Image data compression using a new floating-point digital signal processor.

A new dual-ported, floating-point, digital signal processor has been evaluated for compressing 512 and 1,024 digital radiographic images using a full-frame, two-dimensional, discrete cosine transform (2D-DCT). The floating point digital signal processor operates at 49.5 million floating point instructions per second (MFLOPS). The level of compression can be changed by varying four parameters in the lossy compression algorithm. Throughput times were measured for both 2D-DCT compression and decompression. For a 1,024 x 1,024 x 10-bit image with a compression ratio of 316:1, the throughput was 75.73 seconds (compression plus decompression throughput). For a digital fluorography 1,024 x 1,024 x 8-bit image and a compression ratio of 26:1, the total throughput time was 63.23 seconds. For a computed tomography image of 512 x 512 x 12 bits and a compression ratio of 10:1 the throughput time was 19.65 seconds.

Algorithms↗

Testing statistical significance scores of sequence comparison methods with structure similarity.

BACKGROUND: In the past years the Smith-Waterman sequence comparison algorithm has gained popularity due to improved implementations and rapidly increasing computing power. However, the quality and sensitivity of a database search is not only determined by the algorithm but also by the statistical significance testing for an alignment. The e-value is the most commonly used statistical validation method for sequence database searching. The CluSTr database and the Protein World database have been created using an alternative statistical significance test: a Z-score based on Monte-Carlo statistics. Several papers have described the superiority of the Z-score as compared to the e-value, using simulated data. We were interested if this could be validated when applied to existing, evolutionary related protein sequences. RESULTS: All experiments are performed on the ASTRAL SCOP database. The Smith-Waterman sequence comparison algorithm with both e-value and Z-score statistics is evaluated, using ROC, CVE and AP measures. The BLAST and FASTA algorithms are used as reference. We find that two out of three Smith-Waterman implementations with e-value are better at predicting structural similarities between proteins than the Smith-Waterman implementation with Z-score. SSEARCH especially has very high scores. CONCLUSION: The compute intensive Z-score does not have a clear advantage over the e-value. The Smith-Waterman implementations give generally better results than their heuristic counterparts. We recommend using the SSEARCH algorithm combined with e-values for pairwise sequence comparisons.

Base Sequence↗

Learning chaotic attractors by neural networks.

An algorithm is introduced that trains a neural network to identify chaotic dynamics from a single measured time series. During training, the algorithm learns to short-term predict the time series. At the same time a criterion, developed by Diks, van Zwet, Takens, and de Goede (1996) is monitored that tests the hypothesis that the reconstructed attractors of model-generated and measured data are the same. Training is stopped when the prediction error is low and the model passes this test. Two other features of the algorithm are (1) the way the state of the system, consisting of delays from the time series, has its dimension reduced by weighted principal component analysis data reduction, and (2) the user-adjustable prediction horizon obtained by "error propagation"-partially propagating prediction errors to the next time step. The algorithm is first applied to data from an experimental-driven chaotic pendulum, of which two of the three state variables are known. This is a comprehensive example that shows how well the Diks test can distinguish between slightly different attractors. Second, the algorithm is applied to the same problem, but now one of the two known state variables is ignored. Finally, we present a model for the laser data from the Santa Fe time-series competition (set A). It is the first model for these data that is not only useful for short-term predictions but also generates time series with similar chaotic characteristics as the measured data.

Algorithms↗

Comparison and evaluation of a disease activity index for use in patients with rheumatoid arthritis.

An algorithm (Stoke index) has been designed to give a global measure of disease activity in rheumatoid arthritis. This algorithm has been created as an easy to use flow diagram based on two objective laboratory measures (C-reactive protein and erythrocyte sedimentation rate), one subjective and two semi-objective clinical measures (morning stiffness, synovitis score and Ritchie articular index). Results of six clinical markers and seven laboratory markers of disease activity on a cohort of 371 rheumatoid patients have been used to evaluate the algorithm and compare it with a previously described index of disease activity (Mallya-Mace index). Principal component analysis validates its ability to measure disease activity. Sensitivity is described by the distribution of patients between the two index scores. Change in index score by patients over a 6-month period indicates reversibility. The Stoke index demonstrates greater sensitivity and reversibility than the Mallya-Mace index. These findings indicate that the algorithm described provides a useful index of global disease activity for use in the assessment of rheumatoid arthritis.

