PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “phase space reconstruction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5Linked to original sources

Partial Fourier imaging in multi-dimensions: a means to save a full factor of two in time.

We present an improvement to the traditional one-dimensional partial Fourier method by extending the method to multi-dimensions. The modified method allowed a full factor of two savings in time with much better coverage of the central k-space information and, because of this, smaller reconstruction artifacts. The residual magnitude error was found to correlate strongly with the residual phase error. Numerical simulation also indicated that with a priori perfect phase information, the original magnitude image could be perfectly reconstructed with half of the k-space data points in the multi-dimensional case. Simulated, phantom, and human data sets were tested with edge differences ranging from 10% (consistent with variable Gibbs ringing) to 25% (consistent with a blurred version of the object). The method was found to be a valuable adjunct to human imaging for short TR, T1-weighted three-dimensional gradient-echo imaging and magnetic resonance (MR) angiographic methods, especially when short echo times were used.

Algorithms↗

On the fitting of model electron densities into EM reconstructions: a reciprocal-space formulation.

A fast method for fitting model electron densities into EM reconstructions is presented. The methodology was inspired by the molecular-replacement technique, adapted to take into account phase information and the symmetry imposed during the EM reconstruction. Calculations are performed in reciprocal space, which enables the selection of large volumes of the EM maps, thus avoiding the bias introduced when defining the boundaries of the target density.

Image Processing, Computer-Assisted↗

Using prior knowledge of human anatomy to constrain MR image acquisition and reconstruction: half k-space and full k-space techniques.

In this note, we demonstrate how to utilize prior knowledge of human cranial anatomy to constrain full k-space and half k-space acquisition and reconstruction of 128 times 128 images. We used a database of magnetic resonance head images to derive new basis functions which represent the most important features of the head. the "training" images were also used to derive formulas for reconstructing head images from a subset of the usual 128 phase-encoded signals and to determine the optimal k-space locations of those signal measurements. We used this algorithm, called Feature-Recognizing MRI, to reconstruct 128 times 128 head images from 50-60% of the signals filling the full k-space. Furthermore, we combined the algorithm with a conventional half k-space technique to create 128 times 128 images from only 60% of the 80 signals required by the usual unconstrained half k-space imaging. Thus, the prior knowledge represented by the image database, together with a half k-space technique, made it possible to construct accurate magnetic resonance images from only 30-40% of the complete set of 128 signals. In other words, a database of head images was used to devise a 1/3 k-space method for imaging the head.

Adult↗

A virtual source model for Monte Carlo modeling of arbitrary intensity distributions.

A photon virtual source model was developed for simulating arbitrary, external beam, intensity distributions using the Monte Carlo method. The source model consists of a photon fluence grid composed of a matrix of square elements, located 25-cm downstream from the linear accelerator target. Each particle originating from the fluence map is characterized by the seven phase space parameters, position (x, y, z), direction (u, v, w), and energy. The map was reconstructed from fluence and energy spectra acquired by modeling components of the linear accelerator treatment head using the Monte Carlo code MCNP4B. The effect of contaminant electrons is accounted for by the use of a sub-source derived from a phase-space simulation of a 25-MV linac treatment head using the code BEAM. The BEAM sub-source was incorporated into the MCNP4B phase-space model and is sampled using a field-size dependent sampling ratio. A Gaussian blurring kernel is convolved with the photon fluence map to account for the finite focal spot size and scattering effects from structures such as the flattening filter and MLC leaves. Depth dose and profile source calculations for 6-MV and 25-MV photon beams, for 5 x 5 cm2, 10 x 10 cm2, and 15 x 15 cm2 field sizes, are in good agreement with measurement and are well within acceptability criteria suggested by the AAPM Task Group Report No. 53. Irregular field calculations compared with film measurement and with a 3-D pencil beam algorithm show that the source model is capable of accurately simulating arbitrary MLC fields.

Biophysical Phenomena↗

Feature-recognizing MRI.

