PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Isometric”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Effect of different ankle- and knee-joint positions on gastrocnemius medialis fascicle length and EMG activity during isometric plantar flexion.

The purpose of this study was to provide evidence on the fact that the observed decrease in EMG activity of the gastrocnemius medialis (GM) at pronounced knee flexed positions is not only due to GM insufficiency, by examining muscle fascicle lengths during maximal voluntary contractions at different positions. Twenty-two male long distance runners (body mass: 78.5+/-6.7 kg, height: 183+/-6 cm) participated in the study. The subjects performed isometric maximal voluntary plantar flexion contractions (MVC) of their left leg at six ankle-knee angle combinations. To examine the resultant ankle joint moments the kinematics of the left leg were recorded using a Vicon 624 system with 8 cameras operating at 120 Hz. The EMG activity of GM, gastrocnemius lateralis (GL), soleus (SOL) and tibialis anterior (TA) were measured using surface electromyography. Synchronously, fascicle length and pennation angle values of the GM were obtained at rest and at the plateau of the maximal plantar flexion using ultrasonography. The main findings were: (a) identifiable differences in fascicle length of the GM at rest do not necessarily imply that these differences would also exist during a maximal isometric plantar flexion contraction and (b) the EMG activity of the biarticular GM during the MVC decreased at a pronounced flexed knee-joint position (up to 110 degrees ) despite of no differences in GM fascicle length. It is suggested that the decrease in EMG activity of the GM at pronounced knee flexed positions is due to a critical force-length potential of all three muscles of the triceps surae.

Ankle Joint↗

Reproducibility of surface EMG variables in isometric sub-maximal contractions of jaw elevator muscles.

The aims of this study were: (1) to develop and assess reproducibility of a new method for measuring masticatory force in the intercuspal position; (2) to test the reproducibility of surface EMG signal amplitude and spectral variables in constant force contractions of jaw elevator muscles and its dependency on inter-electrode distance. The study was performed on the masseter and temporalis anterior muscles of both sides of nine healthy volunteers. An intraoral compressive-force sensor was used to measure maximal voluntary contraction forces in the intercuspal position and to provide a visual feedback on sub-maximal forces to the subject. Three experimental sessions were performed in three days. In each session, three isometric contractions at 80% of the maximal force were sustained by the subjects for 30s. The intra-class correlation coefficient (ICC) of the maximal force measure was 71.9%. ICC of average rectified value and mean power spectral frequency of the EMG signal increased with inter-electrode distance, with values larger than 70% with 30 mm inter-electrode distance. It was concluded that surface EMG variables measured in isometric contractions of the jaw elevator muscles with the proposed force recording system show good reproducibility for clinical applications when a 30 mm inter-electrode distance is considered.

Adult↗

Muscles within muscles: Coordination of 19 muscle segments within three shoulder muscles during isometric motor tasks.

The aim of the present study was to determine how the intra-muscular segments of three shoulder muscles were coordinated to produce isometric force impulses around the shoulder joint and how muscle segment coordination was influenced by changes in movement direction, mechanical line of action and moment arm (ma). Twenty male subjects (mean age 22 years; range 18-30 years) with no known history of shoulder pathologies, volunteered to participate in this experiment. Utilising an electromyographic technique, the timing and intensity of contraction within 19 muscle segments of three superficial shoulder muscles (Pectoralis Major, Deltoid and Latissimus Dorsi) were studied and compared during the production of rapid (e.g. approximately 400ms time to peak) isometric force impulses in four different movement directions of the shoulder joint (flexion, extension, abduction and adduction). The results of this investigation have suggested that the timing and intensity of each muscle segment's activation was coordinated across muscles and influenced by the muscle segment's moment arm and its mechanical line of action in relation to the intended direction of shoulder movement (e.g. flexion, extension, abduction or adduction). There was also evidence that motor unit task groups were formed for individual motor tasks which comprise motor units from both adjacent and distant muscles. It was also confirmed that for any particular motor task, individual muscle segments can be functionally classified as prime mover, synergist or antagonist - classifications which are flexible from one movement to the next.

Adaptation, Physiological↗

EMG analysis of shoulder muscle fatigue during resisted isometric shoulder elevation.

