PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Silicon Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51Linked to original sources

Reducing the radiation dose during excretory urography: flat-panel silicon x-ray detector versus computed radiography.

OBJECTIVE: The purpose of the study was to examine the possibilities for reducing radiation exposure in uroradiology using digital flat-panel silicon X-ray detector radiography. We compared the subjectively determined image quality of abdominal radiographs and urograms obtained on a digital flat-panel detector radiography system with those obtained on a computed radiography system. SUBJECTS AND METHODS. Fifty patients who had a clinical indication for urography underwent unenhanced abdominal imaging that was alternately performed using flat-panel silicon X-ray detector radiography or computed radiography. For patients who required a second radiograph with contrast medium, the examination modality was changed to avoid exposing the patients to excess radiation. The images obtained on flat-panel X-ray detector radiography were obtained at half the radiation dose of the images obtained on computed radiography (800 speed vs 400 speed). The resulting 50 pairs of images were interpreted by four independent observers who rated the detectability of structures of bone and the efferent urinary tract relevant to diagnosis and compared the image quality. RESULTS: At half the radiation dose, digital flat-panel X-ray detector radiography provided equivalent image quality of the liver and spleen, lumbar vertebrae 2 and 5, pelvis, and psoas margin on abdominal radiographs. The image quality obtained with digital flat-panel X-ray detector radiography of the kidneys, the hollow cavities of the upper efferent urinary tract, and the urinary bladder was judged to be statistically better than those obtained with computed radiography. CONCLUSION: With half the exposure dose of computed radiography, the flat-panel X-ray detector produced urograms with an image quality equivalent to or better than computed radiography.

Diagnosis, Computer-Assisted↗

Effects of Si-functional isocyanate on the stability of oil-in-water emulsion with and without a carbon functional isocyanate.

The effects of silicon-functional isocyanates on the stability of oil-in-water emulsions with and without a carbon functional triisocyanate in the oil phase were investigated. The oil component was di-n-butyl-phthalate (DBP) containing Aerosol OT as an emulsifier. It was found that only CH3Si(NCO)3 among the (CH3)nSi(NCO)4 - n's was effective to contribute additional stability for the emulsion without a carbon functional triisocyanate. It was also found that a reaction product of CH3Si(NCO)3 with water reacted with a carbon functional triisocyanate.

Dibutyl Phthalate↗

Non-linear finite element analysis of the failure progression of fiber-reinforced ceramics produced by tape casting technique.

The purpose of this study was to investigate the failure progression process of fiber-reinforced ceramic by finite element (FE) analysis. The three-dimensional FE model for three-point bending simulation was 40 mm long, 4 mm wide, 3 mm thick, and with a span length of 30 mm. Nodal force with load increment of 20 N was applied at the center of the upper surface of the beam. To evaluate matrix fracture and fiber fracture, von Mises criterion and Tsai-Hill criterion were used respectively. Consequently, the stress-deflection curve obtained from FE simulation agreed with that obtained from the experimental testing. Differences in flexural strength and modulus between the analytical and experimental results were 1.3 and -2.9% respectively--demonstrating a close agreement between both results. In conclusion, the FE model applied in the present study was shown to be valid for predicting the failure progression of fiber-reinforced ceramics.

Aluminum Oxide↗

AFM tips: how sharp are they?

From both simple estimates and a 'blind' reconstruction based on cryo-AFM images of filamentous actin, we find that the radius of curvature at the apex of Si3N4 tips can be as small as 1 nm with a conical angle in the range 30 approximately 40 degrees, revealing a relatively high aspect ratio that is much greater than previously anticipated. Our results show that commercially available cantilevers are often sharp enough for routine high resolution imaging of biological materials, and suggest that factors other than an inherent blunt tip are probably responsible for frequent occurrences of poor resolution.

Actins↗

High-throughput method for isolating plasmid DNA with reduced lipopolysaccharide content.

Isolating plasmid DNA from bacteria is a fundamental step in molecular biology. It is often accomplished by an alkaline lysis of bacteria and the subsequent adsorption of nucleic acids to silica oxide in the presence of chaotropic substances. Here we show that the addition of such chaotropic reagents is not required for the efficient DNA isolation with silica oxide. This surprising finding allowed us to purify plasmid DNA with significantly less lipopolysaccharides (LPS), which is otherwise a common bacterial contaminant of silica oxide-isolated DNA and inhibits subsequent applications. In addition, we have implemented a precipitation step that altogether leads to a reduction of the LPS content by a factor of 900 relative to published methods. Our novel protocol facilitates an inexpensive high-throughput analysis of pure plasmids in a 96-well format without the addition of hazardous reagents.

