erection, which appeared following a blow to the perineal region during work. Color Doppler ultrasonography of the corpora cavernosa revealed a cavity in one part of the cavernous artery that suggested a blood leak, and a diagnosis of high flow type priapism due to trauma was made. Bilateral internal pudendal arteriography demonstrated dilation and extravasation in one part of the right cavernous artery, then transarterial embolization was performed superselectively in the right cavernous artery using an autologous clot. However, 2 weeks after treatment, slight penile erection reoccurred. Color Doppler ultrasonography revealed reformation of the cavity at the treated lesion, and embolization was again performed using a gelatin sponge. Following embolization, the course proceeded satisfactorily without any relapse. Color Doppler ultrasonography, which is non-invasive and can be easily performed, is considered to be an effective means for diagnosis and follow up of arterial high flow priapism.

Adult↗

[Comparison of color Doppler ultrasonography and endoscopic ultrasonography for preoperative evaluation of the mesenteric-portal axis in pancreatic lesions].

AIM OF THE STUDY: This prospective study was undertaken to evaluate the accuracy of ultrasonography combined with colour Doppler and endoscopic ultrasonography for predicting superior mesenteric and portal vein involvement in pancreatic diseases. MATERIAL AND METHODS: The study was prospective. Forty-four patients were included. Ultrasonography with colour Doppler was performed in 30 patients, endoscopic ultrasonography in 43. Prediction of superior mesenteric vein or portal vein involvement was blindly assessed by physicians without knowledge of results of other imaging methods. Resectability or potential resectability (n = 34) and irresectability (n = 10) were assessed in all patients by surgery. Thirty patients underwent a pancreaticoduodenectomy. RESULTS: For endoscopic ultrasonography the sensitivity (0.90), the specificity (0.88), the positive predictive value (0.69) and the negative predictive value (0.97) were better than those observed with ultrasonography and Doppler (050, 0.88, 0.69, 0.97, respectively). The specificity of computed tomography (0.96) was better than that of endoscopic ultrasonography but predictive negative values were similar. CONCLUSIONS: Imaging methods to predict superior mesenteric or portal vein involvement in pancreatic diseases are becoming increasingly numerous, complex, and expensive. Endoscopic ultrasonography has a better diagnostic value for correctly predicting resectability than ultrasonography with Doppler. However, for decision making, usefulness of these methods seems to be limited.

Adenocarcinoma↗

Compression repair of ruptured pseudoaneurysms guided by color Doppler ultrasonography: report of two cases.

Noninvasive treatment of ruptured postcatheterization pseudoaneurysms is rare. We report the use of ultrasonographically guided compression repair for the treatment of ruptured pseudoaneurysms in 2 cases. To ensure the immediate stop of bleeding, more compression was applied than for nonruptured pseudoaneurysms, regardless of flow in the femoral artery or vein, thus maximizing the effectiveness of this therapy. With this method, complete thrombosis of the pseudoaneurysm could be achieved in less than 30 minutes. In both cases, ultrasonographically guided compression repair was faster than the time needed to prepare an operating room for surgical treatment. In follow-up examinations, no recurrences or further complications were detected. Ultrasonographically guided compression repair can be used for noninvasive treatment of ruptured pseudoaneurysms in some cases, provided that more compression than indicated for nonruptured pseudoaneurysms is applied. Further clinical experience with more patients will be necessary to determine the exact benefits and possible limitations.

Aged↗

Color Doppler ultrasonography of the superior mesenteric artery for prenatal ultrasonographic diagnosis of a left-sided congenital diaphragmatic hernia.

The incidence of congenital diaphragmatic hernia (CDH) has been estimated as 1 per 2000 to 1 per 4000 births. The etiology of the malformation is unknown, but it has been reported in association with maternal administration of medications such as thalidomide or antiepileptics before closure of the pleuroperitoneal canal at 9 to 10 weeks' gestation as well as having a familial inheritance pattern. Congenital diaphragmatic hernia is associated with other congenital anomalies in 25% to 57% of cases and with chromosomal abnormalities in 10% to 20% of cases. Posterolateral, anterolateral, and pars sternalis defects of closure of the pleuroperitoneal canal encompass the 3 types of CDH. The most frequent type is the left-sided posterolateral defect or Bochdalek's hernia, which accounts for 81% of cases.

Adult↗