PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50Linked to original sources

Detection of influenza virus: traditional approaches and development of biosensors.

Influenza is an acute respiratory disease caused by the influenza virus. The disease occurs annually, causing fatality in the elderly and children and billions of dollars loss in business and productivity. Traditional viral detection methods include MDCK cell culture, complement fixation, hemagglutinin-inhibition, and recently RT-PCR. Although effective, these methods generally involve labor-intensive laboratory procedures and often require trained personnel to carry them out. The development of biosensor technologies will enable rapid and specific disease diagnosis on-site so that a clinician can quickly determine whether treatment is needed. This paper reviews traditional viral assays and progress in the biosensor development for influenza virus. Recent advances in single-step direct detection using non-labeling techniques such as surface plasmon resonance, quartz-crystal microbalance, and colorimetric functional polymers are discussed.

Antiviral Agents↗

An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane.

An optical glucose biosensor using a swim bladder membrane as an enzyme immobilization platform and an oxygen-sensitive membrane as an optical oxygen transducer has been developed. During the enzymatic reaction, glucose is oxidized by glucose oxidase with a concomitant consumption of dissolved oxygen resulting in an increase in the fluorescence intensity of the optical oxygen transducer. The fluorescence intensity is directly related to the glucose concentration. The effects of pH, temperature, buffer concentration, and selectivity have been studied in detail. The immobilized enzyme retained 80% of its initial activity after being kept for more than 10 months at 4 degrees C. The glucose biosensor has been successfully applied to the determination of glucose content in human blood serum and urine samples.

Air Sacs↗

Biosensors based on carbon nanotubes.

Carbon nanotubes (CNTs) exhibit a unique combination of excellent mechanical, electrical and electrochemical properties, which has stimulated increasing interest in the application of CNTs as components in (bio)sensors. This review highlights various design methodologies for CNT-based biosensors and their employment for the detection of a number of biomolecules. In addition, recent developments in the fields of CNT-based chemiresistors and chemically sensitive field-effect transistors are presented. After a critical discussion of the factors that currently limit the practical use of CNT-based biosensors, the review concludes with an outline of potential future applications for CNTs in biology and medicine.

Biosensing Techniques↗

L-glutamate biosensor for estimation of the taste of tomato specimens.

An amperometric biosensor has been developed for measurement of Umami, or the taste based on the amount of L-glutamate, in tomato foods. The biosensor is based on an enzyme-mediator system in which L-glutamate oxidase is used for biochemical oxidation of L-glutamate and a tetrafulvalene-tetracyanoquinodimethane (TTF-TCNQ) paste, prepared from the mixture of TTF-TCNQ salt, graphite powder, and silicone oil, serves as the mediator. The limit of detection, calculated by use of a four-parameter logistic model, was 0.05 mmol L(-1), and the limit of quantification was 0.15 mmol L(-1). The correlation coefficient (R2) was 0.990 and the relative standard deviation was no more than 1% (n=5). The response time (tau (95)) was 20-50 s, depending on concentration. The repeatability of the sensor was better than 5% (n=10). The sensor developed was stable for more than ten days.

Amino Acid Oxidoreductases↗

Reversible immobilization of proteins with streptavidin affinity tags on a surface plasmon resonance biosensor chip.

Dissociation of biotin from streptavidin is very difficult due to their high binding affinity. The re-use of streptavidin-modified surfaces is therefore almost impossible, making devices containing them (e.g. surface plasmon resonance (SPR) sensor chips) expensive. This paper describes a new protocol for reversible and site-directed immobilization of proteins with streptavidin affinity tags on the streptavidin-coated SPR biosensor chip (SA chip). Two streptavidin affinity tags, nano-tag and streptavidin-binding peptide (SBP tag), were applied. They both can specifically interact with streptavidin but have weaker binding force compared to the biotin-streptavidin system, thus allowing association and dissociation under controlled conditions. The SA chip surface could be regenerated repeatedly without loss of activity by injection of 50 mM NaOH solution. The fusion construct of a SBP tag and a single-chain antibody to mature bovine prion protein (scFv-Z186-SBP) interacts with the SA chip, resulting in a single-chain-antibody-modified surface. The chip showed kinetic response to the prion antigen with equilibrium dissociation constant K (D) approximately equal to 4.01 x 10(-7). All results indicated that the capture activity of the SA chip has no irreversible loss after repeated immobilization and regeneration cycles. The method should be of great benefit to various biosensors, biochips and immunoassay applications based on the streptavidin capture surface.

