PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

Verapamil drug metabolism studies by automated in-tube solid phase microextraction.

Verapamil is a common calcium antagonist described with antianginal, antihypertensive and antiarrythmic properties. The metabolites of verapamil have also shown pharmacological properties and therefore sample preparation and analysis techniques capable of metabolic screening for verapamil are important. In-tube SPME is a relatively new method integrating sample extraction, concentration and introduction into one single step without the use of organic solvents. The capability of in-tube SPME in bioanalysis has been reviewed but there has been no application described in the field of drug metabolism. Since automation and interfacing of in-tube SPME coupled to liquid chromatography-mass spectrometry (LC-MS) is possible, we confirm in this study that it is a powerful method to monitor the main metabolites of verapamil in various biological matrices like plasma, urine and cell culture media. Further, we show that it could also be used in routine pharmacokinetics measurements. An in-tube SPME LC-MS method was developed to extract and analyze the metabolic profile of verapamil from biological matrices. The detection limit for verapamil, gallopamil, norverapamil and PR22 were 52, 53, 65 and 83 ng/ml (UV detection) and 5, 6, 6 and 8 ng/ml (MS detection), respectively. The precision of the method was calculated in various biological matrices and the average % R.S.D. (N=5) for verapamil, gallopamil, norverapamil and PR22 was 3.9, 3.7, 3.8 and 4.3% (MS detection), respectively. The linear dynamic range was determined to be 100-800 ng/ml (UV detection) with a total sample preparation and analysis time of 34 min.

Animals↗

Determination of polychlorinated biphenyls in milk samples by saponification-solid-phase microextraction.

A saponification-HSSPME procedure has been developed for the extraction of PCBs from milk samples. Saponification of the samples improves the PCB extraction efficiency and allows attaining lower background. A mixed-level fractional design has been used to optimize the sample preparation process. Five variables have been considered: extraction time, agitation, kind of microextraction fiber, concentration, and volume of NaOH aqueous solution. Also the kinetic of the process has been studied with the two fibers (100-microm PDMS and 65-microm PDMS-DVB) included in this study. Analyses were performed on a gas chromatograph equipped with an electron capture detector and a gas chromatograph coupled to a mass selective detector working in MS-MS mode. The proposed method is simple and rapid, and yields high sensitivity, with detection limits below 1 ng/mL, good linearity, and reproducibility. The method has been applied to liquid milk samples with different fat content covering the whole commercial range, and it has been validated with powdered milk certified reference material.

Animals↗

Solid-phase microextraction in combination with GC/MS for quantification of the major volatile free fatty acids in ewe cheese.

This work describes a method for quantification of the major free fatty acids of ewe cheese that contribute to its distinct and strongly marked flavor. A headspace SPME method in combination with GC/MS was used for the extraction, identification, and quantification of butanoic, hexanoic, octanoic and decanoic acids in ewe cheeses. The method used for sample preparation was simple. A fiber coated with 85-microm polyacrylate film was chosen to extract the free fatty acids. To perform a reliable quantification, several factors were taken into consideration for reliable quantification, namely, (i) the influence of addition of water, of an electrolyte or of a hygroscopic salt, on the release of free fatty acids from the matrix; (ii) the linear relationship between the amount of analyte adsorbed by the SPME polymer film and the initial concentration of the analyte in the cheese sample; and (iii) the competition for adsorption by fiber. Water removal with sodium sulfate promoted a more efficient extraction of volatile free fatty acids; biases due to competition or linear range excesses were controlled by choosing the appropriate amount of sample for each ewe cheese. The method of standard additions was used with success for the quantification of free fatty acids. Calibration curves that were constructed for the major short-chain free fatty acids (butanoic, hexanoic, octanoic, and decanoic acids) spiked into cheese followed linear relationships with highly significant (p < 0.001) correlation coefficients (r > 0.999). Coefficients of variation of <7.9% indicated that the technique was reproducible. A marked increase in concentration of short-chain free fatty acids was observed during cheese ripening, ranging from 0.35 to 9.33 mg/100 g for butanoic acid, 0.363 to 4.34 mg/100 g for hexanoic acid, 0.343 to 2.0 mg/100 g for octanoic acid, and 1.291 to 3.85 mg/100 g for decanoic acid. The limits of quantification were registered at levels of parts per million. The absolute quantification of butanoic acid was also carried out by using isotope dilution assays (IDA). The levels of acid obtained with this method were similar to those obtained by the standard additions method.

