PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Biodegradation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Comparison of different fabrication techniques used for processing 3-dimensional, porous, biodegradable scaffolds from modified starch for bone tissue engineering.

3 dimensional, porous, biodegradable scaffolds were fabricated using modified starch of varying degree of substitution (DS) by extrusion processing. Freeze drying/lyophilization was also employed to fabricate scaffolds from modified starch. The research efforts have been focused on the comparison of the above-mentioned techniques by comparing the properties of the fabricated scaffolds in the paradigm of bone tissue engineering. The physicomechanical properties like porosity, compressive strength and modulus, pore size and microstructure were tested and analyzed by liquid replacement, mechanical testing and scanning electron microscopy respectively. The biodegradability of scaffolds was evaluated by soaking the samples in aqueous medium and Hank's balanced salt solution at 37-degree invitro. The cytotoxicity studies on these scaffolds were also conducted. The scaffolds have a 3D structure consisting of interconnected pores with good porosity, pore size, adequate compressive strength and modulus and exhibit good biodegradability as well as biocompatibility. After further optimization in the processing conditions and parameters they could be made useful for bone tissue engineering.

Absorbable Implants↗

Local delivery of doxorubicin for malignant glioma by a biodegradable PLGA polymer sheet.

Implantable, biocompatible and biodegradable devices bearing an anticancer drug can provide promising local therapy to patients with malignant disorders. With the aim of treating brain tumors, especially gliomas, a membranous sheet containing doxorubicin was produced by co-polymerization to poly(D,L-lactide-co-glycolide) (PLGA). When release of the drug from the sheet was measured, sustained release continued until day 34. The data contrasted with the burst release from material containing a higher proportion of the drug. In terms of biodegradability, a subcutaneous 3 x 3-mm tetragonal sheet was almost completely absorbed by day 80. When a glioma was implanted subcutaneously and the tumor nodule exposed to the sheet, the device inhibited tumor growth significantly. The sheet consisted of an amorphous structure with cavities estimated to have a diameter of 0.5 - 3 microm by electron microscopic observation. Since the sheet is implantable, biodegradable and has a sustained-drug release property, the device may play a role in the local therapy of brain tumors.

Animals↗

[New principles of using biodegradable implants in the treatment of fractures].

So far the operative treatment of bone fractures has resolved itself to immobilisation and bone fragment joining with the help of metal implants such as nails, screws, plates and wires. Once the bone had healed, they had to be removed. This action bears some risk, e.g. extremity disfunction, wound infection. This requires re-hospitalization and increases social cost of the treatment. These reasons gave rise to research on new, biodegradable materials. One of them is "Biofix" manufactures as threads or nails, employed when immobilising bone fragments. Application of "Biofix" allows early rehabilitation. In 200 cases we utilized "Biofix" reinforced with a wire loop, which brought about positive results. In isolated cases there occurred inflammation of the tissues that surrounded the implant during its biodegradation. The surrounded tissues exhibited an acid reaction of pH 3-4. The biodegradable material "Biofix" is sensitive to torsion, which hinders making screws of it, hence the method of using it for nails, wire and thread. This issue is dealt with the Kampere Technical University.

Adult↗

Smooth muscle cell seeding in biodegradable grafts in rats: a new method to enhance the process of arterial wall regeneration.

In this study a smooth muscle cell seeding technique was developed and evaluated in biodegradable vascular grafts in rats. Cultured smooth muscle cells (3.5 to 5 X 10(6) in 0.1 ml whole blood) were seeded by means of a one-step preclotting technique in microporous, compliant, biodegradable vascular grafts (internal diameter 1.3 mm, length 1 cm; n = 16). Four seeded grafts as well as four nonseeded preclotted control grafts were histologically evaluated immediately after seeding and on preclotting; the other seeded grafts (n = 12) as well as nonseeded preclotted control grafts (n = 12) were implanted into the abdominal aorta of rats and were evaluated after 2 hours (n = 4), 2 days (n = 4), and 1 week (n = 4) with regard to the process of arterial wall regeneration. All grafts, except one seeded graft harvested at 1 week, were patent. All nonseeded control grafts showed no (at 2 hours and at 2 days) or limited (at 1 week) smooth muscle cell ingrowth. Of the 11 patent seeded grafts three also showed poor or limited neomedia development, probably because of improper preclotting. However, eight of the 11 patent seeded grafts showed fast and uniform noemedia development (clearly discernible at 2 days). Moreover, in two patent 1-week seeded grafts there were neomedia comparable in thickness and architecture (circularly arranged smooth muscle cells) to that of normal rat media, and a neointima had already lined 30% to 40% of the lumen. These results clearly demonstrate that smooth muscle cell seeding in biodegradable grafts is feasible and indicate that this seeding can enhance the process of arterial wall regeneration in these grafts.

