PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Volatile Organic Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Empirical relations predicting human and rat tissue:air partition coefficients of volatile organic compounds.

Based on the hypothesis that tissue partitioning of volatile organic compounds (VOCs) is due to lipophilic and hydrophilic interactions with tissue components, empirical relations are established between olive oil (P(oil:air)), saline (P(saline:air)), and tissue partition coefficients (P(tissue:air)) for human and rat tissues. Reported values of partition coefficients of a wide range of VOCs with distinct chemical structures (n = 137) have been compiled from the literature. Bilinear regression analysis shows that partition coefficients of VOCs in human blood, brain, fat, liver, kidney, and muscle tissues are well described by a linear combination of P(oil:air) and P(saline:air) with tissue-specific regression coefficients. The regression coefficient associated with the hydrophilic component of VOC partitioning in rat tissues is systematically higher than that of human tissues. For the human model, tissue concentrations calculated from predicted partition coefficients are generally within a factor 4 of tissue concentrations calculated from experimentally observed partition coefficients. These results demonstrate that, without prior knowledge of tissue composition, it is possible to obtain estimates of human tissue partition coefficients of VOCs with an accuracy that is in the same range as that commonly used in risk assessment.

Air↗

How to estimate moments and quantiles of environmental data sets with non-detected observations? A case study on volatile organic compounds in marine water samples.

Concentrations of 27 priority volatile organic compounds were measured in water samples of the North Sea and Scheldt estuary during a 3-year monitoring study. Despite the use of a sensitive analytical method, a number of data were censored. That is, some concentrations were below the decision limit or critical level defined by IUPAC. To characterize the observed measurement results, an attempt was made to identify an appropriate procedure to compute summary statistics for the censored data sets. Several parametric and robust parametric approaches based on the maximum likelihood principle and probability-plot regression method were evaluated for the estimation of the mean, standard deviation, median and interquartile range using three uncensored analytes (1,1,2-trichloroethane, tetrachloroethene and o-xylene) from the monitoring survey. Performance was assessed by artificially censoring the observed concentrations and estimating moments and quantiles at each censoring level. Results showed that methods with the least distributional assumptions, such as the robust bias-corrected restricted maximum likelihood method, perform best for estimating the mean and standard deviation, while both parametric and robust parametric techniques can be used for quantiles. Hence, summary statistics could be estimated with little bias (5-10%) up to 80% of censoring for the data sets employed in this study.

Likelihood Functions↗

Photocatalytic oxidation of volatile organic compounds using fluorescent visible light.

Photocatalytic oxidation (PCO) of volatile organic compounds (VOCs) is a highly attractive alternative technology for purification and deodorization of indoor air. The main objectives of this study were to demonstrate that a common fluorescent visible light (FVL) lamp can be used to effectively remove by PCO low concentrations of VOCs from slightly contaminated air and to provide some fundamental and technical details on the process. The target VOC was n-butanol, which is a standard reference odorant. Its PCO was studied under a long residence time in a 3.7-L cylindrical reactor with commercial titanium dioxide (TiO2) as the reference photocatalyst and using mostly FVL for illumination. For comparison only, a UV (black) light lamp was used. The gas-phase products were detected and quantified online by gas chromatography (GC). The effects of reactor residence time, of inlet concentration, and of the relative light intensity on the efficiency of the process were also evaluated. At a high n-butanol concentration (0.1 vol %), butanal and propanal were identified as the intermediate products of the process; ethanal appeared when the initial concentration was < or = 850 ppm(v). This indicates that PCO leading to CO2 and H2O is relatively slow and proceeds in a stepwise manner. Although the efficiency of the process with an FVL lamp was significantly lower than when using a UV black light, complete PCO of low concentrations was achieved for 100 ppm(v). In a search for a material with photoactivation extended to higher wavelengths or increased photoactivity, several samples of transition metal- or silver ion-doped (2 atomic %) TiO2 as well as SrTi(1-x-)Fe(x)O3 (x = 0.1 and 0.15) perovskites were included in the study. None of these materials was more active than pure TiO2. The results of this study open new horizons in the area of in door air quality (IAQ) control.

