Iliac anastomotic stenting with a sirolimus-eluting biodegradable poly-L-lactide stent: a preliminary study after 6 weeks.

PURPOSE: To assess technical feasibility and biocompatibility of a new biodegradable sirolimus-eluting poly-L-lactide (PLLA) vascular anastomotic stent. METHODS: A polytetrafluoroethylene bifurcated graft was implanted in 9 pigs through a midline abdominal incision. After transverse graft limb incision, 6 unloaded PLLAs, 6 sirolimus-loaded PLLAs, and 6 unloaded stainless steel (316L) stents were randomly implanted at both iliac anastomotic sites. Stents were deployed with a 6-mm balloon under direct vision without the use of angiography. Prior to sacrifice after 6 weeks, contrast-enhanced computed tomography (CT) was performed to determine patency of the target vessels. Stented segments were surgically explanted and processed for histology to measure the mean luminal diameter and intimal thickness and to assign vascular injury and inflammation scores. RESULTS: No animals were lost during the study period. All stented graft limbs were patent on CT and histology. At the anastomotic sites and iliac arteries, the mean luminal diameter of SIR-PLLA stents (4.11+/-0.15 and 4.08+/-0.13 mm, respectively) were comparable to metal stents (4.23+/-0.35 and 4.21+/-0.26 mm, respectively), but significantly higher compared to unloaded PLLA stents [3.32+/-0.56 mm (p<0.001) and 3.29+/-0.39 mm (p=0.013), respectively]. At the iliac arteries, the mean intimal thickness was significantly lower with SIR-PLLA stents (0.09+/-0.02 mm) compared to unloaded PLLA stents (0.31+/-0.15 mm, p<0.001) and metal stents (0.19+/-0.04 mm, p=0.004). Vascular injury scores demonstrated only mild vascular trauma for all stents (SIR-PLLA: 0.42+/-0.63, PLLA: 0.51+/-0.62, metal: 0.50+/-0.62). Only mild inflammatory reaction was noted around SIR-PLLA stent struts (1.14+/-0.46), which was comparable to metal stents (1.27+/-0.45) but significantly lower than PLLA stents (1.79+/-0.56, p<0.001). CONCLUSION: SIR-PLLA stents showed comparable luminal diameter compared to metal stents, so incorporating sirolimus could reduce the inflammatory and neointimal response to PLLA stents. These findings need to be assessed with longer follow-up to confirm maintenance of efficacy.

Absorbable Implants↗

Unsatisfactory clinical results of meniscal repair using the meniscus arrow.

PURPOSE: The all-inside technique using the Meniscus Arrow (Bionx Implants, Malvern, PA) has become a popular method for repairing meniscal tears. The few published clinical studies have been promising. The present study, with longer follow-up and larger numbers, does not show encouraging results. The clinical efficacy, failure rate, and associated complications of meniscal repair using the Meniscus Arrow with a minimum follow-up of 3 years are described. TYPE OF STUDY: Consecutive case series. METHODS: We studied 60 consecutive meniscal repairs in 57 patients (average age, 27 years) using exclusively the Meniscus Arrow. Follow-up averaged 54 months (range, 36 to 70 months). The anterior cruciate ligament (ACL) was intact in 12 knees (12 repairs), whereas 42 patients (45 repairs) underwent concomitant ACL reconstruction. One patient (2 repairs) had radiofrequency shrinkage of the ACL and another patient (1 repair) underwent concomitant arthroscopic fixation of a tibial eminence fracture. RESULTS: Seventeen of 60 repairs (28%) were documented as failures by repeat arthroscopy or magnetic resonance imaging; 5 of 12 repairs (42%) performed in knees with an intact ACL failed; and 9 of 45 menisci (20%) repaired in conjunction with an ACL reconstruction also failed. The remaining 3 failures occurred in knees with unsuccessful ACL procedures. The type of meniscus tear and the postoperative rehabilitation regimen were also factors that influenced the success rate in this study. Fifteen patients (26%) underwent a second operation because of persistent postoperative symptoms. One patient, whose repair failed, deferred a repeat operation after sustaining a postoperative pulmonary embolism. CONCLUSIONS: Contrary to previously published studies that reported good clinical results, this series revealed a 28% failure rate with significant postoperative complications, such as chondral scoring, fixator breakage, and postoperative joint-line irritation. This study has raised concerns about the continued liberal use of the Bionx Meniscus Arrow, leading the authors to abandon its use for repairing meniscal tears. LEVEL OF EVIDENCE: Level IV.

Absorbable Implants↗

[Biodegradable meniscus fixations: a comparative biomechanical study].

