PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Power”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Effects of temperature, adrenaline and ryanodine on power production in rainbow trout oncorhynchus mykiss ventricular trabeculae

This study is the first to examine the contractility of teleost ventricular muscle in an oscillating muscle preparation. The experiments were designed to test the relative importance of Ca2+ released from the sarcoplasmic reticulum (SR) and Ca2+ influx across the sarcolemma (SL) to cardiac performance in rainbow trout Oncorhynchus mykiss. Adrenaline and ryanodine were used to modulate Ca2+ flux through the SL and SR, respectively. Experiments were conducted at two temperatures (12 degreesC and 22 degreesC) (1) to investigate the effect of an acute temperature change (from 12 degreesC to 22 degreesC) on power production, and (2) to test the effects of acute temperature change on the relative contributions of the SR and SL Ca2+ flux to power production. Concordant with isometric studies, the results showed that trans-sarcolemmal influx was the major source of Ca2+ (approximately 90 %) for cardiac power production at all temperatures. This SL Ca2+ influx was increased with adrenergic stimulation. The power curves generated in this study suggest an optimum frequency for power production of approximately 1.0 Hz at 12 degreesC, which corresponds well to typical in vivo heart rates for rainbow trout at that temperature. Further, this study indicated that temperature-induced changes in power output cannot be predicted from temperature-induced changes in isometric tension because the temperature-sensitivity of work and power proved to be greater than that of isometric tension. This finding is important because many previous studies have assessed cardiac contractility using only isometric tension.

Journal Article↗

Power output by an asynchronous flight muscle from a beetle.

The basalar muscle of the beetle Cotinus mutabilis is a large, fibrillar flight muscle composed of approximately 90 fibers. The paired basalars together make up approximately one-third of the mass of the power muscles of flight. Changes in twitch force with changing stimulus intensity indicated that a basalar muscle is innervated by at least five excitatory axons and at least one inhibitory axon. The muscle is an asynchronous muscle; during normal oscillatory operation there is not a 1:1 relationship between muscle action potentials and contractions. During tethered flight, the wing-stroke frequency was approximately 80 Hz, and the action potential frequency in individual motor units was approximately 20 Hz. As in other asynchronous muscles that have been examined, the basalar is characterized by high passive tension, low tetanic force and long twitch duration. Mechanical power output from the basalar muscle during imposed, sinusoidal strain was measured by the work-loop technique. Work output varied with strain amplitude, strain frequency, the muscle length upon which the strain was superimposed, muscle temperature and stimulation frequency. When other variables were at optimal values, the optimal strain for work per cycle was approximately 5%, the optimal frequency for work per cycle approximately 50 Hz and the optimal frequency for mechanical power output 60-80 Hz. Optimal strain decreased with increasing cycle frequency and increased with muscle temperature. The curve relating work output and strain was narrow. At frequencies approximating those of flight, the width of the work versus strain curve, measured at half-maximal work, was 5% of the resting muscle length. The optimal muscle length for work output was shorter than that at which twitch and tetanic tension were maximal. Optimal muscle length decreased with increasing strain. The curve relating work output and muscle length, like that for work versus strain, was narrow, with a half-width of approximately 3 % at the normal flight frequency. Increasing the frequency with which the muscle was stimulated increased power output up to a plateau, reached at approximately 100 Hz stimulation frequency (at 35 degrees C). The low lift generated by animals during tethered flight is consistent with the low frequency of muscle action potentials in motor units of the wing muscles. The optimal oscillatory frequency for work per cycle increased with muscle temperature over the temperature range tested (25-40 degrees C). When cycle frequency was held constant, the work per cycle rose to an optimum with increasing temperature and then declined. We propose that there is a temperature optimum for work output because increasing temperature increases the shortening velocity of the muscle, which increases the rate of positive work output during shortening, but also decreases the durations of the stretch activation and shortening deactivation that underlie positive work output, the effect of temperature on shortening velocity being dominant at lower temperatures and the effect of temperature on the time course of activation and deactivation being dominant at higher temperatures. The average wing-stroke frequency during free flight was 94 Hz, and the thoracic temperature was 35 degrees C. The mechanical power output at the measured values of wing-stroke frequency and thoracic temperature during flight, and at optimal muscle length and strain, averaged 127 W kg(-1)muscle, with a maximum value of 200 W kg(-1). The power output from this asynchronous flight muscle was approximately twice that measured with similar techniques from synchronous flight muscle of insects, supporting the hypothesis that asynchronous operation has been favored by evolution in flight systems of different insect groups because it allows greater power output at the high contraction frequencies of flight.