Air Pollutants↗

Evaluation of a hypercrosslinked polystyrene, MN-200, as a sorbent for the preconcentration of volatile organic compounds in air.

Breakthrough volumes, average percentage recoveries, and storage stabilities were obtained for vapors of 8 volatile organic compounds (pentane, octane, undecane, isooctane, cyclohexane, toluene, methanol, and dichloromethane) on a new adsorbent material, Hypersol-Macronet, MN-200. Breakthrough volumes were estimated as half of the gas chromatographic specific retention volumes at 20 degrees C for the compounds. Recoveries of the adsorbates were determined by both solvent extraction and thermal desorption methods. The results obtained compare favorably with those for Tenax GR (values reported in the published literature and others obtained in our laboratory). Results of storage stability studies on MN-200 meet the criterion for acceptability (<10% loss). High adsorption capacity for very volatile and polar compounds, combined with ease of desorption of less volatile compounds, render MN-200 a highly promising adsorbent for sampling volatile organic compounds in indoor and outdoor air.

Adsorption↗

[Assessment of the emission of volatile organic compounds from polyurethane foams].

The emission of 2,4- and 2,6-diaminotoluene, triethylenediamine, diethanolamine and other volatile organic compounds from polyurethane foams was examined in environmental chamber. Tested materials did not release of amines. The emission of total volatile organic compounds showed differences for polyurethane samples but did not exceed ecological standards.

Air Pollutants↗

Multiple types of sensory neurons respond to irritating volatile organic compounds (VOCs): calcium fluorimetry of trigeminal ganglion neurons.

Many volatile organic compounds (VOCs) are significant environmental irritants that stimulate somatosensory nerve endings to produce pain and irritation. We measured intracellular calcium in cultured trigeminal ganglion neurons to characterize the cellular mechanisms and chemical structural determinants underlying sensitivity to VOCs. Trigeminal neurons responded to homologous series of alcohols (C4-C7) as well as saturated and unsaturated aldehydes in a concentration dependent manner. Ranked in terms of threshold to recruit neurons by compounds of the same carbon chain length, enaldehyde<aldehyde<alcohol. Unlike aldehydes and alcohols that displayed ascending concentration curves, recruitment of neurons by enaldehydes (C4-C7) appeared to saturate, consistent with a mechanism that is restricted in its neural distribution. Using pentanol, pentanal and pentenal as model compounds, we found that many but not all cool/cold-sensitive and capsaicin-sensitive neurons responded with increases in intracellular calcium. These VOCs also stimulated other neurons that were insensitive to cooling and capsaicin. Because not all cooling- and all capsaicin-sensitive neurons responded to the model VOCs, it is highly unlikely that known nociceptive ion channels such as TRPV1 or TRPA1 mediate sensitivity to these compounds. For pentanol, pentanal and pentenal, induced calcium influx was dependent on the presence of extracellular calcium. Responses of all neurons to pentanal and pentenal were also dependent upon extracellular sodium. Responses to pentanol were variably dependent on sodium. The distribution of sensitivity suggests that VOC irritation may be mediated by an as yet unidentified mechanism(s) that is/are distributed across different modalities of neurons.

Aldehydes↗

[Determination of volatile organic compounds in atmospheric environment].

