PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Electrocoagulation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Comparison of Bipolar Electrocoagulation and Nd:YAG Laser Coagulation for Symptomatic Reduction of Uterine Myomas

In 1991 and 1992, we presented a review of our experience using Nd:YAG laser fiber and bipolar needles to coagulate uterine myomas laparoscopically. We now present a comparison study of the Nd:YAG laser vs. bipolar coagulation needles for laparoscopic reduction of symptomatic uterine myomas. Since October 1990, we have performed over 300 cases of laparoscopic coagulation of symptomatic uterine myomas. The technique includes reduction of uterine and myomata size using depot leuprolide for a three to four month period of time. Hysteroscopic examination and endometrial sampling is performed during this preoperative period. The Nd:YAG laser fiber is a 600 micron bare fiber combined with a 50 watt Nd:YAG laser. The bi-polar needle is made in 30 and 45 mm lengths. The needles measure 5 cm in length and are inserted through a 5.5-mm trocar. Coagulation effect is measured by a standard ammeter. Myoma shrinkage is measured by pre- and post-operative vaginal ultrasound examination. Results reveal additional shrinkage 50-70% beyond the leuprolide effect. No myoma regrowth has been noted in this 3 year period. Minimal follow-up was 12 months. For patients with significant uterine bleeding, endometrial ablation is carried out at the same time.

Journal Article↗

Coagulation and electrocoagulation of wastes polluted with dyes.

Dyes are common pollutants in a large variety of industrial wastewaters, and the treatment of these wastes by coagulation has been extensively studied in the literature. This work is focused on the comparison of the efficiencies of the chemical and the electrochemical coagulation processes with hydrolyzing aluminum salts, and it tries to determine the similarities or differences that exist between the two coagulation processes. To do this, Eriochrome Black T solutions were used as a model of dye-polluted wastewater, and experiments of both coagulation technologies were planned to meet the same operation conditions. The pH, the aluminum concentration, the type of electrolyte, and the mode of dosing of aluminum were found to influence the process. Moreover, the speciation of aluminum was found to be the key parameter to explain the results, in terms of the mechanisms previously proposed in the literature for dissolved organic matter coagulation.

Aluminum Compounds↗

Electrocoagulation of textile wastewater bearing disperse dyes.

The paper describes a study on the removal of colour from textile wastewater bearing a mixture of three disperse dyes. The experiments were carried out in a reactor equipped with an Al sacrificial anode (100 cm2) and a stainless steel cathode of the same dimensions. Decolorisation occurred as a result of destabilisation of colloids due to an effect of an electric field generated between the electrodes (polarisation coagulation) and the reactions with coagulating compounds, formed in situ during anode oxidation (volumetric coagulation), followed by a subsequent flotation of agglomerates of the particles. During the study the following parameters were varied: initial pH of the solution, current density (between 100 and 300 A m-2) and an initial concentration of the dyes. The best results of elimination of colour, equal to 99%, were obtained during 5 minutes of treatment under the conditions of pH of 9 and the G factor equal to 41.

Aluminum↗

Techniques for the interruption of tubal patency for female sterilisation.