Animals↗

Relationship between power and sprint freestyle swimming.

In an effort to determine the role played by power in sprint swimming, 40 competitive swimmers (22 females and 18 males) were tested for arm power at velocities ranging from 1.60-3.28 m . s-1 using an apparatus that was specifically designed to mimic the arm action during swimming. Measurements were also made to determine the contribution of fatigability to spring swimming performance. In addition, each swimmer performed a series of 25-yd (22.86 m) freestyle sprints. A close relationship was found between power output and sprint swimming performance (r = 0.90). The highest power recordings were obtained at test velocities of 2.05 and 2.66 m . s-1, with the average velocity required for peak power being 2.40 m . s-1. This point is referred to as the optimal velocity. Four detrained swimmers were tested before and after 4 wk of isokinetic strength training only. On the average, performance improved 3.76%, while arm power increased by 18.66%. The fatigability of the competitive swimmers was not related to their sprint ability (r = 0.01). It is concluded that power, as measured in this study, offers an objective assessment of a component essential for success in sprint swimming.

Adolescent↗

A simulation of speed skating performances based on a power equation.

Using kinetics of aerobic and anaerobic power production as measured during supramaximal bicycle tests of five speed skaters of international level, a model of the kinetics of power production during skating is obtained. Velocity time courses of a generalized speed skater were calculated for all Olympic distances (500 m, 1000 m, 1500 m, 5000 m, and 10,000 m) by means of simulation of an equation of produced power, power dissipated to air and ice friction, and rate of change of kinetic energy of the skater. Different strategies of distribution of anaerobic energy during a race were compared. With a single equation it appeared to be possible to simulate the mean split and final times of the five distances realized during the Winter Olympics 1988 within an error which does not exceed 1.6% (mean error in final times: 0.8%). The results show that a fast acceleration (high initial power output) is crucial for the sprinting events (500 m and 1000 m). It is shown that this initial power output level is even more important than the total amount of energy available for a 500 m and 1000 m race. For the long distances the simulations show that skaters should combine a fast but short lasting start with a constant power output following the start in order to minimize air frictional losses.

Body Weight↗

Power output and muscle myosin heavy chain composition in young and elderly men.

PURPOSE: Aging is associated with a decline in muscle volume, power output, and the velocity at which peak power (Vopt) occurs. The current study aimed to examine the relationship between lower-limb power output characteristics, muscle myosin heavy chain (MHC) composition, and lean limb volume. METHODS: Lower-limb power output during repeated efforts on an inertial sprint cycle and single-leg thrusts on the modified Nottingham power rig was studied in seven young and seven old males in relation to muscle MHC isoform composition of the vastus lateralis. RESULTS: Older subjects produced significantly lower power outputs and Vopt under all conditions (P < 0.01) and had lower proportions of fast MHC isoforms (P< 0.05). Peak power output during cycling was significantly related to lower-limb lean volume (r = 0.92, P < 0.05), whereas Vopt during sprint cycling was closely related to vastus lateralis MHC-II composition (r = 0.80, P < 0.05). CONCLUSIONS: These results provide further evidence of the importance of fast myosin isoform composition in the maintenance of dynamic muscle function in later life and particularly for maximal cycling performance.

Adult↗

Autonomic nervous function in mice and voles (Microtus arvalis): investigation by power spectral analysis of heart rate variability.

