PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “HEART VALVES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Sarcoma associated with silver coated mechanical heart valve prosthesis.

Sarcomas can develop in association with foreign material (eg, from Dacron vascular prostheses). We report on a left atrial rhabdomyosarcoma that developed within 1 year of mitral valve replacement by a Silzone-coated St. Jude Medical mechanical heart valve. Tumor resection and redo valve replacement were done. Six months later the patient was alive, but an echocardiogram showed tumor recurrence. Although this is a single case, an association between heart valve prostheses and malignant tumors should be considered.

Coated Materials, Biocompatible↗

IL-8 and tumor necrosis factor alpha in heart valves from patients with infective endocarditis.

The embedding of bacteria in the vegetation of infective endocarditis impedes the penetration of phagocytic cells. IL-8 has a stimulating effect on the immune system, particularly with respect to chemotaxis and activation of granulocytes. Tumor necrosis factor alpha (TNF-alpha) is 1 of the major proinflammatory cytokines. IL-8 and TNF-alpha were visualized by means of immunohistochemistry in paraffin-embedded heart valve biopsies from 6 patients with infective endocarditis who required cardiac surgery during the active phase of the infection. In 5/6 patients there were signs of inflammation, and in these patients IL-8- and TNF-alpha-containing cells were visualized in the heart valve stromas or vegetations. The largest numbers of IL-8-containing cells, and the greatest amount of inflammation, were seen in patients with short preoperative treatment courses. No such relationships were seen with respect to TNF-alpha-containing cells. These observations may suggest that the occurrence of IL-8-containing cells in infected heart valves could be used as a marker of disease activity.

Adult↗

Mechanical heart valves: are two leaflets better than one?

OBJECTIVE: We sought to compare the long-term clinical outcomes of patients who underwent isolated aortic valve replacement with single-disc and bileaflet mechanical heart valves. METHODS: From May 1975 through October 2001, 590 single-disc valves (7 models) were used for isolated valve replacement, and from November 1980 through July 2002, 1283 bileaflet valves (10 models) were used for isolated valve replacement. Detailed follow-up was performed to a maximum of 27.4 and 21.9 years with a total of 6872 and 5811 patient-years for single-disc valves and bileaflet valves, respectively. Survival and valve-related events were analyzed. RESULTS: Single-disc valves were mainly implanted from 1975 through 1995, whereas bileaflet valves were mainly implanted from 1987 through 2002; thus the years of concurrent use were 1987 through 1995. The bileaflet valve had a significantly lower explantation rate, whereas the single-disc valve had a significantly lower thromboembolism rate. No significant differences were detected in early mortality, long-term survival, and other valve-related complications. When limiting the comparison to the concurrent period of 1987 through 1995, no significant difference was detected in survival or in any valve-related complication. CONCLUSION: Single-disc and bileaflet valves provide similar clinical performance. The predominant use of bileaflet valves is not based on clinical outcomes.

Adult↗

Echocardiographic identification and analysis of function of the St. Jude medical heart valve prosthesis.

The St. Jude medical (SJM) heart valve prosthesis presents a new bi-leaflet design which in preclinical evaluation exhibited favourable haemodynamic characteristics. Therefore clinical trials started in February 1978. The entire valve is made of pyrolytic carbon which has a poor X-ray visibility and therefore an alternative for the noninvasive routine control of valvular function and postoperative follow-up had to be found. Experimental studies in a left heart simulator provided adequate echovisualisation of both leaflets, however, depending on the direction of their motion in relation to the echobeam. Identification of both leaflets and an analysis of their motion was possible with a transducer at right angles to the leaflet axis. The experimental data were confirmed by clinical observations after implantation of the SJM prosthesis in patients. Based on the information obtained, we are providing recommendations for the implantation of the SJM prosthesis in order to achieve optimal echocardiographic visualisation of the valve and its moving parts in the postoperative follow-up.

Echocardiography↗

Recommendations for reporting morbid events after heart valve surgery.