Animals↗

Clinical evaluation of injectable biodegradable contraceptive system.

A new long-acting injectable contraceptive system was tested in 24 women. The system consists of microspheres made of biodegradable d,l-polylactic acid in which micronized crystals of norethisterone (NET) are homogeneously dispersed. In previous animal studies we showed that NET is slowly released from the microspheres for 6 months, and after the drug is released, the microspheres biodegrade into lactic acid by the process of hydrolysis. The serum levels of NET, estrogen, and progesterone were monitored by radioimmunoassay, and the effects of treatment on ovarian function and menstrual bleeding were evaluated. The doses ranged from 29 to 370 mg of microspheres containing 7.25 to 94.5 mg of NET or 0.134 to 2.30 mg of NET/kg of body weight. The duration of the NET release was 6 months, and the serum NET profiles in women were similar to those previously described in subhuman primates. Following a small burst, there was a gradual decline in the serum levels of NET over 6 months after treatment. The serum levels of NET varied in proportion to the dose. Doses less than 0.267 mg of NET/kg had no discernible effect on either ovarian function or menstrual bleeding. Doses ranging from 0.419 to 2.30 mg had variable effects on ovarian function and menstrual bleeding. Higher doses caused suppression of ovarian function for longer periods of time, increased the interval between episodes of menstrual bleeding, and decreased the quantity of blood loss during each episode. The treatment was well tolerated by all subjects, and, with the exception of spotting and irregular menstrual cycles, there were no adverse side effects. Based on this initial study, it was determined that doses ranging from 1.33 to 3.45 mg of NET/kg are necessary to suppress ovulation for 6 months. Additional studies with the use of higher doses are currently under way.

Adult↗

Prevention of experimental proliferative vitreoretinopathy with a biodegradable intravitreal implant for the sustained release of fluorouracil.

OBJECTIVE: To test the efficacy of a biodegradable device for the intravitreal sustained release of fluorouracil in the treatment of tractional retinal detachment due to proliferative vitreoretinopathy. METHODS: A 6 x 0.9-mm (20-gauge) cylindrical solid implant molded from copolymers of lactide and glycolide admixed with 1 mg of fluorouracil was placed in the vitreous cavity of rabbits in which retinal detachment with proliferative vitreoretinopathy had been initiated. Comparisons of the control (drug-free polymer) and experimental (fluorouracil polymer) groups were made with weekly indirect ophthalmoscopic examinations. In another experiment, the intravitreal concentration of fluorouracil was tested at each time point. RESULTS: Retinas of eight (89%) of nine rabbits that received the polymer with fluorouracil remained attached compared with only one animal (11%) that received the control polymer without the drug. The therapeutic effect of the drug-containing implant was associated with sustained intravitreal concentrations of fluorouracil between 1 and 13 mg/L for at least 14 days, and fluorouracil concentrations remained above 0.3 microgram/mL for almost 21 days. No evidence of the toxic effects of the drug or polymer implant was observed with electroretinographic and histopathologic study. CONCLUSION: Intravitreal implantation of biodegradable polymers containing fluorouracil can prevent proliferation of epiretinal membranes resulting in complicated retinal detachment in an animal model of proliferative vitreoretinopathy and indicate their possible usefulness for intravitreal delivery of therapeutic agents.

Animals↗

Induction of early and bioeffective antibody response in rodents with the luteinizing hormone-releasing hormone vaccine given as a single dose in biodegradable microspheres along with alum.