We have studied the autonomic nervous function in voles (Microtus arvalis) and mice. For this purpose, ECGs were recorded from conscious and unrestrained voles and mice using radiotelemetry and the autonomic nervous function was investigated by the power spectral analysis of heart rate variability. Heart rate in voles was lower than mice and the coefficient of variance was larger in voles. In the power spectra of voles and mice, there were two major spectral components with the high frequency (HF) peak generally appearing between 2.0 and 4.0 Hz, and the low frequency (LF) peak appearing below 0.6 Hz. On the basis of this data, we set the two frequency bands as LF (0.1-1.0 Hz) and HF (1.0-5.0 Hz) to evaluate autonomic nervous function. The LF and HF powers were larger in voles than mice. The LF/HF ratio was thought to provide a convenient index of autonomic nervous balance and was smaller in voles than mice. The LF powers in both species were reduced by atropine, but propranolol reduced the LF power only in mice. The HF power was reduced by atropine only in voles. The intrinsic heart rate produced by a double blockade with atropine and propranolol in voles was almost the same as control levels, but in mice was lower than controls. The ratio of the LF and HF powers by a double blockade were almost the same as those of the administration of atropine in voles, but nearer to propranolol in mice. These results suggested that the parasympathetic nervous function was predominant in voles, but the sympathetic one was predominant in mice.

Animals↗

[EEG power and coherence in presenile and senile depression. Characteristic findings related to differences between anxiety type and retardation type].

Quantitative EEG analysis was done on 29 medicated right-handed depressive patients at age over 45 and age and sex matched right-handed 20 normal controls. The patients were all diagnosed as major depression with melancholia by DSM-III-R and were divided into anxiety type (n = 17) and retardation type (n = 12) evaluated with the Hamilton rating scale for depression. Eye closed resting EEGs were recorded on a data recorder from the 16 electrode leads (10-20 system). Artifact rejected 3 minutes EEGs were analyzed by off-line with Fast Fourier Transform from the bilateral frontal (F3, F4), parietal (P3, P4) and occipital (O1, O2) regions. The mean values of absolute amplitude power (microV) and the mean Z scores of inter-, and intrahemispheric coherence were obtained in theta 1 (4.0-6.0 Hz), theta 2 (6.0-8.0 Hz), alpha 1 (8.0-10.5 Hz), alpha 2 (10.5-13.0 Hz), beta 1 (13.0-20.0 Hz), and beta 2 (20.0-40.0 Hz) frequency bands respectively. The main findings were: 1) Beta 1 and beta 2 power were greater in patients with anxiety type depression than in normal controls, and the differences were statistically significant over the parietal and occipital regions in beta 1 and the frontal region in beta 2. The anxiety type was distinguished from the retardation type with the increase of beta 2 power. The retardation type showed higher alpha 1 power over the frontal region and lower alpha 2 power over the occipital region than normal controls. 2) Both types showed greater frontal predominant ratio to the parietal in beta 2 power than did normal controls. The retardation type was distinguished from the anxiety type with the right predominance in beta 1 power over the frontal region. 3) Both groups of patients showed lower frontal interhemispheric coherences than normal controls in each band. In particular, the anxiety type showed significantly lower alpha 2 band and lower beta 1 and beta 2 bands. The parietal interhemispheric coherence was lower in the anxiety type but higher in the retardation type than in normal controls in each band, and this difference was prominent in theta 2 band. 4) The two groups of patients showed higher fronto-parietal intrahemispheric coherences in both hemispheres than the normal controls in each band. Especially, the anxiety type showed higher in theta two and alpha 1 bands.(ABSTRACT TRUNCATED AT 400 WORDS)

Aged↗

Introduction to power-frequency electric and magnetic fields.

This paper introduces the reader to electric and magnetic fields, particularly those fields produced by electric power systems and other sources using frequencies in the power-frequency range. Electric fields are produced by electric charges; a magnetic field also is produced if these charges are in motion. Electric fields exert forces on other charges; if in motion, these charges will experience magnetic forces. Power-frequency electric and magnetic fields induce electric currents in conducting bodies such as living organisms. The current density vector is used to describe the distribution of current within a body. The surface of the human body is an excellent shield for power-frequency electric fields, but power-frequency magnetic fields penetrate without significant attenuation; the electric fields induced inside the body by either exposure are comparable in magnitude. Electric fields induced inside a human by most environmental electric and magnetic fields appear to be small in magnitude compared to levels naturally occurring in living tissues. Detection of such fields thus would seem to require the existence of unknown biological mechanisms. Complete characterization of a power-frequency field requires measurement of the magnitudes and electrical phases of the fundamental and harmonic amplitudes of its three vector components. Most available instrumentation measures only a small subset, or some weighted average, of these quantities. Hand-held survey meters have been used widely to measure power-frequency electric and magnetic fields. Automated data-acquisition systems have come into use more recently to make electric- and magnetic-field recordings, covering periods of hours to days, in residences and other environments.(ABSTRACT TRUNCATED AT 250 WORDS)

Electromagnetic Fields↗

Performance-based adaptive power optimization for digital optical interconnects.