PURPOSE: Numerous new all inside meniscus repair techniques using biodegradable fixation devices have become available in the last years. Few studies have dealt with the biomechanical properties of these implants so far. The aim of this study was to analyze meniscus repairs under cyclic loading conditions for different fixation devices (Meniscus Arrow, Clearfix Meniscal Screw, Meniscal Dart, BioStinger) and to compare them to standard suture techniques. MATERIAL AND METHODS: Eighty meniscus repairs on 27 medial porcine menisci were performed. For biomechanical testing loosening, number of failures, failure modes and failure loads were evaluated under cyclic and maximum loading conditions. Testing was performed on a materials testing machine. RESULTS: During cyclic loading 10 out of 40 (25%) fixation devices failed. A gap appeared between the 2 parts of the meniscus within the first loading cycles. The failure strengths obtained with the 4 meniscus fixation devices did not differ significantly (Meniscus Arrow: 44 N; Clearfix Meniscal Screw: 35 N; Meniscal Dart: 33 N; BioStinger: 54 N). Besides for the BioStinger, the values of the sutures were significantly higher. The use of a stronger suture material (PDS 0) increased the failure load significantly. During maximum loading the fixation devices failed by both pull-out of the head or the tip of the device, except for the BioStinger showing only pull-out of the head. All sutures failed by breakage, except for the PDS 0 horizontal sutures in which 50% of complete tissue failures could be noted. CONCLUSION: This study shows that meniscal fixation devices may fail under repetitive loading conditions. A gap appeared between the meniscal margins within the first loading cycles irrespective of the suture type and fixation device used. Both gapping and failure modes of the fixation devices may be design-specific. The maximum failure loads differed significantly between the bioabsorbable devices and the sutures. Stronger suture materials increased the failure loads significantly. To allow a complete evaluation of new meniscus fixation devices not only biomechanical, but also biological and clinical parameters need to be analyzed in forthcoming studies.

Absorbable Implants↗

Iliac anastomotic stenting with a biodegradable poly-L-lactide stent: a preliminary study after 1 and 6 weeks.

PURPOSE: To assess the technical feasibility, thrombogenicity, and biocompatibility of a new biodegradable poly-L-lactic acid (PLLA) anastomotic stent. METHODS: A polytetrafluoroethylene bifurcated graft was implanted in 17 pigs through a midline abdominal incision. After transverse graft incision, 17 316L stainless steel stents and 17 PLLA stents were randomly implanted at both iliac anastomotic sites and deployed with a 6-mm balloon under direct vision without angiography. Intended follow-up was 1 week in 6 pigs receiving oral acetylsalicylic acid (ASA) and in 7 pigs receiving ASA/clopidogrel; 4 pigs receiving ASA/clopidogrel were followed for 6 weeks. At the end of the study, the segments containing the stents were surgically explanted and processed for histology to measure the mean luminal diameter, intimal thickness, and the vascular injury and inflammation scores. RESULTS: Initial technical success of stent placement was achieved in all animals without rupture of the suture. Two pigs died (unrelated to the stent) at 3 days after operation (1 in groups A and B). At 1 week, all PLLA stents showed thrombotic occlusion with the use of ASA alone. In contrast, all PLLA stents remained patent with concurrent administration of ASA/clopidogrel. All metal stents were patent regardless of the antiplatelet regimen. The mean luminal diameter of patent PLLA stents (4.13+/-0.17 mm) was comparable to metal stents (4.27+/-0.35 mm, p=0.78) at 1 week, but significantly diminished at 6 weeks (3.21+/-0.44 versus 4.19+/-0.18 mm, p=0.005). Histological analysis showed no signs of excessive recoil. PLLA stents induced a higher inflammation score (1.79+/-0.56) and more intimal hyperplasia (0.34+/-0.11 mm) compared to metal stents [1.27+/-0.44 mm (p<0.001) and 0.18+/-0.04 mm (p=0.006), respectively] at 6 weeks. Vascular injury was comparable between PLLA and metal stents. CONCLUSION: Biodegradable PLLA stents showed higher thrombogenicity and reduced patency compared to metal stents during early follow-up. Although ASA and clopidogrel prevented thrombotic occlusion, the increased inflammatory response and neointima formation remain major concerns of PLLA stents. A solution to this problem might be the incorporation of anti-inflammatory drugs into the PLLA stent.

Absorbable Implants↗

Encrustation and strength retention properties of the self-expandable, biodegradable, self-reinforced L-lactide-glycolic acid co-polymer 80:20 spiral urethral stent in vitro.

