PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Mechanical and structural model of fractal networks of fat crystals at low deformations.

Fat-crystal networks demonstrate viscoelastic behavior at very small deformations. A structural model of these networks is described and supported by polarized light and atomic-force microscopy. A mechanical model is described which allows the shear elastic modulus (G') of the system to be correlated with forces acting within the network. The fractal arrangement of the network at certain length scales is taken into consideration. It is assumed that the forces acting are due to van der Waals forces. The final expression for G' is related to the volume fraction of solid fat (Phi) via the mass fractal dimension (D) of the network, which agrees with the experimental verification of the scaling behavior of fat-crystal networks [S. S. Narine and A. G. Marangoni, Phys. Rev. E 59, 1908 (1999)]. G' was also found to be inversely proportional to the diameter of the primary particles (sigma approximately equal to 6 microm) within the network (microstructural elements) as well as to the diameter of the microstructures (xi approximately equal to 100 microm) and inversely proportional to the cube of the intermicrostructural element distance (d(0)). This formulation of the elastic modulus agrees well with experimental observations.

Journal Article↗

Hypertonic saline resuscitation prevents hydrostatically induced intestinal edema and ileus.

OBJECTIVE: We have shown that acute edema induced by mesenteric venous hypertension (MV-HTN) impairs intestinal transit and reduces the standardized engineering measures of intestinal stiffness (elastic modulus) and residual stress (opening angle). We hypothesized that hypertonic saline (7.5%) would reverse these detrimental effects of acute edema. DESIGN: Laboratory study. SETTING: University laboratory. SUBJECTS: Male Sprague Dawley rats (270-330 g). INTERVENTIONS: Rats were randomized to five groups: sham, MV-HTN alone, MV-HTN with 4 mL/kg normal saline resuscitation (equal volume), MV-HTN with 33 mL/kg normal saline resuscitation (equal salt), and MV-HTN with 4 mL/kg hypertonic saline. Intestinal edema was measured by wet to dry tissue weight ratio. A duodenal catheter was placed and, 30 mins before death, fluorescein isothiocyanate Dextran was injected. At death, dye concentrations were measured to determine intestinal transit. Segments of distal ileum were hung to a fixed point in a tissue bath and to a force displacement transducer and stretched in increments of 1 mm; we recorded the new length and the corresponding force from the force displacement transducer to determine elastic modulus. Next, two transverse cuts were made yielding a 1- to 2-mm thick ring-shaped segment of tissue which was then cut radially to open the ring. Then the opening angle was measured. MEASUREMENTS AND MAIN RESULTS: MV-HTN, MV-HTN with 4 mL/kg normal saline, and MV-HTN with 33 mL/kg normal saline caused a significant increase in tissue edema and a significant decrease in intestinal transit, stiffness, and residual stress compared with sham. Hypertonic saline significantly lessened the effect of edema on intestinal transit and prevented the changes in stiffness and residual stress. CONCLUSIONS: Hypertonic saline prevented intestinal tissue edema. In addition, hypertonic saline improved intestinal transit, possibly through more efficient transmission of muscle force through stiffer intestinal tissue.

Animals↗

Determination of the elastic shear modulus of cultured human red blood cells.

In this study we investigated the mechanical properties of in vitro cultured red blood cells (RBCs) in a liquid system. We used human umbilical cord blood as a highly efficient source of hematopoietic stem cells (HS). Our first goal was to establish an optimal medium composition in order to yield finally differentiated RBCs, i.e. enucleated and hemoglobin-filled cells. Different stages of cell differentiation were distinguished based on morphological observations and flow cytometry measurements. By means of the micropipette aspiration technique we estimated the deformability characteristics of the cultured cells. Up to the stage of oxiphilic normoblasts they readily deformed. Reticulocytes and mature RBCs showed an enhanced stiffness as compared to RBCs obtained from donors.

Adult↗

Listeria monocytogenes inhibition by whey protein films and coatings incorporating lysozyme.

The effects of whey protein isolate (WPI) films and coatings incorporating lysozyme (LZ) on the inhibition of Listeria monocytogenes both in and on microbial media, as well as on cold-smoked salmon, were studied. The antimicrobial effects of LZ were examined using various growth media by turbidity and plate counting tests. Disc-covering and disc-surface-spreading tests were also used to evaluate the effects of WPI films incorporating LZ. Smoked salmon was used as a model food to test the antimicrobial effects of WPI coatings incorporating LZ, both initially and during storage at 4 and 10 degrees C for 35 days. Tensile properties (elastic modulus, tensile strength, and percentage of elongation), oxygen permeability, and color (Hunter L, a, and b) of WPI films with and without LZ were also compared. LZ inhibited L. monocytogenes in broth and on agar media. The number of cells surviving after LZ treatments depended on the type of media. WPI films incorporating 204 mg of LZ per g of film (dry basis) inhibited the growth of a preparation of 4.4 log CFU/cm2 L. monocytogenes. WPI coatings prepared with 25 mg of LZ per g of coating solution initially inactivated more than 2.4, 4.5, and 3.0 log CFU/g of L. monocytogenes, total aerobes, and yeasts and molds in smoked salmon samples, respectively. The WPI coatings incorporating LZ efficiently retarded the growth of L. monocytogenes at both 4 and 10 degrees C. The anti-L. monocytogenes effect of LZ-WPI coating was more noticeable when the coating was applied before inoculation than when the coating was applied after inoculation. Significantly higher elastic modulus values and lower percentage of elongation and oxygen permeability values were measured with the WPI films incorporating LZ than with the plain WPI films.

