PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Compressive Strength”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Enhancement of physical properties of resin restorative materials by laser polymerization.

A study was conducted to compare the compressive strength, diametral tensile strength, transverse flexural strength, and flexural modulus of a microfilled and a small particle composite resin restorative material following argon laser and conventional visible light polymerization techniques. All physical properties examined in this study were enhanced by laser polymerization. The diametral tensile strength of both types of restorative materials was significantly greater following laser polymerization, as were the transverse flexural strength and the flexural modulus of the microfilled resin restorative material. Additionally, these results were obtained with a laser polymerization time that was one-fourth that used for visible light activation. It was concluded that the argon laser is a potentially advantageous means of initiating the polymerization of dental composite resin restorations.

Acrylic Resins↗

Failure load of thoracic vertebrae correlates with lumbar bone mineral density measured by DXA.

Fractures of the thoracic spine account for a large portion of vertebral fractures in the elderly, yet noninvasive measurements of bone mineral properties are limited to the L2-L4 vertebral bodies. The purpose of this investigation was to determine whether bone mineral properties of the lumbar spine correlate with the failure properties of thoracic vertebrae. Cadaveric lumbar segments were scanned using dual-energy x-ray absorptiometry (DXA) from both the lateral and anteroposterior projections. Three-body segments L1-L3 and T10-T12 were then compressed to create crush fractures in the L2 and T11 vertebral bodies, and linear correlation analyses were performed to compare each DXA measure with the failure properties of L2 and T11. Lumbar BMD from the lateral view correlated significantly with T11 ultimate load (r = 0.94, P < 0.001), as did lumbar BMD from the anteroposterior projection (r = 0.83, P = 0.001). Significant correlations were also found between both lumbar BMD and BMC and the stiffness and energy to failure of T11. Furthermore, BMD and BMC measured at L2 correlated significantly with L2 ultimate load, stiffness, and energy to failure. We conclude that bone mineral properties measured at the lumbar spine provide a valid assessment of the compressive strength of both thoracic and lumbar vertebrae. Lumbar BMD may therefore be used to derive an index for the prediction of thoracolumbar fractures to aid in the early intervention of vertebral fractures.

Absorptiometry, Photon↗

Coralline hydroxyapatite bone graft substitutes in a canine metaphyseal defect model: radiographic-biomechanical correlation.

Radiographic and biomechanical assessment of a new type of bone graft substitute derived from reef-building sea coral was performed in a canine metaphyseal defect model. Blocks of this material and autogenous iliac crest graft were implanted, respectively, into the right and left proximal tibial metaphyses of eight dogs. Qualitative and quantitative radiographic evaluation was performed in the immediate postoperative period and at 6 months after surgery. Biomechanical testing was carried out on all grafts following harvest at 6 months, as well as on nonimplanted coralline hydroxyapatite and autogenous iliac cancellous bone. In contrast to autografts, incorporation of coralline implants was characterized by predictable osseous growth and apposition with preservation of intrinsic architecture. Greater percent increase in radiographic density, higher ultimate compressive strength, and lower stiffness with incorporation were documented advantages of coralline hydroxyapatite over autogenous graft. Densitometric measurements correlated moderately with strength for both types of graft material (r = -0.65). These promising results have important implications to the clinical application of coralline hydroxyapatite bone graft substitutes as an alternative to autogenous grafting.

Absorptiometry, Photon↗

[Mechanical tests with polymethylmethacrylate in fresh specimens and specimens obtained from loosened prosthesis (author's transl)].

Mechanical testing of specimen from fresh acrylic cement and from lossened prostheses between one and two years after implantation shows difference in compressive strength. Air bubbles, blood particles, and folds distinctly influence mechanical properties. Therefore, care should be taken to avoid these enclosures during implantation. But it is not the aging of the acrylic cement which presents the main problem in endoprosthetic fixation, but the cement-bone interface. Clinical experience and this mechanical study show that fracture of the acrylic cement is not due to primary fatigue of the material, but occurs secondarily after loosening of the bonding between bone and cement.

Biomechanical Phenomena↗

Material properties of femoral cancellous bone in axial loading. Part II: Time dependent properties.