PURPOSE: Encrustation of urological stents is a clinical problem. The chemical composition and surface properties of the devices have a marked effect on its incidence. The ability of the stent to prevent duct collapse depends on its compression strength, which decreases as degradation progresses. We have developed a new self-reinforced, L-lactide-glycolic acid co-polymer with a molar ratio of 80:20 (SR-PLGA 80/20), that is the SpiroFlow (Bionx Implants, Ltd., Tampere, Finland) stent. We compared the resistance to encrustation of the new stent material to that of 2 temporary metallic stents, Prostakath (Doctors and Engineers, Inc., Copenhagen, Denmark) and Memokath 028 (Engineers and Doctors A/S, Ltd., Kvistgård, Denmark). In addition, mechanical compression properties during degradation were investigated. MATERIALS AND METHODS: For encrustation studies 7 mm segments of the test material of the SR-PLGA 80/20, Prostakath and Memokath stents were incubated in vitro in sterile artificial urine for 4 and 8 weeks, and the SR-PLGA 80/20 also for 12 weeks. After incubation the specimens were fixed in glutaraldehyde, critical point dried and coated with gold in sputter for scanning electron microscope analysis. Analysis was done at 100x magnification in 5 randomly selected areas per sample. Results are presented as a median percent of the whole analyzed area covered by encrustation in each tested material. For compression strength studies 20 mm pieces of manufactured SR-PLGA 80/20 spiral stent wire were similarly incubated in sterile artificial urine for 12 weeks. Measurements were made by compressing the specimens between 2 parallel planes at 2, 4, 6, 8 and 12 weeks. All analyses were made in triplicate. RESULTS: The areas covered by encrustation at 4 weeks were 8.01% for the Memokath, 1.49% for the Prostakath and 0% for the SR-PLGA 80/20. At 8 weeks the percent was 28.4%, 4.1% and 0.12%, respectively, remaining steady at 0.12% in the SR-PLGA 80/20 at 12 weeks. Compression strength of the SR-PLGA stent remained stable up to 6 weeks, after which it decreased rapidly. CONCLUSIONS: The new SR-PLGA 80/20 material is markedly more resistant to encrustation than metallic urethral stent materials and it retains compression strength up to 6 weeks, which is long enough for temporary stenting for most clinical indications in urology. Thus, the new stent is well suited to future clinical use.

Absorbable Implants↗

Periodontal repair in dogs: evaluation of a bioabsorbable space-providing macroporous membrane with recombinant human bone morphogenetic protein-2.

BACKGROUND: Recombinant human bone morphogenetic protein-2 (rhBMP-2) technologies have been shown to significantly support alveolar bone formation. Biomaterial limitations, however, have restricted the biologic potential for onlay indications. The objective of this study was to evaluate regeneration of alveolar bone and periodontal attachment, and biomaterials reaction following surgical implantation of a space-providing, bioabsorbable, macroporous, polyglycolic acid-trimethylene carbonate (PGA-TMC) membrane combined with a rhBMP-2 construct in a discriminating onlay defect model. METHODS: Routine supraalveolar periodontal defects were created at the mandibular premolar teeth in 9 beagle dogs. Contralateral jaw quadrants in subsequent animals were randomly assigned to receive the dome-shaped PGA-TMC (100 to 120 microm pores) membrane with rhBMP-2 (0.2 mg/mL) in a bioresorbable hyaluronan (Hy) carrier or the PGA-TMC membrane with Hy alone (control). The gingival flaps were advanced to submerge the membranes and teeth and sutured. Animals were euthanized at 8 and 24 weeks postsurgery for histologic observations. RESULTS: Jaw quadrants receiving the PGA-TMC membrane alone experienced exposures at various time points throughout the study. Jaw quadrants receiving the PGA-TMC/rhBMP-2 combination remained intact, although one site experienced a late minor exposure. Newly formed alveolar bone approached and became incorporated into the macroporous PGA-TMC membrane in sites receiving rhBMP-2. The PGA-TMC biomaterial was occasionally associated with a limited inflammatory reaction. Residual PGA-TMC could not be observed at 24 weeks postsurgery. Residual Hy could not be observed at any time interval. Regeneration of alveolar bone height (means +/- SD) was significantly increased in sites receiving the PGA-TMC/rhBMP 2 combination compared to control (3.8 +/- 1.3 versus 0.7 +/- 0.5 mm at 8 weeks and 4.6 +/- 0.8 versus 2.1 +/- 0.4 mm at 24 weeks; P < 0.05). Limited cementum regeneration was observed for PGA-TMC/rhBMP-2 and PGA-TMC control sites. Ankylosis compromised regeneration in sites receiving PGA-TMC/rhBMP-2. CONCLUSIONS: The bioabsorbable, space-providing, macroporous PGA-TMC membrane appears to be a compatible biomaterial for bone augmentation procedures. rhBMP-2 significantly enhances alveolar bone augmentation and soft tissue healing when combined with the PGA-TMC membrane.

Absorbable Implants↗

Dimensional stability of the alveolar ridge after implantation of a bioabsorbable bone graft substitute: a radiographic and histomorphometric study in rats.

