PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “COMPRESSION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.

OBJECTIVES: To examine the biomechanical behavior of 2 techniques of double-plate osteosynthesis for fractures of the adult distal humerus using conventional reconstruction plates and locking compression plates. DESIGN: Basic science study. SETTING: Experimental in vitro study. PATIENTS/PARTICIPANTS: Forty fresh-frozen human distal humeri specimens. INTERVENTION: Four matched groups with 10 humeri each, median age 74 years (46-95), were created using similar bone mineral density values. Two standard configurations of double-plate osteosynthesis (dorsal or 90 degrees configuration) with either conventional reconstruction plates or locking compression plates were studied for biomechanical properties of the constructs. A fracture model with a 5-mm supracondylar osteotomy gap simulating metaphyseal comminution (AO type 13-A3.3) was used. MAIN OUTCOME MEASUREMENT: Stiffness testing of the constructs in anterior/posterior bending, torsion, and axial compression loading. Evaluation of alterations of the bone-implant interface and failure patterns under cyclic loading and strength testing. RESULTS: The study demonstrates that primary stiffness in anterior/posterior bending and torsional loading is significantly increased by using locking compression plates in a 90 degrees configuration (P < 0.05) as compared with dorsally applied plates. The differences between the different plate types are insignificant if applied in the same configuration. It is demonstrated that none of the tested implants failed under cyclic loading within the number of cycles expected for 3 months of use. The bone-implant interface is less likely to fail during strength testing with locking compression plates. CONCLUSION: The biomechanical behavior of the osteosynthesis depends more on plate configuration than plate type. Advantages of locking compression plates are only significant if compared with dorsal plate application techniques. Nevertheless, locking compression plates are helpful supplementary tools for achieving primary stable fracture fixation. This might be of considerable clinical relevance in patients with diminished bone mineral quality or in the presence of metaphyseal comminution.

Aged↗

Axon and ganglion cell injury in rabbits after percutaneous trigeminal balloon compression.

New Zealand white rabbits were used to determine whether the changes in the Vth cranial nerve sensory root after compression were associated with the loss of a specific subclass of Vth cranial nerve ganglion cells, the disappearance of a distinct subset of primary afferent terminals in Vth cranial nerve nucleus caudalis, and/or injury to a specific axonal fiber type. There was no significant difference in the size of surviving ganglion cells after Vth cranial nerve compression, as measured 2 to 3 months after injury (P > 0.5, n = 4). Densitometric analysis of the nerves of rabbits that survived > 2 months after compression showed no significant difference in the immunoreactivity of substance P and calcitonin gene-reactive protein between compressed and control sides (P > 0.1, n = 4). Fink-Heimer staining of the Vth cranial nerve subnucleus caudalis revealed that transganglionic degeneration was most dense in the deeper layers, which are the sites of termination of large myelinated fibers. Ultrastructural evaluation of the type of myelinated axons injured by Vth cranial nerve compression in rabbits killed 7, 14, 37, and 270 days after injury was studied, and morphometric analysis was performed. The frequency distribution of axon diameters was significantly different for injured and control areas. The injured areas had higher ratios of small (< 3-microns diameter) to large-diameter axons compared to control distribution. These data indicate that balloon compression results in loss of fibers from the Vth cranial nerve sensory root and extensive transganglionic degeneration in the Vth cranial nerve brain stem complex. Cell size measurements and immunocytochemical data suggest that there is no specific loss of small ganglion cells or fine-caliber primary afferents. These experiments suggest that balloon compression relieves trigeminal pain by injuring the myelinated axons involved in the sensory trigger to the pain.

Afferent Pathways↗

Placental compressibility: implications for indirect diagnosis of posterior placenta previa.

