PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Frequency-dependent transversal flow control in centrifugal microfluidics.

This work presents a novel flow switch for centrifugal microfluidic platforms which is solely controlled by the Coriolis pseudo force. This Coriolis switch consists of an inverse Y-structure with one common upstream channel and two symmetric outlets on a rotating disk. Above a certain threshold frequency, the Coriolis force becomes dominant that the entire flow is diverted into one of the outlets which is selected by the direction of rotation. The threshold frequency has been measured to be 350 rad s(-1)(approximately 55.7 Hz) for a channel width of 360 microm and a depth of 125 microm. The results are supported by extensive CFD simulations.

Journal Article↗

An integrated AC electrokinetic pump in a microfluidic loop for fast and tunable flow control.

We have built a dedicated lab on a chip to study the performance of an integrated electrokinetic micropump, driven by a low voltage AC signal. This micropump consists of an array of interdigitated electrodes and is here integrated in a microfluidic loop. We demonstrate that this device can pump continuously and reproducibly electrolyte solutions of low to moderate ionic strength. The pumping speed reaches up to 500 [micro sign]m s(-1) in 20 [micro sign]m deep and 100 [micro sign]m wide channels with a driving signal in the 1-10 kHz range and an amplitude of only a few volts. In addition, we have observed an interesting reversal of the pumping direction at higher frequencies (50-100 kHz). Our device permits a systematic and automated exploration of the influence of the ionic strength thanks to an integrated micromixer.

Journal Article↗

Monolayer-functionalized microfluidics devices for optical sensing of acidity.

This paper describes the integration of opto-chemosensors in microfluidics networks. Our technique exploits the internal surface of the network as a platform to build a sensing system by coating the surface with a self-assembled monolayer and subsequently binding a fluorescent sensing molecule to the monolayer. Fluorescent molecules were used that can switch between a fluorescent and a non-fluorescent state, depending on the acidity of the surrounding solution. Two systems were investigated. The first employs surface confinement of a Rhodamine B dye in a glass micro channel that serves as a molecular switch in organic solutions. Upon rinsing the micro channels with acidic or basic solutions it was possible to switch between the fluorescent and non-fluorescent forms reversibly. Moreover, this system could be used to monitor the mixing of two solutions of different acidity along the micro channel. To widen the scope of optical sensing in micro channels an Oregon Green dye derivative was immobilized, which functions as a sensing molecule for pH differences in aqueous solutions. In this case, a hybrid system was used consisting of a glass slide and PDMS channels. The fluorescence intensity was found to be directly correlated to the pH of the solution in contact, indicating the possibility of using such a system as a pH sensor. These systems allow real-time measurements and can be easily implemented in micro- and nanofluidics systems thus enabling analysis of extremely small sample volumes in a fast and reproducible manner.

Journal Article↗

Bulk modification of polymeric microfluidic devices.

The surface properties of microfluidic devices play an important role in their flow behavior. We report here on an effective control of the surface chemistry and performance of polymeric microchips through a bulk modification route during the fabrication process. The new protocol is based on modification of the bulk microchip material by tailored copolymerization of monomers during atmospheric-pressure molding. A judicious addition of a modifier to the primary monomer solution thus imparts attractive properties to the plastic microchip substrate, including significant enhancement and/or modulation of the EOF (with flow velocities comparable to those of glass), a strong pH sensitivity and high stability. Carboxy, sulfo, and amino moieties have thus been introduced (through the incorporation of methylacrylic acid, 2-sulfoethyl-methacrylate and 2-aminoethyl-methacrylate monomers, respectively). A strong increase in the electroosmotic pumping compared to the native poly(methylmethacrylate)(PMMA) microchip (ca. electroosmotic mobility increases from 2.12 to 4.30 x 10(-4) cm(2) V(-1) s(-1)) is observed using a 6% methylacrylate (MAA) modified PMMA microchip. A 3% aminoethyl modified PMMA microchip exhibits a reversal of the electroosmotic mobility (for example, -5.6 x 10(-4) cm(2) V(-1) s(-1) at pH 3.0). The effects of the modifier loading and the pH on the EOF have been investigated for the MAA-modified PMMA chips. The bulk-modified devices exhibit reproducible and stable EOF behavior. The one step fabrication/modification protocol should further facilitate the widespread production of high-performance plastic microchip devices.

Journal Article↗

Microfluidic channel fabrication in dry film resist for production and prototyping of hybrid chips.

Microfluidic networks are patterned in a dry film resist (Ordyl SY300/550) that is sandwiched in between two substrates. The technique enables fabrication of complex biochips with active elements both in the bottom and the top substrate (hybrid chips). The resist can be double bonded at relatively low temperatures without the use of extra adhesives. A postbake transfers the resist into a rigid structure. The resist is qualified in terms of resolution, biocompatibility and fluidic sealing. Fabrication in both a fully equipped cleanroom setting as well as a minimally equipped laboratory is described. The technique is applied for dielectrophoresis-based cell separation systems and a fuel cell reaction chamber with micropillars. The dry film resist can be considered a cheap and fast alternative to SU-8.