We describe a new theory of MR imaging that utilizes prior information in the form of a set of "training" images thought to be similar to the "unknown" objects to be scanned. First, the training images are processed to find an orthonormal series representation of these images that is more convergent than the usual Fourier series. The coefficients in this new series can be calculated from a subset of the phase-encoded signals needed to construct the Fourier image representation. The characteristics of the training images also determine exactly which phase-encoded signals should be measured in order to minimize error in the image reconstruction. The optimal phase-encodings are usually scattered nonuniformly in kappa-space. Good results were obtained when this theory was applied to imaging data from simulated objects and to experimental data from phantom scans. This theory provides the basis for developing efficient scanning and image reconstruction techniques that are "tailored" to each body part or to particular disease states.

Algorithms↗

Reconstruction of electron spectra from depth doses with adaptive regularization.

Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned and this may lead to nonphysical oscillations in the reconstructed spectra. Use of a variational method of solution with a regularization technique removes the oscillations but tends to smooth the sharp (deltalike) energy peak that is a common feature in electron spectra generated by medical accelerators. Because the sharp peak contains a large percentage of the electrons in the spectrum, an accurate estimate of the peak width, height and position is critical to the success of the technique for spectrum reconstruction with regularization. We propose use of an adaptive regularization term as a special form of the general Tichonov regularization function. The variational method with the adaptive regularization term is applied to reconstruct electron spectra for the 6, 9, and 18 MeV electron beams of a Varian Clinac 2100C accelerator and proves to be a very simple, effective and accurate approach. Results using this variational method with adaptive regularization almost perfectly reconstruct electron spectra from depth dose distributions.

Electrons↗

PC-based system for retrospective cardiac and respiratory gating of NMR data.

A method and a means for retrospectively clustering NMR k-space measurement profiles with respect to both cardiac and respiratory phases were developed to explore strategies for (1) reducing cardiovascular and respiratory flow/motion image artifacts and (2) improving T1 and T2 characterization of the heart. The image data are collected at a uniform rate so that echo (TE) and repetition (TR) times are independent of the varying cardiac cycle R-R interval and/or respiratory motions. Cardiac (C) time, respiratory (R) time or diaphragm position, and NMR data acquisition (A) cycle time are collected by microcomputer in parallel with free running (untriggered) image collection on a standard magnetic resonance imager. After the raw data equivalent of multiple images are collected, the C-A-R phase timing data are uploaded from the microcomputer to the scanner's minicomputer for use in a normalized C-R phase plane clustering of the image raw data. Each profile's position in the C-R phase plane is determined and then clustered into a new set of data, one image being equivalent for each desired C-R phase combination. These raw data are then zero-filled and (optionally) filtered to compensate for the nonuniform k-space sampling and, finally, reconstructed. Cardiac "cines" made from these retrospectively gated images are comparable to similarly phased triggered images. When high time resolution is required, retrospective gating can be expected to show improvements over triggering, especially toward the critical latter part of the cardiac cycle, where coronary artery filling occurs. The system described can readily be assembled from generally available components.

Electrocardiography↗

Diffusion tensor imaging using partial Fourier STEAM MRI with projection onto convex subsets reconstruction.

Diffusion-weighted single-shot STEAM MRI allows for diffusion mapping of the human brain without sensitivity to resonance offset effects. In order to compensate for its inherently lower SNR and speed than echo-planar imaging, this work describes the use of partial Fourier encoding in combination with image reconstruction by the projection onto convex subsets algorithm. The method overcomes phase distortions in diffusion-weighted partial Fourier acquisitions that disturb the conjugate complex symmetry of k-space and preclude the use of respective reconstruction techniques. In comparison with full Fourier encoding and a static flip angle for the STEAM readout pulses, experimental results at 2.9 T demonstrate a gain in relative SNR per unit time by 20% for 5/8 phase encoding with optimized variable flip angles. Simultaneously, the imaging time is reduced from about 670 ms (80 echoes) to 440 ms (50 echoes). Current implementations at 2 x 2 mm2 in-plane resolution comprise a protocol for clinical anisotropy studies (12 diffusion-encoding gradient directions at 1000 s mm(-2)) covering 18 sections of 4-mm thickness within a measurement time of 8.5 min (5 averages) and a version optimized for fiber tracking using 24 gradient directions and 38 sections of 2-mm thickness yielding a measurement time of 29.5 min (4 averages).

