Reproducibility of mean transit time for maximal myocardial flow assessment by videodensitometry.

In the assessment of myocardial perfusion by ECG-triggered digital radiography, time parameters are calculated from the time density curve (TDC) and related to blood flow. Recently we developed a method which uses mean transit time (Tmn) as time parameter, and which is in accordance with the original principles of indicator dilution theory. In this approach, variability in vascular volume is excluded and Tmn-1, determined at maximal hyperemia, showed an excellent correlation with maximal flow in animal validation studies. For calculation of Tmn, however, a large part of the descending limb of the TDC has to be known for reliable extrapolation, and especially this part of the curve is subject to variability in image quality in man. Therefore we tested reproducibility of Tmn in 30 arteries in 20 patients. Tmn was derived from the TDCs, obtained from paired studies under identical circumstances with an interval of 10 minutes. Satisfactory images could be obtained in all but one patient. Image processing was performed in an identical way in the paired studies. Reproducibility proved to be excellent for all three coronary arteries. The absolute value of the relative differences between the first and second determination was 7 +/- 7% for the LAD, 6 +/- 3% for LCx and 4 +/- 2% for the RCA (mean +/- SD). Correlation coefficients between both measurements were 0.97, 0.95 and 0.95 for the respective arteries. Therefore, it is concluded that, using this approach, Tmn at maximal hyperemia can be determined reproducibly in man and used for maximal myocardial flow assessment.

Absorptiometry, Photon↗

Intraobserver and interobserver reproducibility of WHO and Gleason histologic grading systems in prostatic adenocarcinomas.

In this study a total of 96 patients with prostatic carcinoma were evaluated retrospectively. Sections prepared from paraffin blocks were examined and all cases were scored according to the World Health Organization (WHO) and Gleason grading systems. We investigated intraobserver and interobserver reproducibility of two grading systems in prostatic adenocarcinomas. In our study the intraobserver reproducibilities of the WHO and Gleason systems were 75.0% and 78.1%, respectively. The interobserver reproducibilities of the WHO and Gleason grading systems were 60.4% and 70.8%, respectively. While there was no difference between intraobserver and interobserver variations in the Gleason system (p > 0.05), there was significant difference between intraobserver and interobserver variations in the WHO system (p < 0.05).

Adenocarcinoma↗

Reproducibility of dopamine transporter density measured with 123I-FPCIT SPECT in normal control and Parkinson's disease patients.

UNLABELLED: The objective of this study was to evaluate the reproducibility of 123I-FPCIT SPECT by using whole striatal region of interest (ROI) and subdivided ROI in normal controls (NC) and Parkinson's disease (PD) patients. METHODS: Ten NC and 6 PD received a SPECT scan for 6 hours postinjection of FPCIT. The distribution volume ratio (R(V)) and specific-nonspecific tissue activity ratio (RT) were measured as an outcome measure. The test/retest reproducibility of R(V) and R(T) was evaluated by calculating the test/retest difference, variability, and reliability. RESULTS: There were no significant test/retest differences for any regions in either the NC or PD. The test/retest variability/reliability of Rv was 5.53+/-4.12%/0.89 in NC, 4.50+/-5.31%/0.99 in PD with whole striatal ROI, 4.29+/-0.78%/ 0.94+/-0.03 in NC, and 6.87+/-1.23 %/0.98+/-0.01 in PD with subdivided ROI. The test/retest variability/reliability of RT was 11.1+/-10.4%/0.59 in NC, 7.84+/-8.94%/0.95 in PD with whole striatal ROI, 11.9+/-1.22%/0.65+/-0.06 in NC, and 12.2+/-4.00%/0.95+/-0.03 in PD with subdivided ROI. CONCLUSION: R(V) is highly reproducible and reliable compared with RT in both NC and PD as an outcome measure.

Adult↗

[Reproducibility and interchangeability of the Thromboelastograph, Sonoclot and Hemochron activated coagulation time in cardiac surgery].

