PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Automation, Laboratory”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Rapid detection of significant bacteriuria by use of an automated Limulus amoebocyte lysate assay.

Previous studies have demonstrated that significant gram-negative bacteriuria can be detected by using the Limulus amoebocyte lysate test. A series of 580 urine specimens were tested in parallel with the automated MS-2 (Abbott Laboratories) assay and with quantitative urine bacterial cultures. The overall ability of the MS-2 Limulus amoebocyte lysate test to correctly classify urine specimens as containing either greater than or equal to 10(5) organisms or less than 10(5) organisms per ml during a 20-min test period was 92.6%.

Bacteria↗

Rapid differentiation of closely related Candida species and strains by pyrolysis-mass spectrometry and Fourier transform-infrared spectroscopy.

Two rapid spectroscopic approaches for whole-organism fingerprinting of pyrolysis-mass spectrometry (PyMS) and Fourier transform-infrared spectroscopy (FT-IR) were used to analyze a group of 29 clinical and reference Candida isolates. These strains had been identified by conventional means as belonging to one of the three species Candida albicans, C. dubliniensis (previously reported as atypical C. albicans), and C. stellatoidea (which is also closely related to C. albicans). To observe the relationships of the 29 isolates as judged by PyMS and FT-IR, the spectral data were clustered by discriminant analysis. On visual inspection of the cluster analyses from both methods, three distinct clusters, which were discrete for each of the Candida species, could be seen. Moreover, these phenetic classifications were found to be very similar to those obtained by genotypic studies which examined the HinfI restriction enzyme digestion patterns of genomic DNA and by use of the 27A C. albicans-specific probe. Both spectroscopic techniques are rapid (typically, 2 min for PyMS and 10 s for FT-IR) and were shown to be capable of successfully discriminating between closely related isolates of C. albicans, C. dubliniensis, and C. stellatoidea. We believe that these whole-organism fingerprinting methods could provide opportunities for automation in clinical microbial laboratories, improving turnaround times and the use of resources.

Candida↗

Three decades of research on computer applications in health care: medical informatics support at the Agency for Healthcare Research and Quality.

The Agency for Healthcare Research and Quality and its predecessor organizations-collectively referred to here as AHRQ-have a productive history of funding research and development in the field of medical informatics, with grant investments since 1968 totaling $107 million. Many computerized interventions that are commonplace today, such as drug interaction alerts, had their genesis in early AHRQ initiatives. This review provides a historical perspective on AHRQ investment in medical informatics research. It shows that grants provided by AHRQ resulted in achievements that include advancing automation in the clinical laboratory and radiology, assisting in technology development (computer languages, software, and hardware), evaluating the effectiveness of computer-based medical information systems, facilitating the evolution of computer-aided decision making, promoting computer-initiated quality assurance programs, backing the formation and application of comprehensive data banks, enhancing the management of specific conditions such as HIV infection, and supporting health data coding and standards initiatives. Other federal agencies and private organizations have also supported research in medical informatics, some earlier and to a greater degree than AHRQ. The results and relative roles of these related efforts are beyond the scope of this review.

Databases, Factual↗

Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA).

This brief note addresses the historical background of the invention of the enzyme immunoassay (EIA) and enzyme-linked immunosorbent assay (ELISA). These assays were developed independently and simultaneously by the research group of Peter Perlmann and Eva Engvall at Stockholm University in Sweden and by the research group of Anton Schuurs and Bauke van Weemen in The Netherlands. Today, fully automated instruments in medical laboratories around the world use the immunoassay principle with an enzyme as the reporter label for routine measurements of innumerable analytes in patient samples. The impact of EIA/ELISA is reflected in the overwhelmingly large number of times it has appeared as a keyword in the literature since the 1970s. Clinicians and their patients, medical laboratories, in vitro diagnostics manufacturers, and worldwide healthcare systems owe much to these four inventors.

Animals↗

Performance evaluation and cross-reactivity from insulin analogs with the ARCHITECT insulin assay.

BACKGROUND: Insulin measurement is used for the diagnosis of hypoglycemia and for insulin pharmacokinetic evaluations. We assessed the analytical and clinical performance of the ARCHITECT insulin assay, a chemiluminescent immunoassay recently introduced for the ARCHITECT i2000 fully automated immunoassay analyzer (Abbott Laboratories). We also tested whether major insulin analogs cross-reacted with the immunoassay reagents. METHODS: We used Clinical and Laboratory Standards Institute protocols to assess the analytical performance of the ARCHITECT insulin assay and compared its accuracy with that of the E-test TOSOH II (IRI) from TOSOH Corporation. We used 3 recombinant insulin analogs (lispro, aspart, and glargine) to evaluate the cross-reactivity of insulin analogs with the ARCHITECT immunoassay reagent. RESULTS: The total CV for the ARCHITECT assay was < 5%. Correlation between the ARCHITECT insulin assay and the E-test TOSOH II (IRI) was satisfactory in the measured range, but we detected a slope deviation between the assays. The ARCHITECT insulin assay showed low cross-reactivity to the insulin analog aspart, whereas it detected the other insulin analogs, lispro and glargine, in concentrations as high as the theoretical concentrations. CONCLUSIONS: The ARCHITECT insulin assay showed favorable basic performance, including reproducibility, dilution linearity, detection limit, and effects of interfering substances. When interpreting results, clinicians and laboratory pathologists should be aware of the cross-reactivity of the ARCHITECT and other immunoassays to specific insulin analogs prescribed to diabetes patients.