Animals↗

Influence of glass-ceramic thickness on Hertzian and bulk fracture mechanisms.

PURPOSE: The objective of this study was to test the hypothesis that bulk fracture of glass-ceramic disks of variable thickness originates at the inner, resin-bonded surface and is dominant over Hertzian fracture at the lower range of thickness values. MATERIALS AND METHODS: Eight groups of seven glass-ceramic disks (Dicor, Dentsply), 12 mm in diameter with thicknesses ranging from 0.4 to 2.4 mm, were cast, cerammed (to produce approximately 55 vol% of tetrasilicic fluormica crystals), air abraded, etched, and silane coated according to the manufacturer's instructions. The disks were bonded to an epoxy die substrate (with an elastic modulus comparable to that of dentin) using a light-activated resin cement. The bonded samples were supported on a flat surface and loaded at the top center of each disk until crack initiation occurred. All disks exhibited an initial crack within the bonded surface. Three randomly selected samples for each thickness were loaded beyond the point of crack initiation until Hertzian failure occurred. RESULTS: Although the crack-initiation force increased with increasing thickness, the failure stress approached a maximum level at a thickness of approximately 1.6 mm. These results suggest that the estimated maximum occlusal load for each patient should be used to select the minimum thickness of ceramic crowns rather than using the arbitrary traditional selection of a 1.5-mm thickness. CONCLUSIONS: The authors conclude that bulk fracture is initiated within the bonded surface of a glass-ceramic specimen (for samples 0.4 to 2.4 mm in thickness) when the glass-ceramic is supported by a substrate with an elastic modulus similar to that of dentin. Furthermore, a Hertzian failure mechanism is unlikely to cause bulk fracture for these conditions.

Dental Porcelain↗

Enamel structure properties controlled by engineered proteins in transgenic mice.

UNLABELLED: Amelogenin protein has regulatory effects on enamel biofabrication in mammalian tooth. Using teeth obtained from transgenic mice that express two separate protein-engineered versions of amelogenins, we made structure-nanomechanical properties correlations and showed 21% hardness and 24% elastic modulus degradation compared with the age-matched wildtype littermates. We attribute the inferior properties to the disorganization of the protein matrix resulting in defective mineral formation. INTRODUCTION: Enamel is a bioceramic initiated by the biosynthesis of a complex mixture of proteins that undergoes self-assembly to produce a super molecular ensemble that controls the nucleation and habit of the crystalline mineral phase. Ultimately, the inorganic crystals grow to almost fully replace the organic phase. This biofabrication process occurs at physiologic conditions of pH, temperature, pressure, and ion concentration and results in the hardest tissue in the vertebrate body, with the largest and longest substituted-hydroxyapatite crystals known to biomineralizing systems. The most abundant protein of forming mammalian enamel, amelogenin, has been shown to have a significant regulatory effect on this complex process. MATERIALS AND METHODS: In this work, we present the effect of protein engineering of amelogenin on the mechanical properties of the resultant mouse enamel. We have produced two types of transgenic animals that express separate versions of amelogenin proteins that lack the required self-assembly domains. The resultant matured enamel was extensively characterized for its mechanical properties at the nanoscale by means of nanoindentation and atomic force microscopy (AFM). These techniques have enabled us to probe the mechanical properties that are representative of a single enamel rod. RESULTS: Our nanoindentation measurements have revealed that the altered amelogenin with dysfunctional self-assembly properties resulted in a degradation by as much as 21% in hardness and 24% in elastic modulus compared with the age-matched wildtype littermates. Furthermore, the enamel formed by these defective proteins is found to display a decrease in indentation surface pile-up volume by up to 32%. CONCLUSIONS: We attribute these inferior mechanical properties for the enamel grown by the engineered amelogenins to result from the disorganization of the nanospheres formed in the protein matrix starting at the mineral nucleation stage with a consequential alteration to the fully grown mineral component. By engineering the properties of proteins that contribute to the nanoscale level of hierarchy in enamel biomineralization, it is possible to regulate the properties of the resulting bioceramic at the mesoscale level of the tissue.