PURPOSE: Despite their common use in cardiac surgery, few studies have evaluated the reproducibility of the Thromboelastograph (TEG), of the Sonoclot (SCT), and of the activated coagulation time with celite (ACT-C) or kaolin (ACT-K) measured with the Hemochron, in clinical conditions of on-site monitoring of hemostasis. This study determined the reproducibility of those measurements, and evaluated the ability of various devices to substitute for the ACT-C. METHODS: Blood samples collected from 20 volunteers and 21 patients undergoing myocardial revascularization were analyzed in the two channels of the TEG, in two SCT and four Hemochron analyzers. The overall of TEG and SCT coagulation profiles were analyzed by a computerized TEG and an experienced observer respectively. The variation rate (V%) was calculated for each variable. The ability of ACT-K and SCT to substitute for ACT-C under different clinical conditions was evaluated. RESULTS: ACT-C and ACT-K V% ranged between 5.6% and 10.8% and between 6.7% and 12.4% respectively. TEG and SCT V% ranged between 3.1% and 9.5% and between 5.8% and 33.6% respectively, according to different conditions and parameters. In volunteers and non-heparinized patients, the ACT-C and ACT-K were interchangeable. No other test can substitute for the ACT-C when patients are heparinized during cardiopulmonary bypass (CPB). CONCLUSIONS: In the clinical conditions of use, on-site hemostasis monitoring devices providing the most reproducible measurements are, in decreasing order, the TEG, the Hemochron and the SCT. In heparinized patients and during CPB, results from different tests are not interchangeable, stressing the importance of establishing appropriate instrument-specific values for monitoring anticoagulation during cardiac surgery.

Adult↗

Reproducibility of serial peri-ictal single-photon emission tomography difference images in epilepsy patients undergoing surgical resection.

Peri-ictal single-photon emission tomography (SPET) difference images co-registered to magnetic resonance imaging (MRI) visualize regional cerebral blood flow (rCBF) changes and help localize the epileptogenic area in medically refractory epilepsy. Few reports have examined the reproducibility of SPET difference image results. Epilepsy patients having two peri-ictal and at least one interictal SPET scan who later underwent surgical resection were studied. Localization accuracy of peri-ictal SPET difference images results, interictal electroencephalography (EEG), and ictal EEG from the first (seizure 1) and second (seizure 2) seizure, as well as MRI and positron emission tomography (PET) findings, were compared using surgical resection site as the standard. Thirteen patients underwent surgical resection (11 temporal lobe and 2 extratemporal). SPET results from seizure 1 were localized to the surgical site in 12/13 (92%) patients, while SPET results from seizure 2 were localized in 13/13 (100%) patients. All other modalities were less accurate than the SPET results interictal EEG--seizure 1 6/13 (46%); ictal EEG--seizure 1 5/13 (38%); interictal intracranial EEG--seizure 2 4/9 (44%); ictal intracranial EEG--seizure 2 results 8/9 (89%); MRI 6/13 (46%); PET 9/13 (69%)[. SPET results were reproducible in 12/13 (92%) patients. SPET difference images calculated from two independent peri-ictal scans appear to be reproducible and accurately localize the epileptogenic area. While SPET difference images visualize many areas of rCBF change, the quantification of these results along with consideration of injection time improves the diagnostic interpretation of the results.

Adult↗

Measures of cardiovascular autonomic nervous function: agreement, reproducibility, and reference values in middle age and elderly subjects.

AIMS/HYPOTHESIS: Currently, three categories of cardiovascular autonomic nervous function measures are used: classic Ewing-test measures, measures of heart-rate variability (HRV), and measures of baroreflex sensitivity (BRS). Little is known about the agreement between these measures, and reference and reproducibility values for these measures have not been reported within the same group. METHODS: As part of the Hoorn Study, 631 subjects aged 50 to 75 participated in a study of autonomic nervous function. Cardiac cycle duration (RR interval) and continuous finger arterial pressure were measured under three conditions: during spontaneous breathing, during six deep breaths over 1 min, and during an active change in position from lying to standing. From these readings, ten measures of autonomic function were assessed (mean heart rate, three Ewing test measures, five HRV measures and one BRS measure). RESULTS: Regression analysis in a healthy subgroup (n=191) showed sex differences for two of the ten measures and seven measures decreased with age. Therefore, appropriate age-specific and sex-specific reference values were calculated. Reproducibility (n=39) of most measures was moderate, with a reliability coefficient of around 50%. Agreement between the measures of autonomic nervous function varied greatly, between 0% and 87%. The HRV-power ratio measure and the blood pressure changes in the lying-to-standing test showed the lowest agreement with all other measures. CONCLUSION/INTERPRETATION: This study provides age-specific and sex-specific reference values for a wide range of different autonomic function measures in an elderly population. Agreement among the different measures varied widely and reproducibility was only moderate.