BACKGROUND: Previous studies in animals and phase I/phase II clinical trials in humans have shown the suppressive effect of immunization with the luteinizing hormone-releasing hormone (LHRH) vaccine on prostatic hypertrophy and hyperplasia. A drawback of this vaccine was a delay of about 8 weeks in buildup of antibody titers to efficacy level and the requirement of three injections of the vaccine given at monthly interval for full primary immunization. METHODS: LHRH vaccine was encapsulated in poly-lactic-co-glycolic acid (PLGA) 50:50 copolymer microspheres of reproducible physicochemical characteristics. Immunogenicity studies were carried out in rodents and prostate weights were determined at various antibody titers. RESULTS: The vaccine entrapped in biodegradable microspheres generated high antibody response in rats, persisting for 5-7 months following a single immunization. One hundred micrograms was the optimum dose, and the intramuscular route was more immunogenic than the subcutaneous. It was further observed that coadministration of 75% of the vaccine entrapped in microspheres with 25% adsorbed on alum generated higher antibody response in rodents, exceeding the bioeffective threshold as early as day 15 postimmunization. CONCLUSIONS: Coadministration of the LHRH vaccine in biodegradable PLGA microspheres with a quarter of the dose adsorbed on alum generates high antibody titers within 15 days, which are effective in causing atrophy of the prostate.

Alum Compounds↗

Kinetics and modeling of autotrophic thiocyanate biodegradation.

The biokinetic parameters for autotrophic systems are difficult to obtain and are often mistakenly determined because the size of the autotrophic population in mixed (i.e., heterotrophic and autotrophic) cultures cannot be accurately estimated. This article presents a systematic approach, combining bioenergetic calculations and experimental data, to obtain values of the biokinetic parameters pertinent to the aerobic, autotrophic biodegradation of thiocyanate. Nonlinear regression techniques were employed using both initial thiocyanate utilization rate data and single thiocyanate depletion curves. Both types of data were necessary to overcome the problems arising from the linear nature of the substrate depletion curves and the high correlation of the biokinetic model parameters inherent in nonlinear regression analysis. The aerobic biodegradation of thiocyanate followed a substrate inhibition pattern that was successfully described by the Haldane-Andrews model. Although regression analysis did not yield unique biokinetic parameter estimates, the following parameter value ranges were obtained: maximum specific substrate utilization rate (k), 0.26 to 0.44 mg SCN-/mg biomass h; half-saturation coefficient (Ks), 2.3 to 7.1 mg SCN-/L; and inhibition coefficient (Ki), 28 to 109 mg SCN-/L. Based on the estimated biokinetic parameter values, a design and operation diagram was constructed that depicts the steady-state thiocyanate concentration as a function of solids retention time for a completely mixed, continuous-flow reactor.

Bacteria↗

Biodegradation of neutralized sarin.

This research investigated the biotransformation of IMPA, the neutralization product of the nerve agent Sarin, by a microbial consortia. As mandated by the Chemical Weapons Convention signed by 132 countries in 1993, all chemical warfare agents are to be destroyed within ten years of ratification. Technologies must be developed to satisfy this commitment. This paper presents data from a biodegradation kinetics study and background information on the biological transformation of IMPA. Microbial transformation of organophosphate nerve agents and organophosphate pesticide intermediates can be incorporated into a treatment process for the fast and efficient destruction of these similar compounds. Sarin (isopropyl methylphosphonofluoridate), also known as GB, is one of several highly neurotoxic chemical warfare agents that have been developed over the past 50 to 60 years. Four mixed cultures were acclimated to the Sarin hydrolysis product, isopropyl methylphosphonic acid (IMPA). Two of these cultures, APG microorganisms and SX microorganisms, used IMPA as the sole phosphorus source. Extended exposure to IMPA improved the cultures' abilities to degrade IMPA to form methylphosphonic acid (MPA) and inorganic phosphate. The presence of free phosphate in the reactor suppressed the degradation of IMPA. IMPA did not inhibit either cultural consortia within the tested concentration range (0 to 1250 mg/L). The numax was 120.9 mg/L/day for the SX microorganisms and 118.3 mg/L/day for the APG microorganisms. Initial IMPA concentrations of 85 to 90 mg/L were degraded to nondetectable levels within 75 h. These results demonstrate the potential for biodegradation to serve as a complementary treatment process for the destruction of stockpiled Sarin.

Biodegradation, Environmental↗

Statistical analysis of nonlinear parameter estimation for Monod biodegradation kinetics using bivariate data.