This study evaluated reconstruction of the alveolar ridge after molar extraction in rats with bioabsorbable bone repair scaffolds. The material was prepared from the unsaturated polyester poly(propylene glycol-co-fumaric acid) (PPF), which may be cured in situ to form a porous scaffold. The intention is to use this material either as a stand-alone bone graft substitute or as an extender to autograft harvested from mandibular reconstruction sites. The bioactivity of the graft substitute was investigated in a rat residual ridge resorption model. PPF bone repair material was injected into the defect site, where it cross-linked in situ in the presence of a hydroxyapatite (HA) filler and effervescent agents. The PPF-based material develops porosity during an in situ cure by generating carbon dioxide during the effervescent reaction of citric acid and sodium bicarbonate. The incorporation of HA promotes osteoconduction within the bone repair scaffold. In this study, bioactivity of the porous scaffold was evaluated as a function of HA particle size (micrometer-sized vs nanometer-sized particles). The maxillary or mandibular molars on the right side were extracted from 96 adult Sprague-Dawley rats. A 2-mm round bur was used to create a uniform trench defect measuring 2 mm in diameter, 2 mm in depth, and 4 mm in length at each extraction site. The defect site was (1) treated with PPF bone repair material containing nanometer-sized HA, (2) treated with PPF material containing micrometer-sized HA, (3) treated with demineralized freeze-dried bone allograft, or (4) left untreated. Rats were sacrificed at 2, 4, 7, and 12 weeks postoperative. Resorption of the residual alveolar ridge was assessed by radiographic outcomes. Bone ingrowth through the defect site was measured by histomorphometric outcomes. Mandibular and maxillary ridge heights increased for all treatments used in this study. There were no clinical indications that addition of either of the PPF bone repair materials retarded hard- or soft-tissue healing of the extraction sites. Although not statistically significant, the mandibular defects treated with PPF containing nanometer-sized HA healed at a faster rate as determined by ridge height and new bone formation measurements when compared with the other treatments. These findings suggest the feasibility of using PPF bone graft substitutes for oral-maxillofacial applications.

Absorbable Implants↗

Ultrasound biomicroscopy and intraocular-pressure-lowering mechanisms of deep sclerectomy with reticulated hyaluronic acid implant.

PURPOSE: To evaluate the anatomic characteristics and intraocular pressure (IOP) lowering mechanisms of deep sclerectomy with reticulated hyaluronic acid implant (DS with RHAI) using ultrasound biomicroscopy (UBM). SETTING: Eye Clinic, Department of Neurological and Vision Sciences, University of Verona, Verona, Italy. METHODS: Thirty patients with primary open-angle glaucoma not controlled by medical therapy had DS with RHAI in 1 eye. A complete ocular examination and UBM study were performed 1, 3, 6, and 12 months postoperatively and thereafter at 6 month intervals. Eleven parameters were evaluated, the most important of which were IOP, surgical success in lowering IOP to 21 mm Hg or less with or without additional medical therapy, UBM appearance of the site of DS with RHAI, size of the decompression space, presence of a filtering bleb and supraciliary hypoechoic area, and scleral reflectivity around the decompression space. RESULTS: After a mean follow-up of 11.4 months +/- 4.7 (SD), the mean percentage reduction in IOP compared to preoperatively was 38% (from 26 +/- 4.5 mm Hg to 16.2 +/- 3.8 mm Hg; P =.0001). Twenty-four patients (80%) had an IOP less than 21 mm Hg; however, 7 of these eyes (23%) required additional IOP-lowering medical therapy. The operation failed in 6 patients (20%) despite additional therapy. Ultrasound biomicroscopy revealed a reduction in the size of the decompression space from 6 months postoperatively and its disappearance in 2 cases. The difference in size at the last follow-up and at 1 month postoperatively (maximum length 2.41 +/- 1.02 mm versus 3.53 +/- 0.51 mm) was significant (P =.0001). At the last examination, a filtering bleb was present in 18 patients (60%), a supraciliary hypoechoic area in 18 (60%), and hyporeflectivity of the scleral tissue around the decompression space in 14 (47%). These 3 UBM characteristics were detected singly and in various combinations. The simultaneous presence of all 3 characteristics in the same eye correlated significantly with a higher surgical success rate (P =.004). CONCLUSIONS: Ultrasound biomicroscopy showed that filtering bleb formation was frequent in eyes having DS with RHAI but that it was not the only surgically induced IOP-lowering mechanism. Increased uveoscleral and transscleral filtration may be equally important.

Absorbable Implants↗

[Air permeable diaphyseal obturators: efficacity of femoral cementing and prevention of associated cardiovascular disorders].

