PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53Linked to original sources

Microfluidic synthesis of colloidal silica.

We demonstrate the design, fabrication, and operation of microfluidic chemical reactors for the synthesis of colloidal silica particles. Two reactor configurations are examined: laminar flow reactors and segmented flow reactors. We analyze particle sizes and size distributions and examine their change with varying linear flow velocity and mean residence time. Laminar flow reactors are affected by axial dispersion at high linear velocities, thus leading to wide particle size distributions under these conditions. Gas is used to create a segmented flow, consisting liquid plugs separated by inert gas bubbles. The internal recirculation created in the liquid plugs generates mixing, which eliminates the axial dispersion effects associated with laminar flow reactors and produces a narrow size distribution of silica nanoparticles.

Journal Article↗

Microfluidics: from dynamic lattices to periodic arrays of polymer disks.

We used coupling of flow and geometric confinement to assemble emulsion droplets in two-dimensional gliding lattices with a high degree of order and symmetry. Highly monodisperse discoid droplets with circular shapes were generated in a microfluidic flow-focusing device. Originally, close-packed lattices formed from these circular discoid droplets. Progressive confinement led to the gradual deformation of the circular disks: first, they elongated in the direction parallel to the direction of flow and then transformed into hexagons. Assembly driven by the combination of flow and confinement also allowed for the formation of lattices from droplets with a bimodal size distribution. We used photopolymerization of the monomer droplets to trap the lattice structure in the solid state and produce highly periodic arrays of solid polymer disks.

Journal Article↗

Diffusion of hydrosilanes from the control layer to the vinylsilane-rich flow membrane during the fabrication of microfluidic chips.

During the fabrication of poly(dimethylsiloxane) (PDMS)-based microfluidic chips, polymethylhydrosiloxane (PMHS) species in the control layer diffuse into the flow membrane, which contains polymethylvinylsiloxane (PMVS), and the components cross-link together to form the mechanically enhanced membrane. The diffusion course was investigated by using attenuated total reflectance FTIR and the improvement of mechanical properties of the flow membrane was studied by measuring the Young's modulus and the tensile strength.

Journal Article↗

Characterization of transverse channel concentration profiles obtainable with a class of microfluidic networks.

We analyze mathematically a previously reported class of passive microfluidic mixing networks. The networks produce nonhomogeneous concentrations in the output channel, resulting in diverse concentration profiles. We formally prove that all profiles obtainable with this class of networks can be described as polynomials of degree no higher than the number of input channels less one. We derive explicit formulas for the calculation of resultant output concentration profiles and conversely for the calculation of input concentrations needed to obtain set output profiles.

Journal Article↗

Microfluidic protein detection through genetically engineered bacterial cells.

Protein microarray technology, in which a large number of capture ligands are spatially arrayed at a high density, presents an attractive method for high-throughput proteomic analysis. Toward this end, we demonstrate the first cell-based protein detection in a microsystem, wherein Escherichia coli cells are genetically engineered to express the desired capture proteins on the membrane surface and are spatially arrayed as sensing elements in a microfluidic device. An E. coli clone expressing peptide ligands with high affinity and high specificity for target molecules was isolated a priori. Then these cells were electrokinetically immobilized on gold electrodes using dielectrophoresis, thus allowing each sensor element to be electrically addressable. Flow cytometry and subsequent fluorescence analysis verified the highly specific capture and detection of target molecules by the bacteria. Finally, through the coexpression of peptide-based capture ligands on the cell surface and fluorescent protein in the cytoplasm, we demonstrate an effective means of directly linking the fluorescence intensity to the density of capture ligands.

Escherichia coli↗

Functional hydrogel structures for autonomous flow control inside microfluidic channels

Hydrogels have been developed to respond to a wide variety of stimuli, but their use in macroscopic systems has been hindered by slow response times (diffusion being the rate-limiting factor governing the swelling process). However, there are many natural examples of chemically driven actuation that rely on short diffusion paths to produce a rapid response. It is therefore expected that scaling down hydrogel objects to the micrometre scale should greatly improve response times. At these scales, stimuli-responsive hydrogels could enhance the capabilities of microfluidic systems by allowing self-regulated flow control. Here we report the fabrication of active hydrogel components inside microchannels via direct photopatterning of a liquid phase. Our approach greatly simplifies system construction and assembly as the functional components are fabricated in situ, and the stimuli-responsive hydrogel components perform both sensing and actuation functions. We demonstrate significantly improved response times (less than 10 seconds) in hydrogel valves capable of autonomous control of local flow.

Journal Article↗

Microfluidic systems: high radial acceleration in microvortices.