A number of problems beset the indirect diagnosis of posterior placenta previa using transabdominal ultrasound. We add a new potential complicating factor. In 128 pregnancies at or beyond 30 weeks' gestation, measurements were taken from the fetal skull to the maternal sacrum before and after compression. Up to 69% compressibility of the placenta was found in vivo and in vitro. Modified fetal skull to maternal sacrum measurement criteria were devised from the results. Placenta previa is highly unlikely if the measurement from the fetal skull to maternal sacrum is less than 10 mm before compression or less than 7 mm after compression. Placenta previa is probable if the measurement is greater than 20 mm before compression or greater than 15 mm after compression. In 40% of the cases, posterior placenta previa could not be excluded. We conclude that placental compressibility is an additional confounding problem for indirect ultrasound assessment of posterior placenta previa and that indirect assessment should be attempted only if maneuvers to image the lower uterine segment directly are unsuccessful.

Female↗

Spatial compression and adaptation with the low vision telescope.

PURPOSE: Geometrical analysis of monocular visual information specifying distance shows that a low vision telescope compresses optically specified distances by a factor about equal to its magnification. Using a group of eight visually healthy adults, we investigated the initial perceptual effect of putting on a 2x Galilean telescope and the adaptation produced by wearing the telescope. METHODS: Viewing was monocular, and the environment was only visible through the telescope. Because the telescope reduced the field of view to 13 degrees , we also tested a different group of eight visually normal adults who wore a simple monocular tube that restricted the field of view to 13 degrees . We measured perceived distance in a corridor using a visually directed open-loop walking task with distances ranging from 4 to 8 m. For both groups, monocular distance perception was measured before putting on the viewing device (baseline), immediately after putting on the viewing device (preadaptation), after wearing the viewing device during a 30-minute period of visual-motor activities (postadaptation), and immediately after taking off the viewing device (aftereffect). RESULTS: Comparing preadaptation with baseline measurements, the viewing devices produced a 15.4% initial compression of perceived distance on average. Comparing aftereffect with baseline measurements, the adaptation period produced a negative aftereffect that was 56.5% of the initial compression, thus showing substantial adaptation. The initial compression and the adaptation were highly significant effects, but neither effect was significantly different for the telescope group and the tube group. CONCLUSION: We conclude that free head movements in a structured environment can largely overcome the optically specified compression of distance produced by the 2x magnification of a low vision telescope, but there remains a significant initial compression of perceived distance that is produced by the restricted field of view. This compression can be substantially reduced by a short period of interaction with the environment.

Adaptation, Physiological↗

Nonlinear response analysis of the human ligamentous lumbar spine in compression. On mechanisms affecting the postural stability.

Basic questions regarding how extreme compressive loads can be tolerated by the spine without experiencing abnormal motions or instabilities remain unresolved. Two finite element models of the human lumbar spine were generated. The detailed model accounted for the three-dimensional irregular geometry, material and geometric nonlinearities, nonhomogeneous fiber-matrix nature of the discs, ligaments, and articulation at the facet joints. The nonlinear stability response of the model was predicted under an axial compression force (200 N to 700 N) applied at the L1 while the S1 was fixed. The effect of the presence of a combined flexion moment and a horizontal support on the response was investigated. Another nonlinear model using rigid bodies interconnected by deformable beam elements was also considered. The computed results under the axial compression loads indicated that the response is highly nonlinear with no bifurcation or limit point (critical load). The unconstrained lumbar spine is most flexible in the sagittal plane (least stiff plane). The existence of the horizontal support and the combined flexion moment significantly increased the load-bearing capacity of the lumbar spine; the lumbar spine resisted the axial compression force of 400 N with minimal displacements. Under axial compression force, the flexion moment tends to restrict the posterior translational movement of the lordotic lumbar spine, whereas the horizontal support constrains the coupled lateral motion. A slight decrease in the lordosis was predicted for the compression load of 400 N. It is postulated that the anterior location of the line of gravity of the upper-body weight is regulated to provide the required combined loads on the lumbar spine so higher compression can be tolerated by the spine at minimal energetic cost. In vivo experimental results support the validity of the model predictions.