In part I of this communication we reported on some time independent material properties of cancellous bone specimens from different regions of human femora. In part II we will report on our investigations of the time dependent behaviour, i.e. stress relaxation and creep. Cylindrical specimens were obtained from the head and condyles of pairs of cadaveric femora and subjected to axial loading. The data were evaluated statistically. The medianL values for relaxation of cancellous bone were greater in the femoral head than in the condyles, greater proximally than distally and greater medially than laterally in the condyles. The distribution of creep was found to be the reverse. The correlation analysis showed that a linear correlation between compressive strength, apparent density and the time dependent properties cannot be assumed. The time dependent properties reported here would appear to demonstrate the visco-elastic behaviour of cancellous bone. An experimental foundation and explanation is presented for the clinical practice of re-tightening cancellous bone screws one time only.

Biomechanical Phenomena↗

Loosening of the femoral component in surface replacement of the knee.

The incidence of loosening of the femoral component of the ICLH knee has been found to be lower than that of the tibial component. This is thought to be due to the fact that the compressive strength of the distal femur has been found to be greater than that of the proximal tibia. It has further been shown that the strength of even the femur can be so reduced by the osteoporosis accompanying Rheumatoid Arthritis that it becomes insufficient for adequate prosthetic fixation.

Bone Cements↗

Osteocyte death and hip fracture.

The viability of osteocytes can be demonstrated in sawn decalcified sections of bone by their lactate dehydrogenase activity. In the cancellous bone of the femoral head, the proportion of lacunae containing viable osteocytes decreased from 88 +/- 7% (mean +/- SD) at 10-29 years to 58 +/- 12% (P < 0.001) by 70-89 years. Viability in the second lumbar vertebra was 88 +/- 3% in subjects aged 25-90 years and did not decrease with age. Mean osteocyte viability in the femoral head of 21 hip fracture patients aged 72-94 years was 58 +/- 21%, similar to controls of a similar age, though there was greater variation and, in five patients, osteocyte viability was less than 25%. In hip fracture patients, microfracture callus incidence correlated positively with osteocyte viability, with little or no fracture callus observed if the bone viability was low. Ultimate compressive strength did not correlate with osteocyte viability. In the femoral head there is gradual, age-related reduction in osteocyte viability that can be more pronounced in hip fracture. Osteocyte death may affect bone quality by impairing repair of fatigue damage.

Adolescent↗

[Materials properties of zinc phosphate cements after delayed setting on refrigerated slabs].

Two of the zinc phosphate cements commonly used in orthodontics were mixed, with special attention being paid to the longest possible working time, and examined by scientific methods. The results showed that mixing should generally be carried out on frozen slabs (-18 degrees C to -24 degrees C) and for not longer than 5 min. If a maximum compressive strength is required, mixing should be done at refrigerator temperature (+4 degrees C to +8 degrees C) for no more than 1.5 min by accepting a shorter working time. Neither cement shows any notable physicochemical differences, as regards the material.

Chemical Phenomena↗

Lifelong administration of high doses of ibandronate increases bone mass and maintains bone quality of lumbar vertebrae in rats.

As part of a long-term safety study the bisphosphonate ibandronate was investigated for its effects on bone quality in lumbar vertebrae in rats. Bone area, bone density and mechanical properties were assessed by peripheral quantitative computed tomography (pQCT), dual-energy X-ray absorptiometry (DXA) and compression tests. Female and male groups of Wistar rats received either vehicle or 3, 7 or 15 mg/kg per day of ibandronate over 104 weeks orally by gavage. Compared with the control group, bone mineral density, compressive strength and stiffness were significantly higher in ibandronate-treated animals, whereas no changes occurred in strain or modulus of elasticity. The increase in vertebral body stress was significant in some of the ibandronate-treated groups. The changes in mechanical properties appear to be due mainly to an increase in bone mass. A highly significant correlation was found between bone mineral density measured either by DXA (r = 0.86) or pQCT (r = 0.85) and maximal strength in vertebral bodies (p < 0.0001 each). In conclusion, we demonstrated that lifelong administration of doses of ibandronate far in excess of any therapeutically intended dose not only increases bone mass and apparent density, but also maintains or even slightly improves bone quality. Bone mineral density measured either by pQCT or DXA can be used as a predictor for ultimate strength in rat lumbar vertebral bodies after treatment with ibandronate.

Animals↗

Artificial bone of porous tricalcium phosphate ceramics and its preliminary clinical application.

