PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Reproducibility”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Reproducibility of Doppler measurements of blood flow velocity in the uterine and ovarian arteries in premenopausal women.

Intra- and interobserver reproducibility of Doppler measurements of the pulsatility index (PI) and time-averaged maximum velocity (TAMXV) in the uterine and ovarian arteries were evaluated in examinations of healthy premenopausal women. Each woman underwent reproducibility measurements once in the late follicular phase and once in the midluteal phase. Intraobserver repeatability was assessed in examinations of 12 women, three replicate Doppler measurements being made by one observer in the same vessel. Interobserver agreement was assessed by comparing the results of Doppler measurements made by two investigators in 11 women. The intraclass correlation coefficient (Intra-CC) was 0.78 for the TAMXV in the dominant uterine artery in the follicular phase and 0.82 for the PI in the wall of the dominant follicle. For all other measurements the Intra-CC was < 0.75, indicating poor reproducibility. The interclass correlation coefficient (Inter-CC) was > 0.75 (0.79 to 0.88) for the PI and TAMXV in the dominant uterine artery in the follicular phase and for the PI of both uterine arteries in the luteal phase. For all other measurements the Inter-CC was < 0.75.

Adult↗

A validation study on the intraobserver reproducibility of transcranial color-coded duplex sonography velocity measurements.

Transcranial color-coded duplex sonography (TCCD) is a new method for the measurement of angle-corrected intracranial blood velocities. The insonation angle represents the most important technical variable affecting Doppler velocimetry. The present study was designed to evaluate the intraobserver reproducibility of TCCD for repeated examinations of blood velocity in the anterior, middle and posterior cerebral, basilar and vertebral arteries. Three examinations were performed by the same examiner in each of 20 healthy volunteers within 10 days, with a minimal interval of 2 days between two subsequent examinations. The observer was blinded to previous results. The reproducibility was evaluated by calculating the correlation coefficient (r) and the coefficient of variance (CV) of the difference between the values obtained from the second and the third examination vs. the first examination. The results showed good reproducibility of TCCD velocity measurements in all examined arteries: for maximal systolic velocity r was 0.80-0.94 (p < 0.001), and CV was 5.5-9.4%; for maximal end-diastolic velocities r was 0.89-0.94 (p < 0.001), and CV was 6.6-12.2%.

Adult↗

Reproducibility and observer variability of transrectal ultrasound measurements of prostatic volume.

Transrectal ultrasound (TRUS) is an established investigation in benign and malignant prostatic disease though the level of reproducibility of TRUS volume measurements is not known. A group of observers in the UK and the USA who were participating in linked prospective studies of benign prostatic hyperplasia each carried out measurements during real-time scanning and on a series of static TRUS images. Results demonstrated good reproducibility for measurements of antero-posterior, transverse, and longitudinal dimensions of the prostate by an experienced UK urologist; only a minor degree of interobserver variation occurred in measurements made between experienced UK and USA observers. Using static images, USA observers obtained results that were in good agreement, whereas the UK observers, only two of whom used TRUS regularly, were in poor agreement with each other. This study demonstrates a high level of reproducibility for TRUS volume measurements performed by experienced observers.

Adult↗

Reproducibility of extracranial carotid atherosclerotic lesions assessed by B-mode ultrasound: the Atherosclerosis Risk in Communities Study.

The reproducibility in the identification of carotid artery lesions using B-mode ultrasound was studied in a large random sample selected from the Atherosclerosis Risk in Communities (ARIC) Study. Carotid lesions were defined as plaque with or without acoustic shadowing (indicative of mineralization). A weighted kappa (kappa w) statistic was used as a chance-adjusted measure of repeatability. In the ARIC baseline survey, the kappa w values for the assessment of lesions on repeat reading were 0.47, 0.60 and 0.69 in the left common carotid artery, the carotid bifurcation and the internal carotid artery, respectively. In a repeat scanning, the kappa w values ranged from 0.59 to 0.79 in the left carotid segments. The results were similar in the left and right carotid arteries. Covariates (age, race, gender, body mass index, study center) did not influence the reproducibility. Similar results were also found in both the baseline survey and the first follow-up examination. In conclusion, reproducibility in the assessment of carotid lesions by B-mode ultrasound can be achieved in multicenter studies at fair to good levels of agreement.

