At least 919 records · Page 51Linked to original sources

Integrated sample preparation and MALDI mass spectrometry on a microfluidic compact disk.

High-throughput microfluidic processing of protein digests integrated with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry on a compact disk (CD) is described. Centrifugal force moves liquid through multiple microstructures, each containing a 10-nL reversed-phase chromatography column. The CD enables parallel preparation of 96 samples with volumes ranging from one to several microliters. The peptides in the digests are concentrated, desalted, and subsequently eluted from the columns directly into MALDI target areas (200 x 400 microm) on the CD using a solvent containing the MALDI matrix. After crystallization, the CD is inserted into the MALDI instrument for peptide mass fingerprinting and database identification at a routine sensitivity down to the 200-amol level. Detection of proteolytic peptides down to the 50-amol level is demonstrated. The success rate of the CD technology in protein identification is about twice that of the C(18) ZipTips and standard MALDI steel targets. The CDs are operated using robotics to transfer samples and reagents from microcontainers to the processing inlets on the disposable CD and spinning to control the movement of liquid through the microstructures.

Journal Article↗

A dry process for production of microfluidic devices based on the lamination of laser-printed polyester films.

A new microfabrication process based on a xerographic process is described. A laser printer is used to selectively deposit toner on a polyester film, which is subsequently laminated against another polyester film. The toner layer binds the two polyester films and allows the blank regions to become channels for microfluidics. These software-outlined channels are approximately 6 microm deep. Approximately twice this depth is obtained by laminating two printed films. The resulting devices were not significantly damaged after 24 h of exposure to aqueous solutions of H3PO4, NaOH, methanol, acetonitrile, or sodium dodecyl sulfate. Electric tests with an impedance analyzer and microchannels filled with KCl solution demonstrated that (1) wide channels suffer from deformation of the top and bottom walls due to the lamination of the polyester films and (2) the toner walls are somewhat porous. Although these drawbacks limit the maximum width of a channel and the minimum distance between two channels, the process is an attractive option to other expensive, laborious, and time-consuming methods for microchannels fabrication. The process has been used to implement devices for electrospray tip and capillary electrophoresis with contactless conductivity detection.

Journal Article↗

An integrated microfluidic system for reaction, high-sensitivity detection, and sorting of fluorescent cells and particles.

Presented is a novel approach for an integrated micro total analysis system (microTAS) based on a microfluidic on-chip device that supports ultrasensitive confocal detection of fluorescent cells and particles and subsequently allows for their precise sorting in the fluid phase with respect to spectroscopic properties, such as brightness and color. The hybrid silicone elastomer/glass chip first comprises a branched channel system to initiate fluid mixing and to hydrodynamically focus the sample solution down to a thin flow layer, matching the size of the confocal detection volume placed at that position and, thus, providing a high detection efficiency. In the subsequent on-chip module, the dispersed cells or particles can be sorted into two different output channels. The sorting process is realized by a perpendicular deflection stream that can be switched electrokinetically. The performance of the automated sorting routine is demonstrated by precise partition of a mixture of differently colored fluorescent beads. Moreover, the specifically branched channel geometry allows for direct implementation of reaction steps prior to detection and sorting, which is demonstrated by inducing a selective recognition reaction between the fluorescent protein R-phycoerythrin and a mixture of live bacterial cells exhibiting or lacking the respective surface antigens.

Journal Article↗

Fabrication of patterned multicomponent protein gradients and gradient arrays using microfluidic depletion.

We demonstrate that depletion effects in the fluids used to fill a poly(dimethylsiloxane) microfluidic device can be used in conjunction with its design rules to generate patterned protein gradients. The linear portions of these structures can be designed to present gradients of bound protein coverage-varying from near-saturation to effectively zero-over distances ranging from a few hundred micrometers to more than 1 cm by design. Such patterns can be developed in a simple, single-channel form as well as in a multichannel gradient array of more complex design. The patterning protocols also support the use of multiple protein sources, and we demonstrate an assembly process mediated by a protein that inhibits adsorption to generate a gradient array in pixel form. We describe examples of multiple protein gradient patterns along with simple immunoassays to illustrate the scope of the methodology, the activity of the patterned proteins, and their recognition in gradient form on a surface. These gradients should prove useful to studies in biosensor and bioassay development and as substrates for cell culture to study growth and motility.

Journal Article↗

Microfluidic chip for continuous monitoring of hormone secretion from live cells using an electrophoresis-based immunoassay.