The authors have prepared the artificial bone of porous tricalcium phosphate ceramics according to an appropriate formula and manufacturing technology. Physical and chemical testing shows that it possesses several distinguishing features: the communicating pores and macro/micropores; mean pore size, 380 microns (from 240 microns to 510 microns); porosity, 46.4%; and compressive strength, 97.4 kg/cm2. It consists of CaO (49.09%) and P2O5 (48.84%). The testing of its biocompatibility shows that it is devoid of systemic or local toxicity, and free of irritation or foreign body response in tissues, and it does not result in hemolysis or mutation. The new bone readily grows into its pores with direct contact to the implanted material. 11 cases of bone defects were treated with this artificial bone with satisfactory results.

Adolescent↗

Biological cages.

Restoring a stable anterior column is essential to achieve normal spinal biomechanics. A variety of mechanical spacers have been developed and advocated for both anterior and posterior approaches. The ability to radiographically assess the "biology" of bone incorporation in these mechanical (metal) spacers is an inherent limitation. The femoral ring allograft (FRA) and posterior lumbar interbody fusion (PLIF) spacers have been developed as biological cages that permit restoration of the anterior column with a machined allograft bone (biological cage). Test results demonstrate that the FRA and PLIF Spacers have a compressive strength over 25,000 N. The pyramid shaped teeth on the surfaces and the geometry of the implant increase the resistance to expulsion at clinically relevant loads (1053 and 1236 N). The technique of anterior column reconstruction with both the FRA and the PLIF biological cages are discussed. Clinical experience with the PLIF biological cage (10 patients) and the FRA biological cage (90 patients) has not revealed any graft migration, infection, or subsidence. Additional posterior instrumentation may increase the stability of the motion segment, but the degree of stability necessary to achieve a biological union remains unclear. The incorporation of these biological cages can be monitored by conventional radiographic techniques. The method of insertion preserves the vertebral end-plates and can be performed by a minimally invasive or standard open procedure.

Adult↗

Cages: designs and concepts.

Many new interbody fusion cages have been recently developed, but clinical studies analyzing fusion outcome are still scarce. Radiological methods to assess fusion are not standardized and are often unreliable. Cages have been stated to provide good segmental distraction, provide axial load support and reduce segmental mobility, but there have been reports of failed fusions because of implant failure. This paper presents a critical opinion on current cage designs, stressing their clinical and biomechanical implications. Threaded cage designs compromise endplate integrity, and when placed in pairs have inherent limitations for distraction. Non-threaded cage designs usually preserve endplate integrity, but geometry may be inadequate to provide a good surface match to the endplate. The concept of an open frame type cage is believed to have biological advantages, because large graft volumes inside the cage can be in direct contact with host bone. Cadaveric tests suggest that open frame constructs have compressive strength similar to that of full surface contact cages. Restoration of segmental height, sagittal balance and increased neuroforaminal clearance are all functions of disc space distraction. The effect of cage instrumentation on axial load distribution, however, is not well understood. Biomechanical experiments strongly suggest supplementing cage instrumentation with posterior fixation, to achieve a marked increase in initial segmental stability. In the absence of gross segmental instability, micromotion at the host graft interface may still exist. As a result, fusion will never occur, instead a pseudoarthrosis will develop. For monitoring fusion, the use of non-metallic cages has distinct advantages, because no metal artifacts will disturb radiological assessment.

Equipment Design↗

[New hydroxylapatite cement for craniofacial surgery].

A new stoechiometric mixture of 27% dicalcium-phosphate (DCPA) and 73% tetra-calcium-phosphate (TTCP) can be prepared with water intraoperatively to a paste that subsequently sets to a structurally stabile implant composed of hydroxyapatite (HA). Primary setting time is about 20 min; pH during setting ranges from 6.5 to 8.5. There is no relevant curing heat or expansion or contraction. Compressive strength is about 50 MPa, tensile strength about 8 MPa. Over a period of about 4 h in physiological milieu, the cement converts to hydroxyapatite. This product is no longer redissolvable in normal body fluid. This cement can be used for non-load-bearing applications especially in craniofacial bone surgery. Cranial defects due to tumour or trauma as well as deficits in the facial skeleton may be reconstructed using this new biomaterial. In nine of ten patients we used the hydroxyapatite cement successfully for reconstructions in the craniofacial area. Fluid control of the operation field and implant site is extremely important and sometimes difficult to achieve. Further applications could be all non-load-bearing augmentations such as filling of blocked paranasal sinuses, of dentoalveolar cysts and defects following dental apectomy or fixation of implanted hearing-aid electrodes. The perspectives for the hydroxyapatite cement include its application as a carrier for osteogenic protein preparations, especially because of its isothermic reaction and intrinsic osteoconductive characteristics.