Adult↗

Convergent Island Statistics: a fast method for determining local alignment score significance.

MOTIVATION: Background distribution statistics for profile-based sequence alignment algorithms cannot be calculated analytically, and hence such algorithms must resort to measuring the significance of an alignment score by assessing its location among a distribution of background alignment scores. The Gumbel parameters that describe this background distribution are usually pre-computed for a limited number of scoring systems, gap schemes, and sequence lengths and compositions. The use of such look-ups is known to introduce errors, which compromise the significance assessment of a remote homology relationship. One solution is to estimate the background distribution for each pair of interest by generating a large number of sequence shuffles and use the distribution of their scores to approximate the parameters of the underlying extreme value distribution. This is computationally very expensive, as a large number of shuffles are needed to precisely estimate the score statistics. RESULTS: Convergent Island Statistics (CIS) is a computationally efficient solution to the problem of calculating the Gumbel distribution parameters for an arbitrary pair of sequences and an arbitrary set of gap and scoring schemes. The basic idea behind our method is to recognize the lack of similarity for any pair of sequences early in the shuffling process and thus save on the search time. The method is particularly useful in the context of profile-profile alignment algorithms where the normalization of alignment scores has traditionally been a challenging task. CONTACT: aleksandar@eidogen.com SUPPLEMENTARY INFORMATION: http://www.eidogen-sertanty.com/Documents/convergent_island_stats_sup.pdf.

Algorithms↗

Comparison among tomographic radionuclide ventriculography algorithms for computing left and right ventricular normal limits.

BACKGROUND: Various algorithms have been developed to compute right ventricular (RV) and left ventricular (LV) end-diastolic volumes, end-systolic volumes, and ejection fractions (EF) from tomographic radionuclide ventriculography (TRV). The aims of this investigation were to establish sex-specific normal limits, to determine whether different algorithms produce the same normal values, and to compare TRV normal limits vs for magnetic resonance imaging values in the literature. METHODS: Fifty-one healthy volunteers (29 men, 22 women) were studied prospectively. All subjects had normal electrocardiograms and echocardiographic examinations, and underwent both planar radionuclide ventriculography and TRV. Four algorithms were used to process TRV data. RESULTS: Normal limits for most functional parameters differed significantly from one algorithm to another. Volumes were greater in men, but no statistically significant differences were found between men and women for LV EF or RV EF values for any method. Normal LV and RV EF and volumes were largely consistent with the literature for cardiac magnetic resonance imaging. CONCLUSIONS: Ventricular measurements differ significantly among TRV algorithms. Therefore, it is important to apply sex-specific normal limits that are specific to a given TRV algorithm in interpreting LV and RV EF and volume measurements for each patient.

Adult↗

Three-dimensional imaging characteristics of the HEAD PENN-PET scanner.

UNLABELLED: A volume-imaging PET scanner, without interplane septa, for brain imaging has been designed and built to achieve high performance, specifically in spatial resolution and sensitivity. The scanner is unique in its use of a single annular crystal of Nal(Tl), which allows a field of view (FOV) of 25.6 cm in both the transverse and axial directions. Data are reconstructed into an image matrix of 128(3) with (2 mm)3 voxels, using three-dimensional image reconstruction algorithms. METHODS: Point-source measurements are performed to determine spatial resolution over the scanner FOV, and cylindrical phantom distributions are used to determine the sensitivity, scatter fraction and counting rate performance of the system. A three-dimensional brain phantom and 18F-FDG patient studies are used to evaluate image quality with three-dimensional reconstruction algorithms. RESULTS: The system spatial resolution is measured to be 3.5 mm in both the transverse and axial directions, in the center of the FOV. The true sensitivity, using the standard NEMA phantom (6 liter), is 660 kcps/microCi/ml, after subtracting a scatter fraction of 34%. Due to deadtime effects, we measure a peak true counting rate, after scatter and randoms subtraction, of 100 kcps at 0.7 mCi for a smaller brain-sized (1.1 liter) phantom, and 70 kcps for a head-sized (2.5 liter) phantom at the same activity. A typical 18F-FDG clinical brain study requires only 2 mCi to achieve high statistics (100 million true events) with a scan time of 30 min. CONCLUSION: The HEAD PENN-PET scanner is based on a cost-effective design using Nal(Tl) and has been shown to achieve high performance for brain studies and pediatric whole-body studies. As a full-time three-dimensional imaging scanner with a very large axial acceptance angle, high sensitivity is achieved. The system becomes counting-rate limited as the activity is increased, but we achieve high image quality with a small injected dose. This is a significant advantage for clinical imaging, particularly for pediatric patients.