A microfluidic device has been developed for the determination of insulin secreted from islets of Langerhans by a capillary electrophoresis competitive immunoassay. Online assays were performed by electrophoretically sampling anti-insulin antibody (Ab), fluorescein isothiocyanate-labeled insulin (FITC-insulin), and insulin from separate reservoirs and allowing them to mix as they traveled through a 4-cm reaction channel heated to 38 degrees C. From the reaction channel, samples were injected onto a 1.5-cm-long electrophoresis channel where the FITC-insulin and FITC-insulin-Ab complex were separated in 5 s using an electric field of 500 V/cm. Detection limits for insulin were 3 nM in this mode of operation. Assays could be collected at 15-s intervals with continuous sampling and online mixing for up to 30 min with no intervention. Relative standard deviation was 2-6% depending on the insulin concentration. Response time to a step change in insulin concentration was 30 s. For live cell monitoring, single islets were placed into a reservoir on the chip and fluid in the immediate vicinity was continuously sampled to detect insulin secretion from the islet. Monitoring of insulin secretion with electropherograms taken at 15-s intervals resolved secretory profiles characteristic of first- and second-phase insulin secretion. The method should be amenable to other cell or tissue types for measurements of release with high temporal resolution.

Animals↗

Fluid flow past an aperture in a microfluidic channel.

Electroosmotically driven flow in neurotransmitter-based retinal prostheses offers a novel approach to interfacing the nervous system. Here, we show that electroosmotically driven flow in a microfluidic channel can be used either to eject or to withdraw fluid through a small aperture in the channel wall. We study this fluid movement numerically using a finite-element method and experimentally using microfabricated channels and apertures. Two devices are used to test the concept of fluid ejection and withdrawal: (1) a single, large channel with four apertures and (2) a prototype neural interface with four individually addressable apertures. We compared experimental and numerical results in microchannels using the observed pH dependence of the fluorescent dye fluorescein, finding good agreement between the results. Because of the simplicity and rapid response of electroosmotic flow, this technique may be useful for neurotransmitter-based neural interfaces.

Journal Article↗

A microfluidics approach to the problem of creating separate solution environments accessible from macroscopic volumes.

We report on a microfluidic device that generates separate solution environments in macroscopic volumes. Spatially distinct patterns are created by emitting fluids from 16 different sources (closely spaced microchannels) into a solution-filled macroscopic chamber. The fluid in neighboring microchannels couples viscously in the macroscopic container, generating one single interdigitated stream. Scanning nanoelectrode amperometry was used for characterizing the concentration landscape and the diffusion zones between solutions running in parallel at different coordinates in the stream. These experiments were complemented by finite element simulations of the Navier-Stokes and mass transport equations to describe the velocity distributions and the diffusion behavior. For in channel flow velocities of 50 mm.s(-1), patterns could persist on the order of millimeters to centimeters in the open volume. The most narrow diffusion zones with widths less than 10 microm (5-95% concentration change) were found some tens of micrometers out in the macroscopic container. We demonstrate that a 14-microm-diameter nearly spherical object (biological cell) attached to a micropipet can be moved from one solution environment to another by a lateral displacement of only 8 microm. The device is suitable for applications where the solution environment around a microscopic or nanoscopic sensor needs to be changed multiple times, i.e., in order to build layered structures, for obtaining binding isotherms, and kinetic information, for example, on ion channels, enzymes, and receptors as well as in applications where different loci on an object need to be exposed to different environments or where complex solution environments need to be created for studies of interfacial chemistry between two streaming layers.

Journal Article↗

High-throughput nanoliter sample introduction microfluidic chip-based flow injection analysis system with gravity-driven flows.

In this work, a simple, robust, and automated microfluidic chip-based FIA system with gravity-driven flows and liquid-core waveguide (LCW) spectrometric detection was developed. The high-throughput sample introduction system was composed of a capillary sampling probe and an array of horizontally positioned microsample vials with a slot fabricated on the bottom of each vial. FI sample loading and injection were performed by linearly moving the array of vials filled alternately with 50-microL samples and carrier, allowing the probe inlet to enter the solutions in the vials through the slots sequentially and the sample and carrier solution to be introduced into the chip driven by gravity. The performance of the system was demonstrated using the complexation of o-phenanthroline with Fe(II) as a model reaction. A 20-mm-long Teflon AF 2400 capillary (50-microm i.d., 375-microm o.d.) was connected to the chip to function as a LCW detection flow cell with a cell volume of 40 nL and effective path length of 1.7 cm. Linear absorbance response was obtained in the range of 1.0-100 microM Fe(II) (r2=0.9967), and a good reproducibility of 0.6% RSD (n=18) was achieved. The sensitivity was comparable with that obtained using conventional FIA systems, which typically consume 10,000-fold more sample. The highest sampling throughput of 1000 h-1 was obtained by using injection times of 0.08 and 3.4 s for sample and carrier solution, respectively, with a sample consumption of only 0.6 nL for each cycle.

Journal Article↗

Isoelectric focusing in a poly(dimethylsiloxane) microfluidic chip.