Aged↗

Muscle activity and low back loads under external shear and compressive loading.

STUDY DESIGN: This study analyzed anatomic and neural control characteristics of the trunk musculature. Subjects were exposed to external shear and compressive loads with equivalent moments to evaluate activation patterns and loading on the low back. OBJECTIVES: The migration of activity between the thoracic and lumbar erector spinae muscle groups was examined to determine whether the motor control system chooses to minimize joint loading by recognizing differences in moment, compression, and shear support requirements and assigning muscle activation in the most appropriate way. SUMMARY OF BACKGROUND DATA: Loads were applied either parallel or perpendicular to the low back to create compressive or shear forces. No previous study has attempted to isolate the response of the trunk musculature with the type of external load. METHODS: Eleven male subjects isometrically held an external load that was altered to create either a compressive or an anterior shear load on the low back but with equal extensor (reaction) moments (experiment 1). In a second experiment four men repeated the task with an increased range of applied loads (5-25 kg) together with measurements of intra-abdominal pressure. RESULTS: The tasks with a compressive external load resulted in significantly higher levels of activation for all seven electromyographic channels recorded. Intraabdominal pressure, compressive and shear joint forces were all higher in the compression loading method when equal loads and low back moments were compared. CONCLUSIONS: It was concluded that the motor control system does not arrange muscle activation levels in a way to minimize lumbar spinal loading at least for the relatively low levels of this study. Biomechanical models that use the objective criterion of minimum joint load may not be representative of the motor control system, at least in the low back.

Abdominal Muscles↗

Limited usefulness of traction-compression films in the radiographic diagnosis of lumbar spinal instability. Comparison with flexion-extension films.

STUDY DESIGN: A prospective, within-patient comparison of two methods for functional radiography of lumbar spine with consecutive patients. OBJECTIVE: To evaluate the usefulness of traction-compression radiography compared with conventional flexion-extension radiography in diagnosis of lumbar spinal instability. SUMMARY OF BACKGROUND DATA: Flexion-extension radiography generally is used and widely recognized as an effective method for diagnosis of segmental lumbar spinal instability, but the usefulness and findings of traction-compression films are less well known. METHODS: Flexion-extension and traction-compression radiography were performed on 306 consecutive patients (mean age, 43 years; range, 14-68 years) with clinically suspected lumbar spinal instability. Radiography was performed of each patient in an upright position. Axial traction was accomplished by letting the patient hang by his or her hands from a horizontal bar. Compression views were taken when the patient had sandbags of approximately 30% of the his or her weight on the shoulders. Main interest was translational forward and backward displacement of one vertebra on another. RESULTS: Signs of translational instability were present on the functional radiographs of 27% (84 of 306) of the patients. In diagnosis of instability, the overall agreement of flexion-extension and traction-compression films was only 0.786, and also statistic Kappa remained poor (0.05). Flexion-extension films more frequently revealed signs of instability than traction-compression films: 81 versus seven patients. CONCLUSIONS: Traction-compression films seem to be of questionable value in diagnosis of lumbar spinal instability.

Adolescent↗

Compression-induced changes in intervertebral disc properties in a rat tail model.