Brain↗

Interfragmentary surface area as an index of comminution energy: proof of concept in a bone fracture surrogate.

Fracture mechanics theory postulates a monotonic relationship between energy absorption and fracture surface generation. We hypothesized that this relationship was demonstrable to the point that, on a continuous scale, comminuted fractures created with disparate levels of energy delivery could be discriminated. Using a bone fracture surrogate in conjunction with digital image analysis of CT fracture data, we measured the surface area freed by controlled, discrete fracture simulations. Prior to these simulations, the reproducibility of the digital image analysis algorithm was validated with repeated measurements by two different operators. The parametric fracture series results showed a statistically significant difference in measured de novo surface area between four specimen groups, over a range of input energies from 1.4 x 10(10)-9.1 x 10(10)J/m(3) (or 12.5-80.2J/specimen). The results of this study provide confirmation that comminution severity can indeed be measured on a continuous scale, based on energy absorption (another clinically meaningful index).

Algorithms↗

Azimilide decreases defibrillation voltage requirements and increases spatial organization during ventricular fibrillation.

INTRODUCTION: Drugs with class III antiarrhythmic properties generally decrease defibrillation threshold (DFT). However, the concentration effect relation for this effect and drug effects on ventricular fibrillation (VF) itself are not well understood. The objectives of this study were to determine the effect of azimilide (NE-10064), a new class III agent, on DFT, and on spatial organization during VF. METHODS: Defibrillation patch electrodes were sutured to the right and left ventricular epicardium in 12 open-chest anesthetized dogs. The delayed up-down algorithm was used to measure DFT and to estimate the shock strength (voltage) with a 50% probability of successful defibrillation (V50). The magnitude squared coherence (MSC), which measures the spatial relation in the frequency domain, was measured during VF between two unipolar epicardial electrodes 3 mm apart. The V50, MSC, electrophysiologic parameters, and plasma concentrations were determined before and after four cumulative i.v. doses of azimilide (2, 7, 17, and 30 mg/kg). RESULTS: Azimilide elicited a dose dependent reduction of V50 and increase in MSC. Compared with baseline, azimilide lowered mean V50 by 2 +/- 9%, 10 +/- 18%, 11 +/- 14% and 19 +/- 5%, and increased MSC by 17 +/- 20%, 32 +/- 31%, 20 +/- 44% and 27 +/- 20% (p < 0.05 for dose effect) at 2, 7, 17 and 30 mg/kg, respectively. Mean increases in monophasic action potential duration at 90% repolarization (3-11%), ventricular effective refractory period (6-13%) at 400 msec paced cycle length, and VF cycle length (5-37%) (p < 0.01 for dose effect) were observed with the 4 increasing doses of azimilide, respectively. CONCLUSION: Azimilide significantly decreases DFT and increases coherence in VF in a dose dependent manner.

Algorithms↗

Diffuse reflectance spectrophotometry with visible light: comparison of four different methods in a tissue phantom.

The purpose of the study was to compare algorithms of four methods (plus two modifications) for spectrophotometric haemoglobin saturation measurements. Comparison was made in tissue phantoms basically consisting of a phosphate buffer, Intralipid and blood, allowing samples to be taken for reference measurements. Three experimental series were made. In experiment A (eight phantoms) we used the Knoefel method and measured specific extinction coefficients with a reflection spectrophotometer. In experiment B (six phantoms) the fully oxygenated phantoms were gradually deoxygenated with baker's yeast, and simultaneous measurements were made with our spectrophotometer and with a reference oxymeter (ABL-605) in 3 min intervals. For each spectrophotometric measurement haemoglobin saturation was calculated with all algorithms and modifications, and compared with reference. In experiment C (11 phantoms) we evaluated the ability of a modification of the Knoefel method to measure haemoglobin concentration in absolute quantities using extinction coefficients from experiment A.Results. Experiment A: with the Knoefel method extinction coefficients (+/-SD) for oxyhaemoglobin at 553.04 and 573.75 nm were 1.117 (+/-0.0396) ODmM(-1) and 1.680 (+/- 0.0815) ODmM(-1), respectively, and for deoxyhaemoglobin 1.205 (+/- 0.0514) ODmM(-1) and 0.953 (+/-0.0487) ODmM(-1), respectively. Experiment B: high correlation with the reference was found in all methods (r = 0.94-0.97). However, agreement varied from evidently wrong in method 3 and the original method 4 (e.g. saturation above 160%) to high agreement in method 2 as well as the modifications of methods 1 and 4, where oxygen dissociation curves were close to the reference method. Experiment C: with the modified Knoefel method the mean haemoglobin concentration difference from reference was 8.3% and the correlation was high (r = 0.91). We conclude that method 2 and the modifications of 1 and 4 were superior to the others, but depended on known values in the same or similar phantoms. The original method 1 was independent of results from the tissue phantoms, but agreement was slightly poorer. Method 3 and the original method 4 could not be recommended. The ability of the modified method 1 to measure haemoglobin concentration is promising, but needs further development.