Journal Article↗

A method for rapid reaction optimisation in continuous-flow microfluidic reactors using online Raman spectroscopic detection.

An extremely rapid tool for continuous flow synthetic process optimisation is described. A microfluidic reaction system operating in continuous flow is used in conjunction with confocal Raman microscopy to afford rapid molecule synthesis and product quantitation. Accordingly, the approach allows for rapid reaction optimisation within a continuous flow system. Specifically, the catalytic oxidation of isopropyl alcohol (IPA) to acetone using tetra-N-propylammonium perruthanate (TPAP)/N-methylmorpholine N-oxide (NMO) in a radial interdigitated micromixer is studied as a model reaction system. The composition of the reaction effluent can be determined with great facility and information relating to catalyst/co-oxidant ratios, catalyst turnovers and reaction endpoints extracted. Specifically, variation of catalyst and co-oxidant volumetric flow rates between 0 and 50 microL min(-1) is used to vary reactant concentrations, define reaction residence times and control product conversions between 0 and 100%. The rapid nature of the system allows chemical information to be gathered and utilised on a sub-minute timescale.

Journal Article↗

Microfluidic routing of aqueous and organic flows at high pressures: fabrication and characterization of integrated polymer microvalve elements.

This paper presents the first systematic engineering study of the impact of chemical formulation and surface functionalization on the performace of free-standing microfluidic polymer elements used for high-pressure fluid control in glass microsystems. System design, chemical wet-etch processes, and laser-induced polymerization techniques are described, and parametric studies illustrate the effects of polymer formulation, glass surface modification, and geometric constraints on system performance parameters. In particular, this study shows that highly crosslinked and fluorinated polymers can overcome deficiencies in previously-reported microvalve architectures, particularly limited solvent compatibility. Substrate surface modification is shown effective in reducing the friction of the polymer-glass interface and thereby facilitating valve actuation. A microchip one-way valve constructed using this architecture shows a 2 x 10(8) ratio of forward and backward flow rates at 7 MPa. This valve architecture is integrated on chip with minimal dead volumes (70 pl), and should be applicable to systems (including chromatography and chemical synthesis devices) requiring high pressures and solvents of varying polarity.

Journal Article↗

Microfluidic chip-based liquid-liquid extraction and preconcentration using a subnanoliter-droplet trapping technique.

A robust and simple approach for microfluidic liquid-liquid (L-L) extraction at the subnanoliter-scale was developed for on-chip sample pretreatment. Organic solvent droplets of a few hundred pL were trapped within micro recesses fabricated in the channel walls of a microfabricated glass chip. L-L extraction was performed by delivering aqueous samples through the channel, with the sample stream continuously flowing adjacent to the droplets. The analytes in aqueous streams were enriched within the droplet with high preconcentration factors owing to both phase transfer and dissolution of organic solvent into the bypassing aqueous sample. An aqueous solution of butyl rhodamine B (BRB) and 1-hexanol were used, respectively, as sample and extractant to demonstrate the performance of the system. The fluorescence intensity of the dye extracted into the droplet was monitored in situ by LIF. The system proved to be an efficient means for achieving high enrichment factors of over 1000, with sample consumption of a few microL. Quantitative measurement of the extracted analyte was achieved with a linear response in the range 1 x 10(-9)-8 x 10(-7) M BRB. The precision of the measured fluorescence values for a 10(-7) M BRB standard with a 12.5 min preconcentration period was 6.6% RSD (n = 5).

Journal Article↗

Characterization of SU-8 for electrokinetic microfluidic applications.

The characterization of SU-8 microchannels for electrokinetic microfluidic applications is reported. The electroosmotic (EO) mobility in SU-8 microchannels was determined with respect to pH and ionic strength by the current monitoring method. Extensive electroosmotic flow (EOF), equal to that for glass microchannels, was observed at pH > or =4. The highest EO mobility was detected at pH > or =7 and was of the order of 5.8 x 10(-4) cm(2) V(-1) s(-1) in 10 mM phosphate buffer. At pH < or =3 the electroosmotic flow was shown to reverse towards the anode and to reach a magnitude of 1.8 x 10(-4) cm(2) V(-1) s(-1) in 10 mM phosphate buffer (pH 2). Also the zeta-potential on the SU-8 surface was determined, employing lithographically defined SU-8 microparticles for which a similar pH dependence was observed. SU-8 microchannels were shown to perform repeateably from day to day and no aging effects were observed in long-term use.

Journal Article↗

The liquid-liquid diffusive extraction of hydrocarbons from a North Sea oil using a microfluidic format.

Extraction of a GC-amenable hydrocarbon fraction from oil by liquid-liquid diffusion across a laminar interface can be performed in a microfluidic format. Analysis of figures of merit, determined using standard analytical techniques, show this method to be an effective new tool for rapidly processing small quantities of oil and petroleum for GC analysis. Methods based upon similar microsystems devices could find widespread use in a variety of fields, including those associated with organic geochemistry and oil exploration and production, where the manipulation of petroleum constituents (greater than C14) is necessary for analytical purposes.

Journal Article↗

High fidelity, high yield production of microfluidic devices by hot embossing lithography: rheology and stiction.