Amelogenin↗

Aortic compliance following EVAR and the influence of different endografts: determination using dynamic MRA.

PURPOSE: To utilize dynamic magnetic resonance angiography (MRA) to characterize aortic stiffness (beta) and elastic modulus (Ep) as indexes of wall compliance during the cardiac cycle and determine any influence of different endograft designs or the presence of endoleaks on these indexes. METHODS: Eleven consecutive patients (11 men; median age 74 years, range 63-78) with abdominal aortic aneurysm (AAA) selected for endovascular repair were scanned pre- and postoperatively. Aortic area and diameter changes during the cardiac cycle were determined using dynamic MRA at 4 levels: 3 cm above the renal arteries, between the renal arteries, 1 cm below the renal arteries, and at the level of maximum aneurysm sac diameter. Ep and beta were calculated. Data are presented as median (range); p<0.05 was considered significant. RESULTS: Preoperatively, Ep and beta were significantly higher at the level of the aneurysm sac compared to all other levels (p<0.05). Following EVAR, stiffness increased at this level (p<0.05). After implantation, patients with an Excluder endograft demonstrated Ep and beta measurements at the aneurysm neck that were 94% and 60% higher, respectively, compared to those with a Talent (p<0.05) endograft. The presence of an endoleak had no effect on Ep or beta. CONCLUSION: This study introduces the feasibility of dynamic MRA imaging-based calculations of aortic elastic modulus and stiffness. AAA patients demonstrate increased Ep and beta at the level of the aneurysm sac. EVAR results in increased aneurysm sac Ep and beta. Stent-graft design seems to alter Ep and beta within the aneurysm neck, which may have consequences for endograft durability. The presence of an endoleak does not seem to have an effect on Ep or beta.

Aged↗

Enhanced intrinsic biomechanical properties of osteoblastic mineralized tissue on roughened titanium surface.

The biological mechanisms underlying bone-titanium integration and biomechanical properties of the integrated bone are poorly understood. This study assesses intrinsic biomechanical properties of mineralized tissue cultured on titanium having different surface topographies. The osteoblastic phenotypes associated with mineral deposition and collagen synthesis underlying the biomechanical modulation are also reported. Rat bone marrow-derived osteoblastic cells were cultured either on the machined titanium disc or acid-etched titanium disc. Nano-indentation study of day 28 culture revealed that the mineralized tissue on the acid-etched surface shows 3-3.5 times greater hardness than that on the machined surface (p < 0.01). Elastic modulus of the mineralized tissue was also 2.5-3 times greater on the acid-etched surface than on the machined surface (p < 0.01). After 28 days of culture, mineralized nodule area was significantly lower on the acid-etched surface than on the machined surface (p = 0.0105), while total calcium deposition did not differ between the two surfaces, indicating denser mineral deposition on the acid-etched surface. Osteopontin and osteocalcin gene expressions assayed by the reverse transcriptase-polymerase chain reaction were upregulated in the acid-etched titanium culture. Collagen synthesis measured by Sirius red stain-based colorimetry was 1.5-10 times higher on the acid-etched surface than on the machined surface in the initial culture period of day 1 to day 14 (p < 0.0001). The amount of collagen synthesis corresponded with the enhanced gene expression of prolyl 4-hydroxylase, a key enzyme for post-translational modification of collagen chains. Scanning electron microscopic images revealed that tissue cultured on the acid-etched titanium exhibited plate-like, compact surface morphology, while the tissue on the machined titanium appeared porous and was covered by fibrous and punctate structures. We conclude that culturing osteoblasts on rougher titanium surfaces enhances hardness and elastic modulus of the mineralized tissue, associated with condensed mineralization, accelerated collagen synthesis, and upregulated expression of selected bone-related genes.

Animals↗

The influence of fibrin polymerization and platelet-mediated contractile forces on citrated whole blood thromboelastography profile.

Thromboelastography analysis providing a global assessment of coagulation is gaining new interest in clinical practice. MinimalTF triggered whole blood thromboelastography provides a valuable tool for studying the kinetics of clot formation (expressed by the parameters R, K and alpha-angle) and the physical characteristics of the clot, such as its firmness and the elastic modulus shear (expressed by the parameters maximal amplitude MA and G). We studied the influence of fibrin polymerization and platelet functional status on each parameter of thromboelastographic trace obtained by minimalTF activation inWB by employing increasing concentrations of a fibrin polymerization inhibitors (the tetrapeptide Gly-Pro-Arg-Pro-OH.AcOH; Pefabloc-FG) and an inhibitor of actin polymerization (Cytochalasin D). Pefabloc-FG at concentrations higher than 5 mg/ml prolonged the R and K times and decreased the alpha-angle in a concentration-dependent manner but it did not modify MA and G parameters. At the concentration of 5 mg/ml, Pefabloc-FG completely inhibited clot formation. Cytochalasin D had no effect on R time but decreased the alpha-angle, MA and G parameters by reaching a plateau at the concentration of 5 microM. The effect of cytochalasin D was more pronounced on MA and G than on the alpha-angle. A combination of both Pefabloc-FG (0.5 mg/ml) and cytochalasin D (50 microM) significantly decreased alpha-angle compared to control as well as their single effect. However, G value was dramatically reduced in the presence of cytochalasin D exposure, without any additional effect when both inhibitors were combined. This study confirms the importance of fibrin polymerisation on the kinetics of thrombus formation and demonstrates the close association between the quality of the thrombus and the functional status of platelets. Normal platelet contractile forces are of major importance for the maximum amplitude of TEG which is related to the strength and elastic modulus of the thrombus.