Algorithms↗

Tendon reflexes for predicting movement recovery after acute spinal cord injury in humans.

OBJECTIVE: Use the tendon reflex to examine spinal cord excitability after acute spinal cord injury (SCI), relating excitability findings to prognosis. METHODS: We conducted repeated measures of reflex responses to mechanical taps at the patellar and Achilles tendons of the lower limbs, and the wrist flexor tendons of the upper limbs in persons with acute SCI, beginning as early as the day of injury. The single largest EMG response (peak-to-peak) for each site was recorded. Subjects were compared based on level of injury and final neurologic status of lower limb motor function (i.e. absence of any voluntary recruitment in a lower limb muscle: motor-complete; voluntary recruitment in 1 or more lower-limb muscles: motor-incomplete). RESULTS: We studied 229 subjects with acute SCI. Persons with injury to the cervical or thoracic spinal cord and who were (or became) motor-incomplete showed large tendon responses, even at the time of initial evaluation. In combination with larger tendon response amplitudes, the presence of the 'crossed-adductor' response to patellar tendon taps at the acute stage was highly predictive of functional motor recovery following SCI. In marked contrast, tendon responses were small (e.g. < 0.1 mV) or absent in persons with acute, motor-complete injury (and which remained motor-complete), and the crossed-adductor response was never seen. Reflex amplitudes and the incidence of the crossed-adductor response increased somewhat over time in persons with motor-complete SCI, but did not approach the values seen in motor-incomplete subjects. CONCLUSIONS: Taken together, tendon response amplitude and reflex spread were sensitive and specific indicators of preserved supraspinal control over lower limb musculature in subjects with acute SCI. A simple algorithm using these outcome measures predicted a 'motor-complete' status with 100% accuracy, and a motor-incomplete status with accuracy exceeding 91%.

Achilles Tendon↗

Improving the prediction of final infarct size in acute stroke with bolus delay-corrected perfusion MRI measures.

PURPOSE: To investigate whether bolus delay-corrected dynamic susceptibility contrast (DSC) perfusion MRI measures allowed a more accurate estimation of eventual infarct volume in 14 acute stroke patients using a predictive tissue classifier algorithm. MATERIALS AND METHODS: Tissue classification was performed using a expectation maximization and k-means clustering algorithm utilizing diffusion and T2 measures (diffusion-weighted imaging [DWI], apparent diffusion coefficient [ADC], and T2) combined with uncorrected perfusion measures cerebral blood flow ((CBF) and mean transit time [MTT]), bolus delay-corrected perfusion measures (cCBF and cMTT), and bolus delay-corrected perfusion indices (cCBF and cMTT with bolus delay). RESULTS: The mean similarity index (SI), a kappa-based correlation statistic reflecting the pixel-by-pixel classification agreement between predicted and 30-day T2 lesion volumes, were 0.55 +/- 0.19, 0.61 +/- 0.15 (P < 0.02) and 0.60 +/- 0.17 (P <0.03), respectively. Spearman's correlation coefficients, comparing predicted and final lesion volumes were 0.56 (P < 0.05), 0.70 (P < 0.01), and 0.84 (P < 0.001), respectively. We found a more significant correlation between predicted infarct volumes derived from bolus delay-corrected perfusion measures than from conventional perfusion measures when combined with diffusion measures and compared with final lesion volumes measured on 30-day T2 MRI scans. CONCLUSION: Bolus delay-corrected perfusion measures enable an improved prediction of infarct evolution and evaluation of the hemodynamic status of neuronal tissue in acute stroke.