PURPOSE OF THE STUDY: Insertion of cement plugs into the femoral shaft has become an essential part of total hip arthroplasty procedures. The goal is to achieve secure cementing of the femoral component, but the pressure induced can cause serious problems. The purpose of this study was to determine the effect of a flexible bioabsorbable cement restrictor with decompression valves on cementing efficacy and to determine the effect of inserting the restrictor then the cement plug into the femoral shaft on respiratory functions. MATERIAL AND METHODS: The restrictor was implanted in 108 patients undergoing first-intention total hip arthroplasty. The canal was prepared and calibrated before inserting the restrictor at a depth estimated at preoperative planning to be 10 to 20 mm below the tip of the femoral stem. The efficacy of the restrictor was assessed using radiographic criteria for the quality of the cement sheath and its position relative to the femoral stem. Oxygen saturation of arterial blood and end-expiration PCO2 were measured at first incision, at insertion of the restrictor, at insertion of the cement plug, and at insertion of the femoral stem. RESULTS: The relative position of the restrictor was measured on postoperative x-rays at less than 20 mm in 75% of the patients, at 20-40 mm in 13% and at more than 40 mm in 12%. No cement leakage through the restrictor was identified on postoperative x-rays. The quality of the cement sheath was satisfactory in 71% of the patients (77 procedures), fair in 20% (22 procedures) and poor in 8% (9 procedures). For a first group of patients operated on under spinal anesthesia and optional oxygen delivered with a face mask, there was no significant difference in arterial blood oxygen saturation before the procedure and during the four explored operative times. Conversely, in a second group of patients who had general anesthesia without oxygen enrichment of the initial oxygen-nitrogen protoxide gas mixture, arterial blood oxygen saturation during the four operative times was statistically different from the preoperative value. The same observation was made for end-expiratory PCO2. DISCUSSION: The retrictor's decompression valves did not allow cement leakage beyond the restrictor. The risk of restrictor migration after insertion and after the increased pressure due to cement plug insertion was not increased and was found to be less than rates reported in the literature. In the patients who had general anesthesia, blood gases showed a minimal, but significant, decrease during the operative times susceptible to induce increased intramedullary pressure. In patients who had a non-cemented acetabular insert, use of the pressure-valve cement restrictor appeared to stabilize these parameters.

Absorbable Implants↗

Bioabsorbable fixation devices in trauma and bone surgery: current clinical standing.

Bioabsorbable fixation devices are increasingly used in trauma, orthopedic and craniomaxillofacial surgery. The devices are essentially made of polylactic acid and/or polyglycolic acid polymers. Ultra-high-strength implants are manufactured from such polymers using self-reinforcing techniques. Implants are available for stabilization of fractures, osteotomies, bone grafts and fusions, as well as for reattachment of ligaments, tendons, meniscal tears and other soft tissue structures. As these implants are completely absorbed, the need for a removal operation is overcome and long-term interference with tendons, nerves and the growing skeleton is avoided. The risk of implant-associated stress shielding, peri-implant osteoporosis and infections is reduced. Implants do not interfere with clinical imaging. Current clinical use of bioabsorbable devices is reviewed.

Absorbable Implants↗

Simplified MRI sequences for postoperative control of hamstring anterior cruciate ligament reconstruction.

INTRODUCTION: Usually, standard radiographs are used for postoperative quality follow-up after ACL reconstruction. However, with the use of hamstring grafts and bioabsorbable implants, accurate assessment of the tunnel and implant position is impossible. The graft and its relation to anatomical landmarks cannot be evaluated directly. MRI is an alternative to radiography, permitting direct graft visualization and 3-dimensional assessment of the tunnel position, but it is expensive and time consuming for routine use. The aim of this study was to develop a simplified MRI protocol and to evaluate it for routine postoperative quality follow-up after ACL reconstruction. MATERIALS AND METHODS: Various scanning protocols were tested in a series of 105 patients and evaluated for image sharpness, clarity of the structures, susceptibility to artefacts, applicability regarding precise analysis of graft and tunnel position, and time consumption. One simplified specific scan protocol was then defined and applied in a series of 60 consecutive patients after hamstring ACL replacement. The position of the femoral and tibial tunnels was measured in the sagittal, coronal and axial sections and classified according to Harner (femoral) and Stäubli (tibial). Impingement of the graft in the intercondylar roof was analysed according to Howell. The position of the bioabsorbable interference screws was assessed. RESULTS: Scan protocol: T2-weighted gradient-echo sequences (GRE) with TR 246 ms, TE 11 ms, flip angle 25 degrees, 2 mm sections and a 256 x 256 matrix yielded the best image quality of tendon grafts and bone tunnels with tolerable time consumption (average scanning time per patient 1 min 40 s). Altogether 8-16 sections were obtained for every patient. Tunnel placement: 46/60 (77%) of the femoral tunnels were in zone 4, 13/60 (21%) at the border of zones 3 to 4, 1/60 (2%) in zone 3 in the sagittal plane (Harner). The femoral tunnels in the axial plane were at 10:30 o'clock in 32/60 (53%), at 11:00 o'clock at 24/60 (40%) and at 10:00 o'clock in 4/60 (4%) patients. The mean distance of the anterior border of the tibial tunnel from the anterior cortex was 39% (+/- 4.9%) related to the total sagittal diameter of the tibia. There was no graft impingement. The position of the interference screws was anterior to the grafts in all cases. CONCLUSION: Simplified MRI sequences can be used for postoperative quality follow-up after ACL replacement and are an alternative to standard radiographs giving more specific and precise information regarding tunnel position and screw placement. Analyzing the bone tunnels in a series of 60 patients demonstrated that correct assessment of tunnel placement after arthroscopic ACL reconstruction is feasible using this simplified MRI technique.

