PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “DEXTERITY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Neurodevelopmental status at eight years in children with dextro-transposition of the great arteries: the Boston Circulatory Arrest Trial.

OBJECTIVES: Our goal was to determine which of the two major methods of vital organ support used in infant cardiac surgery, total circulatory arrest and low-flow cardiopulmonary bypass, results in better neurodevelopmental outcomes at school age. METHODS: In a single-center trial, infants with dextrotransposition of the great arteries underwent the arterial switch operation after random assignment to either total circulatory arrest or low-flow cardiopulmonary bypass. Developmental, neurologic, and speech outcomes were assessed at 8 years of age in 155 of 160 eligible children (97%). RESULTS: Treatment groups did not differ in terms of most outcomes, including neurologic status, Full-Scale or Performance IQ score, academic achievement, memory, problem solving, and visual-motor integration. Children assigned to total circulatory arrest performed worse on tests of motor function including manual dexterity with the nondominant hand (P =.003), apraxia of speech (P =.01), visual-motor tracking (P =.01), and phonologic awareness (P =.003). Assignment to low-flow cardiopulmonary bypass was associated with a more impulsive response style on a continuous performance test of vigilance (P <.01) and worse behavior as rated by teachers (P =.05). Although mean scores on most outcomes were within normal limits, neurodevelopmental status in the cohort as a whole was below expectation in many respects, including academic achievement, fine motor function, visual-spatial skills, working memory, hypothesis generating and testing, sustained attention, and higher-order language skills. CONCLUSIONS: Use of total circulatory arrest to support vital organs during heart surgery in infancy is generally associated with greater functional deficits than is use of low-flow cardiopulmonary bypass, although both strategies are associated with increased risk of neurodevelopmental vulnerabilities.

Boston↗

Facilitated endoscopic beating heart coronary artery bypass grafting using a magnetic coupling device.

BACKGROUND: Suturing of a coronary anastomosis in totally endoscopic coronary artery bypass grafting on the beating heart is technically demanding. The potential benefits of the endoscopic Magnetic Vascular Positioner device (Ventrica, Inc, Fremont, Calif) to facilitate construction of a coronary anastomosis in a closed chest environment were evaluated. METHODS: Totally endoscopic coronary artery bypass grafting on the beating heart was performed in 8 foxhound-beagle inbred dogs with the da Vinci telemanipulation system (Intuitive Surgical, Mountain View, Calif). A prototype of the endoscopic Magnetic Vascular Positioner device was used to facilitate construction of the coronary anastomosis. One pair of magnets was inserted in the internal thoracic artery and left anterior descending artery using robotic instruments to guide and place the endoscopic delivery platform. All animals underwent angiography; gross inspection of the anastomotic site was performed after excision of the hearts. RESULTS: The procedure was accomplished in all animals in 169 minutes (155-190 minutes). Dissection of the left anterior descending coronary artery (6.5 minutes; 1-20 minutes), positioning of the stabilizer (8.5 minutes; 7-16 minutes), placement of occlusion tapes (6 minutes, 3-10 minutes), and arteriotomy 5.5 minutes (3-30 minutes) was achieved without problems. By use of the Magnetic Vascular Positioner device, the anastomosis at the graft site was performed with the graft still in situ. Except for 1 premature deployment, all other deployments were easily accomplished in 3 minutes (1-28 minutes). The following adverse events were encountered: bleeding from the right ventricle caused by occlusion tape (1), anastomotic leakage on reperfusion requiring repair stitches (2), and anastomotic occlusion as a result of thrombus (1). All except 1 animal with a patent graft and anastomosis survived the procedure. The overall patency was 7 of 8. DISCUSSION: The combination of robotic technology allowing for dexterous manipulation in a closed chest environment and a simple yet effective and timesaving technique for anastomotic coupling may facilitate beating heart totally endoscopic coronary artery bypass grafting.

Anastomosis, Surgical↗

Robotic extraperitoneal radical prostatectomy: an alternative approach.