Acute Disease↗

Muscle synergies and joint linkages in sit-to-stand under two initial foot positions.

OBJECTIVE: The purpose of this study was to investigate the activation pattern of six lower limb muscles during standing up from two initial foot positions and to examine relationships between the onsets of muscle activity and the dynamics of the action. In contrast to earlier studies, an algorithm was used to measure onsets and duration of muscle activity. METHOD: The activity of biceps femoris, rectus femoris, vastus lateralis, tibialis anterior, lateral gastrocnemius and medial soleus was studied as nine male subjects between the ages of 20 and 35 stood up from two initial foot positions (foot forward, foot back). Subjects sat on a height-adjustable seat with their right foot on a force platform and were videotaped as they stood up. RESULTS: When the feet were forward there were significant increases in movement duration, displacement and velocity of trunk segment flexion at the hips reflecting the increased distance the body mass must be moved forward. The sequence of onsets and the duration of muscle activity, however, were consistent across the two conditions. Onsets of extension at hip, knee and ankle, however, correlated with different muscle activity depending on the foot position. CONCLUSION: The results suggest that muscles working over different joints are temporally linked and that different muscle linkages may be utilised in the lower limb to coordinate the sit-to-stand action under different functional demands.

Adult↗

Use of alpha spectroscopy for conducting rapid surveys of transuranic activity on air sample filters and smears.

This paper demonstrates the utility of a portable alpha Continuous Air Monitor (CAM) as a bench top scalar counter for multiple sample types. These include using the CAM to count fixed air sample filters and radiological smears. In counting radiological smears, the CAM is used very much like a gas flow proportional counter (GFPC), albeit with a lower efficiency. Due to the typically low background in this configuration, the minimum detectable activity for a 5-min count should be in the range of about 10 dpm which is acceptably below the 20 dpm limit for transuranic isotopes. When counting fixed air sample filters, the CAM algorithm along with other measurable characteristics can be used to identify and quantify the presence of transuranic isotopes in the samples. When the radiological control technician wants to take some credit from naturally occurring radioactive material contributions due to radon progeny producing higher energy peaks (as in the case with a fixed air sample filter), then more elaborate techniques are required. The techniques presented here will generate a decision level of about 43 dpm for such applications. The calibration for this application should alternatively be done using the default values of channels 92-126 for region of interest 1. This can be done within 10 to 15 min resulting in a method to rapidly evaluate air filters for transuranic activity. When compared to the 1-h count technique described by , the technique presented in the present work demonstrates a technique whereby more than two thirds of samples can be rapidly shown (within 10 to 15 min) to be within regulatory compliant limits. In both cases, however, spectral quality checks are required to insure sample self attenuation is not a significant bias in the activity estimates. This will allow the same level of confidence when using these techniques for activity quantification as is presently available for air monitoring activity quantification using CAMs.

Air Pollutants, Radioactive↗

Automated morphometric analysis of the cat retinal alpha/Y, beta/X and delta ganglion cells using wavelet statistical moment and clustering algorithms.

Computational morphological analysis comprises the development of measures (indicators) that describe different form attributes of a neuron and provides additional parameters for classification algorithms. Our work addressed the problem of small group sizes often encountered in neuromorphological and neurophysiological research, automated classification tasks (unsupervised learning) and introduced a new morphological measure: the wavelet statistical moment. We analysed cat alpha/Y, beta/X and delta Golgi-stained retinal ganglion cells using six different shape features (circularity, 2(nd) statistical moment and entropy of Gaussian blurred images, wavelet statistical moment, number of terminations and the fractal dimension). This allowed us to compare the sensitivity of the methods in uniquely describing morphological attributes of these cells.

Algorithms↗

Left ventricular shape index assessed by gated stress myocardial perfusion SPECT: initial description of a new variable.