Aged↗

F-wave latency serves as the most reproducible measure in nerve conduction studies of diabetic polyneuropathy: multicentre analysis in healthy subjects and patients with diabetic polyneuropathy.

AIMS/HYPOTHESIS: For use in future drug development for diabetic polyneuropathy, we conducted multicentre trials to assess the reproducibility of nerve conduction studies. METHODS: All measurements were repeated twice at a time interval of 1-4 weeks in 132 healthy subjects (63 men) and 172 patients (99 men) with diabetic polyneuropathy. Using a standardised method, 32 centres participated in the study of control subjects and 65, in patients with diabetic polyneuropathy. Motor nerve conduction studies consisted of stimulating the left median and tibial nerves and recording the compound action potential from abductor policis and adductor hallucis for measuring amplitude, terminal latency and minimal F-wave latency. For sensory conduction studies, sensory nerve action potentials were recorded antidromically from the second digit and the posterior aspect of the lateral malleous after distal stimulation of the left median and sural nerves. We also calculated motor conduction velocity, F-wave conduction velocity and sensory conduction velocity. The relative intertrial variation and intraclass correlation coefficient were used as an index of reproducibility. RESULTS: Of all the measurements, F-wave latency yielded the highest intraclass correlation coefficient with the smallest relative intertrial variation for both median and tibial nerves in both groups. CONCLUSION/INTERPRETATION: Median and tibial F-wave latency provide the most reproducible measures for a nerve conduction study, serving as one of the best measures in multicentre drug trials for diabetic polyneuropathies.

Adult↗

Reproducibility of grading scales of pelvic muscle strength: standard versus tampon scale.

The purpose of this study was to demonstrate the reproducibility of an objective scale utilizing a tampon to assess pelvic muscle strength and to compare it to a digital evaluation of muscle strength [1]. Thirty women presenting to the office were enrolled in the study. Their pelvic floor muscle strength was separately assessed by both examiners using both scales. The reproducibility of the scales was then analyzed by Cohen's kappa measure of interrater agreement. The tampon scale was found to have a measure of agreement of 0.76 (excellent interrater agreement if >0.75). In contrast, the digital scale was found to have a measure of agreement of 0.68 (fair agreement if 0.40-0.75). Therefore, the tampon scale is an easy and reproducible approach for assessing pelvic floor muscle strength.

Female↗

Accuracy and reproducibility of simple cross-sectional linear and area measurements of brain structures and their comparison with volume measurements.

Volumetric measurement of brain structure on brain images is regarded as a gold standard, yet is very time consuming. We wondered whether simple linear and area measurements might be as accurate and reproducible. Two observers independently measured the cross-sectional area of the corpus callosum, lentiform and caudate nuclei, thalamus, amygdalas, hippocampi, lateral and third ventricles, and the width of the sylvian and frontal interhemispheric fissures and brain stem on brain MRI of 55 patients using a program written in-house; one observer also measured the volumes of the basal ganglia, amygdalo-hippocampal complex and ventricular system using Analyze, and performed qualitative assessment of four regions (lateral and third ventricles, cortex, and medial temporal lobe) using the Lieberman score. All measures were performed blinded to all other information. Test objects of known size were also imaged with MRI and measured by the two observers using the in-house program. The true sizes of the test objects were measured using engineering calipers by two observers blind to the MRI results. Differences between the two observers using the same measurement method, and one observer using different methods, were calculated. The simple linear and cross-sectional area measurements were rapid (20 min versus 5 h for volumetric); were highly accurate for test-object measurement versus true size; had excellent intraobserver reliability; and, for most brain structures, the simple measures correlated highly significantly with volumetric measures. The simple measures were in general highly reproducible, the difference (as a percentage of the area or width of a region) between the two raters being around 10%, range 0.1%-14.1%, (similar to inter-rater variability in previous studies of volume measurements). The simple linear and area measures are reproducible and correlate well with the measured volumes, and there is a considerable time saving with the former. In circumstances where a large volume of work precludes detailed volume measurement, simple methods are reliable and can be used instead.

Brain↗

Prostate lymphoscintigraphy for sentinel lymph node identification in canines: reproducibility, uptake, and biokinetics depending on different injection strategies.