Animals↗

Kinetics and the on-site application of standards in a solid-phase microextraction fiber.

The kinetics of the desorption of analytes from a SPME fiber into an agitated sample matrix was studied, and a theoretical model was proposed to describe the dynamic desorption process, based on the steady-state diffusion of analytes in the extraction phase and in the boundary layer. It was found that the desorption of analytes from a SPME fiber into an agitated sampling matrix is isotropic to the absorption of the analytes onto the SPME fiber from the sample matrix under the same agitation conditions, and this allows for the calibration of absorption using desorption. The calibration was accomplished by exposing a SPME fiber, preloaded with a standard, to an agitated sample matrix, during which desorption of the standard and absorption of analytes occurred simultaneously. When the standard was the isotopically labeled analogue of the target analyte, the information from the desorption process, i.e., time constant a, could be directly used for estimating the concentration of the target analyte. When the standard varied from the target analyte, the mass-transfer coefficient of the analyte could be extrapolated from that of the standard. These predictions agree well with experimental results. This approach facilitates the full integration of sampling, sample preparation, and sample introduction, especially for on-site or in vivo investigations, where the addition of standards to the sample matrix, or control of the velocity of the sample matrix, is very difficult.

Journal Article↗

Time-weighted average water sampling with a solid-phase microextraction device.

A fiber-in-needle SPME device was developed and investigated for time-weighted average water sampling. The device was designed so that the overall mass-transfer resistance is contained within the static water inside the needle, which ensures that mass uptake could be predicted with Fick's first law of diffusion and the sampling rate is less affected by water turbulence. The device possesses all of the advantages of commercialized devices, in addition to needle filling and replacement ease. Laboratory calibration with deployment of the device to a flow-through system demonstrated that there was a linear mass uptake for up to 12 days, and the linear range could be longer. PDMS coating is assumed to be a perfect zero sink for most polycyclic aromatic hydrocarbons, except naphthalene. The effect of water temperature was also investigated. Under normal field conditions, the change of mass uptake rate with temperature was negligible. To facilitate the convenience for long-term water sampling, a new standard aqueous generator was introduced. This study extended the application of SPME technology for long-term water sampling.

Journal Article↗

Use of solid-phase microextraction for the quantitative determination of herbicides in soil and water samples.

An in-depth study of SPME optimization and application has been made, considering not only aqueous (surface water and groundwater samples) but also the more complex soil samples. Seven herbicides widely used in the area of study have been selected including five triazine herbicides (atrazine, simazine, terbumeton, terbuthylazine, terbutryn), molinate, and bromacil. linearity range was between 0.1 and 10 ng/mL and the repeatability below 10% when applying the optimized SPME procedure to water samples. Reproducibility was found to be lower than 20% at the 1 ng/mL level, and the limits of determination in environmental water samples using GC/MS (SIM mode) were well below 0.1 ng/mL (values ranging from 10 to 60 ng/L). Extraction of selected herbicides from soil was carried out by microwave-assisted solvent extraction using methanol in screw-capped vials, leading to recoveries over 80% in spiked soil samples at the 5-200 ng/g level. SPME application over methanolic soil extracts required a 10-fold dilution with distilled water. The recommended procedure was found to be fully applicable for quantitative determination of selected herbicides in soils containing low organic matter content with coefficients of variation below or around 10% and limits of determination ranging from 1 to 10 ng/g. Both procedures were applied to real-world surface water and soil samples where several pesticides were detected including atrazine, simazine, terbuthylazine, and molinate.