Absorbable Implants↗

The acetabular component in total hip arthroplasty. Evaluation of different fixation principles.

Initial stability is necessary for permanent fixation of acetabular cups. Biologic reactions to submicron particles such as localized bone resorption may lead to implant failure. The aim of the study was to evaluate different fixation principles of acetabular components. Four randomized studies and one case-control study were performed to evaluate different bone cements, different cup designs, use of ceramic coating or not, different type of screws and the need of additional screw fixation or not. Radiostereometry (RSA) makes it possible to analyze small translations and rotations of implants with a high accuracy. This method is suitable for evaluation of early stability and was used in four of the studies. Clinical and radiological follow-up were performed regularly. The cements were tested in the laboratory. 30 patients (mean age 71 years, range: 63-76) received total hip arthroplasties and were randomised to fixation with Boneloc (14) or Palacos cum gentamicin (16) bone cement. The curing temperature was 23 degrees lower for the Boneloc cement but the tensile strength was reduced and the elastic modulus was lower compared to Palacos. The proximal cup migration was greater in the Boneloc group up to 12 months (p 0.04) and these cups migrated medially in contrast to a small lateral migration seen in the Palacos group (p 0.04). Radiolucencies were more pronounced in the Boneloc group at 12 months (p 0.04). 155 patients (171 hips, mean age 50 years, range: 24-64) received uncemented hip arthroplasties. 84 hips were randomised to the PCA and 87 to the Harris-Galante I designs. The 10-year survival rates were 85% for the PCA and 99% for the Harris-Galante I cups (revision as end-point). The wear and clinical results did not differ. 43 patients (mean age 60 years, range 44-68) received uncemented porous cups with a titanium mesh in pure titanium (Harris-Galante II) and were randomised to additional fixation with either biodegradable screws (23, poly-L-lactic acid, PLLA) or screws made of titanium alloy (20). Increased proximal and medial-lateral translations (p 0.02, 0.04) but less rotation around the longitudinal axis (p 0.04) were seen in the PLLA group up to 2 years. There were also more pronounced radiolucencies anteriorly in this group at 2 years. The clinical results did not differ. 23 uncemented porous cups (Harris-Galante II) with hydroxyapatite-tricalciumphosphate coating (HA/TCP) were pair-wise matched to uncoated cups. Up to 2 years, decreased rotations around the horizontal axis were recorded in the HA/TCP-coated cups. Central postoperative gaps were more frequently seen in the HA/TCP group (p < 0.01), but at 2 years radiolucencies were more pronounced in the uncoated group (p < 0.01). The wear and clinical results did not differ. 62 patients (64 hips, mean age 56 years, range: 32-75) were randomized to porous Trilogy cups with (30) and without (34) cluster holes for additional screw fixation. Up to 2 years there were no differences in migration, wear, radiographic findings or clinical results. In conclusion Boneloc cement was associated with poor fixation due to inferior mechanical properties. The PLLA screws did not provide sufficient stability. Unacceptably high failure rates were recorded for the PCA cup. HA/TCP coating improved the fixation and the interface of porous cups. HA/TCP coated porous cups can be fixed without adjunctive screw fixation.

Absorbable Implants↗

A pilot study to evaluate the effectiveness of small intestinal submucosa used to repair spinal ligaments in the goat.

