PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Rapid screening procedure based on headspace solid-phase microextraction and gas chromatography-mass spectrometry for the detection of many recreational drugs in hair.

An increasing number of synthetic drugs are appearing on the illicit market and on the scene of drug use by youngsters. Official figures are underestimated. In addition, immunochemical tests are blind to many of these drugs and appropriate analytical procedures for routine clinical and epidemiological purposes are lacking. Therefore, the perceived increasing abuse of recreational drugs has not been proved yet. In a previous paper, we proposed a procedure for the preliminary screening of several recreational substances in hair and other biological matrices. Unfortunately, this procedure cannot apply to cocaine. Consequently, we performed a new headspace solid-phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC-MS) procedure for the simultaneous detection of cocaine, amphetamine (A), methamphetamine (MA), methylen-dioxyamphetamine (MDA), methylen-dioxymethamphetamine (MDMA), methylen-dioxyethamphetamine (MDE), N-methyl-1-(1,3-benzodioxol-5-yl)-2-butanamine (MBDB), ketamine, and methadone in human hair. Hair was washed with water and acetone in an ultrasonic bath. A short acid extraction with 1M hydrochloric acid was needed; the fiber was exposed to a 5 min absorption at 90 degrees C and thermal desorption was performed at 250 degrees C for 3 min. The procedure was simple, rapid, required small quantities of sample and no derivatization. Good linearity was obtained over the 0.1-20.0 ng/mg range for the target compounds. Sensitivity was good enough: limits of detection (LOD) were 0.7 ng/mg of hair for the majority of substances. The intra-day precision ranged between 7 and 20%. This paper deals with the analytical performance of this procedure and its preliminary application to hair samples obtained on a voluntary basis from 183 young people (138 males and 45 females) in the Rome area.

Adolescent↗

The use of solid-phase microextraction in conjunction with a benchtop quadrupole mass spectrometer for the analysis of volatile organic compounds in human blood at the low parts-per-trillion level.

The analysis of volatile organic compounds (VOCs) in whole human blood at the low parts-per-trillion level has until recently required the use of a high-resolution mass spectrometer to obtain the specificity and detection limits required for epidemiological studies of VOC exposure in the general public. Because of the expense and expertise required to operate and maintain a high-resolution instrument, the applicability of this method has been limited. These limitations are overcome in a new method using automated headspace solid-phase microextraction (SPME) in conjunction with a gas chromatograph and a benchtop quadrupole mass spectrometer. A combination of SPME and multiple single-ion monitoring minimizes the interferences and chemical noise associated with whole blood samples. This method permits the analysis of 10 VOCs in human blood while simplifying the sample preparation and reducing the possible exposure of the analyst to blood aerosols. Twelve samples can be run successively in a fully automated mode, thus eliminating the need for operator attention. Detection limits are below 50 ppt (pg/mL) for a majority of the VOCs tested with a 5-mL sample.

Calibration↗

Investigation by solid-phase microextraction and gas chromatography/mass spectrometry of secondary metabolites in lichens deposited on stone monuments.

Lichens are ubiquitous organisms formed by symbiotic associations of fungal hyphas and algae that also grow under often extreme environmental conditions. They produce secondary metabolites, the so-called lichen substances, whose structural characterization can give an important contribution to lichen taxonomy. Lichens are also widely employed as biomonitors of atmospheric pollution; being epiphyte organisms they tend, in fact, to accumulate exogenous compounds. Moreover, it could be questioned if the environmental stress alters their secondary metabolites production. Therefore, a new strategy for the analysis of the organic substances absorbed or metabolized by lichens has been developed. This method exploits the dry solid-phase microextraction (SPME) headspace technique coupled with gas chromatography/mass spectrometry (GC/MS). Lichens coating the stone surfaces of monuments, located in small towns between high mountains and far away from urban environments, have been investigated. In the field of cultural heritage, this study can contribute to the knowledge of the state of conservation of outdoor exposed historical monuments.