BACKGROUND: Ventricular remodeling is predictive of congestive heart failure (CHF). We aimed to automatically quantify a new myocardial shape variable on gated myocardial perfusion single photon emission computed tomography (SPECT) (MPS) and to evaluate the association of this new SPECT parameter with the risk of hospitalization for CHF. METHODS AND RESULTS: A computer algorithm was used to measure the 3-dimensional (3D) left ventricular (LV) shape index (LVSI), derived as the ratio of maximum 3D short- and long-axis LV dimensions, for end systole and end diastole. LVSI normal limits were obtained from stress technetium 99m sestamibi MPS images of 186 patients (60% of whom were men) (control subjects) with a low likelihood of CAD (< 5%). These limits were tested in a consecutive series of 93 inpatients (85% of whom were men) having MPS less than 1 week after hospitalization, of whom 25 were hospitalized for CHF exacerbation. Variables associated with CHF hospitalization were tested by receiver operating characteristic curve and multivariate logistic regression analyses. LVSI repeatability was assessed in 52 patients with ischemic cardiomyopathy who had sequential stress MPS within 60 days after the initial MPS without clinical events in the interval between MPS studies. Control subjects had lower end-systolic and end-diastolic LVSIs compared with patients with CHF and those without CHF (P < .001). Receiver operating characteristic curve areas for the prediction of hospitalization as a result of CHF were similar for LV ejection fraction and end-systolic LVSI. End-systolic and end-diastolic LVSIs were independent predictors of CHF hospitalization by multivariate analysis; however, end-systolic LVSI had the greatest added value among all tested variables. Repeatability was excellent for both end-systolic LVSI (R2 = 0.85, P < .0001) and end-diastolic LVSI (R2 = 0.82, P < .001). CONCLUSION: LVSI is a promising new 3D variable derived automatically from gated MPS providing highly repeatable ventricular shape assessment. Preliminary findings suggest that LVSI might have clinical implications in patients with CHF.

Adult↗

Clinical evaluation of scanning laser polarimetry: I. Intraoperator reproducibility and design of a blood vessel removal algorithm.

AIMS: To evaluate the reproducibility of the retardation values (change in polarisation) obtained with the scanning-laser polarimeter in a series of normal subjects and glaucoma patients. To improve the analysis of the raw data by devising and evaluating a blood vessel removal algorithm. METHODS: Scanning laser polarimetry was performed on 10 normal subjects and 10 glaucoma patients. A series of six images was obtained from each eye. The normal subjects were re-imaged 3 months after their initial assessment. The retardation values obtained from each eye were analysed using the authors' own methods, including the use of an algorithm to remove blood vessels from the polar profiles. The reproducibility of these measurements and the performance of the blood vessel removal algorithm were assessed. RESULTS: The "individual point" coefficient of variation was approximately 12.5% for normal subjects and 17.0% for glaucoma patients. The "integral" coefficient of variation for these groups was approximately 5.5% and 9.5% respectively. The reproducibility of the measurements did not improve with an increased number of measurements. There was no difference in the reproducibility of the measurements in normal subjects over time. The blood vessel removal algorithm improved the reproducibility of the measurements when the shape of the profile was assessed. CONCLUSION: The intraoperator reproducibility of retardation values obtained with the scanning laser polarimeter is satisfactory for its use as a clinical tool. The use of a blood vessel removal algorithm improves the reproducibility of the measurements and also assists the clinician in the interpretation of the polar profiles. Furthermore, it allows the construction of normal database polar profiles, thereby enabling the identification, location and quantification of retinal nerve fibre layer damage in an "at risk" individual's polar profile.

Algorithms↗

Applicability of the single equivalent moving dipole model in an infinite homogeneous medium to identify cardiac electrical sources: a computer simulation study in a realistic anatomic geometry torso model.

We have previously proposed an inverse algorithm for fitting potentials due to an arbitrary bio-electrical source to a single equivalent moving dipole (SEMD) model. The algorithm achieves fast identification of the SEMD parameters by employing a SEMD model embedded in an infinite homogeneous volume conductor. However, this may lead to systematic error in the identification of the SEMD parameters. In this paper, we investigate the accuracy of the algorithm in a realistic anatomic geometry torso model (forward problem). Specifically, we investigate the effect of measurement noise, dipole position and electrode configuration in the accuracy of the algorithm. The boundary element method was used to calculate the forward potential distribution at multiple electrode positions on the body surface due to a point dipole in the heart. We have found that the position and not the number of electrodes as well as the site of the origin of the arrhythmia in the heart have a significant effect on the accuracy of the inverse algorithm, while the measurement noise does not. Finally, we have shown that the inverse algorithm preserves the topology of the source distribution in the heart, thus potentially allowing the cardiac electrophysiologist to efficiently and accurately guide the tip of the catheter to the ablation site.

Action Potentials↗