Aged↗

Reproducibility of metabolite peak areas in 1H MRS of brain.

We studied the reproducibility of metabolite signals (from N-acetyl aspartate [NAA], choline, and creatine) measured with a standard single-voxel proton magnetic resonance spectroscopy technique (PRESS, TE = 135 ms, 8 ml VOI) in vitro and in two groups of normal volunteers. Spectral peak areas were quantified both by integration and by curve-fitting. In the in vitro study, the "between-days" variability (coefficient of variation [CV]) of measurements ranged from 0.9% to 2.3%. In the first group of volunteers (n = 12), single voxel spectroscopic measurements (8 ml VOI, 256 acquisitions [ACQs]) were made from mirror-image parts of the right and left hemispheres on 2 separate days. The "between-days" CV of measurements ranged from 9% to 18% for metabolite areas, and from 10% to 26% for metabolite area ratios. There were no significant differences between quantification method or hemisphere. After checking and optimising the MR scanner performance (in fact, it was virtually optimal), the second group (n = 4) each had six sequential single voxel spectroscopic measurements (each of 64 ACQs) from the right hemisphere (without moving the voxel) on each of 4 separate days. Even when the metabolites were measured from the same place in the same hemisphere sequentially six times in a 20-min period, the "within-run" CVs ranged from 4.4% to 17.2% for metabolite areas and from 9.7% to 17.0% for metabolite area ratios. The between-days CVs for the subjects ranged from 7.7% to 25.8% (metabolite areas) and from 10.1% to 22.6% (metabolite area ratios). The variability is due to a combination of random noise, subject motion, baseline artefacts in the spectra, and uncertainties in repositioning the VOIs. It is likely to represent the best reproducibility possible with 8-ml VOIs in cooperative, healthy volunteers carefully positioned on each occasion in a standard clinical scanner. Changes in metabolite levels in individuals must therefore be of the order of 20-40% before we can be reasonably confident of measuring them. Reproducibility in patients, who may be less cooperative, will probably be no better, and this must be taken into account in the interpretation of MRS studies in patients with brain pathology; for example, stroke, head injury, and tumours.

Adult↗

Improved reproducibility of left atrial and left ventricular measurements by guided three-dimensional echocardiography.

OBJECTIVES: The objective of this study was to determine whether guided three-dimensional echocardiography could improve the reproducibility of left atrial and left ventricular anteroposterior measurements over that of standard unguided two-dimensional echocardiography. BACKGROUND: Although these measurements are standard indexes for evaluating chamber size, their use is limited by significant interobserver variability largely due to variable image plane positioning. To improve measurement accuracy and reproducibility, we have developed a three-dimensional echocardiograph that displays the line of intersection of the real-time image with a previously saved orthogonal reference image. This display shows the relation of the real-time image to anatomic landmarks in its third, nonvisualized dimension and may be used to guide image positioning. METHODS: Three pairs of operators independently performed unguided two-dimensional and guided three-dimensional examinations on three groups of 10 patients each. The left atrium was measured in a plane through the inferior surface of the aortic cusps and the left ventricle in a plane perpendicular to its long axis 1 cm below the mitral leaflet tips. Interobserver variability of these measurements on unguided parasternal long-axis images and on guided short-axis images was assessed. RESULTS: The standard unguided two-dimensional examination was associated with an interobserver variability of 14.6% and 9.1% for atrial and ventricular measurements, respectively. Guided three-dimensional echocardiography significantly reduced interobserver variability to 5.0% and 3.1%, respectively, for the same measurements (p < 0.005 by McNemar's test). CONCLUSIONS: Significant interobserver variability occurs with standard unguided two-dimensional echocardiographic measurement of left atrial and left ventricular dimensions. Guided three-dimensional echocardiography achieves a nearly threefold improvement of reproducibility of these measurements and provides the basis for improved serial evaluation and comparison of atrial and ventricular size by different operators.

Adult↗

Reproducibility of an Italian food frequency questionnaire for cancer studies: results for specific food items.