Herbicides↗

Determination of distribution constants between a liquid polymeric coating and water by a solid-phase microextraction technique with a flow-through standard water system

This paper describes an optimized experimental system for determining water/polymer coating distribution constants and discusses the mechanism of extraction of high molecular weight compounds by poly(dimethylsiloxane) (PDMS). The proposed flow-through standard water generator eliminates errors associated with both losses of analytes to the system surfaces and limited sample volume. In addition, the errors caused by partial precipitation or poor dissolution of highly hydrophobic analytes during spiking of water when producing calibration standards are also eliminated. The target analytes are a range of polycyclic aromatic hydrocarbons (PAHs). The results demonstrate that absorption partitioning is the predominant mechanism of extraction of analytes into PDMS-coated fibers for all PAHs investigated regardless of molecular weight. There is a strong correlation between determined PDMS/water distribution constants (K(fw)) and literature K(ow) values for all PAHs.

Journal Article↗

Solid-phase microextraction in the analysis of virgin olive oil volatile fraction: modifications induced by oxidation and suitable markers of oxidative status.

Modifications of virgin olive oil subjected to accelerated storage were evaluated by HS-SPME analysis. To find a suitable marker of oxidative degradation, the volatile compounds showing variable concentration during the oxidative process have been identified and quantified by SPME coupled to GC-MS and GC-FID, respectively. The SPME analysis results were then compared with the parameters usually applied to assess the oxidative status of lipids, such as peroxide value, spectrophotometric absorbance, and loss of unsaturated fatty acids. Finally, the assessment of nonanal has been suggested as a marker of oxidative degradation. This rapid, inexpensive, and reliable method may allow screening of oils prior to testing by a panel of assessors.

Aldehydes↗

Solid-phase microextraction in the analysis of virgin olive oil volatile fraction: characterization of virgin olive oils from two distinct geographical areas of northern Italy.

SPME was employed to characterize the volatile profile of virgin olive oils produced in two geographical areas of northern Italy: the region of the Gulf of Trieste and the area near Lake Garda. There are as yet no data on the headspace composition of virgin olive oils from these regions, characterized by particular conditions of growth for Olea europaea. Using the SPME technique coupled to GC-MS and GC-FID, the volatile components of 42 industrially produced virgin olive oil samples were identified and the principal compounds quantitatively analyzed. Significant differences in the proportion of volatile constituents from oils of different varieties and geographical origins were detected. The results suggest that besides the genetic factor, environmental conditions influence the volatile formation.

Chromatography, Gas↗

Application of solid phase microextraction in the determination of paralytic shellfish poisoning toxins.

A SPME-HPLC-post-column fluorescent derivatization method for the direct determination of saxitoxin (STX), the most potent paralytic shellfish poisoning (PSP) toxin, in water has been developed. Commercially available SPME devices with 50 microm Carbowax templated resin (CW/TPR) coating was found to be able to pre-concentrate STX from aqueous media. A special pre-conditioning treatment of soaking the SPME coating in 0.1 M NaOH solution significantly improved the extraction efficiency. The optimal pH for the SPME process is 8.1 and the equilibration time is 40 min. The partition coefficient, K, of the distribution of STX between the SPME coating and the aqueous media was measured to be 2.99 +/- 0.04 x 10(3). Extracted toxin on the SPME stationary phase was difficult to be desorbed by the HPLC mobile phase under dynamic desorption mode. A static ion-pairing desorption technique using a desorption solvent mixture of 20 mM sodium 1-heptanesulfonate in 30% aqueous acetonitrile acidified with 50 mM sulfuric acid was developed to overcome this problem. The method detection limit and repeatability achieved by this SPME-HPLC method were 0.11 ng ml(-1) and 3.7%, respectively, with a sample volume of just 5 ml of water. This analytical method is adequate for the monitoring of the PSP toxin in fresh/drinking waters. However, serious interference was observed when this technique was applied to saline water samples. This is probably due to competition of sodium ions with the cationic STX for absorption into the SPME stationary phase.

Food Contamination↗

Evaluating peats for their capacities to remove odorous compounds from liquid swine manure using headspace "solid-phase microextraction".