Autoanalysis↗

Routine differential diagnosis of proteinurias by capillary electrophoresis.

Capillary electrophoresis is a relatively new analytical technique that begins to have an impact on both routine and research in clinical laboratories. Recently, a fully automated system has become commercially available (Paragon CZE 2000, Beckman, USA) for the analysis of human serum proteins. Urine protein analysis, on the other hand, is currently accomplished by electrophoresis of concentrated urine specimens. The method is used to distinguish the glomerular from the tubular proteinuria and for the identification of Bence-Jones proteins. The procedure is labor-intensive and technically demanding. We developed a technique for the serum capillary electrophoresis instrument that can also be applied routinely to the differential diagnosis of proteinurias. Overriding the programmed dilution step of the instrument, we were able to distinguish different types of proteinurias without concentration of specimens with a total protein content of 150-200 mg/l as determined by sulfosalicylic acid. The different electrophoretic patterns obtained by the capillary electrophoresis system for various specimens correlated well with established techniques (Hydragel Proteinurie Kit, Sebia, France). The method is applicable for routine analysis of urinary proteins. It is reliable, less expensive and faster than the conventional methods (electrophoretic or immunonephelometric) used today for the differentiation of proteinurias, and it can be used as a quick screening test.

Albuminuria↗

Use of specific indicators to detect warfarin-related adverse events.

PURPOSE: The use of specific indicators, or "triggers," to identify adverse drug events (ADEs) associated with warfarin therapy is described. SUMMARY: Automated triggers provided by laboratory and pharmacy data were used to identify potential ADEs associated with warfarin therapy among patients treated in the emergency room or admitted to six community hospitals between July 2002 and December 2003. The triggers consisted of an International Normalized Ratio (INR) of greater than 3.0 and pharmacy orders for vitamin K. Pharmacists reviewed the triggers monthly for clinical determination of ADEs during preintervention and postintervention periods. Interventions consisted of staff education and real-time adjustments in therapy. A 39% overall reduction in ADEs occurred between the preintervention and postintervention periods. Harmful ADEs declined by 70%. CONCLUSION: INRs of greater than 3.0 and vitamin K administration appeared to be reliable indicators of warfarin-associated ADEs, and detection with these indicators appeared to reduce ADEs when combined with appropriate interventions.

Aged↗

Behavioral and clinical factors associated with depression among individuals with diabetes.

OBJECTIVE: The goal of this study was to determine the behavioral and clinical characteristics of diabetes that are associated with depression after controlling for potentially confounding variables. RESEARCH DESIGN AND METHODS: A population-based mail survey was sent to patients with diabetes from nine primary care clinics of a health maintenance organization. The Patient Health Questionnaire was used to diagnose depression, and automated diagnostic, pharmacy, and laboratory data were used to measure diabetes treatment intensity, HbA(1c) levels, and diabetes complications. RESULTS: Independent factors that were associated with a significantly higher likelihood of meeting criteria for major depression included younger age, female sex, less education, being unmarried, BMI > or = >30 kg/m(2), smoking, higher nondiabetic medical comorbidity, higher numbers of diabetes complications in men, treatment with insulin, and higher HbA(1c) levels in patients <65 years of age. Independent factors associated with a significantly higher likelihood of meeting criteria for minor depression included younger age, less education, non-Caucasian status, BMI > or = 30 kg/m(2), smoking, longer duration of diabetes, and a higher number of complications in older (> or = 65 years) patients. CONCLUSIONS: Smoking and obesity were associated with a higher likelihood of meeting criteria for major and minor depression. Diabetes complications and elevated HbA(1c) were associated with major depression among demographic subgroups: complications among men and HbA(1c) among individuals <65 years of age. Older patients with a higher number of complications had an increased likelihood of minor depression.

Age Factors↗

Unexpected hypoglycemia in a critically ill patient.

Administration of the wrong medication is a serious and understudied problem. Because physicians are not directly involved in the drug administration process, they tend to overlook the possibility of adverse drug events and medication errors in their differential diagnoses of patient illnesses or acute deterioration. This article analyzes the case of a patient with iatrogenic hypoglycemia due to administration of the wrong medication: Insulin instead of heparin was used to flush the patient's arterial line. In addition to assessing the results of the institution's "root-cause analysis" of the factors contributing to this particular adverse event and the institution's response, this article reviews the literature on preventing medication errors. Key strategies that might have been helpful in this case include using checklists for common emergency conditions (such as altered level of consciousness) and automated paging for "panic laboratory values," as well as instituting protocols for medication administration. Changing the system of administering medications by bar coding drugs, with checks of the medication, patient, and provider, could have prevented this accident. Finally, organizations need to strive for a "culture of safety" by providing opportunities to discuss errors and adverse events in constructive, supportive environments and by resisting pressure to find a scapegoat.

Aged↗

Automation: triumph or trap?

Automation, a hot topic in the laboratory world today, can be a very expensive option. Those who are considering implementing automation can save time and money by examining the issues from the standpoint of an industrial/manufacturing engineer. The engineer not only asks what problems will be solved by automation, but what problems will be created. This article discusses questions that must be asked and answered to ensure that automation efforts will yield real and substantial payoffs.

Capital Expenditures↗