PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Materials Testing”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Proficiency testing of platelet counting in Ontario.

Proficiency testing results provide data for interlaboratory comparisons. The Laboratory Proficiency Testing Program of Ontario, Canada, has tested platelet counting for a decade and other hematology parameters for 15 years. Despite the fact that all testing programs are compromised by the type of testing material used, for platelet count testing, conclusions are possible. The data indicate that most laboratories in Ontario have greater difficulty performing reproducible platelet counting as compared with other components of hematologic cytometry. A major contributor to this shortfall is the method used by the laboratory. It was not a surprise that manual counting had a high coefficient of variation. Unexpectedly, the semiautomated methods used in the mid-1980s also displayed a high coefficient of variation.

Humans↗

Split depression tibial plateau fractures: a biomechanical study.

OBJECTIVE: To determine the biomechanical characteristics of four different fixation constructs for split depression fractures of the lateral tibial plateau (OTA classification 41B3.1). DESIGN: Laboratory investigation using a cadaveric simulated split depression tibial plateau fracture model. SETTING: Split depression tibial plateau fractures were created, reduced, and instrumented in a matched pair design. Specimens were tested for stiffness using a materials testing machine. INTERVENTION: Tibias were instrumented with an L-buttress plate, four 3.5-millimeter subchondral raft screws with an antiglide plate, an L-buttress plate with cancellous allograft, or four 3.5-millimeter subchondral raft screws placed through a periarticular plate. MAIN OUTCOME MEASUREMENTS: Vertical subsidence of the lateral tibial plateau was measured for the entire construct and for the local depression. The relative medial and lateral condylar tilt with central loading was also measured. RESULTS: There was no significant difference between the four fixation methods for overall longitudinal stiffness of the proximal tibial fracture fixation construct (range, 2,026 to 2,666 newtons per millimeter). The local depression stiffness for the raft-periarticular plate and raft-antiglide plate were 425 newtons per millimeter and 342 newtons per millimeter, respectively, versus 243 newtons per millimeter and 210 newtons per millimeter for the two large fragment buttress constructs. There was no significant difference between the local depression stiffness for the two raft constructs. There was no significant difference between the local depression stiffness for the two buttress plate constructs. Local depression stiffness was found to be significantly greater for the raft-periarticular plate construct when compared with the large fragment buttress plate construct without bone graft (p = 0.0314). Condylar tilt data showed a significant difference between the medial tilt observed in the prefracture specimen and the lateral tilt observed after fixation (p less-than-or-equal 0.017) for all constructs. CONCLUSIONS: There was no significant difference in the overall construct stiffness between the four fixation constructs. Fixation constructs with a raft of subchondral screws were more resistant to local depression loads. This supports the use of a raft construct when a central depression is a significant component of the overall fracture pattern. Condylar tilt data showed a persistent weakness in the postfixation lateral plateau regardless of fixation construct when compared with the intact specimen. This supports the current clinical practice of delayed weight-bearing for ten to twelve weeks.

Biomechanical Phenomena↗

The biomechanical effects of spondylolysis and its treatment.