Bone Cements↗

[Mechanical comparison of biodegradable intervertebral lumbar cages].

INTRODUCTION: A biodegradable interbody cage for lumbar spine fusion would be able to solve several problems associated with the use of metallic cages. In a biomechanical in vitro study using human lumbar spines three different biodegradable poly(L-lactide-co-D,L-lacitide)(PLDLLA) cages were compared to metallic cages of the same design. MATERIAL AND METHOD: 40 human cadaver lumbar specimens (L3-S1) were tested in flexion, extension, rotation, and bending with a non-destructive flexibility method using a nonconstrained testing apparatus. Seven different groups were examined: (1) control group (intact) (n = 40); (2) unstable group (after discectomy L4/5) (n = 40), (3) autologous iliac crest bone graft (n = 8), (4) BAK-Cage (n = 8), (5) BIO-Cage 1 (PLDLLA) (n = 8), (6) BIO-Cage 2 (PLD-LLA/hydroxylapatite-buffer) (n = 8) and (7) BIO-Cage 3 (PLDLLA/hydroxylapatite particles of different size) (n = 8). Additionally, destructive compression tests of all implants were performed. RESULTS: In comparison to the intact motion segment all cages showed significantly lower range of motion (ROM) in all test modes (P < 0.01). There was no significant difference in stiffness values and ROM between BIO-Cages and metallic cages. Axial compression stiffness and failure load were significantly highest for metallic BAK-cages (P < 0.05). No significant difference for failure load was observed between BIO-cage 1 and the intact motion segment. However, in comparison to the intact motion segment failure load was significantly lower for BIO-cage 2 and 3 (P < 0.05). CONCLUSION: The results of this study are encouraging, because the biodegradable cages were able to limit lumbar spine motion similar to the metallic cages. Especially, the biodegradable PLDLLA cage consisting of pure polymer (BIO-Cage 1) showed adequate initial compression strength. However, further in vivo animal experiments are essential prior to the clinical application of biodegradable lumbar interbody fusion cages.

Absorbable Implants↗

[Use of the injectable bone cement Norian SRS for tibial plateau fractures. Results of a prospective 30-month follow-up study].

Reduction of the depressed joint surface in tibial plateau fractures often leaves large cancellous bone defects. These metaphyseal voids are typically filled with autogenous bone grafts that can cause a significant donor site morbidity. The use of injectable bone cement offers the opportunity to support the reduced joint surface without bone grafting. The aim of this study was to evaluate the clinical and radiological outcome as well as the period of partial weight bearing after the use of Norian SRS in tibial plateau fractures. Twenty-one patients with a mean age of 48 years were included in this prospective trial. According to the AO/OTA Classification, there were seven fractures of type B2, ten B3, one C1, one C2, and two fractures of type C3. The period of partial weight bearing was 3.7 weeks. In 18 patients the follow-up was more than 24 months. After a mean follow-up of 30 months, the Lysholm score was 87.9 at mean. The radiological part of the Rasmussen score was excellent and good in eight cases each and fair in four cases. Soft tissue reactions due to the cement were not observed. On all radiographs taken 36 months after the operation the cement bloc was still visible. The results show that Norian SRS can be used to fill metaphyseal bone defects in tibial plateau fractures. Clinical and radiological results are comparable to those of fractures treated with autologous bone graft. The high compression strength allows early full weight bearing without the risk of secondary loss of reduction.

Adult↗

Radial bending breaking resistance derived by densitometric evaluation predicts femoral neck fracture.