To evaluate the reproducibility of a quantitative food frequency questionnaire (FFQ) used in a case-control study on cancer of the breast, ovary and digestive tract, we compared the result of a 98-item questionnaire administered twice at an interval of 3-10 months (median = 5.4 months) to 452 volunteers (144 males and 308 females, median age = 50 years) from three Italian provinces (Pordenone, Genoa and Forlí). Spearman correlation coefficients (r) for intake frequency of 87 dietary items ranged from 0.35 ("chicken or turkey, boiled") to 0.84 ("wine"). Most coefficients were between 0.60 and 0.80, only two being below 0.40 and five equal or above 0.80 (mean r = 0.59). The concordance of the two measurements tended to be somewhat better for alcoholic and non-alcoholic beverages, bread, cereals and first courses, fruits and summary questions at the end of each section of the questionnaire than for side dishes, sweets and desserts. Also, the reproducibility of 11 subjective questions, such as those concerning the amount of fat in seasoning and the intake of garlic or salt, seemed to be high. Age, sex, educational level of the volunteers and interval between the two FFQ did not have a large or systematic impact on the concordance of the two measurements. In conclusion, the present study has shown a good level of reproducibility of our questionnaire and has provided a few important hints on ways of improving the description of various food items.

Adult↗

Test-retest reproducibility of optic disk deterioration detected from stereophotographs by masked graders.

PURPOSE: To assess the reproducibility of determining whether an eye has developed optic disk deterioration by the Optic Disc Reading Center (ODRC) in the Ocular Hypertension Treatment Study (OHTS). DESIGN: Test-retest reproducibility study. METHODS: Masked, certified graders at the ODRC determine the occurrence of optic disk deterioration in OHTS by comparing baseline with follow-up stereoscopic optic disk photographs. To assess reproducibility, re-gradings were obtained annually by inserting masked "quality control" photographs into the usual ODRC reading stream. RESULTS: Agreement (kappa) ranged from 0.65 to 0.83 over 5 years. Specificity ranged from 98% to 100%, and sensitivity ranged from 64% to 81%. CONCLUSIONS: The kappa statistic for test-retest agreement in OHTS is in the range considered good to excellent over 5 years. Consistency (specificity) in re-grading optic disks that did not develop deterioration was particularly high. The sensitivity results show that detecting subtle deterioration of optic disks is challenging.

Glaucoma, Open-Angle↗

[Novel Doppler indexes of estimation of pulmonary capillary pressure: influence of age, feasibility in the acute setting and reproducibility].

BACKGROUND: The Doppler indexes E/Vp, E/Ea, 1000/(2 x IRT + Vp), 1000/(2 x IRT + Ea) and DTd (E: peak E mitral velocity; Vp: flow propagation velocity by color M-mode; Ea: peak early diastolic velocity at lateral mitral annulus by tissue Doppler; IRT: isovolumic relaxation time; DTd: deceleration time of the pulmonary venous diastolic wave) have been proposed for the non-invasive prediction of left ventricular filling pressures. However, the influence of age, the feasibility in acute setting and the reproducibility of these Doppler indexes have never been simultaneously investigated. OBJECTIVE: The present study was conducted to evaluate the influence of age in 56 healthy subjects (57 +/- 20 years of age), the feasibility in 40 critically ill patients (72 +/- 13 years of age; 21 with decompensated heart failure) and the reproducibility in 15 patients. RESULTS: Only the indexes E/Vp (R = 0.37, P = 0.005) and E/Ea (R = 0.72, P < 0.001) were correlated with age. The feasibility was 92, 90, 72, 72 and 45% for E/Ea, 1000/(2 x IRT + Ea), E/Vp, 1000/(2 x IRT +Vp) and DTd, respectively. The best reproducibility was observed for the Doppler parameters E and Ea. CONCLUSION: Despite it is influenced by age, E/Ea appears to be the most useful index for predicting left ventricular filling pressures routinely.

Adolescent↗

Reproducibility of walking at self-preferred and maximal speed in patients with postpoliomyelitis syndrome.