It is well known that volatile organic compounds (VOCs) are the main photochemical pollutants and ozone precursors of the photochemical smog. Investigation of photochemical pollution in the ambient air must focus on VOCs, but the concentration of VOCs in ambient air is in a very low level (10(-9)-10(-12), volume fraction), so there are difficulties in the determination of VOCs. In this work, based on the TO14A and TO15 methods recommended by the Environmental Protection Agency of United States, an improved method for the determination of fifty-six VOCs, mainly O3 precursors, in atmospheric environment was developed. Operating conditions of VOCs preconcentrator, gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) were optimized. Air sample was first frozen by liquid nitrogen, and then H2O and CO2 were eliminated in the VOCs preconcentrator. The preconcentrated VOCs sample was injected to GC and detected by MS or hydrogen flame ionization detector (FID). The C2-C10 hydrocarbons were separated effectively in capillary columns under the high concentration of CO2. The detection limits were 0.1 microgram.m-3 and the relative standard deviations were in the range from 2.57% to 9.82%. This method has been used for the determination of VOCs in real samples. The results were satisfactory.

Air Pollutants↗

Design and laboratory testing of a chamber device to measure total flux of volatile organic compounds from the unsaturated zone under natural conditions.

To determine if an aquifer contaminated with volatile organic compounds (VOCs) has potential for natural remediation, all natural processes affecting the fate and transport of VOCs in the subsurface must be identified and quantified. This research addresses the quantification of air-phase volatile organic compounds (VOCs) leaving the unsaturated zone soil gas and entering the atmosphere-including the additional flux provided by advective soil-gas movement induced by barometric pumping. A simple and easy-to-use device for measuring VOC flux under natural conditions is presented. The vertical flux chamber (VFC) was designed using numerical simulations and evaluated in the laboratory. Mass-balance numerical simulations based on continuously stirred tank reactor equations (CSTR) provided information on flux measurement performance of several sampling configurations with the final chamber configuration measuring greater than 96% of model-simulated fluxes. A laboratory device was constructed to evaluate the flux chamber under both diffusion-only and advection-plus-diffusion transport conditions. The flux chamber measured an average of 82% of 15 diffusion-only fluxes and an average of 95% of 15 additional advection-plus-diffusion flux experiments. The vertical flux chamber has the capability of providing reliable measurement of VOC flux from the unsaturated zone under both diffusion and advection transport conditions.

Air Movements↗

Gas chromatographic method for trapping and detection of volatile organic compounds from human mouth air.

The present investigation describes a convenient method for collection and analysis of volatile organic compounds from 25 ml mouth air samples. Tenax-GC trapping devices coated with Teflon are used to adsorb and concentrate volatile organic compounds in mouth air at -20 degrees C, which are then thermally desorbed at 140 degrees C. Gas chromatography (GC) analyses are performed using an aluminum column coated with Teflon and packed with 2% poly-MPE on 80/100 mesh Tenax-GC, and employing a flame ionization detector. This procedure allows for amplification of peak heights and detection of compounds that may otherwise escape direct analysis. Of the six prominent peaks detected, identification based on retention times indicates the presence of methanol, acetaldehyde, ethanol and acetone. Volatiles collected using this procedure can be maintained at -20 degrees C for up to 48 hours before analysis. The compact sample tubes allow the system to be easily portable, particularly suitable for sampling breath of persons with localized oral or systemic diseases at locations away from the laboratory. The superiority of this method is that relatively small samples are required for analysis, unlike previously published methods which are based on collection of large volumes of expired air in plastic bags.

Air Pollutants↗

Characterization of volatile organic compounds in smoke at municipal structural fires.