Cell Line↗

Single-crystalline ceramic whisker-reinforced carboxylic acid-resin composites with fluoride release.

Currently available glass-ionomer, resin-modified glass-ionomer, and compomer materials have relatively low strength and toughness and, therefore, are inadequate for use in large stress-bearing posterior restorations. In the present study, ceramic single-crystalline whiskers were mixed with fluorosilicate glass particles and used as fillers to reinforce experimental carboxylic acid-resin composites. The carboxylic acid was a monofunctional methacryloxyethyl phthalate (MEP). Five mass fractions of whisker/(whisker + fluorosilicate glass), and corresponding resin (resin + MEP), were evaluated. Four control materials were also tested for comparison: a glass ionomer, a resin-modified glass ionomer, a compomer, and a hybrid composite resin. Flexural specimens were fabricated to measure the flexural strength, elastic modulus, and work-of-fracture (an indication of toughness). Fluoride release was measured by using a fluoride ion selective electrode. The properties of whisker composites depended on the whisker/(whisker + fluorosilicate glass) mass fraction. At a mass fraction of 0.8, the whisker composite had a flexural strength in MPa (mean +/- sd; n = 6) of 150 +/- 16, significantly higher than that of a glass ionomer (15 +/- 7) or a compomer control (89 +/- 18) (Tukey's multiple comparison test; family confidence coefficient = 0.95). Depending on the ratio of whisker:fluorosilicate glass, the whisker composites had a cumulative fluoride release up to 60% of that of a traditional glass ionomer. To conclude, combining ceramic whiskers and fluorosilicate glass in a carboxylic acid-resin matrix can result in fluoride-releasing composites with significantly improved mechanical properties.

Analysis of Variance↗

Repair strength of etched vs silica-coated metal-ceramic and all-ceramic restorations.

The purpose of this in vitro study was to examine shear bond strengths of composite resin to metal-exposed porcelain-fused-to-metal (PFM) and all-ceramic restorations after silica coating or etching with 5% hydrofluoric acid (HF). Specimens were fabricated for each of the following groups: two all-ceramic materials [a feldspathic porcelain (Vita Mark II) and a leucite-reinforced glass-ceramic (IPS Empress)], and one noble metal-ceramic (Orplid Keramik I alloy; Vita VMK 68 N felspathic veneer ceramic). These groups were repaired with resin composites after different pretreatment methods. In one metal-ceramic subgroup the surface exhibited a 50% metal and 50% ceramic exposure. In the silica-coating groups, the specimen surfaces were air abraded with silica acid-modified Al2O3 (CoJet Sand) and treated corresponding to the porcelain repair with resin composite. For control groups, the surfaces were etched with 5% HF for 60 seconds and treated in the same way as the silica-coated groups. After 24 hours of storage (distilled water, 37 degrees C) and an additional 24 hours of thermocycling (1150 x 5 degrees C/55 degrees C) the specimens were debonded using a shear bond strength test (n = 15). In all groups the silica coat repair achieved equal or significantly higher bond strengths than did the etching technique (p < 0.05, Mann-Whitney U test). In the metal-exposed group, the mean bond strength increased from 7.3 MPa to 16.3 MPa following the silica-coat repair. Results indicated that silica coating represents a suitable treatment for the intraoral repair of the materials tested in the present study.

Acid Etching, Dental↗

Association of silicofluoride treated water with elevated blood lead.