Anisotropy↗

A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series.

A 3D sequence for dynamic susceptibility imaging is proposed which combines echo-shifting principles (such as PRESTO), sensitivity encoding (SENSE), and partial-Fourier acquisition. The method uses a moderate SENSE factor of 2 and takes advantage of an alternating partial k-space acquisition in the "slow" phase encode direction allowing an iterative reconstruction using high-resolution phase estimates. Offering an isotropic spatial resolution of 4 x 4 x 4 mm(3), the novel sequence covers the whole brain including parts of the cerebellum in 0.5 sec. Its temporal signal stability is comparable to that of a full-Fourier, full-FOV EPI sequence having the same dynamic scan time but much less brain coverage. Initial functional MRI experiments showed consistent activation in the motor cortex with an average signal change slightly less than that of EPI.

Algorithms↗

Chaotic responses of the hippocampal CA3 region to a mossy fiber stimulation in vitro.

Undoubted evidence of chaotic activity of a biological neural network are given. Spontaneous epileptiform bursts of a neuron population in the CA3 region of rat hippocampal slices were caused in a perfusing medium with 2 mM penicillin and 8 mM K+ ions, and responses of field potential in the CA3 region to a periodic mossy fiber stimulation were investigated. Phase-locked and chaotic responses occur depending on stimulus parameters; for example, when the frequency of the stimulation increases, 1:1 phase-locking bifurcates to chaos through 1:2 phase-locking. The chaotic responses show a broad-band spectrum, and their trajectories in the three-dimensional phase space (V(t), V(t + tau), V(t + 2 tau)) reconstruct a strange attractor. Lyapunov exponents of the strange attractors estimated by the Wolf's algorithm are positive. Moreover, one-dimensional strobomaps obtained from the chaotic responses show a non-invertible function. Since the slope of each strobomap at their fixed point is more negative than -1, the fixed points are unstable. These are undoubted evidences for chaotic responses of the CA3 region in hippocampal slices maintained in vitro. Cross-correlation functions between field potential responses which were simultaneously observed at different sites show that the responses are spatially coherent throughout the CA3 region even when the responses are chaotic.

Action Potentials↗

Epileptic seizures can be anticipated by non-linear analysis.

Epileptic seizures are a principal brain dysfunction with important public health implications, as they affect 0.8% of humans. Many of these patients (20%) are resistant to treatment with drugs. The ability to anticipate the onset of seizures in such cases would permit clinical interventions. The view of chronic focal epilepsy now is that abnormally discharging neurons act as pacemakers to recruit and entrain other normal neurons by loss of inhibition and synchronization into a critical mass. Thus, preictal changes should be detectable during the stages of recruitment. Traditional signal analyses, such as the count of focal spike density, the frequency coherence or spectral analyses are not reliable predictors. Non-linear indicators may undergo consistent changes around seizure onset. Our objective was to follow the transition into seizure by reconstructing intracranial recordings in implanted patients as trajectories in a phase space and then introduce non-linear indicators to characterize them. These indicators take into account the extended spatio-temporal nature of the epileptic recruitment processes and the corresponding physiological events governed by short-term causalities in the time series. We demonstrate that in most cases (17 of 19), seizure onset could be anticipated well in advance (between 2-6 minutes beforehand), and that all subjects seemed to share a similar 'route' towards seizure.

Electrophysiology↗

The penalty throw in water polo: a cinematographic analysis.