The purpose of this study was to determine if a difference existed in the rate of fatigue of select shoulder muscles during isometric shoulder elevation and if the measured rate of fatigue was consistent from day to day. Shoulder muscle fatigue has been associated with alterations in joint mechanics and possibly contributes to shoulder dysfunction. While research exists, there is limited information on an objective and reliable measure of shoulder fatigue. Sixteen asymptomatic subjects were evaluated. The subjects held a weight equivalent to 60% of his/her Maximum Voluntary Isometric Contraction (MVIC) while elevating in the scapular plane. Surface electrodes were applied to collect electromyographic activity from the upper trapezius, middle deltoid, serratus anterior, and lower trapezius muscles while the arm was held at 90 degrees elevation. Data collection ceased when the subject was no longer able to maintain 90 degrees of elevation. The subject then rested and a second trial performed. One week later, the two-trial procedure was repeated. A significant interaction of trial x day x muscle was found for the rate of fatigue. Post hoc analysis revealed that the rate of fatigue of the middle deltoid was significantly greater than the other muscles tested. The intraday reliability was good for all muscles but interday reliability was poor except for the middle deltoid. This study suggests that the middle deltoid appears to fatigue faster than the other shoulder muscles tested at the selected level of shoulder elevation. This should be considered in designing a rehabilitation program to develop a sequence that does not overly fatigue the middle deltoid.

Adult↗

Utility of traditional and alternative EMG-based measures of fatigue during low-moderate level isometric efforts.

Traditional electromyographic (EMG) measures (e.g., amplitude, mean and median frequencies of the power spectra) have demonstrated inconsistent abilities in monitoring localized muscle fatigue at relatively low effort levels. In the present study, several alternative EMG-based fatigue indices were evaluated, derived using a logarithmic representation of the power spectrum, the fractal dimension of the raw signal, and a Poisson distribution fit to the power spectrum. These methods, along with traditional approaches, were applied to EMG data obtained from three separate experiments. In the first two experiments, 24 participants performed sustained isometric shoulder abductions and torso extensions at 30% of maximum voluntary strength (MVC). In the third experiment, another group of 12 participants performed similar shoulder exercises at 15% and 30% MVC, with repeatability assessed at 15% MVC. Both traditional and alternative EMG measures were analyzed for their 'utility', in terms of sensitivity to fatigue, variability, repeatability, and predictive ability. Results demonstrated that parameters derived from fractal analysis and the Poisson distribution demonstrated high utility. These alternative approaches appear promising as fatigue indices for low level isometric tasks.

Adult↗

The effects of electrode placement and innervation zone location on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis muscle.

The purposes of this investigation were to examine the effects of electrode placement and innervation zone (IZ) location on: (a) the torque-related patterns of responses for absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) and (b) the mean absolute and normalized EMG amplitude and MPF values. In addition, the present study examined the variability between subjects for the location of the IZ for the vastus lateralis (VL). Eight men (mean+/-SD age=23.0+/-4.3yr) performed submaximal to maximal isometric muscle actions of the dominant leg extensors. During each muscle action, fifteen channels of bipolar surface EMG signals were detected from the vastus lateralis using a linear electrode array aligned with the long axis of the muscle fibers. The results indicated that there were differences among channels 1-15 for the patterns of responses and mean values for absolute and normalized EMG amplitude and MPF versus isometric torque. Thus, normalized EMG amplitude and MPF values from different individuals cannot be compared if the EMG signals were detected from different locations over the muscle. In addition, absolute and relative (to femur length) estimates of IZ location for the VL resulted in similar inter-subject variability.

Adult↗

Analysis of surface EMG spike shape across different levels of isometric force.

This research evaluated changes in surface electromyographic (SEMG) spike shape across different levels of isometric force. Ninety-six subjects generated three 5-s isometric step contractions of the elbow flexors at 40, 60, 80, and 100% of maximal voluntary contraction (MVC). Force and bipolar SEMG activity were monitored concurrently. The mean spike amplitude (MSA) exhibited a linear increase across the four levels of force. The mean spike frequency (MSF) remained stable from 40 to 80% of MVC; it then decreased from 80 to 100% of MVC. There was a concomitant increase in mean spike slope (MSS) that indicates that the biceps brachii (BB) relied on the recruitment of higher threshold motor units (MUs) from 40 to 80% of MVC. However, there progressive decrease in the mean number of peaks per spike (MNPPS) that suggests that MU synchronization was additionally required to increase force from 80 to 100% of MVC. The spike shape measures, taken together, indicate that the decrease in frequency content of the signal was due to synchronization, not an increased probability of temporal overlap due an increase in rate-coding.

Adolescent↗

Does support surface coefficient of friction influence postural dynamics and isometric force productions of the upper extremities performed by seated subjects?