BACKGROUND CONTEXT: Destabilization of the lumbar spine results from sacrifice of the anterior longitudinal ligament and disc when removed for graft or cage placement. In a similar fashion, transection of the interspinous ligament during surgical approaches to the posterior spine may result in segmental instability. Such instability can cause abnormal motion or implant migration resulting in a higher incidence of pseudarthrosis. Small intestinal submucosa (SIS) is a naturally occurring extracellular collagen-based matrix, which is derived from porcine small intestine. SIS contains cytokines and growth factors and has been shown to act as a resorbable scaffold in vivo that promotes host soft tissue regeneration with little scar tissue formation. SIS can be manufactured in laminated sheets of various sizes and thicknesses for different indications. Successful applications of SIS in animals have included dural substitution, rotator cuff repair, vessel repair, abdominal and bladder wall repair, and others. However, SIS has not been investigated to determine its ability to facilitate regeneration of spinal ligaments. PURPOSE: The purpose of this pilot study was to evaluate the efficacy of SIS as a barrier to prevent interbody device migration, and to act as a scaffold for regeneration of the anterior longitudinal ligament (ALL) and posterior interspinous ligament (PISL) in a goat model. STUDY DESIGN/SETTING: The thoracolumbar spine of the goat was exposed surgically. After resection and removal of the ALL or PISL at alternating levels, either SIS was placed or no treatment was administered. New ligament formation and SIS resorption were monitored over a 12-week period. OUTCOME MEASURES: Plain film radiographs and histomorphometry were used to assess the progress of healing over a 12-week time period. METHODS: Four skeletally mature nubian-alpine crossbred goats were used in this study. Under general anesthesia, each T10 to L5 motion segment was exposed surgically. Both anterolateral and posterior approaches were performed simultaneously at each level. Anteriorly, alternating levels received either 1) anterior discectomy, sacrifice of ALL and placement of SIS (SIS group); 2) anterior discectomy, sacrifice of ALL and no SIS (surgical control group) or 3) no surgical intervention (nonoperative group). A solid interbody spacer was placed into the disc space after discectomy to deter spontaneous anterior interbody fusion. Posteriorly, alternating levels were treated with either 1) sacrifice of the PISL with placement of SIS (SIS group); 2) sacrifice of PISL and no SIS (surgical control group) or 3) no surgical intervention (nonoperative group). The SIS was secured to the adjacent superior and inferior spinous processes to create a tension-band effect. Animals were radiographed immediately postoperatively to confirm placement of interbody spacers and anchors and to serve as a baseline for monitoring interbody spacer positioning. After surgery, all animals were allowed unrestricted motion for 12 weeks. At the end of the 12-week period, animals were radiographed and euthanized. The lumbar spine was harvested en bloc and processed for decalcified histologic evaluation. The dorsal and ventral aspects of each motion segment were analyzed for signs of inflammation and scar tissue formation, residual SIS and regenerated ALL or PISL. RESULTS: All animals tolerated the surgical procedure well, and there were no intraoperative or anesthesia-related complications. Twelve-week radiographs showed some evidence of ventral migration of the interbody spacers in several animals. Fifty percent (two of four) of spacers in surgical control group levels had migrated more than 10 mm (resulting in complete migration out of the disc space), whereas no spacers migrated completely out of levels with SIS placed. Gross analysis at necropsy indicated iatrogenic scar formation at operated levels, the degree of which was not different from surgical control group to SIS levels. Histologic evaluation of areas where the ALL had been removed indicated formation of organized fibrilar collagenous tissue that spanned the disc space at some levels where the SIS was placed. In some cases, the newly formed tissue was approximately the thickness of the ALL at the nonoperative group levels. The newly formed collagenous tissue was accompanied by sparse focal areas of inflammation, with small fragments of residual SIS at some levels. At surgical control group levels, there was a varying degree of connective tissue that ranged from moderately organized to randomly oriented with no significant signs of inflammation. Similarly, histologic analysis of some levels where SIS was placed posteriorly showed formation of organized collagenous tissues where the PISL had been removed. CONCLUSIONS: In this model, the SIS patch was sufficient to prevent acute ventral migration of interbody spacers from the disc space. The extent of long-term healing and new tissue formation in the SIS group indicates that it may be efficacious as a reparative intervention for transected ligaments in the spine. Most SIS specimens showed formation of organized collagenous tissue, indicating a long-term potential for ligament formation. However, in this model, 12 weeks of postoperative healing is insufficient to assess the full potential of SIS as a spinal ligament repair. Further research that follows the healing process to a longer time point postoperatively may be necessary to fully understand the potential of SIS as a resorbable scaffold for tissue replacement.

Absorbable Implants↗

[Adjuvants to nonpenetrating surgery: drains and implants].

The nonpenetrating filtering procedure requires a functioning intrascleral space. This space is created after a careful dissection and resection of the deep scleral flap. In order to prevent a collapse of the remaining superficial flap that forms the roof of the intrascleral cavity, a space maintainer is usually inserted at this stage of surgery. Two different types of drainage devices are used: absorbable and nonabsorbable implants. The first type is currently made of porcine collagen material that is slowly absorbed over time, whereas the second is usually made of nondegradable materials that permanently remain in the scleral bed. No significant differences in the surgical technique can be found between the two types of implant. The long-term results are fairly similar for both of them, the absorbable implant being slightly more advantageous.

Dissection↗

Resorbable plate fixation in pediatric craniofacial surgery: long-term outcome.