This paper reports the application of ampholyte-based isoelectric focusing in poly(dimethylsiloxane) (PDMS) using methylcellulose (MC) to reduce electroosmosis and peak drift. Although the characteristics of PDMS make it possible to fabricate microfluidic chips using soft lithography, unstable electroosmotic flow (EOF) and cathodic drift are significant problems when this medium is used. This paper demonstrates that EOF is greatly reduced in PDMS by applying a dynamic coat of MC to the channel walls and that higher concentrations of MC can be used to increase the viscosity of the electrode solutions in order to suppress pH gradient drift and reduce "compression"of the pH gradient. To illustrate the effect of MC on performance, several fluorescent proteins were focused in microchip channels 5 microm deep by 300 microm wide by 2 cm long in 3-10 min using broad-range ampholytes at electric field strengths ranging from 25 to 100 V/cm.

Ampholyte Mixtures↗

Surface-directed, graft polymerization within microfluidic channels.

We demonstrate a simple procedure to coat the surfaces of enclosed PDMS microchannels by UV-mediated graft polymerization. In prior applications, only disassembled channels could be coated by this method. This limited the utility of the method to coatings that could easily and tightly seal with themselves. By preadsorbing a photoinitiator onto the surface of PDMS microchannels, the rate of polymer formation at the surface was greatly accelerated compared to that in solution. Thus, a gel did not form in the lumen of enclosed microchannels. We demonstrate that the photoinitiator benzophenone remained on the surface of PDMS even after extensive washing. After addition of a variety of monomer solutions (acrylic acid, poly(ethylene glycol) monomethoxyl acrylate, or poly(ethylene glycol) diacrylate) and illumination with UV light, a stable, covalently attached surface coating formed in the microchannels. The electroosmotic mobility was stable in response to air exposure and to repeated cycles of hydration-dehydration of the coating. These surfaces also supported the electrophoretic separation of two model analytes. Placement of an opaque mask over a portion of the channel permitted photopatterning of the microchannels with a resolution of approximately 100 microm. By using an appropriate mixture of monomers combined with masks, it should be possible to fabricate PDMS microfluidic devices with distinct surface properties in different regions or channels.

Journal Article↗

Microfluidic particle sorter employing flow splitting and recombining.

This paper describes an improved microfluidic device that enables hydrodynamic particle concentration and size-dependent separation to be carried out in a continuous manner. In our previous study, a method for hydrodynamic filtration and sorting of particles was proposed using a microchannel having multiple branch points and side channels, and it was applied for continuous concentration and separation of polymer particles and cells. In the current study, the efficiency of particle sorting was dramatically improved by geometrically splitting fluid flow from a main stream and recombining. With these operations, particles with diameters larger than a specific value move toward one sidewall in the mainstream. This control of particle positions is followed by the perfect particle alignment onto the sidewall, which increases the selectivity and recovery rates without using a liquid that does not contain particles. In this study, a microchannel having one inlet and five outlets was designed and fabricated. By simply introducing particle suspension into the device, concentrations of 2.1-3.0-microm particles were increased 60-80-fold, and they were collected independently from each outlet. In addition, it was demonstrated that the measured flow rates distributed into each side channel corresponded well to the theoretical values when regarding the microchannel network as a resistive circuit.

Journal Article↗

Laser-induced fluorescence detection system for microfluidic chips based on an orthogonal optical arrangement.

In this work, a simple LIF detection system based on an orthogonal optical arrangement for microfluidic chips was developed. Highly sensitive detection was achieved by detecting the fluorescence light emitted in the microchannel through the sidewall of the chip to reduce scattered light interference from the laser source. A special crossed-channel configuration, with a 1.5-mm distance from the separation channel to the sidewall of the glass chip, was designed in order to facilitate collection of emitted fluorescence light through the sidewall. The significant difference in intensity distribution of scattered laser light on the chip plane observed in this study was fully exploited to optimize S/N ratio of detected signals by rejection of scattered light, both through systematic measurements and employing ray-tracing simulation. A fluorescence collection angle of 45 degrees in the chip plane gave the best result, with a scattered light intensity 1/38 of that obtained at an angle of 90 degrees. Sodium fluorescein and fluorescein isothiocyanate-labeled amino acids were used as model samples to demonstrate the performance of the LIF system. A detection limit (S/N = 3) of 1.1 pM fluorescein was obtained, which is comparable to that of optimized confocal LIF systems for chip-based capillary electrophoresis. Apart from the high detection power, the system also has the advantages of simple optical structure, compactness, and ease in building.

Journal Article↗

Microfluidic sequential injection analysis in a short capillary.