BACKGROUND: Female sterilization is the most popular contraceptive method worldwide. Several techniques are described in the literature, however only few of them are commonly used and properly evaluated. OBJECTIVES: To compare the different tubal occlusion techniques in terms of major and minor morbidity, failure rates (pregnancies), technical failures and difficulties and women's and surgeons' views. SEARCH STRATEGY: The Cochrane Controlled Trials Register has been searched. A search of the reference lists of identified trials was performed. An additional MEDLINE search was done using an Internet search service Pub Med. SELECTION CRITERIA: All randomized controlled trials comparing different techniques for tubal sterilization, regardless of the way of entry in the abdominal cavity or the method of anesthesia. DATA COLLECTION AND ANALYSIS: Trials under consideration were evaluated for methodological quality and appropriateness for inclusion. Nine relevant studies were included and the results were stratified in five groups: tubal ring versus clip, modified Pomeroy versus electrocoagulation, tubal ring versus electrocoagulation, modified Pomeroy versus Filshie clip and Hulka versus Filshie clip. Results are reported as odds ratio for dichotomous outcomes and weighted mean differences for continuous outcomes. MAIN RESULTS: Tubal ring versus clip: Minor morbidity was higher in the ring group (Peto OR 2.15; 95% CI 1.22, 3.78). Technical difficulties were found less frequent in the clip group ( Peto OR 3.87; 95% CI 1.90, 7.89). There was no difference in failure rates between the two groups (Peto OR 0.70; 95% CI 0.28, 1.76). Pomeroy versus electrocoagulation: Women undergoing modified Pomeroy technique had higher major morbidity than with electrocoagulation technique (Peto OR 2.87; 95% CI 1.13, 7.25). Postoperative pain was more frequent in the Pomeroy group (Peto OR 3.85; 95% CI 2.91, 5.10). Tubal ring versus electrocoagulation: Post operative pain was more frequently reported in the tubal ring group. No pregnancies were reported. Pomeroy versus Filshie clip: In the trial comparing the two interventions only one pregnancy was reported in the Pomeroy group after follow-up for 24 months. No differences were found when comparing Hulka versus Filshie clip in the only study that compared these two devices (Toplis 1988). REVIEWER'S CONCLUSIONS: Electrocoagulation was associated with less morbidity when compared with tubal ring and other methods. However the risk of burns to the small bowel might be a serious criticism of the approach. The small sample size and the relative short period of follow-up in these studies limited the power to show clinical or statistical differences for rare outcomes such as failure rates. Aspects such as training, costs and maintenance of the equipment may be important factors in deciding which method to choose.

Female↗

Evaluation of electrosurgical interference to low-power spread-spectrum local area net transceivers.

OBJECTIVE: To study whether an electrosurgery device interferes with the operation of a low-power spread-spectrum wireless network adapter. METHODS: Nonrandomized, unblinded trials with controls, conducted in the corridor of our institution's operating suite using two portable computers equipped with RoamAbout omnidirectional 250 mW spread-spectrum 928 MHz wireless network adapters. To simulate high power electrosurgery interference, a 100-watt continuous electrocoagulation arc was maintained five feet from the receiving adapter, while device reported signal to noise values were measured at 150 feet and 400 feet distance between the wireless-networked computers. At 150 feet range, and with continuous 100-watt electrocoagulation arc five feet from one computer, error-corrected local area net throughput was measured by sending and receiving a large file multiple times. RESULTS: The reported signal to noise (N = 50) decreased with electrocoagulation from 36.42+/-3.47 (control) to 31.85+/-3.64 (electrocoagulation) (p < 0.001) at 400 feet inter-adapter distance, and from 64.53+/-1.43 (control) to 60.12+/-3.77 (electrocoagulation) (p < 0.001) at 150 feet inter-adapter distance. There was no statistically significant change in network throughput (average 93 kbyte/second) at 150 feet inter-adapter distance, either transmitting or receiving during continuous 100 Watt electrocoagulation arc. CONCLUSIONS: The manufacturer indicates "acceptable" performance will be obtained with signal to noise values as low as 20. In view of this, while electrocoagulation affects this spread spectrum network adapter, the effects are small even at 400 feet. At a distance of 150 feet, no discernible effect on network communications was found, suggesting that if other obstructions are minimal, within a wide range on one floor of an operating suite, network communications may be maintained using the technology of this wireless spread spectrum network adapter. The impact of such adapters on cardiac pacemakers should be studied. Wireless spread spectrum network adapters are an attractive technology for mobile computer communications in the operating room.

Electricity↗

[Application of metal hemoclip for endoscopic polypectomy in children with thick-pedunculated intestinal polyps].