Microfluidic systems can conveniently be used for rapid analysis of biological samples. Here we describe a single re-circulating flow, or microvortex, that can generate a maximum fluid rotational velocity of up to 12 m s(-1) and a corresponding radial acceleration in excess of 10(6)g. Such microvortices may be exploited in centrifugal microdevices to investigate the effects of high radial acceleration on biological and chemical processes.

Journal Article↗

mRNA isolation in a microfluidic device for eventual integration of cDNA library construction.

mRNA isolation for the purpose of cDNA library construction was performed in a microfluidic chip device using paramagnetic oligo-dT beads. The simple Y-intersection flow design mixes beads and sample on-chip, and uses magnetic trapping to capture, then release the beads. The capillary gel electrophoresis (CGE) detection of the total unamplified mRNA isolated on-chip, and of a reverse transcription-polymerase chain reaction (RT-PCR) amplified rare gene indicated that mRNA could be captured by oligo-dT beads on-chip, had very good integrity and was suitable for constructing a cDNA library. The limit of detection for the rare bicoid gene of Drosophila Melanogaster corresponded to the capture of approximately 2.8 ng of total mRNA from 0.85 microgram of total RNA (TRNA) within the microchip. As much as 34 ng of total mRNA was estimated to be captured from 10 micrograms of TRNA.

Animals↗

Velocity measurement of particulate flow in microfluidic channels using single point confocal fluorescence detection.

This article presents a non-invasive, optical technique for measuring particulate flow within microfluidic channels. Confocal fluorescence detection is used to probe single fluorescently labeled microspheres (0.93 microm diameter) passing through a focused laser beam at a variety of flow rates (50 nL min(-1)-8 microL min(-1)). Simple statistical methods are subsequently used to investigate the resulting fluorescence bursts and generate velocity data for the flowing particles. Fluid manipulation is achieved by hydrodynamically pumping fluid through microchannels (150 microm wide and 50 microm deep) structured in a polydimethylsiloxane (PDMS) substrate. The mean fluorescence burst frequency is shown to be directly proportional to flow speed. Furthermore, the Poisson recurrence time and width of recovered autocorrelation curves is demonstrated to be inversely proportional to flow speed. The component-based confocal fluorescence detection system is simple and can be applied to a diversity of planar chip systems. In addition, velocity measurement only involves interrogation of the fluidic system at a single point along the flow stream, as opposed to more normal multiple-point measurements.

Microscopy, Confocal↗

Glow discharge in microfluidic chips for visible analog computing.

Here we present a novel visible analog computing approach for solving a wide class of shortest path problems. Using a microfluidic chip for computation, based on the lighting up of a glow discharge, the solution to maze search problems, the solution of a network shortest path and k-shortest paths problems and the practical application of finding the shortest paths between several landmarks from a street map are presented. The solution and visible display (in real time) for these problems shows only a small difference in practical problem solving time among problems with varying differences in size.

Journal Article↗

Characterization and optimization of slanted well designs for microfluidic mixing under electroosmotic flow.

Recently, a series of slanted wells on the floor of a microfluidic channel were experimentally shown to successfully induce off-axis transport and mixing of two confluent streams when operating under electroosmotic (EO) flow. This paper will further explore, through numerical simulations, the parameters that affect off-axis transport under EO flow with an emphasis on optimizing the mixing rate of (a). two confluent streams in steady-state or (b). the transient scenario of two confluent plugs of material, which simulates mixing after an injection. For the steady-state scenario, the degree of mixing was determined to increase by changing any of the following parameters: (1). increasing the well depth, (2). decreasing the well angle relative to the axis of the channel, and (3). increasing the EO mobility of the well walls relative to the mobility of the main channel. Also, it will be shown that folding of the fluid can occur when the well angle is sufficiently reduced and/or when the EO mobility of the wells is increased relative to the channel. The optimum configuration for the transient problem of mixing two confluent plugs includes shallow wells to minimize the well residence time, and an increased EO mobility of the well walls relative to the main channel as well as small well angles to maximize off-axis transport. The final design reported here for the transient study reduces the standard deviation of the concentration across the channel by 72% while only increasing the axial dispersion of the injected plug by 8.6 % when compared to a plug injected into a channel with no wells present. These results indicate that a series of slanted wells on the wall of a microchannel provides a means for controlling and achieving a high degree of off-axis transport and mixing in a passive manner for micro total analysis system (microTAS) devices that are driven by electroosmosis.

Journal Article↗

Effects of liquid conductivity differences on multi-component sample injection, pumping and stacking in microfluidic chips.