STUDY DESIGN: An Ilizarov-type apparatus was applied to the tails of rats to assess the influence of immobilization, chronically applied compression, and sham intervention on intervertebral discs of mature rats. OBJECTIVES: To test the hypothesis that chronically applied compressive forces and immobilization cause changes in the biomechanical behavior and biochemical composition of rat tail intervertebral discs. SUMMARY OF BACKGROUND DATA: Mechanical factors are associated with degenerative disc disease and low back pain, yet there have been few controlled studies in which the effects of compressive forces on the structure and function of the disc have been isolated. METHODS: The tails of 16 Sprague-Dawley rats were instrumented with an Ilizarov-type apparatus. Animals were separated into sham, immobilization, and compression groups based on the mechanical conditions imposed. In vivo biomechanical measurements of disc thickness, angular laxity, and axial and angular compliance were made at 14-day intervals during the course of the 56-day experiment, after which discs were harvested for measurement of water, proteoglycan, and collagen contents. RESULTS: Application of pins and rings alone (sham group) resulted in relatively small changes of in vivo biomechanical behavior. Immobilization resulted in decreased disc thickness, axial compliance, and angular laxity. Chronically applied compression had effects similar to those of immobilization alone but induced those changes earlier and in larger magnitudes. Application of external compressive forces also caused an increase in proteoglycan content of the intervertebral discs. CONCLUSIONS: The well-controlled loading environment applied to the discs in this model provides a means of isolating the influence of joint-loading conditions on the response of the intervertebral disc. Results indicate that chronically applied compressive forces, in the absence of any disease process, caused changes in mechanical properties and composition of tail discs. These changes have similarities and differences in comparison with human spinal disc degeneration.

Animals↗

Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.

STUDY DESIGN: An Institutional Review Board-approved Phase I efficacy study of inflatable bone tamp usage in the treatment of symptomatic osteoporotic compression fractures. OBJECTIVES: To evaluate the safety and efficacy of inflatable bone tamp reduction and cement augmentation, "kyphoplasty," in the treatment of painful osteoporotic vertebral compression fractures. SUMMARY OF BACKGROUND DATA: Osteoporotic compression fractures can result in progressive kyphosis and chronic pain. Traditional treatment for these patients includes bed rest, analgesics, and bracing. Augmentation of vertebral compression fractures with polymethylmethacrylate, "vertebroplasty," has been used to treat pain. This technique, however, makes no attempt to restore the height of the collapsed vertebral body. Kyphoplasty is a new technique that involves the introduction of inflatable bone tamps into the vertebral body. Once inflated, the bone tamps restore the vertebral body back toward its original height while creating a cavity that can be filled with bone cement. PATIENTS AND METHODS: Seventy consecutive kyphoplasty procedures were performed in 30 patients. The indications included painful primary or secondary osteoporotic vertebral compression fractures. Mean duration of symptoms was 5.9 months. Symptomatic levels were identified by correlating the clinical data with MRI findings. Perioperative variables and bone tamp complications or issues were recorded and analyzed. Preoperative and postoperative radiographs were compared to calculate the percentage height restored. Outcome data were obtained by comparing preoperative and latest postoperative SF-36 data. RESULTS: At the completion of the Phase I study there were no major complications related directly to use of this technique or use of the inflatable bone tamp. In 70% of the vertebral bodies kyphoplasty restored 47% of the lost height. Cement leakage occurred at six levels (8.6%).SF-36 scores for Bodily Pain 11.6-58.7, (P = 0.0001) and Physical Function 11.7-47.4, (P = 0.002) were among those that showed significant improvement. CONCLUSIONS: The inflatable bone tamp was efficacious in the treatment of osteoporotic vertebral compression fractures. Kyphoplasty is associated with early clinical improvement of pain and function as well as restoration of vertebral body height in the treatment of painful osteoporotic compression fractures.

Aged↗

Effect of supplemental translaminar facet screw fixation on the stability of stand-alone anterior lumbar interbody fusion cages under physiologic compressive preloads.