Optical links are traditionally set to transmit maximum power for worst-case loss and consequently to dissipate more power than is required. We describe a technique to minimize power consumption based on the measured bit-error rate (BER) of the link. This technique uses a novel power-negotiation algorithm that optimizes the link power setting to achieve minimum power dissipation for a target BER. A 0.5 microm complementary metal-oxide semiconductor optical transceiver chip was fabricated, and a free-space optical interconnect system was built for validation. The results showed that the algorithm was able to find the optimum power settings for the VCSELs for a target BER and to account for dynamic changes such as variation in the optical loss in the system.

Journal Article↗

Power-efficient dual-rate optical transceiver.

A dual-rate (2 Gbit/s and 100 Mbit/s) optical transceiver designed for power-efficient connections within and between modern high-speed digital systems is described. The transceiver can dynamically adjust its data rate according to performance requirements, allowing for power-on-demand operation. Dynamic power management permits energy saving and lowers device operating temperatures, improving the reliability and lifetime of optoelectronic-devices such as vertical-cavity surface-emitting lasers (VCSELs). To implement dual-rate functionality, we include in the transmitter and receiver circuits separate high-speed and low-power data path modules. The high-speed module is designed for gigabit operation to achieve high bandwidth. A simpler low-power module is designed for megabit data transmission with low power consumption. The transceiver is fabricated in a 0.5 microm silicon-on-sapphire complementary metal-oxide semiconductor. The VCSEL and photodetector devices are attached to the transceiver's integrated circuit by flip-chip bonding. A free-space optical link system is constructed to demonstrate correct dual-rate functionality. Experimental results show reliable link operation at 2 Gbit/s and 100 Mbit/s data transfer rates with approximately 104 and approximately 9 mW power consumption, respectively. The transceiver's switching time between these two data rates is demonstrated as 10 micros, which is limited by on-chip register reconfiguration time. Improvement of this switching time can be obtained by use of dedicated input-output pads for dual-rate control signals.

Journal Article↗

Compact and efficient kinetically enhanced copper-vapor lasers of high (100-W) average power.

We report on severalfold increases in the output power of kinetically enhanced copper-vapor lasers operating in a regime of high specific input power and reduced tube insulation. Three laser tubes, of length 1 m and bore diameters 17.5, 25, and 32 mm, were investigated at constant input power. Output power of 104 W at 1.4% wall-plug efficiency was obtained for the largest tube. When the bore diameter was decreased to 17.5 mm, the output power and efficiency remained high (90 W at 1.0% efficiency), whereas the specific output power increased threefold. The output powers were as much as fivefold higher than those of previous small-scale (i.e., <25-mm-diameter) copper lasers of any type.

Journal Article↗

PoweREST: Statistical power estimation for spatial transcriptomics experiments to detect differentially expressed genes between two conditions.

Recent advancements in spatial transcriptomics (ST) have significantly enhanced biological research in various domains. However, the high cost for current ST data generation techniques restricts the large-scale application of ST. Consequently, maximization of the use of available resources to achieve robust statistical power for ST data is a pressing need. One fundamental question in ST analysis is detection of differentially expressed genes (DEGs) under different conditions using ST data. Such DEG analyses are performed frequently, but their power calculations are rarely discussed in the literature. To address this gap, we developed PoweREST, a power estimation tool designed to support the power calculation for DEG detection with 10X Genomics Visium data. PoweREST enables power estimation both before any ST experiments and after preliminary data are collected, making it suitable for a wide variety of power analyses in ST studies. We also provide a user-friendly, program-free web application that allows users to interactively calculate and visualize study power along with relevant parameters.