At present there are neither clinical nor experimental data available on the influence of technical details on the quality and reproducibility of prostate lymphoscintigraphy. Six adult fox hounds received repeated transrectal ultrasound guided intraprostatic injections of a technetium 99m labeled nanocolloid to prove the influence of different techniques of injection (one central injection in both prostate lobes vs two peripheral injections in both lobes) on tracer accumulation in sentinel lymph nodes (SLN) and other organs. The reproducibility of the favored technique was examined and in a last step it was subject to scrutiny following a reduction of the injected volume to 1% of the prostate volume. The number of scintigraphically visualized SLN varied between four and seven. They were located in the region of the internal and external iliac vessels, presacrally, paravesically, and directly paraprostatically. In five of six cases, the localization was reproducible both with the central application of an identical volume as well as with the volume reduced central injection. Tracer accumulation of SLNs and other organs varied enormously. We expect that with the combination of both injection techniques, even with the reduced injection volume, an optimized prostate lymphoscintigraphy will be the outcome.

Animals↗

Comparison of fixed-flexion positioning with fluoroscopic semi-flexed positioning for quantifying radiographic joint-space width in the knee: test-retest reproducibility.

OBJECTIVE: To compare fixed-flexion radiography of the knee with fluoroscopic semi-flexed radiography in terms of the reproducibility of measurements of minimum joint-space width (JSW) in the medial femorotibial joint. METHODS: Posteroanterior radiographs of the right knees of 18 normal volunteers were acquired with the patients standing on an upright fluoroscopy table, the feet externally rotated 10 degrees and the toes touching the vertical table. Knees were positioned and radiographed with two different techniques: (1) semi-flexed positioning under fluoroscopic guidance using a horizontal X-ray beam; and (2) fixed-flexion positioning, with the knees and thighs touching the vertical table, using 10 degrees caudal beam angulation without fluoroscopy. Foot maps were drawn in each case. Subjects were repositioned and radiographed twice using each technique. The posteroanterior beam angle that optimally projected the medial tibia plateau with the patient in the fixed-flexion position was also determined for each subject in a separate examination using fluoroscopy. Ten patients with osteoarthritis were also examined with the fixed-flexion technique using a conventional radiographic unit. Minimum medial joint-space width (JSW) in the medial femorotibial joint was measured manually with a graduated lens and also with a semi-automated computer algorithm. RESULTS: Reproducibility errors (root-mean-square SD) for manual and automated JSW measurement were 0.2 mm and 0.1 mm, respectively, for fluoroscopic semi-flexed positioning in volunteers; 0.3 mm and 0.1 mm, respectively, for fixed-flexion positioning in volunteers; and 0.2 mm and 0.1 mm, respectively, for fixed-flexion positioning in osteoarthritic patients. The optimal beam angle for visualizing the joint space was 9.0 degrees +/-3.6 degrees. CONCLUSION: Fixed-flexion, non-fluoroscopic radiography of the knee can provide reproducible JSW measurement using widely available X-ray equipment. This technique is more feasible for multicenter clinical studies and routine clinical use than are methods that rely on fluoroscopic alignment of the tibial plateau.

Adult↗

Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography.

The purpose of this study was to determine the reliability of new software developed for the analysis of cardiac tomographic data. The algorithm delineates the long axis and defines the basal plane and subsequently generates polar maps to quantitatively and reproducibly assess the size and severity of perfusion defects. The developed technique requires an initial manual estimate of the left ventricular long axis and calculates the volumetric maximum myocardial activity distribution. This surface is used to map three-dimensional tracer accumulation onto a two-dimensional representation (polar map), which is the basis for further processing. The spatial information is used to compute geometrical and mechanical properties of a solid model of the left ventricle including the left heart chamber. A new estimate of the axis is determined from this model, and the previously outlined procedure is repeated together with an automated definition of the valve plane until differences between the polar maps can be neglected. This quantitative analysis software was validated in phantom studies with defects of known masses and in ten data sets from normals and patients with coronary artery disease of various severity. We investigated the reproducibility of the maps with the introduction of a similarity criterion where the ratio of two corresponding polar map elements lies within a 10% interval. The maps were also used to measure intra-and interobserver variability in respect of defect size and severity. In the phantom studies, it was possible to reliably assess mass information over a wide range of defects from 5 to 60 g (slope: 1.02, offset -0.68, r = 0.972). Patient studies revealed a statistically significant increase in the reproducibility of the automatic technique compared with the manual approach: 54%+/-19% (manual) compared with 88%+/-9% (automatic) for observer 1 and 61%+/-20% vs 82%+/-5% for observer 2, respectively. The intervariability analysis showed a significant improvement from 59%+/-14% to 83%+/-7% in similar polar map elements and a significantly improved correlation in the calculation of severity (from r = 0.908 to 0.989) and extent (from r = 0.963 to r = 0.992) of the perfusion defects when the automated procedure was applied. It is concluded that, assuming a constant wall thickness and tissue density, absolute defect mass can be reliably estimated. Furthermore, the proposed software demonstrates a significant improvement in the generation of volumetric polar maps for the quantitative assessment of perfusion defects.

