PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “VEINS, FEMORAL”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Assessment of bedside umbilical vein balloon septostomy using two-dimensional echocardiographic guidance in transposition of great arteries.

The effectiveness of "bedside" balloon atrial septostomy via the umbilical vein using 2-dimensional echocardiography was compared to the traditional femoral vein approach using fluoroscopy in a series of neonates with transposition of great arteries from March, 1984 to April, 1987. There were 7 neonates who had balloon septostomy performed at the "bedside" (Group I) compared to 13 who had the procedure performed in the catheterization laboratory (Group II). Group II consisted of 7 newborns who had elective femoral vein catheterization under fluoroscopy (Group IIA) and 6 who failed "bedside" umbilical vein balloon septostomy and subsequently had the femoral vein approach under fluoroscopy (Group IIB). Results showed that adequacy of balloon septostomy was not related to the approach used, with 4 of 7 in Group I and 9 of 13 in Group II with an adequate atrial tear and clinical response. The Delay time to septostomy (i.e. time elapsed from initial assessment to commencement of balloon septostomy) and Procedure time (i.e. time taken to complete the balloon septostomy) was significantly shorter for Group I (mean time = 0.7 hours and 0.26 hours respectively) compared with Group IIA (mean time = 2.6 hours and 1.8 hours) and Group IIB (mean time = 2.4 hours and 1.4 hours). Of note, there was no significant increase in Delay time between Group IIA and IIB.(ABSTRACT TRUNCATED AT 250 WORDS)

Catheterization↗

Ultrasound screening for deep venous thrombosis after total knee arthroplasty. 2-year reassessment.

The efficacy of ultrasound compared with ascending venography for the detection of deep venous thrombosis immediately after total knee arthroplasty was assessed after a 2-year interval. One hundred thirty-seven patients were eligible for the study; however, 31 patients received only one of the screening methods and a color Doppler examination was inconclusive in six patients. Therefore, 100 patients had a Doppler examination and a venogram. Overall, the sensitivity of ultrasound was 85%, the specificity 97%, the positive predictive value 85%, the negative predictive value 97%, and the accuracy 95%. The sensitivity in the calf was 83%, in the popliteal vein 86%, and in the femoral vein 100%. Two years ago, the initial assessment of ultrasound for the detection of deep venous thrombosis after surgery in patients who had total joint arthroplasty revealed a 75% sensitivity, 99% specificity, 91% positive predictive value, 97% negative predictive value, and 97% accuracy. The sensitivity in the calf was 83%; the sensitivity in the popliteal vein was 40%; and the sensitivity in the femoral vein was 50%. After 2 years of using this screening test with one technician and one radiologist, an improvement with this noninvasive technique was shown. However, it was found that Doppler imaging is not as sensitive as venography for detecting calf thrombi. Any imaging technique should be validated by each institution to determine the validity of the instrument and the learning curve of the technician administering the examination.

Adult↗

In vivo quantitative assessment of catheter patency in rats.

Formation of fibrin sleeves around catheter tips is a central factor in catheter failure during chronic implantation, and such tissue growth can occur despite administration of anticoagulants. We developed a novel method for monitoring catheter patency. This method recognizes the progressive nature of catheter occlusion, and tracks this process over time through measurement of changes in catheter resistance to a standardized 1 mL bolus infusion from a pressurized reservoir. Two indirect measures of catheter patency were used: (a) reservoir residual pressure and (b) reservoir discharge time. This method was applied to the study of catheter patency in rats comparing the effect of catheter material (silastic, polyurethane, Microrenathanetrade mark), lock solution (heparin, heparin/dexamethasone) and two different cannulation sites (superior vena cava via the external jugular vein, inferior vena cava via the femoral vein). Our findings reveal that application of flexible smaller-size silastic catheters and a dexamethasone lock solution resulted in prolonged catheter patency. Patency could be maintained over nine weeks with the femoral vein catheters, compared with five weeks with the external jugular vein catheters. The current method for measuring catheter patency provides a useful index for the assessment of tissue growth around the catheter tip. The method also provides an objective and quantitative way of comparing changes in catheter patency for different surgical methods and catheter types. Our method improves on the conventional method of assessing catheter occlusion by judging the ability to aspirate from the catheter.