Gene Expression Profiling↗

Longitudinal tracking of muscular power changes of NCAA Division I collegiate women gymnasts.

Gymnastics relies upon power as a critical component of sports-specific fitness. The purpose of this study was to monitor long-term training adaptations in the power of National Collegiate Athletics Association Division I women gymnasts. Twenty members of a women's gymnastic team (aged 18-22) were tracked over 3 years with the first year a baseline year of testing. Whole body power for the counter-movement (CMJ) and squat (SJ) vertical jump was obtained via force plate analyses at 2 assessment time points during each year (February and November). Results showed significant (p < or = 0.05) and continued increases in peak power output in the CMJ and SJ at each biannual assessment. Improvements of 46% (+1010 W) for the CMJ and 43% (+900 W) for the SJ were observed at the end of the tracking period. Peak power for the CMJ and SJ were recorded at 3210 W (+/-350 W) and 3000 W (+/-152 W), respectively. Associated improvements in the time to peak power of 36% (-0.239 second) and 38% (-0.151 second) were also found for the CMJ and SJ. There were no significant changes in body mass or total skinfold thickness, however, a shift toward improved fat free mass (i.e., lean muscle mass) was apparent. These data underscore the importance that specificity, and more importantly power development, should play in the conditioning of collegiate women gymnasts' training programs.

Adolescent↗

Effect of loading on enhancement of power performance over three consecutive trials.

The acute effects of maximal voluntary isometric contractions (MVICs) in the squat position on subsequent measures of power output over 3 consecutive sets were investigated. Sixteen trained men experienced with back squats participated in the study. A 7-second MVIC was performed 4 minutes before the execution of 5 maximal countermovement jumps (CMJs) and was repeated for 3 consecutive sets (protocol 1). The results were compared to power output performance in a similar protocol (protocol 2) that excluded the 7-second MVICs. No significant differences occurred in any of the power output measurements between protocol 1 and protocol 2, nor did significance occur linearly across the 4 sets of CMJ, with the exception of a decrease in peak power in protocol 2 (p < or = 0.05). Using both mean and maximal values only one significant correlation between either relative strength and performance enhancement or absolute strength and performance enhancement was present at p < or = 0.01. At p < or = 0.05, significant correlations were found between absolute strength and mean peak power (PP), mean peak acceleration (PA), mean peak force (PF), max PP, max PA, max PF, and max peak velocity. These data indicate that the execution of an MVIC performed before a power exercise was inadequate to acutely enhance power output over any of 3 consecutive trials.

Adult↗

The effects of carbohydrate loading on repetitive jump squat power performance.

The beneficial role of carbohydrate (CHO) supplementation in endurance exercise is well documented. However, only few data are available on the effects of CHO loading on resistance exercise performance. Because of the repetitive use of high-threshold motor units, it was hypothesized that the power output (power-endurance) of multiple sets of jump squats would be enhanced following a high-CHO (6.5 g CHO kg body mass(-1)) diet compared to a moderate-CHO (4.4 g CHO kg body mass(-1)) diet. Eight healthy men (mean +/- SD: age 26.3 +/- 2.6 years; weight 73.0 +/- 6.3 kg; body fat 13.4 +/- 5.0%; height 178.2 +/- 6.1 cm) participated in 2 randomly assigned counterbalanced supplementation periods of 4 days after having their free-living habitual diet monitored. The resistance exercise test consisted of 4 sets of 12 repetitions of maximal-effort jump squats using a Plyometric Power System unit and a load of 30% of 1 repetition maximum (1RM). A 2-minute rest period was used between sets. Immediately before and after the exercise test, a blood sample was obtained to determine the serum glucose and blood lactate concentrations. No significant difference in power performance existed between the 2 diets. As expected, there was a significant (p </= 0.05) decrease in power performance between the repetitions in every set. Blood lactate concentrations were significantly higher postexercise with both the high-CHO and the moderate- or lower-CHO diet, but there were no differences between conditions. The results indicated that the power output during multiple sets of maximal jump squats was not enhanced following a higher-CHO diet compared to a moderate- or lower-CHO diet. These data show that elevated carbohydrate intake is not needed to optimize a repetitive power-endurance performance when it is done as the first exercise in a workout.