Major reasons for the considerable heterogeneity among published results of heart valve surgery are inconsistency in follow up techniques, reporting systems and classification of adverse events. The present recommendations are intended to harmonize the presentation of clinical material in order to improve comparison of data from different sources for the analysis of pooled data. The quality of an observational study is largely, if not entirely, due to the follow up technique, which may be graded according to six categories: Self-reporting of adverse events/well-being by the patients may be classified 'excellent'; if the information is gathered and re-checked at short-term intervals. Data obtained from in-hospital or outpatient examinations by qualified examiners at least twice a year or other personal contact through qualified examiners may be regarded as 'sufficient', if the results are re-checked by contacting the treating home physician. All other follow up techniques may be regarded as inappropriate. Consequences of complications are entirely dependent on severity and possible sequelae. It is therefore recommended to grade any reported complication according to its severity by utilizing a score system. Embolisms are best categorized by utilizing the performance status scale. Bleeding events may be categorized according to severity as fatal, major (requiring hospital transmission with transfusion, surgery or with permanently increased disability) or minor (not requiring hospital admission, surgery or transfusion). In some cases it will remain unclear whether an event was primarily embolic or hemorrhagic. These complications should be summarized as 'not categorized'. The reporting of morbid events due to thrombosis, embolism and bleeding should go along with information regarding the quality of antithrombotic management.

Anticoagulants↗

[Second set method for determining the immunogenicity of heart valves].

The "second set" method was used on inbred rats to study immunogenicity of the heart valves treated with a proteolytic enzyme and glutaric aldehyde and to compare it with immunogenicity of the valves treated with glutaric aldehyde alone according to Hancock's method. The valves treated by the enzyme and 0.2-0.5% glutaric aldehyde did not lead to the body sensitization in contrast to the valves exposed to 0.5% glutaric aldehyde alone. During transplantation of the latter ones, there were signs of the immunologic response on the part of the recipients and calcification of valvular tissue 70 days after subcutaneous implantation. It is assumed that pretreatment with the enzyme makes it possible to appreciably reduce immunogenicity of the heart valves.

Amylases↗

Scanning electron microscopy methodology for study of the pathophysiology of calcification in bioprosthetic heart valves.

Scanning electron microscope (SEM) morphologic analysis combined with energy dispersive characteristic X-ray (EDX) microprobe analysis provides insight into the mechanisms associated with disease-related crystal formation in biological materials. SEM and EDX were employed in analyzing specimens which were embedded in standard fashion in glycolmethacrylate. The specimen surfaces under electron microscope investigation resulted from microtomy used in the preparation of reference light microscope histological sections; thus histology served as a direct reference for the SEM and EDX analyses. The particular application of these methods was in the study of bioprosthetic heart valve calcification, largely responsible for clinical failure of these heart valve substitutes. To simulate the clinically observed mineralization processes, glutaraldehyde-pretreated porcine heart valve leaflets were implanted subcutaneously in rats and subsequently removed at various time intervals from 1 to 56 days. Also, to address the hypothesis that the calcification process generates crystalline materials analogous to those in bone, EDX data obtained from pure hydroxyapatite were compared with the embedded tissue results. Further, EDX results were compared with data obtained by chemical analysis of the bulk specimens to assess the validity of the electron microscope technique.

Animals↗

[ECG changes in the late postoperative course of patients following alloplastic heart valve replacement].

Based upon a total of 50 patients with alloplastic heart valve substitute an attempt was made to verify postoperative retrogression of the signs of hypertrophy in the ECG and to correlate them with the clinical findings. In accordance with the pertaining literature, the essential criterion for assessing left hypertrophy is the Sokolow index. In corrected aortic lesions there is a close relation between retrogression of electrocardiographic signs of hypertrophy and the clinical degree of severity. All patients with a retrogressive tendency of the signs of hypertrophy showed definite improvement of clinical findings. Patients in whom the ECG deteriorated did not have good clinical findings either. This clear relationship is not demonstrable in mitral lesions, since mitral stenosis and mitral insufficiency influence the left ventricle, the left atrium and the pulmonary circulation in various ways. A discussion of the assessment of the individual ECG symptoms and their causes is added.