UNLABELLED: Previous epidemiological studies have associated silicofluoride-treated community water with enhanced child blood lead parameters. Chronic, low-level dosage of silicofluoride (SiF) has never been adequately tested for health effects in humans. We report here on a statistical study of 151,225 venous blood lead (VBL) tests taken from children ages 0-6 inclusive, living in 105 communities of populations from 15,000 to 75,000. The tests are part of a sample collected by the New York State Department of Children's Health, mostly from 1994-1998. Community fluoridation status was determined from the CDC 1992 Fluoridation Census. Covariates were assigned to each community using the 1990 U.S. Census. Blood lead measures were divided into groups based on race and age. Logistic regressions were carried out for each race/age group, as well as above and below the median of 7 covariates to test the relationship between known risk factors for lead uptake, exposure to SiF-treated water, and VBL >10 microg/dL. RESULTS: For every age/race group, there was a consistently significant association of SiF treated community water and elevated blood lead. Logistic regressions above and below the median value of seven covariates show an effect of silicofluoride on blood lead independent of those covariates. The highest likelihood of children having VBL> 10 microg/dL occurs when they are both exposed to SiF treated water and likely to be subject to another risk factor known to be associated with high blood lead (e.g., old housing). Results are consistent with prior analyses of surveys of children's blood lead in Massachusetts and NHANES III. These data contradict the null hypothesis that there is no difference between the toxic effects of SiF and sodium fluoride, pointing to the need for chemical studies and comprehensive animal testing of water treated with commercial grade silicofluorides.

Black or African American↗

Strengthening composite resin restorations with ceramic whisker reinforcement.

Due to their tendency to fracture, current composite formulations are unsuitable for use in large stress-bearing direct posterior restorations that involve cusps. This study investigated the use of single-crystalline ceramic whiskers for the reinforcement of composite resins. The whisker-reinforced composite materials exhibited physical characteristics (i.e., flexural strength, work-of-fracture, and elastic modulus) that were significantly greater (P < 0.05; Student's t test) than those of traditional composite formulations. The experimental materials also had a surface smoothness that was essentially comparable to hybrid composite control specimens.

Bisphenol A-Glycidyl Methacrylate↗

Molecular abundances in the Sagittarius A molecular cloud.

We have obtained column densities for HCO+, HCO, HCS+, C3H2, HC5N, SiO, OCS, HCOOH, CH3CH2OH, and CH3CCH toward Sgr A. The fractional abundance of SiO relative to molecular hydrogen in Sgr A is comparable to that for the Orion plateau, approximately 10(-7)-10(-8), which may be a typical value for hot clouds. The abundances of HCO, CH3CH2OH and CH3CCH all appear to be enhanced relative to other molecular clouds such as Sgr B2.

Astronomical Phenomena↗

Silicon-based biosensors for rapid detection of protein or nucleic acid targets.

BACKGROUND: We developed a silicon-based biosensor that generates visual, qualitative results or quantitative results for the detection of protein or nucleic acid targets in a multiplex format. METHODS: Capture probes were immobilized either passively or covalently on the optically coated surface of the biosensor. Intermolecular interactions of the immobilized capture probe with specific target molecules were transduced into a molecular thin film. Thin films were generated by enzyme-catalyzed deposition in the vicinity of the surface-bound target. The increased thickness on the surface changed the apparent color of the biosensor by altering the interference pattern of reflected light. RESULTS: Cytokine detection was achieved in a 40-min multiplex assay. Detection limits were 4 ng/L for interleukin (IL)-6, 31 ng/L for IL1-beta, and 437 ng/L for interferon-gamma. In multianalyte experiments, cytokines were specifically detected with signal-to-noise ratios ranging from 15 to 80. With a modified optical surface, specificity was also demonstrated in a nucleic acid array with unambiguous discrimination of single-base changes in a 15-min assay. For homozygous wild-type and homozygous mutant samples, signal-to-noise ratios of approximately 100 were observed. Heterozygous samples yielded approximately equivalent signals for wild-type and mutant capture probes. CONCLUSIONS: The thin-film biosensor allows rapid, sensitive, and specific detection of protein or nucleic acid targets in an array format with results read visually or quantified with a charge-coupled device camera. This biosensor is suited for multianalyte detection in clinical diagnostic assays.

Biosensing Techniques↗

Desensitizing efficacy of a new dentifrice containing 5.0% potassium nitrate and 0.454% stannous fluoride.