Analysis of Variance↗

Inhibitory effect of prostaglandin E 1 on intimal thickening caused by poor runoff conditions in the canine autologous vein grafts.

The efficacy of ONO-1608, a newly developed liposomal formulation of prostaglandin E 1 prodrug, was evaluated on intimal hyperplasia of experimental canine autologous vein grafts under distal poor runoff conditions. The femoral vein was implanted into the femoral artery, preparing a distal poor runoff canine model. After 4 weeks of preparing the poor runoff model, the femoral vein was implanted into the femoral artery. They were then divided into two groups consisting of the control group and the ONO-1608 group. At 4 weeks, the grafts were harvested and intimal hyperplasia of the graft was measured with an ocular cytometer. Intimal cell proliferation was determined by bromodeoxyuridine incorporation 2 weeks after surgery. In addition, the effect of ONO-1608 on the proliferation of platelet-derived growth factor (PDGF)-stimulated human aortic smooth muscle cells (HASMCs) in culture was also investigated. At 4 weeks, the degree of intimal hyperplasia of the graft in the ONO-1608 group was significantly less than that of the control group. The bromodeoxyuridine labeling index 2 weeks after grafting was significantly lower in the ONO-1608 group compared with that in the control group. In addition, ONO-1608 significantly inhibited the proliferation of PDGF-stimulated HASMCs in culture. These results demonstrate the efficacy of ONO-1608 in reducing the degree of intimal hyperplasia of canine autogenous vein grafts under poor runoff conditions. The mechanism of reducing the intimal hyperplasia may be that ONO-1608 inhibited PDGF-stimulated proliferation of the smooth muscle cell. These results suggest that the administration of ONO-1608 may be beneficial in patients who have undergone gone arterial reconstruction.

Alprostadil↗

Efficacy of low-dose heparin in prevention of extensive deep-vein thrombosis in patients undergoing total-hip replacement.

In a prospective trial, the prophylactic efficacy of low-dose heparin was investigated in 84 consecutive patients undergoing total-hip replacement. 52 of these were randomly allocated to receive heparin or a combination of heparin and dihydroergotamine (D.H.E.); the remaining 32 patients, who were operated on by one orthopaedic team and did not receive prophylaxis, acted as a control group. The frequency of deep-vein thrombosis (D.V.T.), determined by the 125I-fibrinogen test and venography, was 69% in the control group, 32% in the patients receiving heparin alone, and 16% in those receiving heparin and D.H.E. The difference between the control group and each group receiving prophylaxis was statistically significant. The frequency of femoral-vein thrombi, demonstrated by venography, was analysed separately because of its frequent association with major pulmonary embolism. Femoral-vein thrombi developed in 17 (53%) in the control group, while they developed in only 4 patients (8%) in the prophylaxis group (P less than 0.01). 1 patient in the control group died due to massive pulmonary embolism; in another patient, again in the control group, clinical features suggestive of major non-fatal pulmonary embolism developed. This complication was not observed in patients receiving prophylaxis. There was no difference in the amount of operative or postoperative blood-loss in the three groups. In 3 patients in the entire series wound haematomata developed; all 3 were controls and haematomata developed after the administration of streptokinase or large doses of heparin for the treatment of extensive femoral-vein thrombi. By use of a sensitive assay, heparin could be detected in the plasma in 67% of samples in patients in whom D.V.T. did not develop. In contrast, in those patients in whom D.V.T. developed, heparin could be detected in only 21% of blood-samples (P less than 0.01). It is concluded that in patients undergoing total-hip replacement, low-dose heparin prophylaxis is effective in reducing the frequency of life-threatening extensive thrombi in the femoral vein. Prophylaxis using a combination of heparin and D.H.E. requires further evaluation.