OBJECTIVE: To determine the long-term efficacy of resorbable plate fixation in pediatric patients undergoing craniofacial surgery for congenital anomalies, traumatic deformities, or skull base tumors. DESIGN: Retrospective case review. MATERIALS AND METHODS: Medical records of 57 consecutive cases using resorbable plates and screws for craniofacial fixation in patients younger than 18 years were analyzed. MAIN OUTCOME MEASURES: The status of bone healing postoperatively (anatomical union, malunion, delayed union, or nonunion) and any complications or adverse effects (hardware visibility or palpability, plate extrusion, or infection) were noted. RESULTS: In midfacial and upper face procedures (54 patients) anatomical union and uncomplicated bone healing occurred in 52 (96%) of the patients. In this same group, complications (plate extrusion) occurred in 2 patients (3.7%) and were resolved using conservative treatment without untoward sequelae. These outcomes are comparable to results using metal osteosynthesis in similar situations. Costs of resorbable hardware are similar to existing metal fixation systems. CONCLUSIONS: Our data support the use of bioresorbable plate fixation in pediatric craniofacial surgery as a means of avoiding the potential and well-documented problems with rigid metal fixation. Indications include fractures and segmental repositioning in low-stress non-load-bearing areas of the middle and upper craniofacial skeleton. Although there is an initial learning curve in using this technology, we believe the benefits are well worth the effort and represent a major advance in pediatric craniofacial surgery.

Absorbable Implants↗

Periosteal readhesion after brow-lift in New Zealand white rabbits.

OBJECTIVES: To define the postoperative time interval required for elevated periosteum to readhere to the skull and regain its preoperative strength, and to evaluate whether fixation of the periosteum affects this interval or the strength of postoperative readhesion. DESIGN: Prospective analysis of variance and covariance with repeated measures. SUBJECTS: Thirty-six New Zealand white rabbits, each serving as its own control. INTERVENTIONS: Subperiosteal elevation was performed on one side of the skull, leaving the contralateral periosteum untouched. The periosteum in half of the subjects was lifted and fixed to a resorbable screw, with the comparison group undergoing subperiosteal elevation only, without lifting and fixation. Several adhesion characteristics were subsequently examined at postoperative weeks 1, 3, 5, 7, 8, 9, 10, 11, and 12. Half of the subjects were assessed histologically to determine attachment of periosteum onto underlying bone. The other half underwent analysis of periosteal readhesion strength. RESULTS: The 3 independent measures of periosteal adherence to the skull all lacked significant differences between sides after the first postoperative week. Blinded histologic analysis showed no evidence of ongoing periosteal healing and demonstrated no difference between operated-on and nonoperated-on sides. Analysis of periosteal stiffness (P =.76) and energy density (P =.74) also demonstrated no significant differences between sides. CONCLUSIONS: Periosteal readhesion after surgical elevation is virtually complete by the seventh postoperative day. In addition, tension secondary to periosteal elevation with suspension has no influence on postoperative healing. These findings will contribute to the debate regarding the most appropriate brow-lift fixation technique.

Absorbable Implants↗

Endoscopic forehead-lift using a bioabsorbable fixation device.

Endoscopic brow-lift is the method of upper face rejuvenation preferred by facial plastic surgeons and patients alike. The technique has undergone significant scrutiny regarding methods of fixation. Many techniques have been described, including external bolster dressings, tissue adhesives, Kirschner-wire fixation, cortical tunnels and troughs, and permanent or temporary screw and plate fixation. Many of these techniques are associated with postoperative alopecia, poor reliability, possible intracranial complications, and palpable hardware. Thus, the search for a safe, effective, reliable, and straightforward procedure continues. We describe our experience with an easy-to-insert bioabsorbable device that is fixed to the calvaria and provides multipoint fixation to the soft tissue.

Absorbable Implants↗

Safety and efficacy of midface-lifts with an absorbable soft tissue suspension device.

OBJECTIVE: To evaluate the safety and efficacy of midface-lifting using an absorbable suspension device (Endotine ST). DESIGN: Prospective cohort of 10 consecutive adult female patients seen in a private practice who underwent isolated midface-lift without accompanying eyelid surgery or volume augmentation procedures in the setting of an accredited ambulatory surgical center. All patients underwent endoscopic-assisted midface-lifts with general anesthesia or intravenous sedation. Subperiosteal dissections of the midface were performed with fixation of the Endotine ST device to temporalis fascia. Objective and subjective criteria were recorded and photodocumented during the postoperative period at 1 week and 1, 3, and 6 months. Patient characteristics of erythema, tenderness, and pain were recorded with a visual analog scale. The patients and surgeon rated changes from the baseline condition and overall satisfaction with the procedure at 1, 3, and 6 months. RESULTS: All 10 patients completed the 6-month postoperative follow-up. Nine of the 10 patients had significant improvements in their aesthetic outcome. The most common objective symptom of malar sensitivity diminished significantly between the 1- and 3-month visits. One patient experienced a temporary paresis of the zygomaticofacial nerve that resolved at 3 months. There were no major complications of infection, extrusion, skin irregularities, or device removals. CONCLUSIONS: Midface-lifting with the Endotine ST device provided significant elevation of the malar fat pad with improvement in facial contour. Safety of this surgical technique was comparable to that of midface-lifts in other published studies. Patient acceptance of the midface-lift using the Endotine ST device was favorable. Temporary tenderness over the malar area can be expected during the early postoperative period.

Absorbable Implants↗