OBJECTIVE: With the development of endoscopic therapy in children, endoscopic electrocoagulation polypectomy had gradually replaced surgery and became an important method to resect gastrointestinal polyps in children. Simple electrocoagulation polypectomy could often bring some complications of gastrointestinal bleeding and perforation because of incomplete electrocoagulation or mechanical incision, especially in gastrointestinal thick-pedunculated polyps which always have thick nutrient blood vessel. Hemoclips can successfully interdict arteriovenous blood because it can clamp tissue firmly without causing necrosis around the target area. Based on its good mechanical hemostasis, hemoclips are not only widely used in treating bleeding like from ulcer, tumor and variceal ligation but also used in removal of thick-pedunculated gastrointestinal polyps in adults. This paper describes the application of endoscopic electrocoagulation with metal hemoclips to remove thick-pedunculated intestinal polpys in children for the first time, sums up the experience and evaluates its efficacy and safety. METHODS: Between October, 2001 and December, 2002, 5 cases with thick-pedunculated intestinal polpys were presented. The age of the patients ranged from 3 to 5 years. The clinical features were gastrointestinal bleeding or abdominal pain. The longest course of disease was 2 years. Enough preparations for alimentary tract were necessary for polypectomy. The procedures were performed under general anesthesia in order to avoid the risk of bleeding aspiration. Endoscopy was performed in the standard fashion. The apparatus included electronic colonic endoscope (XQ 200, Fuji Corp, Tokyo, Japan), snare (XQ200, Fuji Corp, Tokyo, Japan), impeller of the clip (HX-5QR-1) and hemoclip (MD850) which could be passed through the biopsy channel of endoscope. The clip was completely covered with a hood avoiding any injury to the mucous membrane. The pedicel with diameter of more than 1.0 cm underwent endoscopic electrocoagulation polypectomy with hemoclips. The clip contacted polyps in upright direction. One or more hemoclips were selected to clamp the proximal basement of the pedicel in terms of the pedicel diameter. Turning of the red colour of polyps to purple suggested that hemoclip interdicted arteriovenous blood effectively. The clip was then shut off and electrocoagulation polypectomy was followed. Six polyps were observed and removed. RESULTS: Six polyps including 2 transverse colon polyps and 4 descending colon polyps were resected. Pathological results showed that 3 were juvenile polyps and the other 3 adenomatous polyps. All the polyps were completely resected. The diameter of pedicel were 1.2 - 2.2 cm. The head and pedicel of the biggest polyp was about 5 cm x 5 cm and 2.2 cm, respectively, and five clips were used in order to remove it. No complications of bleeding and perforation were observed in these children. All hemoclips were expelled from intestines within one week. The symptoms of these patients disappeared. CONCLUSION: Mechanical hemostasis with hemoclips successfully interdicted arteriovenous blood of thick-pedunculated polyps. Hemoclips can successfully prevent the complications of bleeding and perforation. The clipping brings about a new method in endoscopic therapy. Endoscopic electrocoagulation polypectomy with hemoclips is a simple, safe and effective method to treat thick-pedunculated gastrointestinal polyps in children and it is a valuable tool in polypectomy for children.

Child↗

The treatment of common warts with infrared coagulation.

Treatment of warts can involve medical and surgical methods. Infrared coagulation is a surgical method very rarely used in the treatment of warts. We planned an open-labeled prospective study to research the effect of infrared coagulation in the treatment of common warts, comparing it with electrocoagulation, and discussing its applicability as an alternative therapy regimen. Eighteen patients with common warts were included in this study. There were 49 warts of various sizes (1 mm to 1 cm) in these 18 patients. Twenty-seven warts were treated with infrared coagulation, and 22 warts were treated with electrocoagulation. Sixteen patients were treated with both infrared coagulation and electrocoagulation; two patients were treated with only infrared coagulation. The patients were followed-up for six months after treatment. Changes in sizes of warts, healing times, and cure rates were compared by Mann-Whitney U test. The mean healing time was 35.5 +/- 5.7 days with infrared coagulation and 32.9 +/- 4.0 days with electrocoagulation. There was not any significant difference between healing times (p > 0.05). Bacterial infection was seen on seven (31.8%) warts treated with electrocoagulation, but no side effects were seen with infrared coagulation. There was a significant difference between side effect rates in two groups (p < 0.01). Nine (33.3%) of the warts treated with infrared coagulation and seven (31.8%) of the warts treated with electrocoagulation recurred in the six-month follow-up period. The overall cure rates at the end of the follow-up period were 66.7% and 68.2% respectively. There was not any significant difference between the cure rates in the two groups (P > 0.05). We conclude that infrared coagulation is a safe and cheap method and should be kept in mind as an alternative modality for the treatment of common warts.

Adolescent↗