PURPOSE: Laparoscopic radical prostatectomy with or without a robot has been increasingly performed worldwide, primarily using a transperitoneal approach. We report our experience with daVinci(R) robot assisted extraperitoneal laparoscopic radical prostatectomy. MATERIALS AND METHODS: A total of 325 patients underwent robot assisted extraperitoneal laparoscopic radical prostatectomy for clinically localized prostate cancer at our center during a 2-year period. Perioperative data, and oncological and functional results were prospectively recorded. RESULTS: Perioperative demographics included mean age, PSA and Gleason score, which were 60 years (range 42 to 76), 6.6 ng/ml (range 0.6 to 26) and 6 (range 5 to 9), respectively. Preoperative clinical stage was 81%, 16% and 3% for T1c, T2a and T2b, respectively. Average total operative time was 130 minutes (range 80 to 480). Intraoperative data included a mean blood loss of 196 cc with no open conversions. Bilateral, unilateral and nonnerve sparing prostatectomy was performed in 70%, 24% and 6% of patients, respectively. Of the patients 96% were discharged home within 8 to 23 hours of surgery. Pathological stage was pT2a, pT2b, pT3a and pT3b in 18%, 63%, 14% and 5% of all radical prostatectomy specimens, respectively, with an overall positive surgical margin rate of 13%. Two of 92 patients had positive nodal disease after lymph node dissection. Continence and erectile function were measured. CONCLUSIONS: The extraperitoneal approach offers the advantages of improved dexterity and visualization of the robot, while avoiding the abdominal cavity and potential associated morbidity. As surgeons gain more experience with this new technology, the extraperitoneal approach simulating the standard open retropubic technique is likely to gain popularity.

Adult↗

Synchronous bladder reconstruction and antegrade continence enema.

PURPOSE: We assess the long-term outcome of synchronous bladder reconstruction and antegrade continence enema in a large series of patients. MATERIALS AND METHODS: We retrospectively reviewed records of the last 50 consecutive patients treated at 1 unit in Southampton and 1 in Denver. RESULTS: A total of 46 patients were available for analysis, including 24 from Southampton and 22 from Denver. Median patient age at operation was 12 years (range 4 to 30), median followup was 44 months (range 7 to 100), and 80% of patients had neuropathy and anorectal malformation. A variety of bladder reconstructive procedures were performed and 58% of patients underwent a simultaneous Mitrofanoff procedure. Fecal and urinary continence was achieved in 76% of patients but the rate of revision surgery was high. The most common complication was stomal stenosis (17%). Secondary procedures consisted of refashioning urethral length, closure of the bladder neck, bladder augmentation and conduit revision. CONCLUSIONS: It is now possible to produce double continence in some patients with synchronous combined surgery, a goal that was not achievable without colostomy before the development of the antegrade continence enema in 1990. However, the surgery is demanding with high revision rates and we emphasize that it should only be performed in patients who are highly motivated and have reasonable dexterity and intelligence. This careful patient selection is confirmed by the fact that surgery was performed on 2 to 3 patients a year at each unit. This surgery should only be performed at facilities which can provide long-term patient followup.

Adolescent↗

Use of automatic insulin injector for intracorporeal injection in erectile dysfunction.

Intracorporeal injection of vasoactive drugs for the treatment of impotence may be problematic in patients with limited dexterity or psychogenic inhibitions of self-injection. Already in common use for diabetic patients is an easy-to-use automatic injector device, with rapid and simple loading and operating. This economical and handy gadget is adapted to accept standard disposable syringes. We have found it useful also for painless self-injection of intracorporeal vasoactive drugs for the treatment of erectile dysfunction.

Aged↗

Thrombolytic therapy. Agents, indications, and laboratory monitoring.