Benzofurans↗

Headspace solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) for the determination of 5alpha-androst-2-en-17-one and -17beta-ol in the female Asian elephant: application for reproductive monitoring and prediction of parturition.

Asian elephants are not self-sustaining in captivity. The main reasons for this phenomenon are a low birth rate, an aging population, and poor calf-rearing. Therefore, it is essential that reproductive rates had to be improved and there is need for rapid quantitative measures to monitor reproductive functions focussing on estrous detection and the prediction of the period of parturition. The objective of this study was to develop a method which combines headspace solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) for analyses of 5alpha-androst-2-en-17beta-ol and -17-one to prognose estrous and to predict the period of parturition. SPME was carried out with a CTC Combi Pal system. The course of the luteal phase-specific substance 5alpha-androst-2-en-17beta-ol and -17-one followed a cyclic pattern in which the follicular and luteal phases could be clearly distinguished (mean estrous cycle length, 15+/-1.4 weeks). Based on daily urine samples, estrous prognosis might be possibly based on the initial 5alpha-androst-2-en-17beta-o1 increase at the end of the follicular phase. Parturition prognosis was performed in three elephant cows based on the 5alpha-androst-2-en-17beta-o1 drop to baseline levels 5-4 days prior parturition. Experiments revealed that 5alpha-androst-3alpha-ol-17-one and probably 5alpha-androst-3alpha-ol-17beta-ol are generated from sulfate conjugates by a thermal process.

Androstane-3,17-diol↗

Characterization of volatile organic compounds and odorants associated with swine barn particulate matter using solid-phase microextraction and gas chromatography-mass spectrometry-olfactometry.

Swine operations can affect air quality by emissions of odor, volatile organic compounds (VOCs) and other gases, and particulate matter (PM). Particulate matter has been proposed to be an important pathway for carrying odor. However, little is known about the odor-VOCs-PM interactions. In this research, continuous PM sampling was conducted simultaneously with three collocated TEOM 1400a analyzers inside a 1000-head swine finish barn located in central Iowa. Each TEOM was fitted with total suspended particulate (TSP), PM-10, PM-2.5 and PM-1 preseparators. Used filters were stored in 40 mL vials and transported to the laboratory. VOCs adsorbed/absorbed to dust were allowed to equilibrate with vial headspace. Solid-phase microextraction (SPME) Carboxen/polydimethylsiloxane (PDMS) 85 microm fibers were used to extract VOCs. Simultaneous chemical and olfactometry analyses of VOCs and odor associated with swine PM were completed using a gas chromatography-mass spectrometry-olfactometry (GC-MS-O) system. Fifty VOCs categorized into nine chemical function groups were identified and confirmed with standards. Five of them are classified as hazardous air pollutants. VOCs were characterized with a wide range of molecular weight, boiling points, vapor pressures, water solubilities, odor detection thresholds, and atmospheric reactivities. All characteristic swine VOCs and odorants were present in PM and their abundance was proportional to PM size. However, the majority of VOCs and characteristic swine odorants were preferentially bound to smaller-size PM. The findings indicate that a significant fraction of swine odor can be carried by PM. Research of the effects of PM control on swine odor mitigation is warranted.

Animals↗

Solid-phase microextraction of volatile components from natural grassland plants.

The volatile components from nine plants growing on natural grasslands in Auvergne, central France, selected for the broad qualitative and quantitative diversity of their terpenoid fractions, were analyzed by high-resolution gas-phase chromatography and mass spectrometry (HRGC-MS) after static headspace solid-phase microextraction (SHS-SPME). SHS-SPME allowed all the plant material to be analyzed under the same conditions despite its wide-ranging composition. This is not always possible with other extraction methods. Using an apolar poly(dimethylsiloxane) (PDMS) phase, numerous terpenoid hydrocarbons, together with alcohols, cyclic ethers, and esters, were extracted. Its ease of use and the high resolution of the chromatographic profiles obtained make SHS-SPME well suited to the rapid characterization of the main components of the volatile fraction of plants. Of the nine plants studied, four (Meum athamanticum, Pimpinella saxifraga, Achillea millefolium, and Thymus pulegioides) exhaled more than 60 different volatile components. Certain terpenes present in large amounts in these plants might help link dairy products to grazing pasture, thus improving food traceability.