STUDY DESIGN: Biomechanical analysis of the level above pars defects was performed using calf lumbar spines. OBJECTIVES: To evaluate whether complete spondylolysis contributes to the pathology of the upper adjacent motion segment to the pars defect. SUMMARY OF BACKGROUND DATA: It is well recognized that patients with spondylolysis show a higher incidence of spondylolisthesis or degenerative disc changes at the level of the pars defects. However, some authors have referred to the fact that disc damage may occur at the level above the defect and give rise to symptoms. However, no previous studies have been directed to the kinematic influence on the upper adjacent segment to pars defects. METHODS: Nine fresh-frozen calf lumbar spines were used for this study. The bony defects were created on the L4 pars articularis bilaterally. Three linear extensometers and one specially designed angular extensometer were mounted across the L3-L4 and L4-L5 motion units. Nondestructive static loads, including axial compression, flexion-extension, and axial rotation, were applied on the specimens in four different conditions as follows: 1) intact spine; 2) bilateral pars defects on the L4 laminae; 3) pars defect repair with Buck technique; and 4) pedicle screw-rod fixation at L4-L5 after removal of the interarticular screws. Testing was performed on a material testing machine (MTS 858 Bionix test system, Minneapolis, MN), and load-displacement curves were recorded with the extensometers. Each test was performed for over five full sinusoidal loading cycles, and data from the fifth cycle were collected and analyzed. RESULTS: After creating the pars interarticularis defects at L4, mobility at both the L3-L4 and L4-L5 motion units were increased in all loading conditions. The normalized range of motion (% ROM) as compared with the intact specimens showed that the pars defects increased the mobility at the upper adjacent level (L3-L4) to 106.4% in flexion-extension and to 120.1% in axial rotation; the differences were significant (P < 0.01). Consequently, the increased mobility was stabilized by applying Buck screws through the defects on both sides; however, the effect was not statistically significant. Furthermore, pedicle screw-rod fixation applied at the L4-L5 segment increased the intervertebral motion at the upper adjacent level, and % ROM in axial rotation was significantly increased to 119.2% of the intact spine (P < 0.05). Comparing the treatments' effects on the L3-L4 segment and that on L4-L5, the Buck screws restored the stability of both segments to the level of the intact spine, whereas the pedicle screw system limited the motion of L4-L5 motion and, on the contrary, increased the L3-L4 motion. CONCLUSIONS: This biomechanical study exhibited that bilateral pars interarticularis defects increased the intervertebral mobility, not only at the involved level but also at the upper adjacent level to the lysis. The increased mobility at the upper segment was reduced by the Buck screw technique. However, this was increased again by the pedicle screw system applied on the involved segment. If clinically applicable, fixation of the pars defect alone appears to cause less adjacent level mechanical stress than pedicle screw-rod motion segment fixation.

Animals↗

Photopatch testing: a consensus methodology for Europe.

A group of interested European Contact Dermatologists/Photobiologists met to produce a consensus statement on methodology, test materials and interpretation of photopatch testing. While it is recognized that a range of local variables operate throughout Europe, the underlying purpose of the work is to act as an essential preamble to a Pan European Photopatch Test Study focusing particularly on sunscreen chemicals.

Dermatitis, Photoallergic↗

Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque.

The purpose of this study was to determine whether bone mineral density of the host bone, measured using conventional dual photon absorptiometry techniques, and insertion torque can predict part of the ultimate failure strength of interference screw fixation of quadrupled hamstring tendon grafts. The semitendinosus and gracilis tendons were harvested from 10 human cadaveric knees, mean age 66.5 years (range, 53 to 81). The bone tunnel was sized within 0.5 mm of the graft. The graft was fixed with a biodegradable screw (7 x 25 mm for the femur, and 9 x 25 mm for the tibia) directly against the tendon and at the joint surfaces. Tibial fixation and femoral fixation were tested to failure using a materials testing system. Bone mineral density was measured in the metaphyseal region of the tibia and femur. The results of multiple regression analyses showed that both insertion torque and bone mineral density were related to the maximum load the graft withstood. These two variables explained 77.1% of the maximum load observed. We concluded that bone mineral density measurements of the host bone site are an important determinant of postoperative graft strength and thus have an important, but previously unrecognized, clinical role in establishing individual postsurgery rehabilitation protocols. Insertion torque in this study was a useful predictor of graft fixation strength.

Aged↗

Effects of braiding on tensile properties of four-strand human hamstring tendon grafts.

BACKGROUND: Anterior cruciate ligament reconstruction is commonly performed with autogenous hamstring tendon grafts. PURPOSE: To ascertain the effects of braiding on ultimate tensile strength and stiffness of hamstring tendon graft. STUDY DESIGN: Controlled laboratory study. METHODS: Sixteen fresh-frozen semitendinosus and gracilis tendons were harvested from eight matched (right and left) human cadaveric specimens. Both sets of hamstring tendons from each matched pair were doubled, creating a four-strand graft. Grafts were then randomized so that one graft from each matched pair was braided and the other remained unbraided. The diameter of each graft construct was recorded. Grafts were tested to failure on a materials testing machine. RESULTS: There were no significant differences in cross-sectional area before or after braiding. Fifteen of 16 tendons failed midsubstance; 1 failed at the lower clamp. Braiding reduced the initial tensile strength and stiffness of human hamstring tendon grafts in this study by 35.0% and 45.8%, respectively. CONCLUSIONS: Braiding may place the collagen fibers in a suboptimal orientation for loading that results in a weaker graft. We do not recommend the use of braiding if the strongest, stiffest initial graft is desired.