Adolescent↗

[Reoperations after insertion of heart valve prosthesis].

The authors analysed 167 repeated operations after heart valve prosthetics, which were conducted from 1978 to 1988. The operations were undertaken for the second time mainly in a severe contingent of patients. The reasons for the repeated operations were specific complications according to which 2 groups of patients were set apart: with dysfunction of the prosthesis of noninfectious origin and with prosthetic endocarditis. Study showed that repeated operative intervention undertaken in time reduces considerably its risk and produces a stable positive effect in most cases.

Adolescent↗

In vivo degradation of silicone rubber poppets in prosthetic heart valves.

Dynamic shear modulus G' was measured throughout the volume of three nonvariant silicone rubber poppets which were recovered from aortic prosthetic heart valves that had been implanted for 4 days, 52 days, and 8 years. Similar measurements were obtained for two unused silicone rubber poppets. Although the recovered poppets exhibited no obvious physical evidence of damage, the silicone rubber had undergone in vivo degradation throughout the poppet volume as indicated by decreases in modulus. The measurements also indicate that the poppet surface degrades at a rate faster than the core. Further, comparison with data reported in the literature suggests that the surfaces of variant poppets degrade at a rate faster than the surfaces of nonvariant poppets.

Aortic Valve↗

Prosthetic heart valve malfunction: plain film findings.

Clinical signs of heart valve malfunction are often not specific so that recognition frequently depends on nonclinical methods. The chest radiographs of 34 patients with 41 prosthetic valve malfunctions (PVM) were compared before and after valve failure. The most frequent sign of PVM is postcapillary hypertension (90%). A marked increase in heart size occurs with regurgitation but not with obstruction. A change in attitude of a valve of more than 6 degrees. in the aortic and 12 degrees in the mitral position is virtually diagnostic of dehiscence. This was seen in 52% of patients with paravalvular regurgitation and in 29% of all patients with PVM. When dehiscence is suspected on clinical or radiologic grounds the valve should be examined fluoroscopically. Changes in the azygos vein and the vascular pedicle of the heart and the development of pleural effusions are less useful signs of PVM. Although the chest radiograph is often not diagnostic of PVM, it may point to the need for definitive investigation.

Adult↗

[Histological biomorphosis of human heart valve. II. Morphometric studies].

Previous polarization-microscopical measurements combined with silver-staining methods at histological sections of the bicuspid valve and the tricuspid valve in the region of fibrosa showed (similar to that of the corresponding tendinous cords) for middle-aged persons a distinct difference in the collagen composition in comparison between high pressure vs. low pressure system. The aim of the current study was the morphometric investigation of the collagen composition, of the relative content of total collagen (measured as relative number of total collagen fibers per measuring area), and of the cell-collagen relation in dependence of age and possibly on sex in the high and low pressure system, respectively. Tissue samples of atrioventricular valves of 67 probands of both sexes were available. The probands were healthy with regard to heart and circulation and distributed in 3 age groups (1st to 2nd decade, 3rd to 5th decade, and 6th to 9th decade). After corresponding preliminary treatment, the histological sections of tissue samples were evaluated by a suitable combination of polarization-microscopical, immuno-histochemical, and morphometrical methodology. The thickness of the heart valves was measured by microscopic image analysis. A rise of the number of fibers per measuring area (ma) for both sexes and both valves was observed with increasing age. The slopes of the linear regression curves and the mean values of the numbers of collagenous fibers/ma (for each age group) were different between both sexes. They depend upon the valve considered. Analogous to these results, the differentiated statements were possible to the number of fibers/ma and to the percentages of the fiber species by the distinction between the collagen types I and III in the fibrosa of the heart valves. Whereas the relative numbers of fibers/ma rose with increasing age, the number of cell (fibroblasts, fibrocytes) nuclei for both valves and sexes slightly decreased. For the latter, there was no difference between high and low pressure system in contrast to the collagenous fibers. The opposite age-dependent behavior of the collagenous fibers and of their producing cells during the biomorphosis of the heart valves could be explained with the collagen turn-over.