Alcohols↗

Determination of specific volatile organic compounds synthesised during Tuber borchii fruit body development by solid-phase microextraction and gas chromatography/mass spectrometry.

Fruit body development is a particular phase of the Tuber life cycle, characterised by the aggregation of different types of hyphae, i.e., vegetative hyphal cells and highly specialised reproductive hyphae (asci). In order to identify the volatile organic compounds (VOCs) produced in different stages of the Tuber borchii ripening fruit body, solid-phase microextraction with gas chromatography and mass spectrometry was used. The volatile organic compounds were extracted using a DVB/CAR/PDMS 50/30 microm fiber placed for 10 min at room temperature in the truffle headspace. The results obtained reveal 49 compounds each of which was present only in a particular stage of maturation. 1-octen-3-ol, aromadendrene, alpha-farnesene and other terpenoid compounds were of particular interest, and their possible biological roles are discussed. The production of aromadendrene in the completely unripe fruit body suggests the existence of communication events in the early stage of ascomata formation between the fungus and the host plant. alpha-Farnesene could represent a chemotactic attractant to saprophytic organisms in order to disperse the fungal spores in the environment. The identification of the VOCs produced by truffles during their maturation could give information about the processes underlying this phase of Tuber life cycle.

Ascomycota↗

Solid-phase microextraction liquid chromatography/tandem mass spectrometry for the analysis of chlorophenols in environmental samples.

Liquid chromatography with atmospheric pressure chemical ionisation mass spectrometry (LC/APCI-MS), using negative ion detection in a triple quadrupole instrument, was used for the determination of chlorophenols (CPs) in environmental samples. In-source collision-induced dissociation (CID) was compared with MS/MS fragmentation. In general, less fragmentation was observed in MS/MS as compared with in-source CID, with the latter providing more intense fragment ions due to chemical ionisation. Under MS/MS conditions [M - H - HCl](-) was the main fragment ion observed for all compounds except for pentachlorophenol, which showed no fragmentation. For multiple reaction monitoring (MRM) acquisition mode, the transition from [M - H](-) to [M - H - HCl](-) was selected, leading to detection limits down to 0.3 ng injected. Direct and headspace-solid-phase microextraction (HS-SPME) were used as preconcentration procedures for the analysis of CPs in wood and in industrially contaminated soils. CPs were quantified by standard addition, which led to good reproducibility (RSD between 4 and 11%) in both SIM and MRM modes, and detection limits down to ng/g. The combination of MS/MS and in-source CID allowed confirmation of the presence of CPs in environmental samples.

Chlorophenols↗

Optimization of solid-phase microextraction for the gas chromatographic-mass spectrometric determination of synthetic musk fragrances in water samples.

Described is a solid-phase microextraction-gas chromatography-mass spectrometric procedure for the determination of three polycyclic musk fragrances (galaxolide, tonalide, celestolide) and a nitro musk fragrance (musk ketone) in natural river water. Both classes of the musk fragrances could be extracted reproducibly from water samples with a recovery in the range of 45-50% and relative standard deviation of 11-18% for fragrances at 25-260 ng/l levels. Detection limits were between 14 and 22 ng/l. To achieve this reproducibility it was necessary to use an internal standard, pentachloronitrobenzene, for all substances. Best recoveries were achieved with polydimethylsiloxane (PDMS)-divinylbenzene fibers (compared to recoveries obtained with PDMS, polyacrylate or carboxen fibers) and extraction times of 45 min at 30 degrees C, with no need for attainment of equilibrium conditions. The latter was achieved at about 2 h. For Elbe River water, in the vicinity of Magdeburg, no matrix effects were observed. While the average levels of celestolide and musk ketone for samples investigated were below the detection limits, 14 and 22 ng/l, respectively, and for tonalide below the limit of quantification, 22 ng/l, the ambient levels of galaxolide in the Elbe River were 117 ng/l.