The patient must be educated to seek medical attention promptly when this malady strikes, and the physician must likewise be taught to institute this therapy as soon as the patient is seen. Less than 6 years ago, it was strongly expressed that there was no rationale for attempting to restore blood flow in the coronary arteries in the setting of myocardial infarction. It was believed that once the diagnosis of myocardial infarction was made, it was too late to relieve myocardial fibers and avert myocyte necrosis. If this thinking and advice of "the damage has already occurred" and "it is too late" prevailed, it would not be known today that treatment of myocardial infarction with thrombolytic therapy within 6 hours of onset of symptoms significantly reduces mortality in comparison with optimal medical treatment (including heparin) without thrombolytic therapy. The concept of thrombolytic therapy is correct. Persistent investigative work in this area will result in better thrombolytic agents and greater dexterity in their use. The thrombolytic agents available today are good, and they can be used safely. To state that agents that have been established to be capable of thrombus resolution should not be used in the treatment of thrombosis is a true example of how not to proceed toward improvement. To be content to remain in the past will not permit entrance into the future.

Embolism↗

[Adaptation and validation of the Health Utilities Index Mark 3 into Spanish and correction norms for Spanish population].

BACKGROUND AND OBJECTIVE: The Health Utilities Index Mark III (HUI-3) is a psychometric instrument developed to assign utilities to patients' health states. We present its Spanish adaptation and validation. Moreover, we estimate its utility in the Spanish population and compare it to Canadian patients. PATIENTS AND METHOD: The Adaptation process has been carried out following the original protocol by Furlong. A panel of experts was selected in order to warrant the process, the questionnaire translation and the training of interviewers. Two different samples were used: a modelling sample to develop the Multi Attribute Utility function (MAUF) and a directed measure sample to validate the MAUF. Both samples are representative of the Spanish population according to gender and age quota. In order to estimate the utilities associated with each health state, Visual Analogue Scale (VAS) and Standard Gamble (SG) procedures were used. The instrument's dimensionality was assessed by means of Factor Analysis, and the convergent validity was checked against EuroQoL. RESULTS: The HUI-3 Spanish version is feasible (< 2% missing values and 7.34 1.27 minutes completion time) and reliable (Cronbach's (= 0.792 in modelling sample, 0.707 in direct measure sample, and 0.760 as a whole), showing a good test-retest correlation (0.909, p < 0.001). Convergent validity is good (correlation with EuroQoL: within 0.788 and 0.793). Factor solution met 5 factors: Speech & Dexterity, Ambulation & Pain, Vision, Emotion & Cognition, and Hearing. The Spanish and Canadian utility function differed significantly; 0.07 pts, p < 0.001). CONCLUSIONS: This questionnaire can be applied to individuals or collectively, either self-administered or through an interview. Psychometric indexes are good. Differences between Spanish and Canadian utility functions suggest the need of using the specific function for each population.

Adolescent↗

Ideomotor apraxia, visuomotor control and the explicit representation of posture.

Ideomotor apraxia is normally viewed as a disorder of the representation or execution of action. However, the evidence from gesture imitation is that apraxic patients are unable to reproduce the final posture of a gesture but may not show abnormality in movement kinematics. This supports a hypothesis that impaired gesture imitation is due to a deficit in a conceptual representation of body posture rather than indicating a disorder specific to action control. The present study evaluated whether other aspects of apraxic behaviour might also be most consistent with a deficit in the representation of posture. Patients with left hemisphere damage and apraxia on gesture imitation had difficulty in reproducing a series of actions due to failure to adopt the required configuration of the hand whereas there was no consistent reduction in speed of response once the actions had been learned. They also tended to use an abnormal, clumsy grasp when using a spoon but this dissociated from accurate performance on other tests of manual dexterity where there was less scope for variation in configuration of the hand. These data suggest that the most common deficit in ideomotor apraxia is impaired ability to perform tasks where the goal is to reproduce or adopt complex hand configurations and that impaired execution of some types of action is secondary to this problem. This is consistent with a role for the human left parietal lobe in providing an explicit representation of posture which is used to guide some actions and to supplement a more primitive system of direct visuomotor control.