Adult↗

Effects of alcohol on power in social interaction between man and woman.

From the McClelland et al. theory it was hypothesized that the distribution of power defined in terms of both outcome and process would be affected by alcohol in a man-woman dyad interaction situation by increasing power of the intoxicated partner. Man-woman couples (N = 30) were randomly assigned to an alcohol, a placebo or a control group. The men in the alcohol group were served a beverage containing 0.8 ml of absolute alcohol per kg of body weight. In the placebo group, the men were served a drink of orange juice and vodka essence, and the men in the control group received only orange juice. The women in all groups were served only orange juice. The same information about the kind of drinks to be served was given to both the men and the women in their respective groups. Each couple was tested individually and the experimental task consisted of 20 equal trials. The man and the woman were asked to give an individual estimation of the length of a line projected on a screen. They were then instructed to discuss their individual answers and to come to a mutual agreement on the length of the line. Outcome power was defined as the influence each one had on the actual decision and process power as each one's influence on the interaction process. Results clearly show that sober women increase their outcome power and responsibility aspects of process power over the intoxicated men, while the intoxicated men retain some of their process power as estimated in quantitative terms. The hypothesis was not supported and alternative explanations were discussed.

Adult↗

Study on EEG power and coherence in patients with mild cognitive impairment during working memory task.

To investigate the features of electroencephalography (EEG) power and coherence at rest and during a working memory task of patients with mild cognitive impairment (MCI). Thirty-five patients (17 males, 18 females; 52-71 years old) and 34 sex- and age-matched controls (17 males, 17 females; 51-63 years old) were recruited in the present study. Mini-Mental State Examination (MMSE) of 35 patients with MCI and 34 normal controls revealed that the scores of MCI patients did not differ significantly from those of normal controls (P>0.05). Then, EEGs at rest and during working memory task with three levels of working memory load were recorded. The EEG power was computed over 10 channels: right and left frontal (F3, F4), central (C3, C4), parietal (P3, P4), temporal (T5, T6) and occipital (O1, O2); inter-hemispheric coherences were computed from five electrode pairs of F3-F4, C3-C4, P3-P4, T5-T6 and O1-O2 for delta (1.0-3.5 Hz), theta (4.0-7.5 Hz), alpha-1 (8.0-10.0 Hz), alpha-2 (10.5 -13.0 Hz), beta-1 (13.5-18.0 Hz) and beta-2 (18.5-30.0 Hz) frequency bands. All values of the EEG power of MCI patients were found to be higher than those of normal controls at rest and during working memory tasks. Furthermore, the values of EEG power in the theta, alpha-1, alpha-2 and beta-1 bands of patients with MCI were significantly high (P<0.05) in comparison with those of normal controls. Correlation analysis indicated a significant negative correlation between the EEG powers and MMSE scores. In addition, during working memory tasks, the EEG coherences in all bands were significantly higher in the MCI group in comparison with those in the control group (P<0.05). However, there was no significant difference in EEG coherences between two groups at rest. These findings comprise evidence that MCI patients have higher EEG power at rest, and higher EEG power and coherence during working conditions. It suggests that MCI may be associated with compensatory processes at rest and during working memory tasks. Moreover, failure of normal cortical connections may be exist in MCI patients.

Aged↗

Evaluation of human middle ear function via an acoustic power assessment.

Measurements of middle ear (ME) acoustic power flow (power reflectance, power absorption, and transmittance) and normalized impedance (acoustic resistance, acoustic reactance, and impedance magnitude) were compared for their utility in clinical applications. Transmittance, a measure of the acoustic power absorbed by the ME, was found to have several important advantages over other measures of acoustic power flow. In addition to its simple and audiologically relevant physical interpretation (absorbed power), the normal transmittance curve has a simple shape that is visually similar to the ME transfer function. The acoustic impedance measures (resistance and reactance) provided important additional information about ME status and supplemented transmittance measurements. Together these measurements can help identify unusual conditions such as eardrum perforations. While this article is largely a review of the development of a commercial power reflectance measurement system, previously unpublished experimental results are presented.

Acoustic Impedance Tests↗