Adolescent↗

Assessment of hemodynamics properties of a new-type artificial heart valve prosthesis using catheterization and echocardiography.

OBJECTIVE: The objectives of this study were to assess the hemodynamic properties of the newly developed artificial heart valve prosthesis experimentally in laboratory simulation, in an animal model, and clinically in a human model and to compare the results measured by catheterization and echocardiography. METHODS: (1) Laboratory simulation. The prosthesis was tested using a pulsatile flow simulator in the aortic position. Hydrodynamics parameters were automatically analyzed through a custom-designed data processing program. (2) Animal experiment. Six sheep subjected to mitral replacement with 21-mm-valve prosthesis were measured by open cardiac catheterization intraoperatively. Doppler echocardiography and open cardiac catheterization under dobutamine stress were performed in two sheep subjected to implantation 2.5 years ago. (3) Clinical patient observation. Observations were carried out on 14 patients with aortas replacement and 10 patients with bicuspid replacement using both doppler echocardiography and open cardiac catheterization. RESULTS: (1) Laboratory simulation. The results showed that the value of the transvalvular gradient (DeltaP) decreased with the increase of heart rate, and the values were not greater that 10 mm Hg at any given tissue annulus diameter. (2) Animal experiment. The mean DeltaP value of the six sheep was 5.2 +/- 1.7 mm Hg intraoperatively, while the corresponding DeltaP value of the two sheep 2.5 years after implantation was 6.1 +/- 0.3 mm Hg measured by open cardiac catheterization. (3) Clinical patient observation. The mean DeltaP values in the aortic position measured by catheterization and echocardiography were 6.26 approximately 4.10 and 9.42 approximately 7.48 mm Hg, respectively. The gradients in the mitral position were 2.10 approximately 1.9 and 5.28 approximately 4.10 mm Hg, respectively. CONCLUSIONS: The results demonstrate that the new-type bileaflet heart valve prosthesis only generates a relatively low transvalvar gradient and thus has good hemodynamic properties.

Adult↗

Correlation between heart valve interstitial cell stiffness and transvalvular pressure: implications for collagen biosynthesis.

It has been speculated that heart valve interstitial cells (VICs) maintain valvular tissue homeostasis through regulated extracellular matrix (primarily collagen) biosynthesis. VICs appear to be phenotypically plastic, inasmuch as they transdifferentiate into myofibroblasts during valve development, disease, and remodeling. Under normal physiological conditions, transvalvular pressures (TVPs) on the right and left side of the heart are vastly different. Hence, we hypothesize that higher left-side TVPs impose larger local tissue stress on VICs, which increases their stiffness through cytoskeletal composition, and that this relation affects collagen biosynthesis. To evaluate this hypothesis, isolated ovine VICs from the four heart valves were subjected to micropipette aspiration to assess cellular stiffness, and cytoskeletal composition and collagen biosynthesis were quantified by using the surrogates smooth muscle alpha-actin (SMA) and heat shock protein 47 (HSP47), respectively. VICs from the aortic and mitral valves were significantly stiffer (P < 0.001) than those from the pulmonary and tricuspid valves. Left-side isolated VICs contained significantly more (P < 0.001) SMA and HSP47 than right-side VICs. Mean VIC stiffness correlated well (r = 0.973) with TVP; SMA and HSP47 also correlated well (r = 0.996) with one another. Assays were repeated for VICs in situ, and, as with in vitro results, left-side VIC protein levels were significantly greater (P < 0.05). These findings suggest that VICs respond to local tissue stress by altering cellular stiffness (through SMA content) and collagen biosynthesis. This functional VIC stress-dependent biosynthetic relation may be crucial in maintaining valvular tissue homeostasis and also prove useful in understanding valvular pathologies.