The purpose of this study is to determine if increasing the potential risk of slipping on support surface materials decreases postural dynamics and task performance. Seated subjects were asked to exert maximum horizontal two-handed isometric pushes as quickly as possible on a dynamometric bar. Reaction forces exerted at seat (Rxs and Rzs) and footrest (Rxf and Rzf) were measured using force sensors. A dynamometric bar measured horizontal push force (Fx). Global adherence ratio (micro) was calculated. Three support surface materials, characterised by different coefficients of friction, were tested. The same surfaces were placed on the seat and the footrest during a series of pushes. It was shown that the different support surfaces significantly influence Fx, Rxs, Rzs, Rzf and micro maximum values obtained at the end of the push. Even when the instructions given to the subject are to produce a maximum push, the maximum horizontal force applied to the bar differs according to the support surface material. Dynamic postural adjustments are influenced by characteristics of slipperiness of support surfaces. The coefficient of friction contributes an essential element to the program of postural dynamics, which in turn modulates the task performance. During brief isometric pushes, seated subjects have the capacity to control the potential risk of slipping.

Adult↗

Genetic CLC-1 chloride channel deficiency modifies diaphragm muscle isometric contractile properties.

Genetic deficiency of the muscle chloride channel CLC-1 leads to myotonia congenita in humans as well as myotonia in mice and goats. The hallmark of myotonia is delayed muscle relaxation due to persistent electrical discharges in the muscle. The present study tested the hypothesis that performance of CLC-1 deficient diaphragm muscle is also altered during the contractile phase of the contraction-relaxation cycle. Diaphragm of CLC-1 deficient and wild type mice underwent in vitro isometric contractility testing. Myotonia was easily demonstrable during contractions elicited by train stimulation, but was not seen during twitch stimulation or during train stimulation preceded by a series of twitch stimulations. Twitch force was reduced from 16.7+/-2.5 N/cm(2) in normal muscle to 7.2+/-1.9 N/cm(2) in CLC-1 deficient muscle (P<0.002). Isometric twitch contraction time was shortened from 19.6+/-0.9 to 15.7+/-1.0 ms (P<0.002). During repetitive 25 Hz stimulation, force/area was lower for diseased than normal muscle, whereas force as a percent of initial values declined at a faster rate for normal than diseased muscle. The latter could be accounted for by a rightward shift in the force-frequency relationship of CLC-1 deficient relative to normal muscle, as use of stimulation frequencies which elicited comparable force levels as a percentage of maximum 100 Hz tetanic force led to similar rates of fatigue. These findings indicate that genetic CLC-1 deficiency not only affects muscle relaxation (myotonia) but also modulates diaphragm performance during the contractile phase of the contraction-relaxation cycle.

Animals↗

Predictability of blood pressure response to isometric stress.

Isometric exercise causes transient systemic hypertension, but with individual differences. An attempt was made to delineate predictors of those differences by analyzing the blood pressure (BP) response in terms of variables readily measured in clinical practice. For each of 270 office patients, we determined blood pressure, heart rate (HR), electrocardiographic findings, and symptoms in response to maximal isometric and maximal dynamic exercise. For systolic BP response as the predicted measure, 4 predictor variables in combination, including age, sex, resting systolic BP, and maximal treadmill systolic BP, yielded 70% predictability. For diastolic BP, 5 predictors in combination, including handgrip strength, resting diastolic BP, treadmill HR, systolic BP, and diastolic BP, allowed 66% prediction. Not predictive of either were resting HR, abnormality of treadmill test, presence of heart disease, and certain other medical diagnoses.

Adult↗

Isokinetic and isometric lifting capacity of Chinese in relation to the physical demand of job.

The aim of the study was to formulate normative data for the lifting capacities of a normal Chinese population, in order to establish a basic foundation for further studies and to investigate the relationship between individual attributes including age, gender, height, weight, job physical demand and each type of lifting capacity. Isokinetic and isometric lifting strength at low, waist and shoulder assessment levels were measured using the LIDO Workset II based on a sample of 93 normal Chinese adults (63 men and 30 women) between the ages of 21-51. The 50th percentile score for adult Chinese female's lifting strength was 17.71% lower than the American female while the adult Chinese male's lifting strength was 14.94% lower than the American male. Lifting forces were higher in the 20-40 year age group. The isometric work mode had considerable impact on the lifting capacities, with shoulder level having the highest lifting capacities. The gender and body weight had a significant positive correlation to lifting capacity while job physical demand had a moderate correlation. Age and body heights were weakly correlated to lifting capacity.

Adult↗

Time-resolved x-ray diffraction studies on the intensity changes of the 5.9 and 5.1 nm actin layer lines from frog skeletal muscle during an isometric tetanus using synchrotron radiation.