A nonlinear regression technique for estimating the Monod parameters describing biodegradation kinetics is presented and analyzed. Two model data sets were taken from a study of aerobic biodegradation of the polycyclic aromatic hydrocarbons (PAHs), naphthalene and 2-methylnaphthalene, as the growth-limiting substrates, where substrate and biomass concentrations were measured with time. For each PAH, the parameters estimated were: q(max), the maximum substrate utilization rate per unit biomass; K(S), the half-saturation coefficient; and Y, the stoichiometric yield coefficient. Estimating parameters when measurements have been made for two variables with different error structures requires a technique more rigorous than least squares regression. An optimization function is derived from the maximumlikelihood equation assuming an unknown, nondiagonal covariance matrix for the measured variables. Because the derivation is based on an assumption of normally distributed errors in the observations, the error structures of the regression variables were examined. Through residual analysis, the errors in the substrate concentration data were found to be distributed log-normally, demonstrating a need for log transformation of this variable. The covariance between ln C and X was found to be small but significantly nonzero at the 67% confidence level for NPH and at the 94% confidence level for 2MN. The nonlinear parameter estimation yielded unique values for q(max), K(S), and Y for naphthalene. Thus, despite the low concentrations of this sparingly soluble compound, the data contained sufficient information for parameter estimation. For 2-methylnaphthalene, the values of q(max) and K(S) could not be estimated uniquely; however, q(max)/K(S) was estimated. To assess the value of including the relatively imprecise biomass concentration data, the results from the bivariate method were compared with a univariate method using only the substrate concentration data. The results demonstrated that the bivariate data yielded a better confidence in the estimates and provided additional information about the model fit and model adequacy. The combination of the value of the bivariate data set and their nonzero covariance justifies the need for maximum likelihood estimation over the simpler nonlinear least squares regression.

Biodegradation, Environmental↗

Interleukin-12 delivered by biodegradable microspheres promotes the antitumor activity of human peripheral blood lymphocytes in a human head and neck tumor xenograft/SCID mouse model.

BACKGROUND: The role of cytokines in tumor regression is now well established. The major limitation for the clinical use of cytokines is the lack of a simple and effective protocol for the local and sustained delivery of cytokines to the tumor milieu. This study reports suppression of human head and neck squamous cell carcinoma (HNSCC) by human peripheral blood lymphocytes (HuPBL) following local, sustained delivery of interleukin-12 (IL-12) to tumors with biodegradable microspheres in a human/SCID mouse chimeric model. Materials and Methods Nondisrupted biopsy pieces (120 mg) of primary HNSCC were implanted s.c. into severe combined immunodeficient (SCID) mice and were expanded by serial passage in mice. Tumors were then titrated with different doses of allogeneic HuPBL by coengraftment of tumor pieces and HuPBL into the subcutis of SCID mice to determine whether the HuPBL possessed antitumor activity (the SCID/Winn model). The lymphocyte subsets that were responsible for the suppression of tumor engraftment were identified by selective depletion of the CD4+, CD8+, and CD56+ cells from the HuPBL prior to engraftment into mice. Attempts were then made to augment the antitumor activity of the HuPBL either by repeated intralesional bolus injections of recombinant human IL-12 (0.5 microg x 10 doses) or with a single dose of IL-12-loaded microspheres ( approximately 1.65 microg IL-12/mg microspheres, 2 mg microspheres/mouse). RESULTS: Successful engraftment of HNSCC was observed in 12 of 19 different patient samples. Normal histological architecture of tumor was maintained up to four serial passages in the SCID mice. After the first tumor engraftment, but not in subsequent passages, human immunoglobulin produced by plasma cells present in the tumor infiltrating lymphocyte population was detected in the mouse sera. Allogeneic human PBL displayed antitumor cytotoxic activity in a cell dose-dependent fashion when coengrafted with the tumors passaged in SCID mice. Lymphocyte subset depletion studies established that tumor suppression was dependent on both the CD8+ T lymphocytes and the CD56+ natural killer cells. Treatment of tumors with a single intralesional injection of IL-12-loaded microspheres was highly effective, resulting in the complete suppression of tumor engraftment in 50% of the mice. In contrast, treatment of tumors with repeated bolus IL-12 injections suppressed tumor engraftment only transiently and did not result in complete tumor rejection in any of the mice. CONCLUSION: The coengraftment of HNSCC and allogeneic lymphocytes into SCID mice provides a viable model with which to evaluate immunotherapeutic strategies for human cancer. The use of biodegradable microspheres for local sustained delivery of cytokines to augment lymphocyte mediated antitumor immunity within the tumor microenvironment provides a safer and simpler alternative to current cytokine immunotherapy protocols.

