PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ULTRASONICS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

A comparison of laser-ultrasound detection system sensitivity with a broad-band ultrasonic source for biomedical applications.

BACKGROUND: Laser ultrasound detection systems are used for noninvasive imaging of internal structures and function of soft tissues. The detection systems with a high sensitivity can be used for detecting small tumors located deeply in human tissues, such as the breast. In this study, the sensitivity of existing ultrasonic detection systems has been compared experimentally by using thermoelastic waves as a broadband ultrasonic source. METHODS: For the comparison, an optical stress transducer, a polyvinylidene difluoride (PVDF) sheet and a calibrated PVDF needle hydrophone were used. To ensure that all detection systems were interrogated by the same ultrasonic field, a small optical instrument was constructed to fix the generating laser head. The sensitivity was evaluated by measuring signal-to-noise ratios (SNRs) and noise equivalent pressures (NEPs). RESULTS: The PVDF system, with a 4 kPa NEP, has a 22-dB better performance than the optical stress transducer. The optical stress transducer showed nearly the same sensitivity as the hydrophone for detecting ultrasound waves at a 1-cm distance. CONCLUSIONS: PVDF detection system provides a useful tool for imaging of soft tissues because of its high sensitivity and broadband detection range.

Biomedical Technology↗

Use of ultrasonic vocalizations to assess olfactory detection in mouse pups treated with 3-methylindole.

Altricial mammals use olfaction long before the olfactory bulb has reached its anatomically mature state. Indeed, while audition and vision are still not functional, the olfactory system of newborn animals can clearly process distinct odorant molecules. Although several previous studies have emphasized the important role that olfaction plays in early critical functions, it has been difficult to develop a sensitive and reliable test to precisely quantify olfactory ability in pups. One difficulty in determining early sensory capabilities is the rather limited behavioral repertory of neonates. The present study examines the use of ultrasonic vocalizations emitted by isolated rodent pups as a potential index of odor detection in newborn mice. As early as postnatal day 2, mice reliably decrease their emission of ultrasonic calls in response to odor exposure to the bedding of adult male mice but not in response to clean bedding odors or to non-social odorant molecules. A toxin known to damage the olfactory epithelium in adult, the 3-methylindole, impairs the ultrasonic call responses triggered by exposure to male bedding, thus confirming the efficiency of this olfactotoxin on mice pups. The administration of 3-methylindole severely reduced the life expectancy of the majority of subjects. This result is discussed according to the critical role of olfaction in nipple-seeking behavior in mouse pups.

Animals↗

Ultrasonic deposition of cells on a surface.

Bacteria in water have been driven to a glass surface by an ultrasonic standing wave. On an antibody coated surface capture of Bacillus subtilis var niger (BG) spores (6.6 x 10(6) ml(-1)) was increased more than 200-fold over above the efficiency in the absence of ultrasound. In microfluidic (non-turbulent) systems detection of particles by sensors operating at a surface is diffusion limited. This results in very low detection abilities particularly for particles with diameters greater than 1 microm. Ultrasound is used here to drive bacterial spores to a wall and overcome this limitation. The results confirm: (1) pressure nodes can be formed close to the water-glass interface when the glass thickness is near half the ultrasonic wavelength; (2) the antibody used was able to capture spores in the presence of an ultrasonic standing wave.

Bacillus subtilis↗

Endoscopy-assisted ultrasonic surgical aspiration of axillary osmidrosis: a retrospective review of 896 consecutive patients from 1998 to 2004.

Axillary osmidrosis is a distressing and troublesome problem that causes a serious handicap in personal and social life. Many different methods have been introduced to treat axillary osmidrosis, however, they are often accompanied by marked complications. We analysed our experiences using endoscopy-assisted ultrasonic surgical aspiration in treating the axillary osmidrosis. From June 1998 to February 2004, a total of 896 patients (562 females, 334 males) were treated for axillary osmidrosis using endoscopy-assisted ultrasonic surgical aspiration. Our method was satisfactory in 815 patients (91%) and recurrence of odour occurred only in 29 (3.2%) patients. It also showed complications in 28 (3.1%) patients. Our method leaves a small inconspicuous scar and no contracture of the axillary skin after a short and comfortable recovery period and maintains normal axillary hair growth patterns. Axillary osmidrosis can be best treated by endoscopy-assisted ultrasonic surgical aspiration and this operation has many advantages with a high success rate, a low complication rate, and a rapid recovery period.