Biomechanical Phenomena↗

Do xylem fibers affect vessel cavitation resistance?

Possible mechanical and hydraulic costs to increased cavitation resistance were examined among six co-occurring species of chaparral shrubs in southern California. We measured cavitation resistance (xylem pressure at 50% loss of hydraulic conductivity), seasonal low pressure potential (P(min)), xylem conductive efficiency (specific conductivity), mechanical strength of stems (modulus of elasticity and modulus of rupture), and xylem density. At the cellular level, we measured vessel and fiber wall thickness and lumen diameter, transverse fiber wall and total lumen area, and estimated vessel implosion resistance using (t/b)(h)(2), where t is the thickness of adjoining vessel walls and b is the vessel lumen diameter. Increased cavitation resistance was correlated with increased mechanical strength (r(2) = 0.74 and 0.76 for modulus of elasticity and modulus of rupture, respectively), xylem density (r(2) = 0.88), and P(min) (r(2) = 0.96). In contrast, cavitation resistance and P(min) were not correlated with decreased specific conductivity, suggesting no tradeoff between these traits. At the cellular level, increased cavitation resistance was correlated with increased (t/b)(h)(2) (r(2) = 0.95), increased transverse fiber wall area (r(2) = 0.89), and decreased fiber lumen area (r(2) = 0.76). To our knowledge, the correlation between cavitation resistance and fiber wall area has not been shown previously and suggests a mechanical role for fibers in cavitation resistance. Fiber efficacy in prevention of vessel implosion, defined as inward bending or collapse of vessels, is discussed.

Biomechanical Phenomena↗

Multifunctional Alloys Obtained via a Dislocation-Free Plastic Deformation Mechanism.

We describe a group of alloys that exhibit "super" properties, such as ultralow elastic modulus, ultrahigh strength, super elasticity, and super plasticity, at room temperature and that show Elinvar and Invar behavior. These "super" properties are attributable to a dislocation-free plastic deformation mechanism. In cold-worked alloys, this mechanism forms elastic strain fields of hierarchical structure that range in size from the nanometer scale to several tens of micrometers. The resultant elastic strain energy leads to a number of enhanced material properties.

Journal Article↗

A relationship between ultrasonic integrated backscatter and myocardial contractile function.

We have shown previously that the physiologic, mechanical cardiac cycle is associated with a parallel, cardiac cycle-dependent variation of integrated backscatter (IB). However, the mechanisms responsible are not known. The mathematical and physiological considerations explored in the present study suggest that the relationship between backscatter and myocardial contractile function reflects cyclic alterations in myofibrillar elastic parameters, with the juxtaposition of intracellular and extracellular elastic elements that have different intrinsic acoustic impedances providing an appropriately sized scattering interface at the cellular level. Cardiac cycle-dependent changes in the degree of local acoustic impedance mismatch therefore may elicit concomitant changes in backscatter. Because acoustic impedance is determined partly by elastic modulus, changes in local elastic moduli resulting from the non-Hookian behavior of myocardial elastic elements exposed to stretch may alter the extent of impedance mismatch. When cardiac cell mechanical behavior is represented by a three-component Maxwell-type model of muscle mechanics, the systolic decrease in IB that we have observed experimentally is predicted. Our prior observations of regional intramural differences in IB and the dependence of IB on global contractile function are accounted for as well. When the model is tested experimentally by assessing its ability to predict the regional and global behavior of backscatter in response to passive left ventricular distention, good concordance is observed.

Animals↗

The flexure modulus of elasticity of orthodontic wires.

The flexure moduli of elasticity of solid and multi-stranded orthodontic wires were determined. Results for the solid wires approximated their tensile values, but the differences were statistically significant for the stainless steel, chromium-cobalt-nickel, and nickel-titanium alloys. The flexure moduli of the multi-stranded wires ranged from 0.89 to 5.11 X 10(6) psi, and were dependent on the direction of activation.

Chromium Alloys↗