STUDY DESIGN: A biomechanical study of lumbar threaded interbody cage construct under varying compressive preloads of similar magnitudes to those experienced in vivo during daily activities. OBJECTIVES: To test the hypothesis that supplemental translaminar facet screws would enhance the stability (ability to reduce segmental angular motion) of threaded interbody cages in flexion-extension during activities in which the spine is subjected to low compressive preloads, and therefore the stand-alone interbody cage construct is least stable. SUMMARY OF BACKGROUND DATA: Controversy exists over whether threaded anteriorly placed interbody cages can be routinely used as "stand-alone" devices or whether they require supplemental posterior stabilization to achieve successful fusion. Biomechanical studies suggest that under conditions of low preloads, the motion segment treated with stand-alone cages might be less stable, particularly in extension. METHODS.: Eight human lumbar spine specimens (from L1 to sacrum) were tested intact, after insertion of 2 threaded cylindrical cages (BAK) at L5-S1 and after supplemental translaminar facet screw fixation. They were subjected to flexion and extension moments under progressively increasing magnitude of externally applied compressive follower preload from 0 to 1200 N. The range of angular motion in flexion-extension at L5-S1 was analyzed to assess the effect of translaminar facet screws on the stability of the cage construct for different compressive preloads. RESULTS: In flexion, over 0 to 400 N preload, the supplemental translaminar facet screw fixation reduced the L5-S1 angular motion relative to intact by 71% to 74% as compared to 40% to 44% for the cages alone. This difference was statistically significant (P < 0.05). In extension at 0 N preload, the cages allowed more angular motion than the intact segment, whereas with translaminar facet screw fixation, the motion was reduced to the level of the intact segment. At 400 N preload, supplemental TLFS fixation significantly increased the stability of the cages, reducing the extension angular motion by 60% of intact (P = 0.04). Supplemental translaminar facet screw fixation did not significantly increase the stability provided by the cages in flexion or extension at the 1200 N preload magnitude. CONCLUSIONS: In vivo during activities of daily living, interbody cage constructs are subject to varying compressive preloads due to external loads generated by paraspinal musculature, and our results suggest that the stability created by the cage (reduction in segmental angular motion) is not constant. The cage construct is likely to be least stable in extension during activities that impart low compressive preloads to the lumbar spine. Supplemental translaminar facet screw fixation will enhance stability of the motion segment treated with threaded cages, particularly during conditions of low compressive preloads, the very condition in which the cage alone is least effective in providing stability.

Adult↗

Evidence-based compression: prevention of stasis and deep vein thrombosis.

OBJECTIVE: To summarize the currently published scientific evidence for the venous flow effects of mechanical devices, particularly intermittent pneumatic compression, and the relation to prevention of deep vein thrombosis (DVT). SUMMARY BACKGROUND DATA: While intermittent pneumatic compression is an established method of DVT prophylaxis, the variety of systems that are available can use very different compression techniques and sequences. In order for appropriate choices to be made to provide the optimum protection for patients, the general performance of systems, and physiological effects of particular properties, must be analyzed objectively. METHODS: Medline was searched from 1970 to 2002, and all relevant papers were searched for further appropriate references. Papers were selected for inclusion when they addressed specifically the questions posed in this review. RESULTS: All the major types of intermittent compression systems are successful in emptying deep veins of the lower limb and preventing stasis in a variety of subject groups. Compression stockings appear to function more by preventing distension of veins. Rapid inflation, high pressures, and graded sequential intermittent compression systems will have particular augmentation profiles, but there is no evidence that such features improve the prophylactic ability of the system. CONCLUSIONS: The most important factors in selecting a mechanical prophylactic system, particularly during and after surgery, are patient compliance and the appropriateness of the site of compression. There is no evidence that the peak venous velocity produced by a system is a valid measure of medical performance.

Bandages↗

Electrorheological fluid under elongation, compression, and shearing.

Electrorheological (ER) fluid based on zeolite and silicone oil under elongation, compression, and shearing was investigated at room temperature. Dc electric fields were applied on the ER fluid when elongation and compression were carried out on a self-constructed test system. The shear yield stress, presenting the macroscopic interactions of particles in the ER fluid along the direction of shearing and perpendicular to the direction of the electric field, was also obtained by a HAAKE RV20 rheometer. The tensile yield stress, presenting the macroscopic interactions of particles in the ER fluid along the direction of the electric field, was achieved as the peak value in the elongating curve with an elongating yield strain of 0.15-0.20. A shear yield angle of about 15 degrees -18.5 degrees reasonably connected tensile yield stress with shear yield stress, agreeing with the shear yield angle tested well by other researchers. The compressing tests showed that the ER fluid has a high compressive modulus under a small compressive strain lower than 0.1. The compressive stress has an exponential relationship with the compressive strain when it is higher than 0.1, and it is much higher than shear yield stress.