PURPOSE: To evaluate the relative effectiveness provided by a new dentifrice containing 5.0% potassium nitrate and 0.454% stannous fluoride in a silica base (Colgate Sensitive Maximum Strength) for reducing dentin hypersensitivity over an 8-wk period, as compared to that provided by a commercially-available antihypersensitivity dentifrice containing 5.0% potassium nitrate and 0.76% sodium monofluorophosphate in a dicalcium phosphate base (Fresh Mint Sensodyne dentifrice). MATERIALS AND METHODS: To qualify for participation in this examiner-blind study, male and female adults from the San Francisco, California area were required to present with tactile and air blast dentin hypersensitivity in at least 2 non-molar teeth at two examinations, spaced 1 wk apart. Qualifying subjects were randomized into two treatment groups, which were balanced for gender, age, and baseline sensitivity scores. Subjects were provided with a soft-bristled toothbrush. Examinations for tactile and air blast sensitivity were repeated after 4 wks' use of the study dentifrices, and again after 8 wks' usage. RESULTS: 101 subjects complied with the protocol, and completed the entire study. After 4 wks, subjects assigned to the Colgate Sensitive Maximum Strength group exhibited a statistically significant improvement over the Fresh Mint Sensodyne dentifrice group with respect to tactile sensitivity scores, and a statistically significant improvement over the Sensodyne dentifrice group with respect to air blast sensitivity scores. Correspondingly significant improvements were presented after 8 wks. Thus, the results of this examiner-blind clinical study support the conclusion that Colgate Sensitive Maximum Strength dentifrice provided superior levels of control of tactile and air blast sensitivity than did the clinically tested, commercially-available Sensodyne anti-hypersensitivity dentifrice.

Adult↗

Desensitizing efficacy of Colgate Sensitive Maximum Strength and Fresh Mint Sensodyne dentifrices.

PURPOSE: To investigate the relative effectiveness provided by a new dentifrice containing 5.0% potassium nitrate and 0.454% stannous fluoride in a silica base (Colgate Sensitive Maximum Strength dentifrice) for reducing dentin hypersensitivity over an 8-wk period, as compared to that provided by a commercially-available antihypersensitivity dentifrice containing 5.0% potassium nitrate and 0.76% sodium monofluorophosphate in a dicalcium phosphate base (Fresh Mint Sensodyne dentifrice). MATERIALS AND METHODS: To qualify for participation in this examiner-blind clinical study, male and female adults from the central New Jersey area were required to present with tactile and air blast dentin hypersensitivity in at least two non-molar teeth at two examinations, spaced 1 wk apart. Qualifying subjects were randomized into two treatment groups, which were balanced for gender, age, and baseline sensitivity scores. Subjects were provided with a soft-bristled toothbrush. Examinations for tactile and air blast sensitivity were repeated after 4 wks' use of the study dentifrices, and again after 8 wks' usage. 97 subjects complied with the protocol, and completed the entire study. RESULTS: After 4 wks, subjects assigned to the Colgate Sensitive Maximum Strength dentifrice group exhibited a statistically significant improvement over the Sensodyne dentifrice group with respect to tactile sensitivity scores, and a statistically significant improvement over the Sensodyne dentifrice group with respect to air blast sensitivity scores. Correspondingly significant improvements were presented after 8 wks. Thus, the results of this examiner-blind clinical study support the conclusion that the Colgate Sensitive Maximum Strength dentifrice containing 5.0% potassium nitrate and 0.454% stannous fluoride in a silica base provided superior levels of control of tactile and air blast sensitivity than the clinically tested, commercially-available anti-hypersensitivity dentifrice Sensodyne dentifrice containing 5.0% potassium nitrate and 0.76% sodium monofluorophosphate in a dicalcium phosphate base.

Adult↗

[Histomorphometry of silicon nitride composite endosteal implant in dogs].

OBJECTIVE: To study the dynamic changes of bone interface with silicon nitride (Si3N4) composite implants. METHODS: 4 Beagle dogs were experimental animals, Si3N4-HA and pure Si3N4 implant were experimental group, and Ti and Ti-HA were used as comparisons. They were implanted into dogs' femurs by stages. Histomorphometry was used to analyse and compare bone growth metabolism of bone interface with implant as well as evaluation of biocompatibility from quantitative and dynamic aspects. RESULTS: Parameters expressing mineralization and speed of deposition at the Si3N4-HA bone interface were higher than comparisions' at the first month. After 6 months, pure Si3N4's bone histomorphometic parameters had no notable difference with others. CONCLUSION: New implant material is useful to the clinic. The histomorphometry is of much value for the study of interface bone metabolism from quantitative and dynamic point of view.

Animals↗

A new desensitizing dentifrice--an 8-week clinical investigation.