An automated microfluidic sequential injection analysis system that efficiently manipulates sample and reagent solutions in the nanoliter range in approximately 10 s per analytical cycle is described. The system consisted of a 6-cm-long, typically 75-microm i.d., fused-silica capillary (which functioned as a sampling probe and reactor as well as a flow-through detection cell), a horizontally oriented waste reservoir that provided liquid level differences for inducing gravity-driven flows, an autosampling device holding samples and reagents with horizontally fixed slotted microvials, and a laser-induced fluorescence detection system. Sample and reagent zones were sequentially introduced via gravity-driven flow by scanning the capillary tip (functioning as the sampling probe) through the vial slots, while vials containing sample, reagent, and carrier were sequentially rotated to the probe by programmed movement of the vial holders. Sequentially injected nanoliter zones were rapidly mixed by convection and diffusion within the carrier flow, demonstrating a behavior that conformed well to the Taylor dispersion model, and zone penetration effects were characterized and optimized under Taylor's dispersion theory guidelines. For the determination of fluorescein, a high throughput of 400 h(-1) was achieved, rapidly producing calibration curves (five points) within 45 s. Owing to its adaptability to the Taylor's dispersion model, the system was used also for measuring diffusion coefficients of fluorescent species. Potentials for using the system in enzyme inhibition assays were demonstrated by a reaction involving the conversion of fluorescein digalactoside to fluorescent hydrolysates via beta-galactosidase and the inhibition of beta-galactosidase by diethylenetriaminepentaacetic acid.

Journal Article↗

Microfluidic and optical systems for the on-demand generation and manipulation of single femtoliter-volume aqueous droplets.

This paper describes a fluidic and optical platform for the generation and manipulation of single femtoliter-volume aqueous droplets. Individual droplets were generated on-demand using a microfluidic chamber that confers environmental flow stability. Optical vortex traps were implemented to manipulate and transport the generated droplets, which have a lower refractive index than the immiscible medium in which the droplets are immersed and thus cannot be trapped using conventional optical tweezers. We also demonstrated the ability to shrink and increase the refractive index of the generated droplet, thereby permitting its facile fusion with another droplet using an optical tweezer. To illustrate the versatility of this platform, we have performed both fast (<1 s) and slow (>1 h) chemical reactions in these femtoliter-volume aqueous droplets.

Journal Article↗

Voltammetric monitoring of transient hydrodynamic flow profiles in microfluidic flow cells.

We consider the transition to steady-state flow in the inlet region of a hydrodynamic channel cell and show that a microelectrode positioned within this inlet region allows chronoamperometric results to be recorded, from which information about the extent of the development of the flow profile may be deduced as well as information about the precise dimensions of the microfluidic channel.

Journal Article↗

Fabrication of plastic microfluid channels by imprinting methods.

Microfluidic devices have been fabricated on poly(methyl methacrylate) substrates by two independent imprinting techniques. First-generation devices were fabricated using a small-diameter wire to create an impression in plastics softened by low-temperature heating. The resulting devices are limited to only simple linear channel designs but are readily produced at low cost. Second-generation devices with more complex microchannel arrangements were fabricated by imprinting the plastic substrates using an inverse three-dimensional image of the device micromachined on a silicon wafer. This micromachined template may be used repeatedly to generate devices reproducibly. Fluorescent analtyes were used to demonstrate reproducible electrophoretic injections. An immunoassay was also performed in an imprinted device as a demonstration of future applications.

Indicators and Reagents↗

An integrated microfluidics-tandem mass spectrometry system for automated protein analysis.

We describe an integrated analytical system consisting of a microfluidics device micromachined using photolithography/etching technology, a panel of computer-controlled high-voltage relays, and an electrospray ionization tandem mass spectrometer. Movement of solvents and samples on the device and off the device to the mass spectrometer was achieved by directed electroosmotic pumping induced by the activation of a suitable constellation of high-voltage relays. The system was used for the sequential automated analysis of protein digests. We demonstrate low femtomole per microliter sensitivity of detection and compatibility of the system with the automated analysis of proteins separated by two-dimensional gel electrophoresis.

Amino Acid Sequence↗

Quantitative analysis of molecular interaction in a microfluidic channel: the T-sensor.

The T-sensor is a recently developed microfluidic chemical measurement device that exploits the low Reynolds number flow conditions in microfabricated channels. The interdiffusion and resulting chemical interaction of components from two or more input fluid streams can be monitored optically, allowing measurement of analyte concentrations on a continuous basis. In a simple form of T-sensor, the concentration of a target analyte is determined by measuring fluorescence intensity in a region where the analyte and a fluorescent indicator have interdiffused. An analytical model has been developed that predicts device behavior from the diffusion coefficients of the analyte, indicator, and analyte--indicator complex and from the kinetics of the complex formation. Diffusion coefficients depend on the local viscosity which, in turn, depends on local concentrations of all analytes. These relationships, as well as reaction equilibria, are often unknown. A rapid method for determining these unknown parameters by interpreting T-sensor experiments through the model is presented.

Kinetics↗