Animals↗

Effects of cyclical mechanical stress on the controlled release of proteins from a biodegradable polymer implant.

The availability of osteogenic proteins for orthopedic applications has led to great interest in developing delivery systems for these substances. Standard release rate models are applicable in most biological settings, but orthopedic implants usually bear mechanical loads. To determine whether a release rate model for load bearing applications must consider mechanical stress, the effects of dynamic mechanical stress on the in vitro release kinetics of two model proteins, bovine albumin (BA) and trypsin inhibitor (TI), from a biodegradable film were evaluated. Biodegradable poly(lacticco-glycolic acid) cylindrical implants with embedded proteins were subjected to cyclic three point bending loading of 720 cycles/day at 0.4 Hz for 2 weeks. Protein release into solution, swelling and mass loss changes, molecular weight degradation, and the presence of microstructural stress cracks and pores in the polymer carrier were evaluated. Cumulative BA and TI releases with time were significantly higher when a cyclic bending load was applied and increased with the magnitude of the load. Mass loss was not significantly greater, nor was swelling or molecular weight change of the polymer carrier in this 2-week interval. Pores on the surface of the polymer in the highest stress region were elongated into cracks, compared with pores in the low-stress region of the same implant, which were roughly circular. This implies that the pores probably act as stress risers to initiate cracks, which then expose more surface area, increasing protein release.

Animals↗

Biodegradation and biocompatibility of a guided tissue regeneration barrier membrane formed from a liquid polymer material.

Biodegradable barrier films were made by coagulating a solution of poly(DL-lactide) in N-methyl-2-pyrrolidone on porous polyethylene pads wetted with saline solution. The semisolid films were cut into 10 x 10 mm barriers and implanted subcutaneously in rabbits. At monthly intervals, the polymer implant sites were compared histologically to those implanted with USP negative control plastic. The polymer films were retrieved from the surrounding tissue, dried, weighed, and the changes in molecular weight determined using gel permeation chromatography. The molecular weight of the polymer decreased at a relatively constant rate over 5 months; however, no significant mass loss occurred until 5 months postimplantation. Also, no distinct histological differences were noted between the polymer barrier and the control plastic sites until 6 months when histiocytes and multinucleated giant cells showed a modest increase around fragmented polymer films. Similar barrier films also were fitted over naturally occurring buccal dehiscence defects in beagle dogs and the tissue sites compared histologically at 6 months to sham-operated control sites. New bone and dense connective tissues closely approximated segments of the remaining polymer and demonstrated the biocompatibility of the biodegradable films. Histomorphometric analyses of treated sites compared to sham controls showed that the polymer barrier is effective in promoting bone and cementum regeneration in periodontal defects in dogs.

Animals↗

In vitro elution of vancomycin from biodegradable beads.

The current antibiotics delivery system for orthopedic infection treatment uses polymethylmethacrylate (PMMA) beads as a drug release. However the nonbiodegradable nature of the PMMA necessitates a second operation to remove the beads. This article explores the alternative of using biodegradable polymers as antibiotic beads for a long-term drug release. The effect of different processing factors on the release rate of the beads was investigated. To manufacture an antibiotic bead, polylactide-polyglycolide copolymers were mixed with vancomycin. The mixture was compressed and sintered at 55 degrees C to form beads of different sizes. An elution method was employed to characterize the release rate of antibiotic over a 35-day period at 37 degrees C. Biodegradable beads released high concentrations of antibiotic (well above the breakpoint sensitivity concentration) in vitro for the period of time needed to treat bone infection; i.e., 4-6 weeks. A bacterial inhibition test was carried out to determine the relative activity of the released antibiotics. The diameter of the sample inhibition zone ranged from 6.5-10 mm, which is equivalent to 12.5-100% of relative activity. By changing the processing parameters, we were able to control the release rate of the beads. This provides advantages of meeting the specific antibiotics requirement for patients with various surgical infections.

Anti-Bacterial Agents↗

Plant and soil enantioselective biodegradation of racemic phenoxyalkanoic herbicides.

