PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Silicon Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52Linked to original sources

A randomized clinical trial of the desensitizing efficacy of three dentifrices.

The effect on dentinal hypersensitivity from the use of a new dentifrice containing 5.0% potassium nitrate and 0.454% stannous fluoride in a silica base (Colgate Sensitive Maximum Strength Toothpaste, Colgate-Palmolive Co.) over an 8-week period was compared to a commercially available dentifrice containing 5.0% potassium nitrate and 0.243% sodium fluoride in a silica base (positive control [Sensodyne Fresh Mint Toothpaste, Block Drug Company, Inc.]) and to a commercially available nondesensitizing dentifrice containing 0.243% sodium fluoride in a silica base (negative control [Colgate Winterfresh Gel, Colgate-Palmolive Co.]). A total of 120 participants were stratified into 3 balanced groups according to baseline mean air blast (thermal) and tactile (Yeaple Probe) sensitivity scores, gender, and age. Participants brushed their teeth twice daily (morning and evening) for 1 minute. Dentinal hypersensitivity examinations were conducted at baseline, 4 weeks, and 8 weeks by the same dental examiner. After 4- and 8-weeks' use of their assigned products, participants in the new dentifrice group demonstrated statistically significant improvements (p < 0.05) in tactile and air blast sensitivity, as compared to those using the positive and negative control dentifrices.

Adult↗

[Surgical management of the capsular contraction syndrome].

PURPOSE/METHODS: To describe a surgical technique to treat severe capsular contraction syndrome. A secondary continuous curvilinear capsulorhexis was performed in four cases of capsular phymosis, attended in our clinic. CONCLUSIONS/RESULTS: All of them resolved with good anatomic and functional results, no recurrence occurred and best correct visual acuity BCVA was preserved after a twelve- month follow-up. This surgical procedure could solve severe capsular contraction syndrome occurring after continuous curvilinear capsulorhexis, phacoemulsification and intraocular lens implantation.

Aged↗

[Nutrients in sediment pore water in tidal flat area in Yalujiang Estuary].

The concentrations of NO3-, PO(4)3- and SiO(3)2- in sediment pore waters from tidal flat area in Yalujiang Estuary were determined. The concentration of NO3- in sediment pore waters was almost stable, the average NO3- was 3.0 mumol/L. The concentration of PO(4)3- and SiO(3)2- were 0.8-70.4 mumol/L and 111.6-1054.3 mumol/L, respectively. The depth distribution of PO(4)3- and SiO(3)2- increased with depth at first and then decreased further down. The content of S2- in sediment raise with depth. Under the depth of 13 cm, Eh decreased into minus. pH did not obviously change with depth. The diffusion of nutrients in tidal flat area in Yalujiang estuary was from pore water into overlying water.

China↗

[Transcatheter renal arterial embolization in malignant renal neoplasms: clinical results and indications for use of the method in multi-profile hospitals].

The authors analyse the long-term and in-hospital results of treatment 29 patients with renal neoplasms, who underwent transcatheter renal arterial embolization and also discuss the benefits of transcatheter renal arterial embolization in other clinical situations. Transcatheter renal arterial embolization was performed with embosil for 23 patients (79.3%) and with concentrated alcohol for 6 patients (20.7%) before nephrectomy of advance renal tumour in 21 patients. Transcatheter renal arterial embolization was performed as palliative treatment in 8 patients. Complete embolization was achieved in 27 patients (93.1%), incomplete--in 2 patients (6.9%). Nephrectomy was performed after 22.14 +/- 9.28 days. The most evident post procedural reactions were moderately elevated temperature in 22 patients (75.9%), highly elevated temperature (> 38 degrees) in 7 patients (24.1%) and pain. Only 6 patients (20.7%) didn't feel pain. One hematoma was noticed in puncture region. After 5 years, 4 patients of 10 analysed patients are still alive (all-pT3, size of tumor 6.5-9 cm.). Two patients were not operated due to very big tumor and technical inoperability. Remaining 4 patients died during 2-3 years. As exclusion was one patient with inoperable renal tumor and lung metastases. After transcatheter renal arterial embolization he was alive 4 years. In conclusion, transcatheter renal arterial embolization was effective in diminishing the technical difficulties to remove advance tumors and in treatment of inoperable patients. It's rational to supply transcatheter renal arterial embolization with embolization and chemoembolization of primary and metastatic lesions.

Aged↗

Implantation of the VentrAssist Implantable Rotary Blood Pump in sheep.