Animals↗

Electron-transfer properties of different carbon nanotube materials, and their use in glucose biosensors.

Different types of carbon nanotube material (single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs) of different internal diameter) have been used for preparation of CNT-modified glassy-carbon electrodes. Redox reactions involving ferricyanide and hydrogen peroxide were examined at the CNT-modified electrodes. Electrodes modified with SWCNTs usually had better electron-transfer properties than MWCNT-modified electrodes. Glucose biosensors were also prepared with electropolymerized polyphenylenediamine films, CNT materials, and glucose oxidase. Amperometric behavior in glucose determination was examined. SWCNT-modified glucose biosensors usually had a wider dynamic range (from 0.1 to 5.5 mmol L-1) and greater sensitivity in glucose determination. The detection limit was estimated to be 0.05 mmol L-1.

Biosensing Techniques↗

Identification of bacterial N-acylhomoserine lactones (AHLs) with a combination of ultra-performance liquid chromatography (UPLC), ultra-high-resolution mass spectrometry, and in-situ biosensors.

N-Acylated homoserine lactones (AHLs) are produced by Gram-negative bacteria as communication signals and are frequently studied as mediators of the "quorum sensing" response of bacterial communities. Several reports have recently been published on the identification of AHLs from different species and attempts have been made to study their role in natural habitats, for example the surface of plant roots in the rhizosphere. In this article, different analytical methods, including bacterial biosensors and chromatographic techniques, are reviewed. A concept for assignment of the structures of AHLs is also presented. The retention behaviour of derivatives of AHLs containing beta-keto or hydroxyl groups and/or double bonds has been evaluated in relation to the separation behaviour of AHLs with saturated and unsubstituted alkanoyl chains. Samples have also been analysed by high resolution mass spectrometry (Fourier-transform ion-cyclotron-resonance mass spectrometry, FTICR-MS), nano liquid chromatography-electrospray ionization ion trap mass spectrometry (nano-LC-MS) and by the aid of a biosensor. The results obtained from ultra performance liquid chromatography (UPLC), FTICR-MS, nano-LC-MS, and bioassays have been compared to attempt structural characterisation of AHL without chemical synthesis of analytical standards. The method was used to identify the major AHL compound produced by the rhizosphere bacterium Acidovorax sp. N35 as N-(3-hydroxydecanoyl)homoserine lactone.

4-Butyrolactone↗

Superoxide dismutase biosensors working in non-aqueous solvent.

Enzymatic electrodes based on superoxide dismutase enzyme were developed. Using the superoxide dismutase enzyme sensor assembled according to the classical model, poor results were obtained. Results were improved by adopting a new way of assembling the biosensor using a cellulose triacetate layer in which the SOD enzyme is entrapped and sandwiched between two gas-permeable membranes, or using a kappa-carrageenan gel layer entrapping the enzyme, sandwiched between an external gas permeable membrane and an internal cellulose acetate membrane, coupled in each case to the oxygen amperometric transducer. Results obtained by applying the newly developed biosensor to assaying hydrophobic compounds showing radical scavenging properties, operating in dimethylsulfoxide, were also satisfactory.

Biosensing Techniques↗

Influences of non-selective interactions of nucleic acids on response rates of nucleic acid fiber optic biosensors.

The immobilization of oligonucleotides to solid surfaces can provide a platform of chemistry that is suitable for the development of biosensor and microarray technologies. Experiments were performed using a fiber optic nucleic acid biosensor based on total internal reflection fluorescence to examine the effects of the presence of non-complementary DNA on the detection of hybridization of complementary target DNA. The work has focused on the rates and extent of hybridization in the presence and absence of non-selective adsorption using fluorescein-labeled DNA. A stop-flow system of 137 microL volume permitted rapid introduction and mixing of each sample. Response times measured were on the order of seconds to minutes. Non-selective adsorption of non-complementary oligonucleotides (ncDNA) was found to occur at a significantly faster rate than hybridization of complementary oligomers (cDNA) in all cases. The presence of ncDNA oligonucleotides did not inhibit selective interactions between immobilized DNA and cDNA in solution. The presence of high concentrations of non-complementary genomic DNA had little effect on the extent of hybridization of complementary oligonucleotides, but actually reduced the response times of sensors to cDNA oligonucleotides.

Biosensing Techniques↗

Electron-transfer mechanisms in amperometric biosensors.