Journal Article↗

Data compression for diffraction patterns.

Efficient coding (lossless) and compression (lossy) of diffraction patterns is important in protein crystallography experiments because of storage and transmission limitations. The goal is to reduce the bit-rate significantly while keeping diffraction peak intensity distortion at an acceptable level. This paper presents an overview of coding and compression techniques more or less adapted to such problems. A large part of this study is dedicated to time-frequency-transform based compression algorithms and some of their extensions. Wavelet based software has been developed and tested. Results are compared with the discrete cosine transform (DCT) and other classical algorithms. These tools seem attractive and very promising for analyzing and compressing signals with singularities and transient phenomena such as diffraction peaks. Tests were performed on a standard protein crystallography data set coming from the CCD detector of D2AM beamline at the European Synchrotron Radiation Facility at Grenoble. These were compressed with DCT and wavelet-based algorithms. It appears that alterations of the result of the processing of restored images remain very weak for compression rates up to 10. These preliminary results indicate that the proposed wavelet method is a good standard technique for efficient compression of diffraction patterns.

Algorithms↗

EEG data compression techniques.

In this paper, electroencephalograph (EEG) and Holter EEG data compression techniques which allow perfect reconstruction of the recorded waveform from the compressed one are presented and discussed. Data compression permits one to achieve significant reduction in the space required to store signals and in transmission time. The Huffman coding technique in conjunction with derivative computation reaches high compression ratios (on average 49% on Holter and 58% on EEG signals) with low computational complexity. By exploiting this result a simple and fast encoder/decoder scheme capable of real-time performance on a PC was implemented. This simple technique is compared with other predictive transformations, vector quantization, discrete cosine transform (DCT), and repetition count compression methods. Finally, it is shown that the adoption of a collapsed Huffman tree for the encoding/decoding operations allows one to choose the maximum codeword length without significantly affecting the compression ratio. Therefore, low cost commercial microcontrollers and storage devices can be effectively used to store long Holter EEG's in a compressed format.

Algorithms↗

Dynamic image data compression in spatial and temporal domains: theory and algorithm.

Advanced medical imaging requires storage of large quantities of digitized clinical data. These data must be stored in such a way that their retrieval does not impair the clinician's ability to make a diagnosis. In this paper, we propose the theory and algorithm for near (or diagnostically) lossless dynamic image data compression. Taking advantage of domain-specific knowledge related to medical imaging, the medical practice and the dynamic imaging modality, a compression ratio greater than 80:1 is achieved. The high compression ratios are achieved by the proposed compression algorithm through three stages: 1) addressing temporal redundancies in the data through application of image optimal sampling, 2) addressing spatial redundancies in the data through cluster analysis, and 3) efficient coding of image data using standard still-image compression techniques. To illustrate the practicality of the proposed compression algorithm, a simulated positron emission tomography (PET) study using the fluoro-deoxy-glucose (FDG) tracer is presented. Realistic dynamic image data are generated by "virtual scanning" of a simulated brain phantom as a real PET scanner. These data are processed using the conventional [8] and proposed algorithms as well as the techniques for storage and analysis. The resulting parametric images obtained from the conventional and proposed approaches are subsequently compared to evaluate the proposed compression algorithm. As a result of this study, storage space for dynamic image data is able to be reduced by more than 95%, without loss in diagnostic quality. Therefore, the proposed theory and algorithm are expected to be very useful in medical image database management and telecommunication.

Algorithms↗

Optimal zonal wavelet-based ECG data compression for a mobile telecardiology system.