Adolescent↗

A randomised trial of ultrasonic dissection versus electrocoagulation to reduce lymphatic complications after surgery for recurrent sapheno-femoral incompetence.

OBJECTIVE: Prospectively to compare lymphatic drainage after ultrasonic dissection, an electrocoagulation technique and sharp dissection in the groin during surgery for recurrent sapheno-femoral incompetence. DESIGN: Prospective, randomised study comparing three surgical techniques. METHODS: Thirty-six consecutive patients undergoing surgery for recurrent sapheno-femoral incompetence were randomised. Twelve patients underwent dissection with ultrasound, 12 with electrocoagulation and 12 controls had sharp dissection with ligation of scar and lymphatic tissue using absorbable suture material. RESULTS: The mean drain output per patient was 13.5 ml in the ultrasonic group, 15.4 ml in the electrocoagulation group and 8.3 ml in the suture ligation group. Six minor cases of lymphatic leakage occurred in the ultrasonic group. This resulted in no clinical problem. There were no other significant differences between the three groups. CONCLUSIONS: There is no detectable advantage for the use of ultrasound or electrocoagulation in recurrent saphenous high ligation compared to sharp dissection.

Adult↗

Intelligibility of bone-conducted ultrasonic speech.

Ultrasound can be perceived through bone conduction by the profoundly deaf as well as by normal-hearing subjects. Moreover, speech signals modulated onto ultrasound can be detected through bone conduction. This study explored how well listeners can understand ultrasonic speech and the confusion patterns to evaluate and improve bone-conducted ultrasonic hearing. The intelligibility of Japanese words classified by familiarity and Japanese monosyllables with bone-conducted ultrasound was investigated. Results showed that the intelligibility of familiar words was higher than that of unfamiliar words. Further, the results of a monosyllable intelligibility test with bone-conducted ultrasound and those of a test with air-conducted sound showed a similar pattern of speech recognition with regard to the errors made. The relationship between speech intelligibility and sound level showed that the increase in the intelligibility of bone-conducted ultrasonic speech did not exceed the increase in the intelligibility of air-conducted speech as the sound level rose.

Adult↗

Ultrasonic surgery--an alternative way in orthognathic surgery of the mandible. A pilot study.

The aim of this report is to present preliminary results and experiences using an ultrasonic bone-cutting device in bilateral sagittal split osteotomies of the mandible (BSSRO) with particular attention to possible damages to the inferior alveolar nerve (IAN). Seven patients with class II or class III malocclusion were treated by BSSRO with a conventional combined orthognathic and surgical approach. The osteotomy was carried out using an ultrasonic bone-cutting device. Subjective neurosensory deficits of the inferior alveolar nerve were assessed on 14 sides. Compared to the conventional techniques using saws, chisels and burs, the use of the ultrasonic device was more time-consuming, but the osteotomies were carried out at a high level of precision. In addition, this procedure offered the advantage of a blood-free surgical field and thus provided good control of the surgical procedure. Subjective neurosensory disturbances of the IAN showed a continuous decrease from 57.1% (eight sides) 2 months after the surgical procedure to 14.3% (2 sides) after 5 months and to 7.1% 7 months after BSSRO. Within the seven patients of this pilot study associated neurosensory disturbances were low. A possible advantage in terms of nerve protection is subject to a prospective study.

Adolescent↗

Evaluation of melt granulation and ultrasonic spray congealing as techniques to enhance the dissolution of praziquantel.