The VentrAssist Implantable Rotary Blood Pump (IRBP) is a hydrodynamically suspended, electromagnetically driven, centrifugal blood pump that provides continuous flow of up to 10 L/min at 3,000 rpm. In vivo studies in sheep were conducted to assess system design and performance. Surgery involved thoracotomy with subdiaphragmatic pump placement. Cannulae were transdiaphragmatic, with inflow in the left ventricular apex and outflow anastomosed to the descending aorta. Animals had no anticoagulation or antiplatelet therapy after surgery and no prophylactic antibiotics after recovery. Twelve sheep were supported for 622 pump days. Estimated pump flow ranged from 1 to 5.5 L/min at 1,800 to 2,000 rpm using 2.5 to 4.5 W. There was no clinical evidence of hemolysis or cardiovascular, renal, or hepatic dysfunction. Adverse outcomes included kinking/disconnection of the outflow cannula caused by the graft bend relief (n = 4), which was addressed through cannula redesign. Pump electrical malfunction (n = 4), caused by a silicone potting compound, was corrected using a neutral curing potting material. Surgical/husbandry issues (n = 2) also were addressed. The VentrAssist IRBP provides high flow at low rotational speed and power consumption. Further trials are in progress in advance of in vivo studies of the safety and efficacy of the final system.

Animals↗

[Surface Ramam spectropscopy for in situ investigating silicon etching process].

In situ surface Raman spectroscopy has been extended to study silicon electrode surfaces by optimizing the Raman system and the surface roughening method. The time-dependent etching processes were monitored in a dilute HF aqueous solution and the initial oxidation processes of the hydrogen-terminated surface in different pHs were studied at the open circuit potential. The results indicate that the silicon surface could be overwhelmingly terminated with hydrogen rather than fluorine in the HF-based solution. The smoothening effect of OH- on the silicon surface is through the attack of the = SiH2 site. It demonstrates that Raman spectroscopy is a powerful in situ technique for investigating the etching process of silicon surface.

Electrochemistry↗

[Study on the photoluminescence spectrum of nickel passivation treatment of porous silicon].

A new method for electrolysis passivation treatment of porous silicom (PS) in NiCl2 is reported in this paper. The photoluminescence (PL) spectra of PS treated in different time is observed, the spectra show that peak intensity is 2.5 times stronger than that without treatment, peak wavelength is 33 nm blue shift when PS is treated properly. The phenomenon caused is that the results of the SiHx change into SiNix when replaced H by Ni on surface of PS.

Chemical Phenomena↗

[Raman analysis of SiGe films grown by UHV/CVD].

This paper presents a Raman method, which is no deconstructed, to measure Ge content and strain in SiGe alloy films and some samples, which is grown by UHV/CVD with different Ge content and thickness, have been tested by above method. Two samples among them were measured by DCXRD, the results tested by DCXRD are consistent with Raman results that proves that the method in this paper is reliable and accurate. The SiGe PHMOSFET has been fabricated by the samples, the transconductance reaches 112 ms.mm-1 for the device with 0.5 micron channel.

Alloys↗

[Determination of Fe, Al, Ca in silicon metal by XRF spectrometry].

Fe, Al, Ca in silicon metal were measured by XRF using powder pressed method to prepare the sample. The conditions of preparing the sample disc were discussed, and the strength of the sample disc, was solidified through the binder added. Interelement absorption and enhancement effects are corrected by using the experience coefficient method. The precision and accuracy of the XRF method are excellent as compared with classical chemical method.

Aluminum↗

[Photoluminescence from Er-doped silicon-rich silicon oxide film and Er-doped silicon-rich silicon nitride film and its annealing behavior].

Room temperature photoluminescence (PL) with a peak at 1.54 microns was observed from silicon oxide, silicon-rich silicon oxide, silicon nitride and silicon-rich silicon nitride films, all doped with Er and grown by the magnetron sputtering technique. To determine the optimum annealing temperature for the 1.54 microns PL, these films were annealed in the range of 600-1,100 degrees C with an interval of 100 degrees C. Among these four types of films annealed at an identical temperature, the intensity of 1.54 microns PL peak of the Er-doped silicon-rich silicon oxide film was always the strongest one, which arrived at a maximum in 800 degrees C annealing. A 1.38 microns PL band was also observed in each of these four types of films, and which in the silicon-rich silicon oxide or silicon-rich silicon nitride films was found to be correlated with the 1.54 microns PL band in intensity.

Chemical Phenomena↗