Algorithms↗

Reproducibility of the brain perfusion index for measuring cerebral blood flow using technetium-99m compounds.

We previously developed an alternative method for estimating the brain perfusion index (BPI) using technetium-99m compounds and spectral analysis (SA) for quantification of cerebral blood flow (CBF). In this study, we investigated the reproducibility of the BPI values obtained by SA (BPIS) using a double injection of technetium-99m ethyl cysteinate dimer without any intervention, and compared it with that of the BPI values obtained by graphical analysis (BPIG). The BPIS values in the first (x) and second sessions (y) correlated closely (y=0.921x+0.036; r=0.962; n=64; s.e.e.=0.058 min-1). Although the BPIG values in the first (x) and second sessions (y) also correlated (y=0.942x+0.040; r=0.916; n=64; s.e.e.=0.061 min-1), the correlation coefficient for BPIS was significantly higher than that for BPIG. The reproducibility was dependent on the injection dose ratio of the second session to the first (R). The difference in BPI between the first and second sessions tended to be smaller when 1.5<R<2.5 than when 0<R<1.5 or 2.5<R. These results suggest that the reproducibility of BPIS is satisfactory and that it can be applied to two sequential measurements of CBF using a double injection of 99mTc compounds. When applying our method to such measurements, it is recommended that R is taken as approximately 2.0.

Aged↗

Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT.

High reproducibility is a key requirement for coronary calcium scoring in follow-up examinations. We investigated the inter-examination reproducibility of calcium scoring with retrospectively ECG-gated multisection spiral CT (MSCT). Fifty patients were examined twice with MSCT. Slices were reconstructed with retrospective ECG gating in the diastolic phase with 3-mm slice width and up to 125-ms temporal resolution. We calculated the Agatston score, calcium volume with and without isotropic interpolation, and calcium mass, and derived the mean and median variability. We investigated the change of variability with use of 3-mm non-overlapping and overlapping increments (2, 1.5, 1 mm). Use of overlapping increment results in considerably reduced interscan variability. We observed a minimum mean variability of 12% and a minimum median variability of 9% for the Agatston score. For volume and mass quantification we obtained a minimum mean variability of 7.5% and a minimum median variability of 5%. Multisection spiral CT enables coronary calcium quantification with high reproducibility in follow-up examinations mainly founded on image data with reduced partial-volume errors due to overlapping increment.

Adult↗

Fixed-flexion radiography of the knee provides reproducible joint space width measurements in osteoarthritis.

The validity of a non-fluoroscopic fixed-flexion radiographic acquisition and analysis protocol for measurement of joint space width (JSW) in knee osteoarthritis is determined. A cross-sectional study of 165 patients with documented knee osteoarthritis participating in a multicenter, prospective study of chondroprotective agents was performed. All patients had posteroanterior, weight-bearing, fixed-flexion radiography with 10 degrees caudal beam angulation. A specially designed frame (SynaFlexer) was used to standardize the positioning. Minimum medial and lateral JSW were measured manually and twice by an automated analysis system to determine inter-technique and intra-reader concordance and reliability. A random subsample of 30 patients had repeat knee radiographs 2 weeks apart to estimate short-term reproducibility using automated analysis. Concordance between manual and automated medial JSW measurements was high (ICC=0.90); lateral compartment measurements showed somewhat less concordance (ICC=0.72). There was excellent concordance between repeated automated JSW measurements performed 6 months apart for the medial (ICC=0.94) and lateral (ICC=0.86) compartments. Short-term reproducibility for the subsample of 30 cases with repeat acquisitions demonstrated an average SD of 0.14 mm for medial JSW (CV=4.3%) and 0.23 mm for lateral JSW (CV=4.0%). Fixed-flexion radiography of the knee using a positioning device provides consistent, reliable and reproducible measurement of minimum JSW in knee osteoarthritis without the need for concurrent fluoroscopic guidance.