As an increasing number of processes are being integrated into Lab-on-a-chip devices, there is an increasing need for flexible and accurate sample manipulation techniques for effective transport and separation. Conductivity differences between running buffer and analyte samples can arise as a product of on-chip processing, or by design. The two situations studied here are sample pumping (where bulk transport is increased and separation of charged analytes is delayed using a relatively high conductivity sample), and sample stacking (where bulk transport is decreased and separation of charged analytes is expedited using a relatively low conductivity sample). A recently developed dynamic loading method for on-chip sample injection in a straight-cross channel configuration is applied here to both pumping and stacking cases. A key characteristic of the dynamic loading method is the ability to inject samples of high concentration density and uniformity of any length. By employing the conductivity differences alone, the effectiveness of either sample transport or sample separation are shown to improve over the uniform conductivity case. Then it is demonstrated that increasing the sample length, through dynamic loading, greatly increases the effectiveness of sample pumping, evidenced in an eight-fold increase in peak height as well as a decrease in total sample length at a downstream detector. Dynamic loading in the sample stacking case was shown to also increase peak intensity height (three-fold) in rapid separations. These results demonstrate that the dynamic loading technique, used in conjunction with strategic conductivity differences, significantly extends the capabilities of microfluidic chips.

Journal Article↗

A novel in-plane passive microfluidic mixer with modified Tesla structures.

An innovative in-plane passive micromixer using modified Tesla structures, which are used as passive valves, has been designed, simulated, fabricated and successfully characterized in this paper. Simulation and experimental results of the developed novel micromixer have shown excellent mixing performance over a wide range of flow conditions in the micro scale. The micromixer realized in this work has achieved even better mixing performance at a higher flow rate, and its pressure drop is less than 10 KPa at the flow rate of 100 microl min(-1). This micromixer shows characteristics similar to Taylor dispersion, with contributions from both diffusion and convection. The mixer has a diffusion domain region at low flow rate, but it moves to a convection domain region at high flow rate. Due to the simple in-plane structure of the novel micromixer explored in this work, the mixer can be easily realized and integrated with on-chip microfluidic devices and micro total analysis systems (micro-TAS).

Journal Article↗

Rapid droplet mixers for digital microfluidic systems.

The mixing of analytes and reagents for a biological or chemical lab-on-a-chip is an important, yet difficult, microfluidic operation. As volumes approach the sub-nanoliter regime, the mixing of liquids is hindered by laminar flow conditions. An electrowetting-based linear-array droplet mixer has previously been reported. However, fixed geometric parameters and the presence of flow reversibility have prevented even faster droplet mixing times. In this paper, we study the effects of varying droplet aspect ratios (height:diameter) on linear-array droplet mixers, and propose mixing strategies applicable for both high and low aspect ratio systems. An optimal aspect ratio for four electrode linear-array mixing was found to be 0.4, with a mixing time of 4.6 seconds. Mixing times were further reduced at this ratio to less than three seconds using a two-dimensional array mixer, which eliminates the effects of flow reversibility. For lower aspect ratio (</=0.2) systems, we present a split-and-merge mixer that takes advantage of the ability to perform droplet splitting at these ratios, resulting in a mixing time of less than two seconds.

Journal Article↗

Continuous synthesis of CdSe-ZnS composite nanoparticles in a microfluidic reactor.

ZnS-coated CdSe composite particles have been continuously synthesized in a microfluidic reactor. By using this system, CdSe particles and a ZnS coating can be produced in sequence, and the particle size and layer thickness can be directly adjusted by the residence time. It demonstrated that the continuous synthesis in the microreactor was a simple and efficient way to prepare composite particles with different structures and determine the optimized experimental conditions.

Journal Article↗

Design of passive mixers utilizing microfluidic self-circulation in the mixing chamber.

This paper proposes the design of a passive micromixer that utilizes the self-circulation of the fluid in the mixing chamber for applications in the Micro Total Analysis Systems (microTAS). The micromixer with a total volume of about 20 microL and consisting of an inlet port, a circular mixing chamber and an outlet port was designed. The device was actuated by a pneumatic pump to induce self-circulation of the fluid. The self-circulation phenomenon in the micromixer was predicted by the computational simulation of the microfluidic dynamics. Flow visualization with fluorescence tracer was used to verify the numerical simulations and indicated that the simulated and the experimental results were in good agreement. Besides, an index for quantifying the mixing performance was employed to compare different situations and to demonstrate the advantages of the self-circulation mixer. The mixing efficiencies in the mixer under different Reynolds numbers (Re) were evaluated numerically. The numerical results revealed that the mixing efficiency of the mixer with self-circulation was 1.7 to 2 times higher than that of the straight channel without a mixing chamber at Re= 150. When Re was as low as 50, the mixing efficiency of the mixer with self-circulation in the mixing chamber was improved approximately 30% higher than that in the straight channel. The results indicated that the self-circulation in the mixer could enhance the mixing even at low Re. The features of simple mixing method and fabrication process make this micromixer ideally suitable for microTAS applications.

Journal Article↗