Bone mineral density (BMD) measurement by hip dual-energy X-ray absorptiometry (DXA) is considered the best predictor of osteoporotic fracture risk. BMD takes into account only in part the bone cross-sectional area that is an important determinant of both bone compression strength and of bending breaking resistance. From DXA measurements of proximal radius (Osteoplan, NIM, Verona, Italy) we obtained the projected outer diameter (D) and the mean diameter of the medulla (d), by an algorithm based on the assumption of a constant cortical volumetric density of 1050 g/cm3. The algorithm was validated by the good correlation found (r = 0.8) between calculated d and that actually measured by peripheral quantitative tomography (pQCT; XCT 960, Stratec, Unitrem, Italy) at the same radial site. The D and d values were used to calculate a bending breaking resistance index (BBRI) that is a component of the cross-sectional moment of inertia. The BBRI measured in 5460 women aged 35-89 years, was stable up to the age of 65-70 years and rapidly declined thereafter by 0.7% per year. This profile appears to be due to the fact that the increase in medullary area is compensated in terms of mechanical resistance by enlargement of cross-sectional area. In 68 women with either previous femoral neck (n = 41) or pertrochanteric fracture (n = 27) DXA measurements at proximal and ultradistal radius, lumbar spine and femoral neck were obtained together with the evaluation of proximal radius BBRI. The diagnostic accuracy of BBRI was somewhat comparable to that of spine and femoral neck BMD and significantly superior to that of ultradistal and proximal radius BMD, from which it was derived. Despite the obvious limitation of the cross-sectional nature of this study, our results indicate that a simple re-elaboration of the data obtained by peripheral radial densitometry may achieve diagnostic accuracy for hip fracture risk assessment only marginally lower than that of the direct measure of the BMD of the femoral neck. They also give additional support to the view that bone geometry, particularly for compact skeletal segments, is a determinant of its strength at least as important as bone density.

Absorptiometry, Photon↗

Administration of a glucocorticoid with depot effect counteracts the stimulating effect of growth hormone on cancellous and cortical bone of the vertebral body in rats.

Our earlier studies have shown that growth hormone administration could not counteract decreased longitudinal growth and cortical osteopenia of rat femora induced by a glucocorticoid with depot effect. In the present study we examined the effects of glucocorticoid on vertebral bone as well as the effect of growth hormone on vertebral bone in young growing animals also given glucocorticoid injections. Five groups of female rats (3 1/2 months) were treated for 80 days as follows: (1) saline, (2) prednisolone: Delcortol 5 mg/kg/day, (3) growth hormone: 5 mg/kg/day, (4) prednisolone and growth hormone, (5) food restriction. Vertebral dimensions, histomorphometry, and mechanical competence of the vertebral bone were examined. Growth hormone administration increased body weight, vertebral height, cross-sectional area, and volume. The compressive strength of the L4-corpus cylinder was also increased due to an increase in cancellous bone volume and an increase in the area of cortical bone surrounding the vertebral body. Glucocorticoid administration decreased body weight, height, and volume of the intact vertebrae. Histological examination revealed that glucocorticoid administration decreased the area of cortical bone surrounding the vertebral body but had no effect on the cancellous bone volume. No effect of glucocorticoid administration on mechanical strength of the L4 corpus cylinder could be detected. In agreement with our findings in cortical bone, we found no effect of growth hormone on vertebral bone when given to animals also receiving glucocorticoid injections. Growth hormone increases longitudinal growth, cortical and cancellous bone mass, and mechanical competence of the vertebral body. Glucocorticoid administration decreases longitudinal growth of the vertebrae and cortical bone mass without affecting cancellous bone mass of the vertebral body. Despite this, administration of a glucocorticoid with depot effect totally inhibits the effect of growth hormone on vertebral bone.

Aging↗

Effects of mechanical fracturing and experimental trampling on Hawaiian corals.

In situ trampling occurred under experimental conditions to quantify the differences in the responses to anthropogenic trampling in four dominant species of Hawaiian corals, Porites compressa, Porites lobata, Montipora capitata, and Pocillopora meandrina. Trampling was simulated daily for a period of nine days at which time further breakage was minimal. Forty treatment colonies produced 559 fragments. Trampling was followed by an 11-month recovery period. Coral colony and fragment mortality was low. All four species were highly tolerant of inflicted damage, suggesting that some species of corals can withstand limited pulse events that allow time for recovery. Growth rates following trampling were significantly lower in the treatment groups for three of the four species. This study demonstrated that very few trampling events can produce significant changes in growth even after a long recovery period. Survivorship of fragments is clearly size- and species-dependent in M. capitata and P. compressa. Smaller fragments (<5 cm) had higher mortality than larger fragments (>5 cm). High breakage rates for M. capitata and P. compressa are consistent with the near shore, low-energy regions they inhabit-the same environment frequented by skin divers and waders. Mechanical tests were conducted to determine tensile and compressive strengths. Pocillopora meandrina exhibited the strongest skeletal strength, followed in decreasing order by Porites lobata, Porites compressa, and Montipora capitata. The skeletal strength obtained from the experiments correlate with the wave energy present in the environments in the regions they inhabit, suggesting that structural strength of corals is an adaptive response to hydraulic stress.

Animals↗