Fatty Acids, Monounsaturated↗

Solid-phase microextraction coupled to gas chromatography-mass spectrometry for the study of soil adsorption coefficients of organophosphorus pesticides.

A solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method for the simultaneous determination of the organophosphorus pesticides (OPPs), phorate, diazinon, methyl-parathion, fenitrothion, malathion, fenthion, ethyl-parathion and methidathion, has been developed to study their soil/water distribution. The method was used in conjunction with a conventional 'batch equilibrium method' to assess the soil adsorption coefficients (Koc) of the target compounds in different soil samples with known organic carbon content. Contrary to traditional techniques, the present method is fast, solvent-free and highly sensitive, thus permitting the assessment of the Koc values of the target compounds even at low soil concentration levels, close to those encountered in real field contamination, where the Freudlich adsorption isotherms can be considered to be linear. The estimated Koc values were found to be in good agreement with those reported in the literature.

Chemistry Techniques, Analytical↗

Determination of low-level residual ethylene oxide by using solid-phase microextraction and gas chromatography.

Current methods of analysis for ethylene oxide (EO) in medical devices include headspace and simulated-use extractions followed by gas chromatography with either a packed or a capillary column. The quantitation limits are about 0.5-1.0 microg/g for a packed column and about 0.1-0.2 microg/g for a capillary column. The current allowable levels of EO on medical devices sterilized with EO gas as outlined in International Organization for Standardization (ISO) 10993-7 may be significantly reduced from current levels by applying the ISO Draft International Standard 10993-17 method for establishing allowable limits. This may require EO test methods with detection and quantitation limits that are much lower than those of the currently available methods. This paper describes a new method that was developed for the determination of low-level EO by solid-phase microextraction using the direct-immersion method. Factors such as temperature and stirring were found to affect absorption efficiency and absorption time. A low extraction temperature (about 6 degrees C) was found to be more efficient than room-temperature extraction. Stirring was found to reduce absorption time by about 50%. Under these conditions, detection and quantitation limits of 0.002 and 0.009 microg/g, respectively, were obtained by using a capillary column. As a result, this method makes compliance with lower EO limits feasible.

Calibration↗

Monitoring the sonochemical degradation of phthalate esters in water using solid-phase microextraction.

The sonochemical degradation of aqueous solutions containing low concentrations of six phthalate esters at an ultrasonic frequency of 80 kHz has been investigated. Ultrasonic treatment was found capable of removing the four higher molecular mass phthalates (di-n-butyl phthalate, butylbenzyl phthalate, di-(2-ethylhexyl) phthalate and di-n-octyl phthalate) within 30-60 min of irradiation. The rest (dimethyl phthalate and diethyl phthalate) were more recalcitrant and nearly complete removal could be achieved only after prolonged irradiation times. The relative reactivity of phthalates was explained in terms of their hydrophobicity. Experiments were carried out at an overall initial phthalate concentration of 240 microg l(-1), values of electric power of 75 and 150 W, temperatures of 21 and 50 degrees C and in the presence of NaCl to study the effect of various operating conditions on degradation. Solid-phase microextraction (SPME) coupled with GC-MS proved to be a powerful analytical tool to monitor the sonochemical degradation of phthalate esters at low microg l(-1) concentration levels, minimising the risk of secondary contamination during sample preparation, a major parameter to consider during phthalates analysis. The advantages as well as disadvantages of using SPME are also highlighted.