The objective of this study was to characterize volatile organic compounds (VOCs) found at municipal structural fires in order to identify sources of long-term health risks to firefighters, which may be contributing factors in heart disease and cancer. Firefighters collected air into evacuated Summa canisters inside burning buildings at nine municipal structural fires under conditions where they judged that at least some firefighters might remove their self-contained breathing apparatus masks. Volatile organic compounds were identified and quantified for 144 target compounds using cryogenic preconcentration and gas chromatography/mass spectral detection (GC/MSD) methodology operating in selected ion monitoring mode. Samples were also analyzed in SCAN mode and examined for the appearance of substances that were not present in the instrument standard calibration mixture. The spectra of municipal structural fires were surprisingly similar and remarkable for their simplicity, which was largely due to the dominating presence of benzene along with toluene and naphthalene. Propene and 1,3-butadiene were found in all of the fires, and styrene and other alkyl-substituted benzene compounds were frequently identified. Similar "fingerprints" of the same 14 substances (propene, benzene, xylenes, 1-butene/2-methylpropene, toluene, propane, 1,2-butadiene, 2-methylbutane, ethylbenzene, naphthalene, styrene, cyclopentene, 1-methylcyclopentene, isopropylbenzene) previously identified at experimental fires burning various solid combustible materials were also found at municipal structural fires, accounting for 76.8% of the total VOCs measured. Statistically significant positive correlations were found between increasing levels of benzene and levels of propene, the xylenes, toluene, 1-butene/2-methylpropene, 1,3-butadiene, and naphthalene. Given the toxicity/carcinogenicity of those VOCs that were found in the highest concentrations, particularly benzene, 1,3-butadiene, and styrene, further investigation of VOC exposures of firefighters is warranted. Benzene, or its metabolic product s-phenylmercapturic acid in urine, was identified as a suitable chemical marker for firefighter exposure to combustion products.

Alkenes↗

Evaluation of the separation characteristics of application-specific (volatile organic compounds) open-tubular columns for gas chromatography.

The solvation parameter model is used to characterize the separation characteristics of two application-specific open-tubular columns (Rtx-Volatiles and Rtx-VGC) and a general purpose column for the separation of volatile organic compounds (DB-WAXetr) at five equally spaced temperatures over the range 60-140 degrees C. System constant differences and retention factor correlation plots are then used to determine selectivity differences between the above columns and their closest neighbors in a large database of system constants and retention factors for forty-four open-tubular columns. The Rtx-Volatiles column is shown to have separation characteristics predicted for a poly(dimethyldiphenylsiloxane) stationary phase containing about 16% diphenylsiloxane monomer. The Rtx-VGC column has separation properties similar to the poly(cyanopropylphenyldimethylsiloxane) stationary phase containing 14% cyanopropylphenylsiloxane monomer DB-1701 for non-polar and dipolar/polarizable compounds but significantly different characteristics for the separation of hydrogen-bond acids. For all practical purposes the DB-WAXetr column is shown to be selectivity equivalent to poly(ethylene glycol) columns prepared using different chemistries for bonding and immobilizing the stationary phase. Principal component analysis and cluster analysis are then used to classify the system constants for the above columns and a sub-database of eleven open-tubular columns (DB-1, HP-5, DB-VRX, Rtx-20, DB-35, Rtx-50, Rtx-65, DB-1301, DB-1701, DB-200, and DB-624) commonly used for the separation of volatile organic compounds. A rationale basis for column selection based on differences in intermolecular interactions is presented as an aid to method development for the separation of volatile organic compounds.

Chromatography, Gas↗

Volatile organic compounds associated with microbial growth in automobile air conditioning systems.

Volatile organic compounds from Penicillium viridicatum and Methylobacterium mesophilicum growing on laboratory media and on component materials of automobile air conditioners were analyzed with gas chromatography and mass spectrometry. P. viridicatum produced compounds such as 4-methyl thiazole, terpenes and alcohols, whereas M. mesophilicum produced dimethyl disulfide, dimethyl trisulfide, and chlorophenol with growth on laboratory media. In comparison with laboratory media, fewer volatiles were detected from colonized foam insulation materials. Biofilms of M. mesophilicum on aluminum evaporator components produced mainly dimethyl disulfide. These biofilms, after inoculation with P. viridicatum, produced offensive smelling alcohols and esters such as 2-methyl propanol, 3-penten-2-ol, and the ethyl ester of butanoic acid. The moisture and substrates innate to the automobile air conditioning systems provided an environment suitable for microbial biofilm development and odor production. Reduction of retained moisture in the air conditioning system coupled with use of less susceptible or antimicrobial substrates are advised for remediation of the noxious odors.