A new integrated design approach for an optimal zonal wavelet-based ECG data compression (OZWC) method for a mobile telecardiology model is presented. The hybrid implementation issues of this wavelet method with a GSM-based mobile telecardiology system are also introduced. The performance of the mobile system with compressed ECG data segments selected from the MIT-BIH arrhythmia data base is evaluated in terms of bit error rate (BER), percent rms difference (PRD), and visual clinical inspection. The compression performance analysis of the OZWC is compared with another wavelet-based (Discrete Symmetric Wavelet Compression) approach. The optimal wavelet algorithm achieved a maximum compression ratio of 18: 1 with low PRD ratios. The mobile telemedical simulation results show the successful compressed ECG transmission at speeds of 100 (km/h) with BER rates of less than 10(-15), providing a 73% reduction in total mobile transmission time with clinically acceptable reconstruction of the received signals. This approach will provide a framework for the design and functionality issues of GSM-based wireless telemedicine systems with wavelet compression techniques and their future integration for the next generation of mobile telecardiology systems.

Cardiology↗

Class-3c compression bandaging for venous ulcers: comparison of spiral and figure-of-eight techniques.

AIM: This paper reports a study to compare the differences in compression produced on a limb using a spiral and a figure-of-eight bandaging technique. BACKGROUND: Chronic leg ulcers are a major health problem in Western countries. Compression bandaging is the accepted treatment for venous leg ulcers. The spiral and the figure-of-eight techniques are traditional methods of applying compression bandages. But their performance in terms of pressure profiles is unknown. Despite a lack of evidence about technique, class-3c compression bandages are not currently recommended for application in a figure-of-eight as this is thought to produce dangerously high pressure. METHODS: A cross-over experimental design was used with a sample of 26 nurse bandagers. Consistency of performance was tested. Bandage stretch and overlap were measured and analysed by standard deviation to ensure that the techniques were consistent and repeatable. Pressure probes were then applied to the medial, posterior and lateral aspects of the lower limb of a healthy volunteer. The class-3c compression bandage was applied using both techniques and the pressure profiles around the leg were measured under the bandage. The results of each technique were compared using independent sample t-tests. The data were collected in 1999. RESULTS: The figure-of-eight technique provided statistically significantly higher compression at lower areas of the leg than the spiral technique. Mean pressure difference was 20.3 mmHg at the ankle, 22.2 mmHg at the gaiter, 9.4 mmHg at the calf. The pressure differences decrease towards the knee with both techniques and decrease more steeply with the figure-of-eight technique. CONCLUSION: The spiral technique was a safe and comfortable method of bandage application. The figure-of-eight also provided graduated compression but with some high areas of pressure, notably overlying the Achilles tendon. However, before firm practice recommendations are made, replication of the study using a padding layer and a larger sample is needed.

Bandages↗

The effect of compression therapy on venous haemodynamics in pregnant women.

OBJECTIVE: To study the influence of compression on the haemodynamics of the deep venous system in pregnancy. DESIGN: A prospective, observational study. SETTING: The phlebological unit of the department of dermatology at a university hospital. POPULATION: Fifteen pregnant women with no previous signs of chronic venous insufficiency. METHODS: Parameters of the venous pump function were assessed by strain-gauge plethysmography. Blood flow velocity, flow volume and vessel diameter in the superficial femoral vein were measured by duplex sonography. All examinations were performed with and without applied compression stockings (25-32 mmHg) at two different stages of gestation and after delivery. In addition, subjective symptoms were graded. RESULTS: Venous pump function improved and refilling time lengthened significantly when compression was used during gestation and postnatally. Duplex sonography showed an increase in blood flow velocity and flow volume in the superficial femoral vein with applied compression; the vessel diameter increased slightly. Subjective symptoms of the leg, graded on an arbitrary scale, were reduced by regular compression therapy. CONCLUSION: Our results indicate that compression improves the clinical symptoms of venous congestion and the venous haemodynamics of the legs during pregnancy and in the postpartum period. Thus, the regular use of compression during pregnancy and the puerperium may reduce the incidence of thromboembolic events.

Bandages↗