The biodegradation of the chiral phenoxyalkanoic herbicides 2-(2,4-dichlorophenoxy)propionic aid (2,4-DP) and 2-(4-chloro-2-methylphenoxy)propionic acid (MCPP) was investigated using enantioselective HPLC and chiroptical detection. Racemic mixtures of 2,4-DP and MCPP were applied to three species of turf grass, four species of broadleaf weeds, and soil. Preferential degradation of the S-(-) enantiomer of each herbicide was observed in most species of broadleaf weeds and soil, while the degradation in all species of grass occurred without enantioselectivity. The biodegradation in all systems appeared to follow pseudo first-order kinetics with the fastest degradation occurring in broadleaf weeds, followed by the grasses. The slowest degradation was observed in soil. The results of this work illustrate the need to characterize both enantiomers of chiral agrochemicals in order to have an accurate understanding of their distribution and fate in the environment.

2,4-Dichlorophenoxyacetic Acid↗

Modeling substrate interactions during the biodegradation of mixtures of toluene and phenol by Burkholderia species JS150.

The biodegradation kinetics of toluene, phenol, and a mixture of toluene and phenol by Burkholderia species JS150 was measured and modeled. Both of these compounds can serve as the sole source of carbon and energy for this microorganism. The single-substrate biodegradation kinetics was described well using the Monod model, with model constants of mu(max,T) = 0.39 h(-1) and K(S,T) = 0.011 mM for growth on toluene and mu(max,P) = 0.309 h(-1) and K(S,P) = 0.0054 mM for growth on phenol. Degradation of the mixture of toluene and phenol followed simultaneous utilization kinetics with toluene being the preferred substrate. Toluene was found to inhibit the rate of utilization of phenol while the presence of phenol had little effect on the rate of degradation of toluene. Of the kinetic models that were tested, one developed for microbial degradation of multiple substrates was able to describe substrate interactions and to model the mixture utilization by strain JS150. Simple competitive, noncompetitive, or uncompetitive substrate kinetics were not sufficient to describe the observed inhibitory interactions.

Biodegradation, Environmental↗

Study of biodegradation behavior of chitosan-xanthan microspheres in simulated physiological media.

Microspheres of a polyelectrolyte complex hydrogel were prepared from chitosan and xanthan after interaction between the two polyionic polymers. Their biodegradation was studied vs. chitosan. Simulated gastric fluid (SGF, pH 1.2) and intestinal fluid (SIF, pH 7.5) both as biodegradation media and phosphate buffered saline (PBS, pH 7.4) as a negative control were used. The degradation studies were performed at 37 degrees C at 240 rpm permanent stirring to mimic the physiologic conditions. High performance liquid chromatography (HPLC) was carried out to quantify the chitosan degradation products using glucosamine (GA) and N-acetyl-D-glucosamine (N-Ac-GA) as references. The peaks area integration method was used to determine the amount of each degradation product as a function of incubation time in the media. The effect of the media on the morphological structure of microspheres was assessed by scanning electron microscopy. From HPLC studies, it appeared that in SGF and SIF the major degradation products were glucosamine (GA) and N-acetyl-D-glucosamine (NAc-GA). In the first 15 days, oligochitosan fractions were released from the complex, whereas N-acetyl-D-glucosamine was detected in the media after this period. The degradation kinetics were assessed by the measurement of the cumulative degradation products, which showed faster degradation of chitosan than the complex in SGF and SIF. SEM micrographs showed an enhancement of microsphere porosity as a function of incubation time in the simulated physiological media. Our results suggest a better control of the degradation kinetics when chitosan is complexed to xanthan.

Acetylglucosamine↗

Protein-fatty acid complex for enhanced loading and stability within biodegradable nanoparticles.

Lysozyme was hydrophobically modified with a fatty acid, sodium oleate, via an ion-pairing mechanism. Ionic binding between an anionic carboxylic group of sodium oleate and basic amino groups in lysozyme was primarily utilized to form lysozyme-oleate complex. The complex formation was pH dependent. The lysozyme-oleate complex dissolved in an organic solvent exhibited much higher conformational stability at elevated temperature compared with free lysozyme in the same solvent. The complex was formulated into biodegradable nanoparticles by a spontaneous emulsion and solvent diffusion method. The resultant formulation showed near 100% encapsulation efficiency of lysozyme within nanoparticles with < 100 nm in diameter with a narrow size distribution. Lysozyme could be loaded into the nanoparticles up to 18.6% (w/w) with concomitantly increased particle sizes. This study demonstrates a new formulation method of biodegradable nanoparticles with highly efficient encapsulation of proteins, which are potentially useful for oral protein delivery including mucosal vaccination.

Biocompatible Materials↗