Praziquantel (PZQ), an anthelminthic drug widely used in developing countries, is classified in Class II in the Biopharmaceutics Classification Systems; this means that PZQ has very low water solubility and high permeability, thus the dissolution is the absorption rate-limiting factor. The aim of this work was to evaluate the suitability of melt granulation and ultrasonic spray congealing as techniques for enhancing the dissolution rate of PZQ. Granules in high shear mixer were prepared by melt granulation, using polyethylene glycol 4000 or poloxamer 188 as meltable binders and alpha-lactose monohydrate as a filler. Quite regularly shaped granules having main size fraction in the range 200-500 microm were obtained using both formulations; however, only poloxamer 188 granules demonstrated a significant (P=0.05) increase of the PZQ dissolution rate compared to pure drug. To evaluate the potential of ultrasonic spray congealing, Gelucire 50/13 microparticles having different drug to carrier ratios (5, 10, 20 and 30%, w/w) were then prepared. The results showed that all the microparticles had a significant higher dissolution rate (P=0.05) respect to pure PZQ. The increase of the PZQ content considerably decreased the dissolution rate of the drug: 5 and 10% PZQ loaded systems evidenced dissolution significantly enhanced compared to 20 and 30% PZQ microparticles. The microparticle's characterisation, performed by Differential Scanning Calorimetry, Hot Stage Microscopy, X-ray powder diffraction and FT-Infrared analysis, evidenced the absence of both modifications of the solid state of PZQ and of significant interactions between the drug and the carrier. In conclusion, melt granulation and ultrasonic spray congealing could be proposed as solvent free, rapid and low expensive manufacturing methods to increase the in vitro dissolution rate of PZQ.

Calorimetry, Differential Scanning↗

Le Fort I osteotomy using an ultrasonic bone curette to fracture the pterygoid plates.

PURPOSE: The purpose of this study was to evaluate the advantageous use of an ultrasonic bone curette and to assess the mobilization of the pterygoid process after a Le Fort I osteotomy. MATERIAL AND METHODS: 14 Japanese adults (ranging in age from 17 to 30 years, mean 22.4) with jaw deformities diagnosed as mandibular prognathism or bimaxillary asymmetry underwent Le Fort I osteotomy with bilateral sagittal split ramus osteotomy or intraoral vertical ramus osteotomy. During the Le Fort I osteotomy, the Sonopet UST-2000 ultrasonic bone curette was used to fracture the pterygoid process slightly above the level of the maxillary osteotomy without damaging the descending palatine artery or other blood vessels and nerves. After surgery, the pterygoid process osteotomy and its mobility were evaluated from three-dimensional computed tomographic images. RESULTS: In all cases, the mobility of the pterygoid process could be achieved by using the device safely with minimal bleeding and no notable complications. The maxillary segment could be fixed in an ideal position and in all 14 cases, an ideal profile was achieved. CONCLUSION: Ultrasonic bone curette offers a safe procedure for performing pterygoid process fractures without damaging the surrounding tissue such as the descending palatine artery.

Adolescent↗

Soil remediation by an advanced oxidative method assisted with ultrasonic energy.

A new process for the remediation of soil contaminated with hydrocarbons is proposed. The innovation consists on coupling an advanced oxidative method, using a Fenton-type catalyst, with the application of ultrasonic energy. The use of ultrasonic energy not only assists the desorption of the contaminants from the soil, but also promotes the formation of OH radicals, which are the oxidant agents involved in the oxidation process. Different Fenton-like catalysts were employed in the present study; however, the highest removal of toluene and xylenes were obtained with iron sulfate and copper sulfate, respectively. Also, hydrogen peroxide was tested at different concentrations, and it was found that increasing its concentration enhanced the removal of all the contaminants. Finally, it was demonstrated that applying ultrasonic energy to the reacting system process noticeably enhanced the global efficiency of the process due to a synergistic effect in conjunction with the hydrogen peroxide concentration and type of catalyst.

Environmental Pollution↗

The effect of ultrasonic post instrumentation on root surface temperature.

This study measured root surface temperature changes when ultrasonic vibration, with and without irrigation, was applied to cemented endodontic posts. Twenty-six, extracted, single-rooted premolars were randomly divided into two groups. Root lengths were standardized, canals instrumented, obturated, and posts cemented into prepared spaces. Thermocouples were positioned at two locations on the proximal root surfaces. Samples were embedded in plaster and brought to 37 degrees C in a water bath. Posts were ultrasonically vibrated for 4 minutes while continuously measuring temperature. Two-way ANOVA compared effects of water coolant and thermocouple location on temperature change. Root surface temperatures were significantly higher (p < 0.001) when posts were instrumented dry. A trend for higher temperatures was observed at coronal thermocouples of nonirrigated teeth and at apical thermocouples of irrigated teeth (p = 0.057). Irrigation during post removal with ultrasonics had a significant impact on the temperature measured at the external root surface.