Three-dimensional (3-D) high-speed cinematography was used to record the penalty throw in water polo by six elite male (M) and six elite female (F) players. The direct linear transformation technique (DLT) was used in the 3-D space reconstruction from 2-D images recorded via laterally placed phase-locked cameras operating at 200 Hz. Five of the twelve subjects lifted the ball from underneath at the start of the throw whilst the remaining subjects opted for a rotation lift. As the ball was brought behind the head the females used very little hip and shoulder rotation compared to the male players so that four of the six female subjects were square on to the target at the rear point. At the completion of the backswing the wrist was flexed to a similar angle (M-162 degrees; F-158 degrees); the elbow angle showed significantly greater flexion for females (85 degrees) than males (107 degrees). During the forward swing, from rear point to release, the wrist joint of the female players flexed from a rear point angle of 158 degrees to 148 degrees at release. The wrist movement for male subjects was different from the females in that it flexed from 162 degrees to 147 degrees, 0.10 s prior to release and then extended to 159 degrees at palmar release before again flexing to 156 degrees at release. The amount of elbow extension during the forward swing was 48 degrees for both groups; however, the females actually released the ball with the forearm vertical (89 degrees) compared to the male forearm angle of 78 degrees. Maximum angular velocity of the wrist and elbow occurred at release for 9 of the 12 subjects. Both the wrist and elbow joints (F-148 degrees; M-156 degrees at wrist and F-126 degrees; M-148 degrees at elbow) demonstrated greater flexion at release in female subjects, compared with males. Maximum linear endpoint velocities for the forearm and hand segments occurred at ball release resulting in mean ball velocities of 19.1 m s-1 and 14.7 m s-1 for male and female subjects respectively.

Adult↗

A biomechanical comparison of the topspin and backspin forehand approach shots in tennis.

Three-dimensional (3-D) high-speed cinematographic techniques were used to record topspin and backspin forehand approach shots hit down-the-line by high-performance players. The direct linear transformation (DLT) technique was used in the 3-D space reconstruction from 2-D images recorded via laterally placed phase-locked cameras operating at 200 Hz. A Mann-Whitney U-test was calculated for the different aspects of the topspin and backspin shots to test for significance (P less than 0.05). A significant difference was recorded between topspin and backspin shots in the angle of the racket at the completion of the backswing. The racket was taken 0.48 rad past a line drawn perpendicular to the back fence for topspin trials, but only rotated 0.86 rad from a line parallel to the net in the backspin shot. Maximum racket velocities occurred prior to impact and were significantly higher in topspin (26.5 m s-1) compared to backspin (16.6 m s-1) trials. This resulted in the topspin trials recording a significantly higher ball velocity compared to backspin trials (27.6 m s-1 vs 21.7 m s-1). Pre-impact racket trajectories revealed that in topspin shots the racket moved on an upward path of 0.48 rad while in backspin shots it moved down at an angle of 0.34 rad. In the topspin trials impact occurred significantly further forward of the front foot than in backspin shots (0.26 m vs 0.05 m) while the angle of the racket was the same for both strokes (0.14 rad behind a line parallel to the net). The mean angle of the racket-face at impact was inclined backwards by 0.11 rad for backspin strokes and rotated forward by 0.13 rad for topspin strokes. Angles of incidence and reflection of the impact between the ball and the court showed that backspin trials had larger angles of incidence and reflection than topspin strokes.

Adult↗

Linear motion correction in three dimensions applied to dynamic gadolinium enhanced breast imaging.

Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accurately track contrast enhancement and washout in lesions over the course of multiple volume acquisitions. Patient motion during the dynamic acquisitions is a limiting factor that degrades the image quality, particularly of subsequent subtraction images used to identify and quantitatively evaluate regions suggestive of malignancy. Keyhole imaging is particularly sensitive to motion since datasets acquired over an extended period are combined in k-space. In this study, motion is modeled as set of translations in each of the three orthogonal dimensions. The specific objective of the study is to develop and implement an algorithm to correct the consequent phase shifts in k-space data prior to offline keyhole reconstruction three-dimensional (3D) volume breast MR acquisitions.

Algorithms↗

Ghost artifact reduction for echo planar imaging using image phase correction.