Air Conditioning↗

Measuring concentrations of volatile organic compounds in vinyl flooring.

The initial solid-phase concentration of volatile organic compounds (VOCs) is a key parameter influencing the emission characteristics of many indoor materials. Solid-phase measurements are typically made using solvent extraction or thermal headspace analysis. The high temperatures and chemical solvents associated with these methods can modify the physical structure of polymeric materials and, consequently, affect mass transfer characteristics. To measure solid-phase concentrations under conditions resembling those in which the material would be installed in an indoor environment, a new technique was developed for measuring VOC concentrations in vinyl flooring (VF) and similar materials. A 0.09-m2 section of new VF was punched randomly to produce -200 0.78-cm2 disks. The disks were milled to a powder at -140 degrees C to simultaneously homogenize the material and reduce the diffusion path length without loss of VOCs. VOCs were extracted from the VF particles at room temperature by fluidized-bed desorption (FBD) and by direct thermal desorption (DTD) at elevated temperatures. The VOCs in the extraction gas from FBD and DTD were collected on sorbent tubes and analyzed by gas chromatography/mass spectrometry (GC/MS). Seven VOCs emitted by VF were quantified. Concentration measurements by FBD ranged from 5.1 microg/g VF for n-hexadecane to 130 microg/g VF for phenol. Concentrations measured by DTD were higher than concentrations measured by FBD. Differences between FBD and DTD results may be explained using free-volume and dual-mobility sorption theory, but further research is necessary to more completely characterize the complex nature of a diffusant in a polymer matrix.

Air Pollution, Indoor↗

Receptor model comparisons and wind direction analyses of volatile organic compounds and submicrometer particles in an arid, binational, urban air shed.

The relationship between continuous measurements of volatile organic compounds sources and particle number was evaluated at a Photochemical Assessment Monitoring Station Network (PAMS) site located near the U.S.-Mexico Border in central El Paso, TX. Sources of volatile organic compounds (VOCs) were investigated using the multivariate receptor model UNMIX and the effective variance least squares receptor model known as Chemical Mass Balance (CMB, Version 8.0). As expected from PAMS measurements, overall findings from data screening as well as both receptor models confirmed that mobile sources were the major source of VOCs. Comparison of hourly source contribution estimates (SCEs) from the two receptor models revealed significant differences in motor vehicle exhaust and evaporative gasoline contributions. However, the motor vehicle exhaust contributions were highly correlated with each other. Motor vehicle exhaust was also correlated with the ultrafine and accumulation mode particle count, which suggests that motor vehicle exhaust is a source of these particles at the measurement site. Wind sector analyses were performed using the SCE and pollutant data to assess source location of VOCs, particle count, and criteria pollutants. Results from this study have application to source apportionment studies and mobile source emission control strategies that are ongoing in this air shed.

Air Pollutants↗

Identification limits for volatile organic compounds in the blood by purge-and-trap GC-FTIR.

An analysis method for volatile organic compounds in blood based on purge-and-trap extraction coupled with gas chromatography-Fourier transform infrared spectroscopy (GC-FTIR) was developed. The sample volume was 5 mL, and the internal standard was diethyl ketone. The chromatographic separation was carried out on a PoraPLOT Q capillary column, and the effluent was first directed to the FTIR and then to a flame ionization detector (FID). FTIR identification limits were measured for 27 volatile organic compounds; the criteria for the limit were that the first hit-list position should be obtained against the Sadtler library, which contains 3240 spectra, and that the correlation value should exceed 0.5. It was required that the peak be seen by FID but not necessarily by a Gram-Schmidt chromatogram. The FTIR identification limits, ranging from 0.01 mg/L for ethyl acetate, methylethyl ketone, and sevoflurane to 24 mg/L for methanol, generally allowed the detection of volatile-substance exposure at a lower level than is acutely toxic. Quantitative calibration data were presented for selected substances, based on the FID response, which shows that the method is also amenable to quantitative analysis. The throughput of the method without additional automation is five samples per day, the purge-and-trap stage being the limiting factor.