Aged↗

Full-thickness rotator cuff tears. A biomechanical comparison of suture versus bone anchor techniques.

We performed a biomechanical comparison of two rotator cuff repair techniques using fresh-frozen human cadavers. Nine pairs of cadaveric shoulders had standardized full-thickness tears made at the supraspinatus tendon insertion. One of each pair of the cadaveric shoulders was repaired by pulling the tendon into a bone trough in the humeral head using standard sutures. The remaining half of the pairs was repaired using anchor sutures. The repairs were tested using a servohydraulically operated material testing system. The anchor suture repair was significantly stronger than the standard suture technique irrespective of bone quality. Failure occurred predominantly through bone in the suture repairs and as a result of suture breakage in the anchor repairs. The anchors should be placed into the edge of the subchondral bone adjacent to the articular surface. The surgeon should direct the anchor so that the direction of the pull is approximately 90 degrees to the anchor, with the humerus at 30 degrees of abduction.

Aged↗

Arthrodesis of the first metatarsophalangeal joint: a biomechanical study of internal fixation techniques.

This study compares the strength and rigidity of four methods of internal fixation for arthrodesis of the first metatarsophalangeal joint. Ten matched pairs of cadaveric first rays were harvested and arthrodesis performed by one of four techniques: (1) planar excision of joint surfaces and fixation with crossed Kirschner wires, (2) planar excision of joint surfaces and internal fixation with a dorsal plate and screws, (3) planar excision of joint surfaces and internal fixation with an interfragmentary screw, or (4) excision of the joint surfaces using powered conical reamers and fixation with an interfragmentary lag screw. Biomechanical testing with a Bionix 858 materials testing machine was carried out, applying a plantar force utilizing principles of cantilever loading. Force applied and displacement of the arthrodesis were recorded. Of the four methods tested, bony preparation with power conical reamers and supplementary interfragmentary screw fixation was the most stable.

Arthrodesis↗

An in vitro assessment of tissue compression damage during circular stapler approximation tests, measuring expulsion of intracellular fluid and force.

Circular staplers are among the many instruments used during minimally invasive or open surgery that should approximate soft tissue within safe compression limits. Previous in vivo suture-line blood flow measurement has suggested a safe thickness reduction limit of 25 per cent during circular stapling procedures. The present work investigates in vitro assessment of the maximum safe compression of large and small porcine intestines, measuring the required compressive force and the expelled intracellular fluid (measured as a potassium solution). A test-rig mounted on a materials testing machine allowed staplers of three sizes to compress tissue samples to thicknesses ranging from 90 to 45 per cent of original thickness. The expelled fluid was collected in 40 ml of 0.9 per cent NaCl and analysed in a flame photometer. The force measurements indicated that the small intestinal tissue samples underwent a sharp increase in stiffness over a strain range of 0.19-0.34. The large bowel tissue underwent a similar increase in stiffness over a planar compressive strain range of 0.19-0.40. The regularity of the potassium output results was limited, making it difficult to draw firm conclusions, although there was some indication that the potassium output from small intestinal tissue may change from erratic to approximately linear at a strain of approximately 0.19, while that of the large bowel tissue appeared to be approximately linear over the entire strain range tested. From the force measurements, it is concluded that strain-induced structural change may help provide a useful definition of safe tissue approximation. The possible implications for reduced dehiscence (wound disintegration) and stricture incidence in stapled anastomoses are discussed.

Animals↗

[Intra- and interindividual differences in tensile strength of human bone].

UNLABELLED: In a biomechanical study we evaluated the stability of human femurs. In order to document the inter- and intraindividual differences in bending stability, we tested 200 bone samples, harvested from the femurs of 5 multiorgan donors. The bending tests were performed on a material testing machine (ZWICK) under standardized conditions. Our results revealed significant differences in the stability of the femurs of the 5 multiorgan donors. Furthermore, there was a significant difference in breaking strength at different levels of the same bone. CLINICAL RELEVANCE: In studies aimed at evaluating the primary bony stability of alloimplants after different preservation or sterilization procedures, the above-mentioned results should be taken into consideration.

Adult↗

[High resolution and spirometric synchronization computerized tomography in chronic obstructive bronchopneumopathy].