Animals↗

Detection of cariogenic Streptococcus mutans in extirpated heart valve and atheromatous plaque specimens.

The involvement of oral bacteria in the pathogenesis of cardiovascular diseases has been the focus of attention in many studies, and several periodontal pathogens have been detected in diseased cardiovascular lesions, suggesting relationships between oral microorganisms and cardiovascular diseases. However, no information is available regarding the involvement of cariogenic pathogens such as Streptococcus mutans. The presence of oral streptococcal species and periodontitis-related bacteria in 35 heart valve and 27 atheromatous plaque clinical specimens, as well as 32 dental plaque specimens from the same subjects, was analyzed using a PCR method. Furthermore, broad-range PCR with DNA sequencing analysis was employed to identify the bacterial species in those samples. Streptococcus mutans was frequently detected in the heart valve (69%) and atheromatous plaque (74%) specimens, while other bacterial species, including those related to periodontitis, were detected with much lower frequencies. The bacterial composition in cardiovascular tissues was found to be markedly distinct from that in dental plaque, with only a limited number of species, including S. mutans, in the cardiovascular regions shown to have possibly originated from the oral cavity. Semiquantitative assay results revealed that S. mutans was detected in significant quantities in the heart valve (40%) and atheromatous plaque (48%) specimens, whereas the quantities of all other tested bacterial species, including several related to periodontitis, were negligible in the cardiovascular samples. These results indicate that S. mutans is a possible causative agent of cardiovascular disease.

Aged↗

[Three-dimensional visualization of stationary flow behind artificial heart valves].

The visualization and quantitative analysis of flow offers a possibility for the hydrodynamic characterization of artificial heart valves. Different types of valves can be compared if velocity profile and the turbulent shear stress caused by the prosthesis are known. The tracer technique was selected, since it permits visualization also of turbulent flow through the valve. With the aid of a simple optical device the three-dimensional flow pattern behind the valve is determinable. The main features of the method are: The regions of interest can easily be identified. Velocity profiles can be determined and shear stress and turbulence intensities estimated. The experimental setup is simple, calibration is not necessary, and it can be used for turbulent flows. The method can be used only with transparent fluids and vessels; measurements in blood are not possible. Because of the large number of measuring points required the method is very time-consuming. The use of an automatic picture analyzing system would make it possible to increase the number of pictures processed, and thus increase resolution. The velocity profile of a three-finger-valve, the TAD 29, was established at a distance of 20 mm from the ring, and compared with known profiles from the literature. The valve has an opening angle of 70 degrees. All typical regions for the flow of an artificial heart valve, such as jet, stagnation gone, backflow and turbulence were demonstrated.

Blood Flow Velocity↗

A comparative computational study of blood flow through prosthetic heart valves using the finite element method.

The steady flow of blood through three common types of prosthetic heart valves was simulated numerically using the finite element method. The velocity, pressure and stress fields were obtained for the disk-type, tilting-disk and ball-type prosthetic heart valves in aortic position, for increasing Reynolds numbers up to 900, 1500 and 2000 respectively. Computer graphics of calculated velocities are presented, showing in detail the accelerated flow, recirculation and stagnation areas developed in the prosthesis. Maximum wall shear stresses were found at 0.5, 1.4, and 1.2 diameters from the sewing ring downstream for the disk, tilting-disk and ball valves being the values of 55, 18 and 33 dyn cm-2 respectively. In the vicinity of the occluder, maximum shear stresses of 38, 30 and 47 dyn cm-2 respectively were computed. The flow characteristics and performance for each valve are compared, the results are presented in terms of energy loss and maximum shear stress. The velocity and stress fields are compared with in vitro evaluations found in the literature.

Aortic Valve↗