Adult↗

Selective serotonin reuptake inhibitor paroxetine modulates motor behavior through practice. A double-blind, placebo-controlled, multi-dose study in healthy subjects.

We hypothesized that selective serotonin reuptake inhibitors (SSRIs) could modulate motor activity in healthy subjects in a dose-dependent manner. The effects of a single dose of paroxetine were tested in a double-blind, placebo-controlled study. Six randomized and counterbalanced subjects performed behavioral tests in three sessions 1 week apart (E1, E2 and E3) at peak plasma concentration (5 h after drug intake). Each subject was given 20 mg or 60 mg of the drug, or a placebo. Tasks were the Nine Peg Hole test (three trials), Moede dexteritymeter (two trials), and compatible and incompatible reaction time tasks. The results show that at the first trials, performance did not differ after placebo or paroxetine intake. However, 20 and 60 mg of paroxetine improved performance significantly at the third trial of the Nine Peg Hole test and subjects receiving the drug performed 7% faster than those under placebo. An amount of 20 mg, but not 60 mg, of paroxetine improved dexterity significantly at the second trial of the Moede test and subjects performed 30% faster. Conversely, the drug did not affect reaction time for the compatible task and subjects were 11% slower under 20 mg with the incompatible task. Thus, paroxetine decreased the ability to inhibit automatism. Thus, it was concluded that a single dose of paroxetine improved motor performance through practice. But negative effects occurred on tasks including the inhibition of an automatism. Paroxetine enhanced brain motor output (motor activity in S1M1) [NeuroImage, 15 (2002) 26]. This S1M1 hyperactivation is likely to be responsible for the better performance. The brain effect and motor improvement were dose dependent. For both, 20 mg was the optimal dose.

Aged↗

Endoscopy in neuro-otologic surgery.

Endoscopy offers several distinct advantages over the operating microscope during neuro-otologic surgery that make it an excellent adjunctive tool to the microscope or independent modality during cranial base surgery. The high magnification gives excellent definition of perforating blood vessels, cranial nerves, and neural structures, which in many cases is superior to that achieved with the microscope. Furthermore, the use of angled or flexible endoscopes allows one to look around corners and behind anatomic structures blocking the view seen via a 0 degree microscope. Endoscopy also has the theoretical advantage that a less invasive operative procedure is required, which should reduce the operative morbidity. Several notable disadvantages of endoscopy include the problems associated with blood soiling the endoscope, making visualization difficult or impossible, the lack of readily available instrumentation designed specifically for endoscopic neuro-otology, and the poor overview of the operative field. This last point is an important one because the endoscope is placed adjacent to the lesion and does not allow one to look backward to prevent [figure: see text] injury to structures next to the shaft of the telescope. Furthermore, the surgeon must be cognizant of potential thermal injury to structures caused by the heat generated by the light source. The present endoscopic technology limits the image that the surgeon sees to two dimensions, which results in certain unique problems when operating in a three-dimensional milieu. Because of this, there is a steep learning curve to acquire endoscopic dexterity and three-dimensional orientation. Finally, bimanual operation requires the use of an articulated endoscope holder or the commitment of the co-surgeon to hold the endoscope. One of the limitations of the operative microscope is that the angle of view is determined by the distance of the lens to the skull, retractor, or obstructing tissue, which is a function of the lens focal length; the longer the focal length, the narrower the viewing angle. During most microsurgical procedures, the focal distance varies between 200 and 400 mm. Using a previous analogy, if one looks through a door's keyhole at close range, nearly the entire room on the opposite side of the door can be seen, although nothing can be seen when the hole is viewed from a long distance. This is similar to what happens when using the endoscope with focal lengths ranging from 5 to 20 mm: a wider angle of view can be achieved. Based on their, experience the authors believe that endoscopes can be used safely during neuro-otologic surgery. As an adjunct to or substitution for the operative microscope, this modality does improve visualization of bony, neural, and vascular structures while minimizing cerebellar retraction.