OBJECTIVE: To assess the reproducibility of walking performance, heart rate, and perceived exertion at self-preferred speed and maximal walking speed in patients with the postpoliomyelitis syndrome (PPS). DESIGN: Repeated measurement at a 3-week interval. SETTING: University hospital. PARTICIPANTS: Convenience sample of 65 patients with PPS. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Walking performance: the distance walked in 2 minutes at a self-preferred speed and the time needed to walk 75 m at maximal speed, heart rate, and rating of perceived exertion (RPE) on an 11-point scale. RESULTS: Test-retest reliability of walking performance was excellent for both tests (intraclass correlation coefficient [ICC] range, .94-.97). No systematic differences existed between test and retest. The smallest detectable change for an individual was 15% for both tests. Test-retest reliability for heart rate was good (ICC=.86) but moderate for RPE (Spearman rho range, .67-.70). The smallest detectable change for RPE was between 4 and 6 scale points. The variability in walking performance was significantly correlated with the variability in heart rate at self-preferred speed (r =.36, P <.01) but not with the variability in RPE (r =.20, P =.11). CONCLUSIONS: Both walking tests showed good reproducibility and may be appropriate to monitor (individual) changes in walking capacity in patients with PPS. Because of its moderate reproducibility, RPE does not seem to be suitable to monitor physical exertion. The usefulness of an objective measure such as heart rate for this purpose needs further investigation.

Female↗

Energy demands of walking in persons with postpoliomyelitis syndrome: relationship with muscle strength and reproducibility.

OBJECTIVES: To describe the energy demands of walking in subjects with postpoliomyelitis syndrome (PPS) in comparison with the demands in healthy subjects, and to assess the reproducibility of walking energy measurements. DESIGN: Four repeated measurements with a 1-week interval between each measurement. SETTING: Outpatient clinic of a university hospital. PARTICIPANTS: Fourteen subjects with PPS and 14 age- and sex-matched healthy subjects. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Walking speed and energy cost of walking. The correlation parameter was lower-extremity muscle strength sum (MSS). The reproducibility parameters were standard error (SE) of measurement and smallest detectable difference (SDD). RESULTS: Walking speed in subjects with PPS (61.8 m/min) was significantly lower (-28%) and energy cost (4.8 J.kg(-1).m(-1)) was significantly higher (40%) than in healthy subjects. MSS correlated strongly with energy cost (r=-.84, P=.000), explaining 71% of the variance. The SE of measurement of energy cost measurements ranged between 1.7% and 3.4% for PPS subjects and between 1.2% and 2.4% for healthy subjects. The SDD ranged between 4.6% and 9.4% for PPS subjects and between 3.3% and 6.6% for healthy subjects, depending on the number of repeated measurements that were considered. CONCLUSIONS: Energy cost of walking in subjects with PPS is strongly related to the extent of muscle weakness in the lower extremities. Although variability was greater for PPS subjects than for healthy subjects, reproducibility of energy cost measurements was high. Therefore, metabolic assessment of energy cost of walking is a sensitive tool that can reveal clinically relevant changes even in the condition of a person with PPS.

Adult↗

Inter-study reproducibility of 3D volume selective fast spin echo sequence for quantifying carotid artery wall volume in asymptomatic subjects.

PURPOSE: To determine, in asymptomatic subjects, the inter-study reproducibility of a three-dimensional (3D) volume selective fast spin echo (FSE) cardiovascular magnetic resonance sequence for the assessment of carotid artery wall volume as a measure of atheroma burden. METHODS: Inter-study reproducibility was evaluated in 16 asymptomatic volunteers (10 male, 6 female). Both carotid arteries were scanned twice with a median inter-scan time of 5 days. The images were acquired in cross-section, and the total carotid arterial wall volume (TWV) was calculated by subtraction of the total carotid lumen volume from the total outer carotid vessel volume. RESULTS: The mean carotid T1-weighted TWV for the first and second scans was 828 and 821 mm(3), respectively (mean difference 7 mm(3), p=0.45). The standard deviation (S.D.) of the differences between the measurements was 38 mm(3) yielding an inter-study coefficient of variation of 4.6%. The time for each study was approximately 30 min. For the longitudinal evaluation of carotid atheroma burden with pharmacological intervention versus placebo, 32 subjects would enable a difference of 38 mm(3) to be detected with a significance level of 5% with 80% power. CONCLUSION: Volumetric analysis with carotid CMR in asymptomatic subjects using a 3D volume-selective FSE is time-efficient with good inter-study reproducibility, and is well suited for longitudinal studies of carotid atheroma with reasonable sample sizes.