Aged↗

A multicenter reproducibility study of single-voxel 1H-MRS of the medial temporal lobe.

Proton magnetic resonance spectroscopy ((1)H-MRS) has provided evidence for a reduction of N-acetyl-aspartate (NAA) in the medial temporal lobe (MTL) in cerebral disorders such as Alzheimer's Disease. Within the (1)H-MRS study of the German Research Network on Dementia, we determined the multicenter reproducibility of single-voxel (1)H-MRS of the MTL. At five sites with 1.5T MR systems, single-voxel (1)H spectra from the MTL of an identical healthy subject were measured. The same subject was also examined at one of the sites five times to assess intracenter stability. The protocol included water-suppressed spectra with TE 272 ms and TE 30 ms and unsuppressed spectra for absolute quantification of metabolite concentrations. The intracenter reproducibility of absolute NAA concentration, expressed as coefficient of variation (CV), was 1.8%. CV for the concentrations of creatine (Cr), choline (Cho), and myoinositol (MI) and for the ratios NAA/Cr, NAA/Cho, and MI/NAA varied by 11-16%. Intercenter CV was 3.9% for NAA and were below 10% for all other metabolites and metabolic ratios. Our study demonstrates that quantitative assessment of NAA with single-voxel MRS can be performed with high intercenter reproducibility. This is the basis for applying (1)H-MRS in large-scale early recognition and treatment studies in MTL affecting disorders.

Adult↗

[The reproducibility of multifocal ERG recordings].

PROBLEM: Multifocal electroretinogram recordings (mfERG) can be used to detect a local dysfunction of the retina. In this study we tested both the intrasessional and inter-sessional reproducibility of mfERG amplitudes. METHODS: MfERGs from 6 eyes of 6 normal subjects were recorded on two different days using DTL electrodes. The relative coefficient of variation ( RCV) was used to quantify the amplitude reproducibility. We tested the effect of (a) session (inter- vs. intrasessional), (b) recording duration (7.3 vs. 3.6 min), (c) trace type (hexagon traces vs. ring averages), and (d) amplitude definition (peak-trough analysis vs. scalar product) on RCV. RESULTS: RCV was 6.5+/-0.4% (Mean+/-SEM, n=96) when averaged across all recording conditions and all subjects. The ANOVA showed a significant difference ( p=0.018) between hexagon traces and ring averages. Another significant effect ( p=0.016) occurred for the interaction of (a) and (b). CONCLUSION: MfERGs can be recorded with a high degree of reproducibility even for short recording durations and single hexagon traces. As the factor (a) did not show a significant effect, the new placement of the DTL electrode in the second session does not necessarily increase the retest variability compared to a second recording within the same session.

Artifacts↗

[P-wave signal averaging-ECG: normal values and reproducibility].

Signal averaging techniques are used for detection of low amplitude, high frequency signals in the surface ECG. P-wave signal-averaging has been used to predict the risk for development of atrial tachyarrhythmias in patients with structural heart disease. There is, however, a lack of prospective studies evaluating normal values of the P-wave signal-averaged ECG in healthy individuals. Moreover, day-to-day reproducibility of results of P-wave signal-averaging is not precisely known. Thus, the aim of this study was to determine normal values and reproducibility of time-domain P-wave signal-averaging in a large cohort of healthy volunteers. A commercially available device (MAC 5000, Marquette Hellige) was used for signal-averaging. A vector magnitude was calculated from Frank's orthogonal leads after P-waves were sampled and filtered with a spectral filter using fast fourier transform. We examined 123 volunteers without cardiovascular disease at two occasions. Mean P-wave duration was 114 +/- 13 ms for the overall study population. There was a slight but statistically significant increase in filtered P-wave duration with age (r = 0.32, p < 0.001). All values were reliably reproducible upon the second examination (r = 0.624 to 0.706, p < 0.0001). These results may serve as a future reference to other studies examining patients with structural heart disease.

Adult↗