Flame Ionization↗

[Indoor pollution and biological monitoring of volatile organic compounds (VOC)].

Indoor air is a complex mixture of chemicals and airborne particles. Volatile Organic Compounds (VOC), a broad class of chemicals including diverse compounds such as Aldehydes, Terpenes, Aromatic and Aliphatic Hydrocarbons and Halogenated Volatile Organics, are an important category of indoor air pollutants. The evaluation of exposure to low doses of Chloroform and Benzene through the measurement of Chloroform and Benzene in urine was performed. Results show that biological monitoring may be helpful in indoor environmental studies in non occupational situations.

Air Pollution, Indoor↗

Screening toxic effects of volatile organic compounds using Drosophila melanogaster.

The suitability of Drosophila melanogaster for biological screening of the toxic effects of volatile organic compounds was investigated. Adult flies were exposed to vapours of some organic solvents and gasoline under saturating conditions in the sublethal range. In some cases the dose-response relationship was studied. As a measure of the overall metabolism, CO2 production was recorded before and after exposure, including the recovery period, and the body activity was scored and classified as "normal behaviour", hyperactivity or excitement or narcosis. Significant differences were observed for the different solvents and volatile mixtures (vapours of acetone, benzene, methanol, toluene, xylene, diethylether, leaded and unleaded gasoline and diesel fuel). The length of the narcosis induced by the volatile organic compounds correlated well with their octanol-water coefficients. After exposure to benzene, toluene and gasoline a marked increase in the CO2 production during narcosis was observed. Methanol exposure led to a long-lasting increase in CO2 production, but did not cause narcosis. There were also differences in the behaviour (body activities) in the recovery phase between the solvents tested. Thus, the results from these experiments suggest that the measurement of CO2 production combined with the scoring of body activities in Drosophila can be used as a sensitive screening procedure in inhalation toxicology, revealing different types of toxic reactions for different types of volatile compounds.

Animals↗

Measurement of volatile organic compounds in the urban atmosphere of Harris County, Texas, USA.

Volatile organic compounds (VOCs) are a major component of urban air pollution. It is well documented that exposure to certain types of VOCs can cause adverse health effects such as cancer, immune and neurological damage, and reproductive and endocrine disorders. Urban air samples were collected at five locations in Harris County, Texas to determine the measurement of VOCs in the ambient air of residential areas in close proximity to industrial facilities that emit toxic air pollutants into the air. Three locations used in this study were located along the Houston Ship Channel (HSC), in the heart of one of the largest petrochemical complexes in the nation. Two other sampling locations were located many miles away from the ship channel and any industrial facilities that are required to report toxic air emissions. Air samples were collected daily over an 8-h period from December 2002 to March 2003. The samples were collected in 6-L stainless steel Silonite-coated canisters and analyzed using a modified version of EPA Method TO-15. A total of 53 compounds was quantitated using a gas chromatograph mass spectrometer system coupled to a cryogenic preconcentrator. Eighteen alkanes and oxygenated compounds were identified, along with 7 alkenes and 5 aromatic compounds. Several alkanes such as butane, isobutane, 2-methyl butane, and pentane were detected at all five sites. The total VOC concentrations determined were highest at two of the industrial sites and lowest at the site farthest away from the ship channel and any industrial facilities. This study concluded that the atmosphere near Harris County's industrial complex had higher concentrations of VOCs than the atmosphere in areas farther away from the HSC. The atmosphere of areas downwind from emission sources were found to be directly affected by toxic air emissions from industrial process but not at the levels seen in areas closer to the HSC.

Air↗