This paper reports on research designed to investigate the capacities of different highly characterized peats to remove odorous compounds from liquid swine manure (LSM). Peat types representing a wide range of properties were tested in order to establish which chemical and physical properties might be most indicative of their capacities to remediate odors produced by LSM. Eight percent slurries (of peat/LSM) were measured for odor changes after 24 hours using odor panel and GC/MS-Solid-phase microextraction (GC/MS-SPME) analysis. The GC/MS-SPME and odor panel results indicated that, although all peats tested in this study were found to be effective at removing odor-causing compounds found in LSM, some peats tended to work better than others. Overall, the peats that were the most effective at removing odor-causing compounds tended to have lower bulk densities, ash contents, fulvic acids contents, and guaiacyl lignins contents, and higher water holding capacities, hydraulic conductivities, "total other lignins" contents, hydrogen contents, carbon contents, and total cellulose contents. GC/MS-SPME analysis was found to be a reasonably inexpensive and efficient way of conducting this type of research. It allows one to identify a large number of the odor-causing compounds found in LSM, and more importantly, to detect with some precision specific differences in the amounts of these compounds between peat types.

Animals↗

Volatile compounds of red and white wines by headspace--solid-phase microextraction using different fibers.

The behavior of four fibers [polydimethylsiloxane (PDMS), PDMS-divinylbenzene (DVB), carboxen (CAR)-PDMS, PDMS-DVB-CAR), is tested for the analysis of volatile compounds of white and red wine. The PDMS-DVB-CAR fiber is the most appropriate to obtain the most wide volatile profile of wines. The better extraction conditions are 40 min at 35 degrees C. Satisfactory data about the reproducibility and uptake are obtained for more than 40 volatile compounds of red and white wine.

Chromatography, Gas↗

[Identification and quantitative determination of chlorinated++ solvents after solid phase microextraction. Applications in hospital toxicology].

A simple method for the research and the identification of chlorinated solvents in biological fluids and tissues is described. The solvents are extracted using headspace solidphase microextraction and detected or measured by gas chromatography with electron capture detector. Three accidental poisonings are reported: one with carbon tetrachloride, one with trichlorethylene and the last one is a double intoxication with tetrachloroethylene and trichlorethylene.

Chromatography, Gas↗

Aqueous phase hexylchloroformate derivatization and solid phase microextraction: determination of benzoylecgonine in urine by gas chromatography-quadrupole ion trap mass spectrometry.

A derivatization/solid phase microextraction (SPME) method for the determination of benzoylecgonine in urine was developed. The derivatization is conducted directly in 1 mL of urine while sonicating for 3 min with 12 microL of hexyl chloroformate and 70 microL of a mixture containing acetonitrile:water:hexanol:2-dimethylaminopyridine (5:2:2:1 v/v), yielding benzoylecgonine hexyl ester (BHE) as the product. After the 3 min period, an aliquot of 250 microL is transferred to a vial for SPME. After the desired extraction time the 100 microns polydimethylsiloxane SPME fiber was transferred to the GC-MS for separation and analysis with a quadrupole ion trap mass spectrometer. The hexyl chloroformate derivatization and SPME procedures were optimized for compatibility and sensitivity. The method was found linear for 0.10 to 20.0 micrograms/mL (r2 = 0.999) of benzoylecgonine in urine using benzoylecgonine-d3 as an internal standard (1.5 micrograms/mL). Intra-day precisions were 8.8 and 6.8% RSD for 0.30 microgram/mL and 17 micrograms/mL benzoylecgonine standards in urine (n = 6), respectively. Inter-day precision (n = 3) were < or = 3.3% RSD, indicating good reproducibility. A detection limit of 0.03 microgram/mL (S/N = 3) was achieved, thus making the SPME method a simplified alternative to SPE for GC-MS confirmation after EMIT tests for benzoylecgonine which have a cutoff of 0.30 microgram/mL. Quantitative results by SPME and SPE of two clinical urine specimens known positive for cocaine by EMIT were in excellent agreement. Benzoylecgonine was detected by the derivatization/SPME method in 22 out of 22 other urine specimens known positive for cocaine.

Calibration↗