Adult↗

Test-retest reproducibility of 50 kHz linear-electrical impedance myography.

OBJECTIVE: Electrical impedance myography (EIM) is a method for evaluating muscle in which high-frequency, low-intensity alternating current is applied to a body region and the resulting surface voltage pattern over a muscle of interest is measured. In this study, the reproducibility for the simplest of these techniques, 50 kHz linear-EIM, was assessed for three muscles. METHODS: Fifty kilohertz linear-EIM was performed on the biceps, quadriceps, and tibialis anterior of 30 normal subjects ranging in age from 21 to 90 years, and the major outcome variable, the spatially averaged phase (thetaavg), measured. The measurements were repeated within 250 days and comparisons between the two data sets made. RESULTS: Reproducibility, as measured by the intraclass correlation coefficients for all three muscles, was very high at 0.970, 0.971, and 0.938 for biceps, quadriceps, and tibialis anterior, respectively. Variability between measurements was on average 4.2% for all muscle combined, with an upper limit of 16.8%. CONCLUSIONS: Fifty kilohertz linear-EIM demonstrates excellent test-retest reproducibility. SIGNIFICANCE: These results support the view that 50 kHz linear-EIM has the potential to be used as a simple, fast, and non-invasive measurement for the assessment of disease status, either as part of individual patient care or as a surrogate outcome measure in clinical trials work.

Adult↗

Verification films: a study of the daily and weekly reproducibility of breast patient set-up in the START trial.

AIMS: Verification of patient position in radiotherapy by the use of portal images is a current practice in most radiotherapy departments. All patients within the Standardisation of Breast Radiotherapy Trial (START) were required to have on-treatment verification images. Measurements of maximum lung and breast depth from these were used to provide details for the case-report forms. This study was undertaken to validate these measurements, assess the reproducibility of patients' set-up within the START trial and to compare reproducibility on a day-to-day basis with reproducibility over a longer period. Analysis also included a subjective assessment of image quality. MATERIALS AND METHODS: Fifty-three patients from 29 departments were studied. Some centres used electronic portal imaging and others used film. Where film verification was the method of choice, information was collected about the type of film and cassette used. RESULTS: The correlation coefficients for inter- and intra-observer variability of breast and lung depth were 0.99. Comparing maximum breast depth on weekly and daily images, the median per cent standard deviation of breast depth was 4% and 3%, respectively. The mean standard deviation of breast depth for all patients, which gives an indication of the individual patient variability, was 5.5 +/- 2.2 mm for weekly and 3.9 +/- 1.5 mm for daily measurements. For lung depth, mean standard deviation was 6.8 +/- 2.5 mm for weekly and 6.8 +/- 2.8 mm for daily measurements. Images taken using Kodak X-omat V film were inferior to those taken with films in corresponding cassettes. CONCLUSION: Differences between lung depth measured in simulator and on the treatment unit were evident for many patients. There was little difference in the standard deviations of breast and lung depth for daily and weekly verification films on the treatment machine.

Breast Neoplasms↗

Reproducibility assessment of tigecycline MIC results by broth microdilution methods using commercially prepared dry-form panels.

We assessed the reproducibility of tigecycline and piperacillin/tazobactam MIC results tested by broth microdilution methods on commercially prepared dry-format panels. Fifteen bacterial isolates were tested 3 times daily for 3 days for a total of 9 replicate results per strain. The within-day and between-days reproducibility was 100% for tigecycline at +/-1 log(2) dilution step and >98% for piperacillin/tazobactam at +/-1 log(2) dilution step. Identical MIC results were observed for 84.4% and 78.7% of tests for same-day replicates for tigecycline and piperacillin/tazobactam, respectively. These results demonstrate the excellent reproducibility of in vitro susceptibility tests for both tigecycline and piperacillin/tazobactam using a commercially prepared dry-form broth microdilution MIC panel.

Anti-Bacterial Agents↗

Accuracy, reproducibility, and comparability of Doppler tissue imaging by two high-end ultrasound systems.