Time-resolved x-ray diffraction studies have been made on the 5.9- and 5.1-nm actin layer lines from frog skeletal muscles during an isometric tetanus at 6 degrees C, using synchrotron radiation. The integrated intensities of these actin layer lines were found to increase during a tetanus by 30-50% for the 5.9-nm reflection and approximately 70% for the 5.1-nm reflection of the resting values. The intensity increase of both reflections was greater than that taking place in the transition from rest to rigor state. The intensity change of the 5.9-nm reflection preceded those of the myosin 42.9-nm off-meridional reflection and of the equatorial reflections, as well as the isometric tension development. The intensity profile of the 5.9-nm layer line during contraction was found to be different from that observed in the rigor state.

Actins↗

Thick filament movement and isometric tension in activated skeletal muscle.

Thick filaments can move from the center of the sarcomere to the Z-disc while the isometric tension remains stable in skinned rabbit psoas fibers activated for several minutes (Horowits and Podolsky, 1987). Using the active and resting tension-length relations and the force-velocity relation, we calculated the time course and mechanical consequences of thick filament movement in the presence and absence of the elastic titin filaments, which link the ends of the thick filaments to the Z-discs and give rise to the resting tension. The calculated time course of thick filament movement exhibits a lag phase, during which the velocity and extent of movement are extremely small. This lag phase is dependent only on the properties of the cross-bridges and the initial position of the thick filament. The time course of thick filament movement in skinned rabbit psoas fibers at 7 degrees C is well fit assuming a small initial thick filament displacement away from the center of the sarcomere; this leads to a lag of approximately 80 s before any significant thick filament movement occurs. In the model incorporating titin filaments, this lag is followed by a phase of slow, steady motion during which isometric tension is stable. The model excluding titin filaments predicts a phase of acceleration accompanied by a 50% decrease in tension. The observed time course of movement and tension are consistent with the model incorporating titin filaments. The long lag phase suggests that in vivo, significant movement of thick filaments is unlikely to occur during a single contraction. Therefore, the primary physiological function of titin filaments may be to keep the thick filaments centered during passive stretch and to prevent sarcomere asymmetry from accumulating over several contractions by recentering the thick filaments each time the muscle is relaxed.

Animals↗

Microsecond rotational motion of spin-labeled myosin heads during isometric muscle contraction. Saturation transfer electron paramagnetic resonance.

We have used saturation transfer electron paramagnetic resonance (ST-EPR) to detect the microsecond rotational motions of spin-labeled myosin heads in bundles of skinned muscle fibers, under conditions of rigor, relaxation, and isometric contraction. Experiments were performed on fiber bundles perfused continuously with an ATP-regenerating system. Conditions were identical to those we have used in previous studies of myosin head orientation, except that the fibers were perpendicular to the magnetic field, making the spectra primarily sensitive to rotational motion rather than to the orientational distribution. In rigor, the high intensity of the ST-EPR signal indicates the absence of microsecond rotational motion, showing that heads are all rigidly bound to actin. However, in both relaxation and contraction, considerable microsecond rotational motion is observed, implying that the previously reported orientational disorder under these conditions is dynamic, not static, on the microsecond time scale. The behavior in relaxation is essentially the same as that observed when myosin heads are detached from actin in the absence of ATP (Barnett and Thomas, 1984), corresponding to an effective rotational correlation time of approximately 10 microseconds. Slightly less mobility is observed during contraction. One possible interpretation is that in contraction all heads have the same mobility, corresponding to a correlation time of approximately 25 microseconds. Alternatively, more than one motional population may be present. For example, assuming that the spectrum in contraction is a linear combination of those in relaxation (mobile) and rigor (immobile), we obtained a good fit with a mole fraction of 78-88% of the heads in the mobile state. These results are consistent with previous STEPR studies on contracting myofibrils(Thomas et al., 1980). Thus most myosin heads undergo microsecond rotational motions most of the time during isometric contraction, at least in the probed region of the myosin head.These motions could arise primarily from the free rotations of heads detached from actin. However, if most of these heads are attached to actin during contraction, as suggested by stiffness measurements, this result provides support for the hypothesis that sub-millisecond rotational motions of actin-attached myosin heads play an important role in force generation.

Animals↗

On the theory of muscle contraction: filament extensibility and the development of isometric force and stiffness.