Bicuspid↗

Overt behavior and ultrasonic vocalization in a fear conditioning paradigm: a dose-response study in the rat.

The behavioral analysis of laboratory rats is usually confined to the level of overt behavior, like locomotion, behavioral inhibition, instrumental responses, and others. Apart from such visible outcome, however, behaviorally relevant information can also be obtained when analyzing the animals' ultrasonic vocalization, which is typically emitted in highly motivational situations, like 22-kHz calls in response to acute or conditioned threat. To further investigate such vocalizations and their relationship with overt behavior, we tested male Wistar rats in a paradigm of Pavlovian fear conditioning, where a tone stimulus (CS) was preceding an aversive foot-shock (US) in a distinct environment. Importantly, the shock dose was varied between groups (0-1.1 mA), and its acute and conditioned outcome were determined. The analysis of visible behavior confirms the usefulness of immobility as a measure of fear conditioning, especially when higher shock doses were used. Rearing and grooming, on the other hand, were more useful to detect conditioned effects with lower shock levels. Ultrasonic vocalization occurred less consistently than changes in overt behavior; however, dose-response relationships were also observed during the phase of conditioning, for example, in latency, call rate and lengths, intervals between calls, and sound amplitude. Furthermore, total calling time (and rate) were highly correlated with overt behavior, namely behavioral inhibition as measured through immobility. These correlations were observed during the phase of fear conditioning, and the subsequent tests. Importantly, conditioned effects in overt behavior were observed, both, to the context and to the CS presented in this context, whereas conditioned vocalization to the context was not observed (except for one rat). In support and extent of previous results, the present data show that a detailed analysis of ultrasonic vocalization can substantially broaden and refine the spectrum of analysis in behavioral work with rats, since it can provide information about situational-, state-, and subject-dependent factors which are partly distinct from what is visible to the experimenter.

Acoustic Stimulation↗

Effects of ultrasonic root end preparation on resected root surfaces: SEM evaluation.

OBJECTIVE: The purpose of this study was to investigate the in vitro effect of ultrasonic retrotips on root end surfaces. STUDY DESIGN: Root end resection was performed on 45 single-root teeth endodontically treated after extraction. Setting the ultrasonic device at full power, a retrograde cavity was made by a stainless steel tip in 9 specimens (SS-FP). In another 9 samples a diamond tip was used (D-FP). Setting the intensity of the ultrasonic device at half power, 9 specimens were treated using stainless steel tips (SS-HP) and 9 using diamond tip (D-HP). Nine teeth were only apically resected and used as controls. Histologic serial sections were examined by scanning electron microsope to assess the number of root-face cracking, the marginal quality, and the crack type. RESULTS: No significant difference between diamond and stainless steel groups was found at a given power setting. Significant differences were found between SS-FP and SS-HP group for both the number of cracks and the marginal quality.

Adolescent↗

Non-linear filtering of ultrasonic signals using neural networks.

Structure noise from inhomogeneous micro-structures makes the detection of flaws present in highly scattering materials difficult. Several techniques have been applied to improve the signal-to-noise ratio (SNR) in order to make flaw detection easier. Linear filtering does not provide good results because both structure noise and flaw signal concentrate energy in the same frequency band. Non-linear filtering can be used to reduce the structure noise of ultrasonic signals. Therefore, neural networks are applied in this work for this purpose. In order to use neural networks for non-linear filtering, dynamic structures must be applied. The easiest way to implement a neural network with the capability of processing temporal patterns is to consider them spatial ones, applying the signal into a tapped delay line of finite extension, that is the input of a static neural network (for example, a multi-layer perceptron). In this work, a dynamic neural network has been built to filter ultrasonic signals with structure noise, and has been trained with the real-time back-propagation algorithm, using as inputs 3000 synthetic ultrasonic signals of 896 samples each. Target signals for training are the same as the ones used as inputs but without noise. The neural network is trained in order to generate as output the target signal when the noisy input one is applied. For testing the performance of the non-linear filter, a new set of 500 noisy signals has been used. The SNR improvement is about 6 dB average. The results show that this non-linear filtering method is quite useful as pre-processing stage in flaw detection systems.