Esters↗

Use of solid-phase microextraction for measuring oil-water partition coefficients and correlation with high-performance liquid chromatographic methods for lipophilicity.

For flavour compounds, lipophilicity is often estimated by the partition coefficient between oil and water (log Koil-water), which is highly relevant to food. A modification of the shake-flask method is reported here where compounds are quantified in the two phases using solid-phase microextraction (SPME). SPME's highly sensitivity to non-polar compounds facilitates quantification in the water phase. Twelve flavour compounds representing a broad range of lipophilicities and functional groups were analysed by two methods. Their log Koil-water was determined using SPME quantitation and their log k(w) using a reversed-phase HPLC methodology. The isocratic capacity factor at 60% methanol and predicted log P value also showed high correlation factors with other methods. The octadecyl silylated surface of the HPLC column provides a matrix that interacts with lipophilic compounds where the retention time is the indication of lipophilicity. Both methods gave reproducible results (median 3% and 4% RSD) and similar but not identical values for lipophilicity. The relationship between the two methods is log k(w) =0.85 log Koil-water +0.48 with a correlation coefficient of 0.94. The new SPME detection method, with the ability to quantify limonene and 2-pentylfuran at 1 ppm in the water phase, is preferred for flavour compound analysis due to the applicability of oil-water partitioning in food.

Buffers↗

Characterization of the volatile fraction emitted by phloems of four pinus species by solid-phase microextraction and gas chromatography-mass spectrometry.

Pine forests constitute some of the most important renewable resources supplying timber, paper and chemical industries, among other functions. Characterization of the volatiles emitted by different Pinus species has proven to be an important tool to decode the process of host tree selection by herbivore insects, some of which cause serious economic damage to pines. Variations in the relative composition of the bouquet of semiochemicals are responsible for the outcome of different biological processes, such as mate finding, egg-laying site recognition and host selection. The volatiles present in phloem samples of four pine species, P. halepensis, P. sylvestris, P. pinaster and P. pinea, were identified and characterized with the aim of finding possible host-plant attractants for native pests, such as the bark beetle Tomicus piniperda. The volatile compounds emitted by phloem samples of pines were extracted by headspace solid-phase micro extraction, using a 2cm 50/30mm divinylbenzene/carboxen/polydimethylsiloxane table flex solid-phase microextraction fiber and its contents analyzed by high-resolution gas chromatography, using flame ionization and a non polar and chiral column phases. The components of the volatile fraction emitted by the phloem samples were identified by mass spectrometry using time-of-flight and quadrupole mass analyzers. The estimated relative composition was used to perform a discriminant analysis among pine species, by means of cluster and principal component analysis. It can be concluded that it is possible to discriminate pine species based on the monoterpenes emissions of phloem samples.

Animals↗

Rapid differentiation of new apple cultivars by headspace solid-phase microextraction in combination with chemometrical data processing.

The aim of this study was to test a combination of automated headspace solid phase-microextraction gas chromatography (GC) with chemometrical data treatment for the rapid differentiation of enzyme-inactivated homogenates of new apple cultivars. The four cultivars Pinova, Piflora, Renora and Florina are characterized by different volatile patterns. Differences in the contents of volatiles were especially found for butyl acetate, ethyl butanoate, 2-methyl butanol, ethyl acetate and 6-methyl-5-hepten-2-ol. The used sample preparation method for GC coupled with pattern recognition of chromatograms is a useful tool for rapid and reliable determination of large numbers of samples.

Chromatography, Gas↗

New high-performance cryofocalizer injector for in-tube solid-phase microextraction and headspace capillary gas chromatographic applications.