We discuss thermoforming of thermoplastic polymers for the hot-embossing lithographic (HEL) fabrication of microfluidic chips near equilibrium conditions that minimize elastic recoil for optimal motif replication. While HEL is often simplistically described as the transfer of micro- and nano-motifs into heat-softened thermoplastic materials, we describe our rational approach to selecting appropriate processing parameters.

Journal Article↗

On-line laser Raman spectroscopic probing of droplets engineered in microfluidic devices.

Sub-nanolitre droplets engineered in microfluidic devices constitute ideal microreactors to investigate the kinetics of chemical reactions on the millisecond time scale. Up to date, fluorescence detection has been extensively used in chemistry and biology to probe reactants and resultant products within such nanodroplets. However, although fluorescence is a very sensitive technique, it lacks intrinsic specificity as frequently fluorescent labels need to be attached to the species of interest. This weakness can be overcome by using vibrational spectroscopy analysis. As an illustrative example, we use confocal Raman microspectroscopy in order to probe the concentration profiles of two interdiffusing solutes within nanolitre droplets transported through a straight microchannel. We establish the feasibility of the experimental method and discuss various aspects related to the space-time resolution and the quantitativeness of the Raman measurements. Finally, we demonstrate that the droplet internal molecular mixing is strongly affected by the droplet internal flow.

Journal Article↗

A microfluidic chip based sequential injection system with trapped droplet liquid-liquid extraction and chemiluminescence detection.

A microfluidic chip-based sequential injection system with trapped droplet liquid-liquid extraction preconcentration and chemiluminescence detection was developed for achieving high sensitivity with low reagent and sample consumption. The microfabricated glass lab-chip had a 35 mm long extraction channel, with 134 shrunken opening rectangular recesses (L 100 microm x W 50 microm x D 25 microm) arrayed within a 1 mm length on both sides of the middle section of the channel. Ketonic peroxyoxalate ester solution was filled in the recesses forming organic droplets, and keeping the aqueous sample solution flowing continuously in the extraction channel; analytes were transferred from the aqueous phase into the droplets through molecular diffusion. After liquid-liquid extraction preconcentration, catalyst and hydrogen peroxide solutions were introduced into the channel, and mixed with analytes and peroxyoxalate ester to emit chemiluminescence light. The performance of the system was tested using butyl rhodamine B, yielding a precision of 4% RSD (n = 5) and a detection limit of 10(-9) M. Within a 17 min analytical cycle, the consumptions of sample and peroxyoxalate solutions were 2.7 microL and 160 nL, respectively.

Journal Article↗

PDMS-based microfluidics for proteomic analysis.

A microfluidic poly(dimethylsiloxane) (PDMS) microdevice was realized, combining on-line protein electrophoretic separation, selection, and digestion of a protein of interest for identification by mass spectrometry. The system includes eight integrated valves and one micropump dedicated to control the flow operations. Myoglobin was successfully isolated from bovine serum albumin (BSA), then selected using integrated valves and digested in a rotary micromixer. Proteolytic peptides were recovered from the micromixer for protein identification. Total analysis from sample injection to protein identification is performed under 30 minutes, with samples of tens of nanolitres. The paper shows that PDMS technology can be successfully used for integrating complex preparation protocols of proteic samples prior to MS analysis.

Journal Article↗

The intrinsic charge on hydrophobic microfluidic substrates.

A synthesis of the literature provides an explanation for the hitherto unexplained charge on hydrophobic microfluidic substrates. It is due to the adsorption of hydroxide ions created by the enhanced autolysis of water at these surfaces.

Journal Article↗

Complexities in ETS-domain transcription factor function and regulation: lessons from the TCF (ternary complex factor) subfamily. The Colworth Medal Lecture.

The ETS-domain transcription factor family can be divided into a series of subfamilies. Elk-1 represents the founding member of the ternary complex factor (TCF) subfamily. By focusing on the TCF subfamily, we can demonstrate the complexities that exist in the function and regulation of ETS-domain transcription factors. This article focuses on Elk-1 in detail and summarizes the functions of other TCFs. The key themes covered include the domain structure of the TCFs, the mechanisms of complex formation with serum response factor, regulation of TCFs by mitogen-activated protein kinase cascades, and transcriptional regulatory properties of the TCFs. Finally, the emerging role of the TCFs in vivo is discussed. A picture is developing indicating that, while these proteins exhibit significant sequence and functional conservation, key differences in their structure and regulation are being identified which may relate to unique functions of these proteins in vivo.

Amino Acid Sequence↗

3D focusing of nanoparticles in microfluidic channels.

Dynamic focusing of particles can be used to centre particles in a fluid stream, ensuring the passage of the particles through a specified detection volume. This paper describes a method for focusing nanoparticles using dielectrophoresis. The method differs from other focusing methods in that it manipulates the particles and not the fluid. Experimental focusing is demonstrated for a range of different particle types, and discussed in terms of the operational limits of the device. Dynamic numerical simulations of the particle motion in the device are presented and compared with the experimental results. The potential of the device for nanoparticle control and manipulation in microfluidic chips is discussed.

Journal Article↗