INTRODUCTION: Doppler tissue imaging is a new technology for quantitative evaluation of myocardial motion and contractility, and is available in several ultrasound systems. This study evaluates the comparability, accuracy, and reproducibility of measurements of velocity, strain rate, and strain by two high-end ultrasound systems. METHODS: Accuracy was assessed by imaging a tissue-mimicking gelatin phantom, and the comparability of measurements in the right ventricular free wall and interventricular septum was assessed in 20 healthy participants. Reproducibility was evaluated by repeated recordings in vitro and in a random subset of patients. RESULTS: In vitro, a high degree of accuracy was found in both systems, with one system measuring slightly lower values than the reference values (mean difference 0.35 +/- 0.18 cm/s, P < .001). Values higher than the reference values were measured by both systems for strain and strain rate. In vivo, no systematic differences in measured velocities, strain rate, and strain were found; however, wide limits of agreement were seen for strain and strain rate. Measurements of tissue velocity, strain, and strain rate were well reproducible, nevertheless wide variation was found in both systems (coefficient of variation = 9%-19%). CONCLUSION: For clinical purposes, both systems have sufficient accuracy for measurements of tissue velocity. The variation in measurements of strain rate and strain by Doppler tissue imaging should be taken into account when designing studies using this new technology. Approaches to potentially reduce this variation should be addressed in future studies.

Echocardiography, Doppler↗

Effect of tissue harmonic imaging and contrast upon between observer and test-retest reproducibility of left ventricular ejection fraction measurement in patients with heart failure.

AIMS: To investigate the effects of tissue harmonic imaging (THI) and contrast chamber opacification (LVO) upon measurement variability and reproducibility of echocardiographic left ventricular (LV) volume and ejection fraction (EF) measurements in patients with heart failure (HF). BACKGROUND: Echocardiography is often used in HF patients to determine LV volumes and EF. However, current echo methods are variable and may not be applicable for repeat testing in individual patients. THI and LVO have both been shown to improve endocardial visualisation, but it remains to be determined whether this results in better measurement reproducibility. METHODS: Thirty-one HF patients and 30 control subjects underwent echocardiography on two separate days. LV volumes were measured under four different imaging conditions: fundamental, THI, LVO and LVO with ECG-triggered Power Doppler. Chamber opacification, pulmonary transit time (PTT), endocardial enhancement, reproducibility and bias were assessed. RESULTS: Chamber opacification was inferior and the PTT longer in the HF patients. PTT was related to LV volumes, EF, jugular venous pressure and mitral filling pattern. THI improved endocardial visualisation, and although LVO improved endocardial visualisation in the controls, it offered no benefit over THI in the HF patients. LV volumes and EF were different for each method and THI was the least variable method for repeat measurements. CONCLUSIONS: THI improved endocardial visualisation and was the least variable of the techniques. LVO offered no further advantage in patients with HF and thus cannot be routinely advocated and since LV volumes and EF were different for each, these methods are neither comparable nor interchangeable for follow-up assessments.

Contrast Media↗

Doppler myocardial imaging in adult male rats: reference values and reproducibility of velocity and deformation parameters.

AIM: Limited data are available about the use of Doppler myocardial imaging (DMI) in small animals. We intend to provide reference values for velocity, strain and strain rate in a large group of healthy rats and studied the reproducibility and repeatability of these parameters. METHODS AND RESULTS: A total of 33 male Wistar rats (503+/-41g) underwent baseline transthoracic echocardiography with DMI of the anterior and inferior wall in a short-axis view using a 13MHz linear probe. Adequate tissue Doppler measurements could be obtained in 30 rats. On average 10+/-4 consecutive cycles were studied in post-processing using dedicated software (SPEQLE). Mean radial peak systolic velocity, strain and strain rate were respectively -0.8+/-0.3cm/s, 38+/-8% and 9.1+/-2.0/s in the anterior wall and 3.1+/-0.6cm/s, 49+/-10% and 13.7+/-3.7/s in the inferior wall. The reproducibility and repeatability of the DMI measurements assessed in 10 rats was good. CONCLUSION: DMI is feasible and reproducible in healthy rats. Establishing reference values opens new perspectives towards the use of strain and strain rate imaging in small rodents in the assessment of myocardial diseases.

Animals↗