The newly discovered extensibility of actin and myosin filaments challenges the foundation of the theory of muscle mechanics. We have reformulated A. F. Huxley's sliding filament theory to explicitly take into account filament extensibility. During isometric force development, growing cross-bridge tractions transfer loads locally between filaments, causing them to extend and, therefore, to slide locally relative to one another. Even slight filament extensibility implies that 1) relative displacement between the two must be nonuniform along the region of filament overlap, 2) cross-bridge strain must vary systematically along the overlap region, and importantly, 3) the local shortening velocities, even at constant overall sarcomere length, reduce force below the level that would have developed if the filaments had been inextensible. The analysis shows that an extensible filament system with only two states (attached and detached) displays three important characteristics: 1) muscle stiffness leads force during force development; 2) cross-bridge stiffness is significantly higher than previously assessed by inextensible filament models; and 3) stiffness is prominently dissociated from the number of attached cross-bridges during force development. The analysis also implies that the local behavior of one myosin head must depend on the state of neighboring attachment sites. This coupling occurs exclusively through local sliding velocities, which can be significant, even during isometric force development. The resulting mechanical cooperativity is grounded in fiber mechanics and follows inevitably from filament extensibility.

Actins↗

The effect of finger extensor mechanism on the flexor force during isometric tasks.

The role of the intrinsic finger flexor muscles was investigated during finger flexion tasks. A suspension system was used to measure isometric finger forces when the point of force application varied along fingers in a distal-proximal direction. Two biomechanical models, with consideration of extensor mechanism Extensor Mechanism Model (EMM) and without consideration of extensor mechanism Flexor Model (FM), were used to calculate forces of extrinsic and intrinsic finger flexors. When the point of force application was at the distal phalanx, the extrinsic flexor muscles flexor digitorum profundus, FDP, and flexor digitorum superficialis, FDS, accounted for over 80% of the summed force of all flexors, and therefore were the major contributors to the joint flexion at the distal interphalangeal (DIP), proximal interphalangeal (PIP), and metacarpophalangeal (MCP) joints. When the point of force application was at the DIP joint, the FDS accounted for more than 70% of the total force of all flexors, and was the major contributor to the PIP and MCP joint flexion. When the force of application was at the PIP joint, the intrinsic muscle group was the major contributor for MCP flexion, accounting for more than 70% of the combined force of all flexors. The results suggest that the effects of the extensor mechanism on the flexors are relatively small when the location of force application is distal to the PIP joint. When the external force is applied proximally to the PIP joint, the extensor mechanism has large influence on force production of all flexors. The current study provides an experimental protocol and biomechanical models that allow estimation of the effects of extensor mechanism on both the extrinsic and intrinsic flexors in various loading conditions, as well as differentiating the contribution of the intrinsic and extrinsic finger flexors during isometric flexion.

Biomechanical Phenomena↗

The relative activation of elbow-flexor muscles in isometric flexion and in flexion/extension movements.

Coordination studies of multi-joint movements suggest that the central nervous system uses some constraints to reduce the large number of degrees of freedom of the arm. To gain insight into how the net joint torque is distributed among the muscles, intramuscular EMG recordings were made to determine the relative activation of five major elbow-flexor muscles during isometric, shortening, and lengthening contractions at three elbow joint angles. A regularization procedure was used to evaluate the effect of two different approaches used to calculate the relative contribution of elbow-flexor muscles to joint torque from intramuscular EMG recordings. The results demonstrate a significant increase of the relative contribution of the biarticular muscles for more extended elbow joint angles and for isotonic tasks relative to isometric tasks.

Adult↗

Effects of palmatine on isometric force and intracellular calcium levels of arterial smooth muscle.

The effects of palmatine on isometric force and intracellular free calcium levels ([Ca2+]i) were determined in isolated rat arterial strips. Palmatine dose-dependently relaxed the contractile responses stimulated by phenylephrine (PE) in aortic strips. In contrast, it only partially relaxed aortic strips contracted by 51 mM KCl. Pretreatment with palmatine shifted the dose-response curves of PE both rightwards and downwards in a dose-dependent manner. When Ca2+-free solution and re-addition of Ca2+ were applied to assess PE-induced phasic and tonic contractions, palmatine was found to be effective in inhibiting both contractions. The effects of palmatine on intracellular calcium levels were measured with the bioluminescent calcium indicator aequorin in rat tail artery strips. Palmatine caused a concomitant, dose-dependent decrease in PE-activated isometric force and [Ca2+]i, resulting in small changes in the [Ca2+]i-force relationship. These results suggest that vasodilatory effect of palmatine was mediated by reducing [Ca2+]i as well as affecting [Ca2+]i sensitivity of the contractile apparatus. Palmatine-induced [Ca2+]i decreases appeared to involve decreases in both Ca2+ release from intracellular stores and Ca2+ influx through calcium channels.

Aequorin↗