The function of amperometric biosensors is related to electron-transfer processes between the active site of an (immobilized) enzyme and an electrode surface which is poised to an appropriate working potential. Problems and specific features of architectures for amperometric biosensors using different electron-transfer pathways such as mediated electron transfer, electron-hopping in redox polymers, electron transfer using mediator-modified enzymes and carbon-paste electrodes, direct electron transfer by means of self-assembled monolayers or via conducting-polymer chains are discussed.

Animals↗

Amperometric biosensor based on D-aminoacid oxidase for the R-perindopril assay.

A new amperometric biosensor based on D-aminoacid oxidase is described for the assay of R-perindopril. R-perindopril can be determined in the 400-20 nmol/L concentration range; the detection limit is 10 nmol/L. The selectivity was checked with S-perindopril, D- and L-proline, and polyvinylpyrrolidone. The main interfering species was D-proline. An automated system for the assay of R-perindopril based on the concept of flow injection with an amperometric biosensor (based on D-aminoacid oxidase) as detector is also described. The system is suitable for the on-line monitoring of R-perindopril at a sampling rate of 72 samples/h, in the linear range: 100 nmol/L -20 nmol/L with an RSD better than 0.09% (n = 10).

Angiotensin-Converting Enzyme Inhibitors↗

Characterization of wastewater toxicity by means of a whole-cell bacterial biosensor, using Pseudomonas putida, in conjunction with chemical analysis.

A new amperometric biosensor based on inhibition of Pseudomonas putida has been developed to assess the acute toxicity of wastewater. This system uses the biological component immobilized on disposable screen-printed electrodes. The responses for a selected group of polar organic standard substances were studied using Pseudomonas putida as biological component. The results have been compared with responses obtained using the same system and Escherichia coli as biological component and with the bioluminescence inhibition of Vibrio fisheri using ToxAlert 100. Different properties, e.g. the standard deviation (SD) of the data, the goodness of fit (R2) and the standard deviation (Syx) of the vertical distances of the points from the inhibition curve, the 50% effective concentration (EC50) and the toxicity units (TII50) of the standard substance, were calculated and compared. This biosensor was used to assess the acute toxicity of real wastewater samples collected at different wastewater treatment plants (WWTP). Finally, a sequential solid-phase extraction (SSPE) procedure followed by liquid chromatography-mass spectrometry (LC-MS) was used to determine the polar organic toxic substances present in the wastewater samples.

Biosensing Techniques↗

Determination of salicylate in beverages and cosmetics by use of an amperometric biosensor.

A fast and selective enzymatic method for the determination of salicylate in beverages and cosmetics has been developed. The enzyme salicylate hydroxylase was immobilised covalently onto a glassy carbon working electrode of a wall-jet cell coupled with a flow-injection analysis system. The salicylate is enzymatically converted to catechol, which can be detected amperometrically on the glassy carbon electrode at +0.45 V. The response of the biosensor is linearly proportional to the concentration of salicylate between 725 nmol/l and 700 micromol/l. A high sample throughput (60 h(-1)) is possible, and the biosensor is stable for more than three months. Sample pretreatment for beverages and hair lotions is easy and fast. For creams, an extraction of salicylate is necessary. Relative standard deviations are less than 5.5% and the recoveries are between 95 and 105%.

Journal Article↗

Development of a biosensor for on-line detection of tributyltin with a recombinant bioluminescent Escherichia coli strain.

A biosensor was developed for the detection of tributyltin (TBT), using a bioluminescent recombinant Escherichia coli:: luxAB strain. Dedicated devices allowed the on-line measurement of bioluminescence, pH and dissolved oxygen values and the feed-back regulation of temperature. Bacterial physiology was monitored by the measurement of the cellular density, respiratory activity and the intracellular level of ATP, glucose and acetate levels. Our results showed that a synthetic glucose medium gave a better TBT detection limit than LB medium (respectively 0.02 micro M and 1.5 micro M TBT). High growth and dilution rates ( D=0.9 h(-1)) allowed maximum light emission from the bacterium. Moreover, simple atmospheric air bubbling was sufficient to provide oxygen for growth and the bioluminescence reaction. Real-time monitoring of bioluminescence after TBT induction occurred with continuous addition of decanal up to 300 micro M, which was not toxic throughout a 7-day experiment. The design of our biosensor and the optimization of the main parameters that influence microbial activity led to the capacity for the detection of TBT.

Biosensing Techniques↗

An Escherichia coli biosensor capable of detecting both genotoxic and oxidative damage.