Decompression, Surgical↗

Relationships between mood states and performances in reaction time, psychomotor ability, and mental efficiency during a 31-day gradual decompression in a hypobaric chamber from sea level to 8848 m equivalent altitude.

High altitude is characterized by hypoxic environmental conditions that may induce a set of pathological disorders, known as acute mountain sickness. In addition to the physiological symptoms, exposure to high altitude may also produce adverse changes in motor skills, mental efficiency, and mood states, including anxiety. In the present study, we investigated the relationships between mood states, including anxiety, and performance changes in reaction time, psychomotor ability and mental efficiency in eight climbers participating in the 'Everest-Comex 97', a 31-day gradual decompression in a hypobaric chamber from sea level to 8848 m equivalent altitude. Tests of visual reaction time, manual dexterity, and number ordination were used; anxiety responses and mood states were assessed using the Spielberger State-Trait Anxiety Inventory (STAI) and the 'Profile of Mood States' (POMS), respectively. A significant positive correlation was found between the climbers' performance in reaction time and changes in state-type anxiety levels, suggesting that anxiety could lead to an improved reaction time. In addition, significant negative correlations were also found between the climbers' performance in psychomotor ability, mental efficiency, and reaction time, and several POMS factors, including Tension, Hostility, Confusion, and Fatigue. Overall, these data indicate, in agreement with previous studies, that anxiety may favour, or at least not alter, the processes of information of relatively simple tasks, such as reaction time, and further suggest that adverse changes in moods could modulate performance negatively.

Acclimatization↗

Neuromuscular recovery after parathyroidectomy in primary hyperparathyroidism.

BACKGROUND: Primary hyperparathyroidism today is diagnosed in the asymptomatic phase because of the inclusion of serum calcium in sequential multichannel analysis. The purpose of present study was to test for neuromuscular abnormalities in asymptomatic patients and to test the improvement of neuromuscular performance after parathyroidectomy. METHODS: Nine patients with primary hyperparathyroidism and nine patients with nodular goiter were enrolled in this study. Neuromuscular recovery including muscle power, sensation, and fine motor movement was studied before operation and 1 week and 4 weeks after operation. The muscle power was measured as grip power, palm pinch, lateral pinch, and three-chuck pinch. The sensation was measured as touch sensation and two-point discrimination. The fine motor movement was measured with the Purdue Pegboard Test and the Minnesota Manual Dexterity Test. RESULTS: Four weeks after the operation the patients with hyperparathyroidism had increased their muscle strength and had improved fine motor movement but no change was noted in two-point and touch sensation. When the postoperative muscle recovery was compared, there was a reversible correlation (r = -0.62; p < 0.05) with the preoperative muscle strength and no correlation with the preoperative serum calcium, phosphate, alkaline phosphatase, and intact parathyroid hormone levels. No such improvement was detectable among the control subjects. CONCLUSIONS: Surgery can improve muscle strength and fine motor movement but does not affect sensation in asymptomatic patients.

Adult↗

Robot-assisted laparoscopic colorectal surgery.

Colorectal surgery can be difficult at open and laparoscopic surgery. This is particularly the case for rectal surgery deep in the pelvis. In obese males distal rectal dissection can be challenging because of instrument and visual limitations. Robot-assisted laparoscopic colorectal operations do not differ significantly from the standard laparoscopic approach but it has certainly been shown that it is feasible to perform the same operation using robotic assistance for the dissection. This allows the surgeon to benefit from vastly enhanced vision and dexterity, which may ultimately translate into benefit for the patient in terms of reduced operating time, and better preservation of pelvic nerves and other structures.

Colonic Diseases↗

Robotics and general surgery.