The construction of a high-efficiency but cheap injector for volatile and very volatile compounds is shown. The device focuses the compounds in a fused-silica (FS) transfer capillary with the aid of liquid nitrogen. A 6.2 mm O.D. glass tube liner (ca. 25 cm x 1.5 mm I.D.) is inserted in the heated (-200 degrees C) injector of the gas chromatograph in place of the standard glass liner, and extends further externally through a liquid nitrogen container made with styrofoam-like material. Inside this glass tube, the FS transfer line passing through the oven door is connected like a pre-column to the analytical high-resolution GC column. It can move fast between the heated and the cooled zone (<-->, deltaL = 13 cm), and when this movement starts, crvofocused analytes are injected "at once" resulting in symmetrical and sharp injection bands with "zero" carryover. The performance of this device is demonstrated by its application to in-tube solid-phase microextraction and to spice volatiles analysis.

Chromatography, Gas↗

Application of solid-phase microextraction and gas chromatography-mass spectrometry to the determination of volatile organic compounds in end-exhaled breath samples.

Analysis of exhaled air is of particular interest as an indicator of health as well as a tool for the diagnosis of diseases. It is also a very attractive procedure for the biological control of the exposition to hazardous solvents. This kind of analysis presents numerous advantages over other methods, the most important being that it is not an invasive procedure and, therefore, it is well accepted and can be applied to a wide range of compounds. Furthermore, the analysis is simplified since the matrix is less complex that in the case of blood or urine. In spite of these obvious advantages and the good results obtained, analysis of exhaled air is not in daily use, probably due to the fact that there are no normalized systems of sampling, thus making the interpretation of the results difficult. In this paper, a method for the determination of tetrachloroethylene in exhaled air using solid-phase microextraction is presented. This method, which can be applied to other volatile organic compounds, was developed with special emphasis of end-exhaled breath sampling. The sample is collected in a glass tube whose ends are closed once the exhalation is finished. The tube has an orifice sealed with a septum through which the fiber is inserted. Then, the fiber is desorbed in the injector of a gas chromatograph and the analysis is accomplished using mass spectrometry for the identification and quantification of the components. The proposed system avoids the need of complex sampling equipment and allows analysis of the alveolar fraction. Additionally, the system is economical and easy to handle, thus facilitating the development of normalized methods and its routine use in field studies.

Breath Tests↗

Assessing the aquatic toxicity of complex hydrocarbon mixtures using solid phase microextraction.

Assessing the ecotoxicity of hydrocarbon mixtures is complicated by the complex nature of these mixtures. Traditional analytical methods for characterizing hydrocarbon contamination are not good predictors of potential ecotoxicity because these methods fail to characterize the bioavailability of individual hydrocarbon components. Recent research indicates that hydrocarbons act by a common narcotic mode of action and that ecotoxicity occurs when the molar concentration in organism lipid exceeds a critical threshold. Since the ecotoxicity of narcotic mixtures appears to be additive, ecotoxicity thus depends upon the partitioning of individual hydrocarbons from the environment to lipids and the total molar sum of individual hydrocarbons in lipids. These insights have led previous investigators to advance the concept of 'biomimetic' extraction as a novel analytical tool for assessing narcosis-type or 'baseline'. Drawing from this earlier work, a simple method to quantify bioavailable petroleum hydrocarbons (BPHs) in hydrocarbon-contaminated aqueous and soil/sediment samples was developed. The proposed method combines the essential features of biomimetic extraction for simulating the bioconcentration process with the analytical advantages of solid phase microextraction (SPME). The procedure for determining BPH involves two steps. The sample is first equilibrated with a SPME fiber that serves as a surrogate for organism lipids. The total moles of hydrocarbons that partition to the SPME fiber is then quantified using GC/FID. The capability of this method to predict ecotoxicity was assessed by comparing BPH measurements for hydrocarbon contaminated aqueous samples to corresponding toxicity test results for rainbow trout. Results indicate that BPH analyses correlate to the observed acute toxicity. Consequently, BPH analyses offer a promising, cost-effective screening tool for predicting aquatic toxicity of complex hydrocarbon mixtures.

Animals↗