A two-plasmid dual reporter Escherichia coli biosensor was developed using the genes for bacterial bioluminescence and a mutant of the green fluorescent protein, GFPuv4. To achieve this, the two plasmids, which were derivatives of pBR322 and pACYC184, had compatible origins of replication and different antibiotic selection markers: ampicillin and tetracycline. The parent strains DK1 and ACRG43, each carrying a single plasmid with one of the fusion genes (strain DK1 harboring a fusion of the katG promoter to the lux operon while in ACRG43, the recA promoter was fused with the GFP gene), were responsive to oxidative and DNA damage, respectively, resulting in higher bioluminescence or fluorescence under the relevant toxic conditions. The responses of the dual sensor strain, DUAL22, to various toxicants, e.g., mitomycin C, N-methyl-N-nitro--nitrosoguanidine, hydrogen peroxide and cadmium chloride, were characterized and compared with the responses of the parent strains to the same chemicals. Finally, several chemical mixtures that cause various stress responses were tested to demonstrate the ability of this biosensor to detect specific stress responses within a multiple toxicity environment.

Artificial Gene Fusion↗

A screen-printed biosensor using pyruvate oxidase for rapid determination of phosphate in synthetic wastewater.

A screen-printed phosphate biosensor based on immobilized pyruvate oxidase (PyOD, E.C. 1.2.3.3) has been developed for monitoring phosphate concentrations in a sequencing batch reactor (SBR) system. The enzyme was immobilized by a nafion matrix and covered a poly(carbamoyl) sulfonate (PCS) hydrogel on a screen-printed electrode. PyOD consumes phosphate in the presence of pyruvate and oxygen and generates hydrogen peroxide (H2O2), carbon dioxide and acetylphosphate. The electroactive H2O2, monitored at +420 mV vs Ag/AgCl, is generated in proportion to the concentration of phosphate. The sensor has a fast response time (2 s) and a short recovery period (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 microM to 625 microM phosphate with a detection limit of 3.6 microM. There was good agreement (R2=0.9848) between the commercial phosphate testing kit and the phosphate sensor in measurements of synthetic wastewater in a SBR system. This sensor maintained a high working stability (>85%) after 12 h of operation and involved a simple operation procedure. It therefore serves as a useful tool for rapid and accurate phosphate measurements in the SBR system and probably for process control.

Bioreactors↗

Whole-cell living biosensors--are they ready for environmental application?

Since the development of the first whole-cell living biosensor or bioreporter about 15 years ago, construction and testing of new genetically modified microorganisms for environmental sensing and reporting has proceeded at an ever increasing rate. One and a half decades appear as a reasonable time span for a new technology to reach the maturity needed for application and commercial success. It seems, however, that the research into cellular biosensors is still mostly in a proof-of-principle or demonstration phase and not close to extensive or commercial use outside of academia. In this review, we consider the motivations for bioreporter developments and discuss the suitability of extant bioreporters for the proposed applications to stimulate complementary research and to help researchers to develop realistic objectives. This includes the identification of some popular misconceptions about the qualities and shortcomings of bioreporters.

Bacteria↗

Microbial and cytoplasmic membrane-based potentiometric biosensors for direct determination of organophosphorus insecticides.

Potentiometric biosensors for the determination of organophosphorus (OP) insecticides were developed by applying either immobilized whole cells or cytoplasmic membrane fractions of wild-type Flavobacterium sp. on the surface of a glass pH electrode. The ability of Flavobacterium sp. to degrade OP compounds as sole carbon source was demonstrated for parathion with a degradation rate of almost 100% after 30 min and for chlorpyrifos of 33% after 48 h incubation. The products of hydrolysis of these compounds, p-nitrophenol and 3,5,6-trichloro-2-pyridinol, were accumulated in the medium and not used as substrates for growth by Flavobacterium sp. In the course of hydrolysis, which is catalyzed by organophosphorus hydrolase, two protons are released for each substrate molecule hydrolyzed. This stoichiometry forms the electrochemical basis of the potentiometric biosensors. Direct determination without previous extraction of OP was carried out in a stirred measuring cell with a pH electrode as transducer. Poly(carbamoyl sulfonate) (PCS) prepolymer, a hydrogel with good adhesive properties, was used for immobilization of whole cells and membrane-associated organophosphorus hydrolase. The sensor with cytoplasmic membrane fractions was superior to the one with whole cells and showed a linear range for paraoxon from 0.01 to 0.47 mM and 3 weeks' working stability.

Aryldialkylphosphatase↗