An algorithm is described for reducing ghost artifacts in echo planar imaging (EPI) using phase corrections derived from images reconstructed using only even or odd k-space lines. The N/2 ghost, that arises principally from time-reversal of alternate k-space lines, was significantly reduced by this algorithm without the need for a calibration scan. In images obtained in eight subjects undergoing EPI for auditory functional MRI (fMRI) experiments, N/2 ghost intensity was reduced from 10.3% +/- 2.1% (range: 7.9-14.1%) to 4.5% +/- 0.2% (range: 4.1-4.9%) of parent image intensity, corresponding to a percent reduction in ghost intensity of 54% +/- 9% (range: 43-65%), and the algorithm restored this intensity to the parent image. It provided a significant improvement in image appearance, and increased the correlation coefficients related to neural activation in functional MRI studies. The algorithm provided reduction of artifacts from all polynomial orders of spatial phase errors in both spatial directions. The algorithm did not eliminate N/2 ghost intensity contributed by field inhomogeneities, susceptibility, or chemical shift.

Algorithms↗

UNFOLD using a temporal subtraction and spectral energy comparison technique.

In dynamic MRI, several methods have been demonstrated to increase acquisition speed by decreasing the number of sequential phase encodings. The UNFOLD technique interleaves the measurements of k-space, reconstructs aliased images from each k-space interleaf, and applies a temporal low-pass filter to obtain the nonaliased images. However, low-pass filter resolution of the nonaliased images fails if there is overlap between the spatially aliased temporal spectra. In this study a subtraction method was used to remove the static portion of the image. The aliased and nonaliased dynamic portions are then resolved by comparing the temporal energy of bands in the power spectrum. This method was combined with the 3D 2 x 2 UNFOLD (a factor of 2 interleaves in two directions) technique. The combination resulted in a factor of 4 improvement in acquisition speed. Application of this method to a time-resolved, contrast-enhanced flow phantom study is presented.

Algorithms↗

Detecting determinism in short time series, with an application to the analysis of a stationary EEG recording.

We have developed a new method for detecting determinism in a short time series and used this method to examine whether a stationary EEG is deterministic or stochastic. The method is based on the observation that the trajectory of a time series generated from a differentiable dynamical system behaves smoothly in an embedded phase space. The angles between two successive directional vectors in the trajectory reconstructed from a time series at a minimum embedding dimension were calculated as a function of time. We measured the irregularity of the angle variations obtained from the time series using second-order difference plots and central tendency measures, and compared these values with those from surrogate data. The ability of the proposed method to distinguish between chaotic and stochastic dynamics is demonstrated through a number of simulated time series, including data from Lorenz, Rössler, and Van der Pol attractors, high-dimensional equations, and 1/f noise. We then applied this method to the analysis of stationary segments of EEG recordings consisting of 750 data points (6-s segments) from five normal subjects. The stationary EEG segments were not found to exhibit deterministic components. This method can be used to analyze determinism in short time series, such as those from physiological recordings, that can be modeled using differentiable dynamical processes.

Algorithms↗

A comparison of the high and low backspin backhand drives in tennis using different grips.

Three-dimensional, high-speed cinematography was used to compare backspin backhand techniques of high performance players hitting low (5.4 cm below hip height) and high (41.6 cm above hip height) bouncing balls using their preferred method of holding the racket (eastern backhand or continental grip: hand generally on top of the handle) and non-preferred ('behind the handle') grip. The Direct Linear Transformation method was used for three-dimensional space reconstruction from two-dimensional images recorded from laterally placed phase-locked cameras operating at 200 Hz. The only significant differences (P < 0.05) caused by the change in grip were that the ball was impacted further in front of the body when using the non-preferred grip, and a lower peak racket-shoulder speed was recorded for a high bouncing ball when using the non-preferred grip. Irrespective of the type of grip, the players significantly modified (P < 0.01) their technique to hit a high bouncing ball by adopting a more upright trunk, more rotated shoulder alignment (racket shoulder pointing more towards opponent), a larger front knee angle and a more abducted upper arm. Hitting a high ball was also characterized by a less inclined approach trajectory of the racket, a more vertical racket-face and a different speed profile for the segments of the upper limb and racket.

Acceleration↗