An 8-week, double-blind, three-way clinical trial compared the dentinal hypersensitivity-reducing effectiveness of a new dentifrice containing 5.0% potassium nitrate and 0.454% stannous fluoride in a silica base (Colgate Sensitive Maximum Strength Toothpaste, Colgate-Palmolive Co.) with a commercially available desensitizing dentifrice containing 5.0% potassium nitrate and 0.243% sodium fluoride in a silica base (Sensodyne Fresh Mint Toothpaste, Block Drug Company, Inc.) and a nondesensitizing dentifrice containing 0.243% sodium fluoride in a silica base (Colgate Winterfresh Gel, Colgate-Palmolive Co.). One hundred nine subjects were stratified into three balanced groups according to gender, age, mean baseline tactile (Yeaple Probe), and thermal (air blast) scores. The test products were randomly assigned to each group with instructions to brush twice daily. Oral examinations with tactile and thermal assessments were repeated after 4 and 8 weeks. The new dentifrice group demonstrated statistically significant improvements in tactile and thermal sensitivity over the two control groups.

Adult↗

Comparative investigation of the desensitizing efficacy of a new dentifrice: a 14-day clinical study.

The effect on dentinal hypersensitivity from the use of a new formulation dentifrice containing 5.0% potassium nitrate and 0.454% stannous fluoride in a silica base (Colgate Sensitive Maximum Strength Toothpaste, Colgate-Palmolive Co.) over a 14-day period was compared to a commercially available, nondesensitizing control dentifrice (Colgate Winterfresh Gel, Colgate-Palmolive Co.). A total of 66 subjects were entered into and completed the study. They were stratified into two balanced groups according to their baseline mean tactile (Yeaple Probe) sensitivity scores and air blast (thermal) sensitivity scores. The two groups were randomly assigned to use either the new formulation dentifrice or the commercially available control dentifrice. Participants were instructed to brush their teeth twice daily (morning and evening) for 1 minute with their assigned dentifrice and a commercially available soft-bristled toothbrush. Dentinal hypersensitivity examinations (tactile and air blast sensitivity) were conducted at baseline and after 3, 7, 10, and 14 days' use of the products. All examinations were conducted by the same examiner. Participants who used the new formulation dentifrice containing potassium nitrate/stannous fluoride/silica demonstrated a statistically significant improvement in both tactile sensitivity and air blast sensitivity after 10 and 14 days' use of the dentifrice (p < 0.05), as compared to a commercially available control dentifrice. It was concluded that a new dentifrice formulation containing 5.0% potassium nitrate and 0.454% stannous fluoride in a silica base provided a statistically significant reduction in dentinal hypersensitivity after only 10 days, as compared to a commercially available nondesensitizing control dentifrice.

Adult↗

Clinical study to compare extrinsic stain formation in subjects using three dentifrice formulations.

The purpose of this study was to compare the degree of extrinsic dental stain formed with the use of three dentifrices: (1) a new dentifrice formulation containing 5.0% potassium nitrate and 0.454% stannous fluoride in a silica base (Colgate Sensitive Maximum Strength Toothpaste, Colgate-Palmolive Co.); (2) a commercially available dentifrice containing 5.0% potassium nitrate and 0.243% sodium fluoride in a silica base (Sensodyne Fresh Mint Toothpaste, Block Drug Company, Inc.); and (3) a dentifrice containing 0.243% sodium fluoride in a silica base (Colgate Winterfresh Gel, Colgate-Palmolive Co.). A total of 121 participants were entered into the study and stratified into 3 balanced groups according to baseline mean Lobene Stain Index scores. A thorough dental prophylaxis was completed on each participant after completion of the baseline examination. The three groups were randomly assigned to use one of the three dentifrices. The groups were well balanced with regard to mean baseline stain index scores, gender, and tobacco habits. Participants were instructed to brush their teeth twice daily (morning and evening) for 1 minute with their assigned dentifrice and a commercially available soft-bristled toothbrush. Extrinsic dental stain examinations, which measured dental stain area and dental stain intensity, were conducted at baseline and 4 and 8 weeks. Examinations were conducted by the same dental examiner at each examination. After 4 and 8 weeks' use of the test dentifrices, there was no statistically significant difference regarding extrinsic stain formation with the use of any of the dentifrices. Thus, it can be concluded from this study that the use of a new formulation dentifrice containing 5.0% potassium nitrate and 0.454% stannous fluoride in a silica base will not result in a greater formation of extrinsic dental staining than that which is formed by two commercially available dentifrices not known to cause extrinsic dental stain.

Adolescent↗