PURPOSE: To assess the feasibility of spirometrically gated HRCT in patients with chronic obstructive pulmonary disease and to correlate the density measures with the results of pulmonary function tests. MATERIAL AND METHODS: Pulmonary function tests and spirometrically gated HRCT were performed, on the same day, in 20 patients with chronic obstructive pulmonary disease. Spirometrically gated HRCT scans at 90 and 10% of the patient's vital capacity were acquired, at three anatomical levels (carena, carena plus 5 cm, carena minus 5 cm). In each section, lung parenchyma was isolated from the other thoracic structures and from the main bronchi and a densitometric evaluation was applied to the regions of interest. A histogram showing the distribution of the pixel frequencies versus lung densities, the mean CT number and the pixel index at -910 HU (for scans acquired at 10% of the patient's vital capacity) and at -950 HU (for scans obtained at 90% of the patient's vital capacity) were obtained. Average acquisition time for the spirometrically gated HRCt was 15-20 minutes, average data processing time was 20 minutes. RESULTS: The mean CT number and the pixel index at -910 HU obtained at 10% of the patient's vital capacity correlated with the Tiffeneau index (r = 0.85; R = 0.78 respectively). The pixel index at -910 HU correlated also with the ratio of residual volume to total lung capacity (r = 0.65). The mean CT number and the pixel index obtained at 90% of the vital capacity correlated with the lung diffusion of carbon monoxide (r = 0.64 and r = 0.79 respectively). CONCLUSIONS: In our study, we found good correlation between the densitometric values obtained with spirometrically gated HRCT and the respiratory function tests routinely employed to assess the presence and the gravity of obstructive pulmonary disease. A good reproducibility of the data is guaranteed by the spirometical gating which enables standardization of the lung acquisition volume, and by the semiautomatic contour tracing program combined with an automated densitometric evaluation. The main disadvantages of the technique are the relatively long acquisition and evaluation times. Spirometrically gated HRCT densitometry is a promising tool for longitudinal studies of diffuse lung disease (pulmonary emphysema and fibrosis).

Adult↗

Microimmunodiffusion test for diagnosis of ovine progressive pneumonia.

Two microimmunodiffusion tests (MIDT) for detection and measurement of ovine progressive pneumonia antibody are described. Substrates of various salt concentrations and pH were used to determine the optimal conditions for the tests. In comparisons between two MIDT and one macroimmunodiffusion test, sera from cull ewes were used. The MIDT require less reagents and were more responsive than the macroimmunodiffusion test. After extended incubation of the test materials, results in all three tests were comparable.

Animals↗

[Examination of the water supply with the alkali and alkali-earth supplement optimized DIN luminescent bacteria test, exemplified by the Saar river].

The light intensity emitted by luminescent bacteria is influenced by both the osmolarity and the ion composition of the test medium. The addition of potassium and calcium ions to a sodium chloride solution causes a considerable increase in the light intensity of bacteria. If these elements occur in the proper concentrations in the test material, the luminescence in the test sample will be higher than in the control sample containing only sodium chloride. This physiological dependence did not find the due consideration in the establishment of the German standard method for the luminescent bacteria test using Microtox bacteria (German Institute for Standardization DIN 38,412, Part 34--edition March 1991) where only the osmotic balancing by sodium chloride was taken into account. For testing chemicals, the luminescent bacteria test with Microtox reagent can be run without problems by the procedure that is recommended by Microbics Corporation and which became part of the DIN standard method. The situation is different when analyses of natural waters or effluents from wastewater plants are concerned, where matrix effects have to be expected. Stimulation of light intensity can be a reflection of a nonoptimized test medium and in the worst case may cause false negative results. The new ASW (artificial sea-water) luminescent bacteria medium according to Klein, which besides sodium contains potassium, magnesium, and calcium ions, brings stimulation to both samples and controls, effectively reducing enhancement and increasing the inhibitory effects of samples from the River Saar. However, high light stimulation rates measured in parallel tests with the DIN procedure could not be caused by the low concentrations of alkaline and alkaline-earth ions in the samples. The experiments indicate that there must be additional influencing substances which have not yet been identified. Furthermore, the experiments show that the matrix effects of unknown origin that will exert a positive influence on the light emission may be compensated by addition of alkaline and alkaline-earth ions.

Animals↗

Basic hearing tests.

This article contains a discussion of pure-tone and speech audiometry as these measures relate to primary audiologic evaluation of hearing. The scientific foundation underlying the development of stimulus-specific standards for normal hearing, test materials, and methods for basic tests are included. A rationale for test administration, masking, and interpretation of results is presented.