Algorithms↗

A methodology for structural health monitoring with diffuse ultrasonic waves in the presence of temperature variations.

Diffuse ultrasonic waves for structural health monitoring offer the advantages of simplicity of signal generation and reception, sensitivity to damage, and large area coverage; however, there are the serious disadvantages of no accepted methodology for analyzing the complex recorded signals and sensitivity to environmental changes such as temperature and surface conditions. Presented here is a methodology for applying diffuse ultrasonic waves to the problem of detecting structural damage in the presence of unmeasured temperature changes. This methodology is based upon the prediction and observation that the first order effect of a temperature change on a diffuse ultrasonic wave is a time dilation or compression. A multi-step procedure is implemented to (1) record a set of baseline waveforms from the undamaged specimen at temperatures spanning the expected operating range, (2) select a waveform from the baseline set whose temperature is the closest to that of a subsequently measured signal, (3) adjust this baseline waveform to best match the signal, and (4) calculate an error parameter between the signal and the adjusted waveform and compare this parameter to a threshold to determine the structural status. This procedure is applied to experimental data from aluminum plate specimens with artificial flaws. Probability of detection and the minimum flaw size detected are presented as a function of the size of the baseline waveform set. It is shown that a probability of detection of over 95% can be achieved with a small number of baseline waveforms.

Environmental Monitoring↗

A novel ultrasonic micro-dissection technique for biomedicine.

Molecular techniques are transforming our understanding of cellular function and disease. However, accurate molecular analysis methods will be limited if the input DNA, RNA, or protein is not derived from pure population of cells or is contaminated by the wrong cells. A novel Ultrasonic Vibration Micro-dissection (UVM) method was proposed to procure pure population of targeted cells from tissue sections for subsequent analysis. The principle of the ultrasonic vibration cutting is analyzed, and a novel micro-tool is designed. A multilayer piezoelectric actuator is used to actuate a sharp needle vibrating with high frequency and low amplitude (approx. 16-50 kHz, and 0-3 microm) to cut the tissue. Contrast experiment was done to test the feasibility of UVM method. Experimental results show that the embedded tissue can be quickly and precisely cut with the ultrasonic vibration micro-dissection method.

Cell Separation↗

Feasibility study of ultrasonic fatty liver biopsy: texture vs. attenuation and backscatter.

The objective of this study was to compare textural to attenuation/backscatter indices of fatty liver correlated to histology to suggest the better approach for an objective noninvasive ultrasonic "biopsy". Forty-four patients with severe steatosis by histopathology were selected for this study. Ten patients had "pure" fatty liver and 34 had in addition fibrosis and/or inflammation. Ultrasonic images were acquired before needle insertion. The ROI used for biopsy was marked on the ultrasonic image and characterized by three attenuation/backscatter and 18 textural related indices. Statistical analysis was performed using logistic regression. Twenty-one healthy subjects served as control. The attenuation/backscatter indices were superior to textural indices in differentiating between the categories studied. Pure fatty livers could be reliably identified (AUC = 1, SE = 0). Among the 18 textural indices, "co-occurrences sum entropy" and "co-occurrences entropy" presented the best results. Attenuation/backscatter based indices appear to have better potential than the textural based indices.

Area Under Curve↗

Effects of different tissue loads on high power ultrasonic surgery scalpel.

The objective of this study is to investigate the influence of various tissue loads on the working characteristic of the ultrasonic scalpel, including working frequency, input admittance and reflection factor. Ex vivo animal experiments are carried out and relevant discussions of experimental results are provided. Admittance measurement results show that different tissue loads have different effects on a scalpel's working ability. Soft tissue makes the working frequency decrease and bone tissue makes it increase. Radius of admittance circles and reflection factor are also different. Equivalent circuit model is found and with a least-square parameter identification method, input admittance of ultrasonic scalpel with different tissue loads is solved. Results show that admittance circle radius is determined by the value of R1. Changes in L1 and C1 contribute to the shift of working frequency. This study will help decrease the sensitivity of ultrasonic scalpel to loads and greatly increase surgery efficiency.

Adipose Tissue↗