Robotics are now being used in all surgical fields, including general surgery. By increasing intra-abdominal articulations while operating through small incisions, robotics are increasingly being used for a large number of visceral and solid organ operations, including those for the gallbladder, esophagus, stomach, intestines, colon, and rectum, as well as for the endocrine organs. Robotics and general surgery are blending for the first time in history and as a specialty field should continue to grow for many years to come. We continuously demand solutions to questions and limitations that are experienced in our daily work. Laparoscopy is laden with limitations such as fixed axis points at the trocar insertion sites, two-dimensional video monitors, limited dexterity at the instrument tips, lack of haptic sensation, and in some cases poor ergonomics. The creation of a surgical robot system with 3D visual capacity seems to deal with most of these limitations. Although some in the surgical community continue to test the feasibility of these surgical robots and to question the necessity of such an expensive venture, others are already postulating how to improve the next generation of telemanipulators, and in so doing are looking beyond today's horizon to find simpler solutions. As the robotic era enters the world of the general surgeon, more and more complex procedures will be able to be approached through small incisions. As technology catches up with our imaginations, robotic instruments (as opposed to robots) and 3D monitoring will become routine and continue to improve patient care by providing surgeons with the most precise, least traumatic ways of treating surgical disease.

Adrenalectomy↗

Robotics and ergonomics.

Industrial robotics have proven the benefit of using an untiring machine to perform precise repetitive tasks in uncomfortable or dangerous for humans environments. Highly skilled surgeons are trained to operate and adapt to difficult conditions. They are even capable of developing intelligent mechanisms to exploit a variety of tactile, visual, and other cues. The robotic systems, however, can enhance the surgeon's capability to perform a wide variety of tasks. They cannot replace the surgeon's problem-solving ability. Instead, they will redefine his role. They will significantly enhance the surgeon's skills and dexterity by providing their complementary capabilities and an ergonomically efficient and more user-friendly working environment.

Cost-Benefit Analysis↗

Robotic coronary artery bypass grafting (CABG)--the Leipzig experience.

Technical and anatomical limitations as well as human factors complicate endoscopic coronary bypass surgery. Computer-enhanced telemanipulation systems overcome some of these shortcomings by restoring the dexterity and precision of a distant operator (surgeon) within a confined space. Endoscopic coronary artery bypass grafting (CABG) has evolved from a merely experimental approach to a clinical concept. Although CABG was initially exclusively performed on the arrested heart, adjunct technologies such as endoscopic vacuum-assisted stabilizers now allow a closed-chest, beating-heart procedure. The development of anastomotic devices, and further refinements in telemanipulator technology, optical systems, and image-guided augmented-reality scenarios will greatly facilitate endoscopic bypass grafting in the future.

Coronary Artery Bypass↗

Robotic cardiac surgery: overview.

Most endoscopic procedures are excisional, not reconstructive or microsurgical, mostly because conventional endoscopic instrumentation lacks dexterity due to long, nonarticulated instruments, a fixed pivot point and counterintuitive movement of the instrument tip, and lack of depth perception. Endoscopic approaches to cardiac surgery have not been successful; however, the development of robotic surgical systems has overcome many limitations of endoscopy. Computer-assisted surgery has created a computerized digital interface between the surgeon's hands and surgical instrument tips and enhances surgical ability, thereby enabling endoscopic microsurgery. Recently, robotic systems have allowed cardiac surgeons to perform minimally invasive endoscopic coronary artery bypass grafting (CABG) and valve procedures. This article summarizes the use of robotics in cardiac surgery and discusses its potential in our specialty.

Cardiac Surgical Procedures↗

The ZEUS robotic system: experimental and clinical applications.

Laparoscopic procedures provide shorter hospitalization, less pain, better cosmetic results, and faster returns to normal than traditional surgery. Surgeons performing them, however, are hampered by lack of tridimensional view and haptic sense, and by remoteness; but this physical gap also allows robotic and computer interfaces. The computer digitizes surgical movements and images and modifies this information to filter out nonfinalized movements such as tremor, increasing dexterity and precision. Digitized information can also be transmitted to remote locations, allowing surgical care in remote or underserved areas, and enhancing surgical education. There are several robotic surgical systems available; this article reviews the experimental and clinical use of the ZEUS robotic system and discusses its possible role in the future operating room.

Animals↗