Audiometry, Pure-Tone↗

[The significance of postoperative stability for osseous repair of a multiple fragment fracture. Animal experiment studies].

The significance of postoperative mechanical stability for bony repair of a comminuted fracture was investigated in an animal experimental study comparing four commonly applied operative methods of stabilizing fractures: (1) flate osteosynthesis combined with lag screw fixation after reduction of the fragments; (2) bridging plate osteosynthesis; (3) external fixation; (4) static interlocking intramedullary nailing. As the fracture model, a triple-wedge osteotomy of the right sheep tibia was used. The results of in vitro testing of stiffness (N/mm) of each of the four osteosyntheses was as follows: anatomical plate: 746 N/mm; bridging plate 434 N/mm; external fixation 625 N/mm; nailing 416 N/mm. Eight weeks after the operation, the tibiae were explanted and the contralateral tibiae of six sheep were taken as a control group. The three-point bending test revealed no significant difference in bending deviation: anatomical plate 47.58 +/- 22.57 microns; bridging plate 33.93 +/- 7.67 microns; external fixation 33.83 +/- 8.02 microns; nailing 33.0 +/- 17.23 microns. However, it was noted that there was a slightly higher tendency towards stiffness of the bones after bridging plate osteosynthesis, external fixation and interlocking intramedullary nailing and that the amount of stiffness resembled that in non-operated control animals (25.56 +/- 6.66 microns). On the other hand, anatomical plate osteosynthesis showed less stiffness. To assess the tensile strength at the osteotomy area, bone samples were prepared and tested for failure on a material testing machine. The tensile strength of the bone samples showed a distinct difference in all experimental groups according to their anatomical location.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

[Computerized tests of attention, memory and motor performance applied to geriatric research].

The purpose of this paper is to present certain psychological tests adapted for computerized testing of subjects. The reasons why we have considered such tests are numerous: computerized test facilitate measurement of reaction time, testing conditions are standardized without reliance on performance of research assistants, data can be recorded on disc storage without paper handling, preliminary analyses and individual results can be available immediately after testing, simulation of certain real-life situations is possible, randomization of testing materials is facilitated. The computerized testing paradigms for use in gerontology to be discussed are: one an attention task of possible use in psychological research; the second a memory task aimed at basic cognitive psychological research and finally a performance task relating to a complex motor ability (flying). All provide inexpensive, reliable, quantified data and all use the same hardware. It is expected that this area will expand enormously and rapidly.

Aged↗

Stability of external fixators used for knee arthrodesis after failed knee arthroplasty.

Secondary arthrodesis as treatment for failed knee arthroplasty is being used increasingly. The usual method is sustained rigid external fixation. The fusion rate is low in cases with considerable metaphyseal bone loss and poor bone quality. Currently, the Hoffmann- Vidal fixator or comparable designs are preferred to the less stable Charnley single frame fixator. The standard Hoffmann- Vidal device uses only transverse percutaneous fixating pins and gives an anteroposterior bending stiffness that is considerably lower than the lateral bending stiffness. In the present study, external fixators were tested for stability in a material testing machine under standardized conditions using synthetic bones. The anteroposterior bending stiffness was significantly improved when sagittal pins connected to a ventral compression rod were added to a Hoffmann- Vidal fixator. Stiffness was still more improved when sagittal pins were connected to ventral frames as in a modification of the Hoffmann- Vidal or the similar Ace-Fischer fixator.

Arthrodesis↗

The relative rate of wound healing in longitudinal and transverse laparotomy incisions. Animal experiments.

The wound healing of longitudinal and transverse laparotomy incisions was investigated in rabbits. The longitudinal incision was made in the linea alba cranially and caudally to the umbilicus, and the transverse at the level of the umbilicus. The mechanical testing was performed with a materials testing machine (Alvetron). In order to eliminate the influence on the different incisions of different forces acting upon them the mechanical characteristics of the wounds were expressed in per cent of those from the intact tissues. The measurements of the relative energy absorption displayed no significant difference between healing transverse (comprising rectus muscle) and longitudinal incision wounds. When the rectus wound is excluded, the transverse incision was more resistant to rupture than the longitudinal during the 28 days of wound healing studied. A comparison between the present results and those from investigations of holding power of tissues against suture shows, that the transverse incision should be preferred to the linea alba incision.

Animals↗