Clinical Trials as Topic↗

Diffusion-limited tissue equilibration and arteriovenous diffusion shunt describe skeletal muscle nitrous oxide kinetics at high and low blood flows in sheep.

This study evaluated the relative importance of perfusion and diffusion mechanisms in compartmental models of blood : tissue inert gas exchange in skeletal muscle. Nitrous oxide kinetics in a hind limb skeletal muscle bed were determined during and after 20 min of nitrous oxide inhalation, at separate low and high steady states of hind limb blood flow in five sheep under halothane anaesthesia. Nitrous oxide concentrations in arterial and femoral vein blood were determined using gas chromatographic analysis and femoral vein blood flow was monitored continuously. Parameters and model selection criteria of various perfusion- or diffusion-limited structural models of skeletal muscle were estimated by simultaneous fitting of the models to the mean observed femoral vein nitrous oxide concentration for both blood flow states. Purely perfusion-limited models fit the data poorly. Models that allowed a diffusion-limited exchange of nitrous oxide between a perfusion-limited tissue compartment and an unperfused deep compartment provided better overall fit of the data and credible parameter estimates. The data was best described by allowing, in addition to diffusion-limited tissue equilibration, counter current diffusion of nitrous oxide between arterial and venous blood. The level of tissue blood flow modifies the magnitudes of both these diffusion effects. These results suggest a dual role of diffusion in blood : tissue inert gas equilibration in skeletal muscle.

Algorithms↗

The influence of collection site and methods on postmortem morphine concentrations in a porcine model.

This study was to determine the relationship of antemortem to postmortem morphine concentrations in heart and femoral blood in a porcine model following acute intravenous opiate overdose. The study involved 20 swine; each was sacrificed 10 min after injection of 2 mg/kg body weight of morphine. Drug concentrations were assayed from vitreous humor and blood isolated from the femoral vein and artery and left and right ventricles at various times postmortem. Comparisons were made between antemortem and postmortem values to determine agreement and reliability. Both free and total postmortem values varied significantly among animals, sampling sites, and over time. Free postmortem values were generally higher in comparison with antemortem values, whereas postmortem total morphine values were similar to or slightly lower than antemortem values. The effect of time on postmortem values was small. These results demonstrate a significant amount of variability in free and total morphine measurements both over time and within and between sites. Furthermore, a comparison of antemortem to postmortem values demonstrates a lack of consistency relative to the dose of morphine administered. Concentrations of morphine in the femoral vein were typically the lowest observed. This observation is not surprising given the transformation that occurs prior to the drug reaching the femoral vein. Values associated with diffuse tissues, relative to femoral veins, demonstrate more stochastic variation.

Analgesics, Opioid↗

Xanthine oxidase in critically ischaemic and claudicant limbs: profile of activity during early reperfusion.

Xanthine oxidase activity in blood from the ipsilateral femoral vein, and the relationship between xanthine oxidase production and the products of lipid peroxidation, were studied before operation and for 60 min following release of clamps after successful revascularization in two groups of patients with claudication or critical ischaemia. Before revascularization, detectable levels of xanthine oxidase were found only in patients with critical ischaemia. Clamping during bypass surgery led to release of xanthine oxidase in claudicants, but this activity reduced after 60 min. There was no evidence of lipid peroxidation during this time. Xanthine oxidase activity in brachial vein blood was higher than in femoral vein blood in patients with critical ischaemia before revascularization.

Adult↗

Venous hemodynamic changes during laparoscopic cholecystectomy.

Virchow's triad of venous stasis, vessel wall damage, and hypercoagulability cites three factors that predispose to the formation of venous thrombosis. The pneumoperitoneum created during laparoscopic surgery results in an intraabdominal pressure that exceeds the pressure of venous blood return from the legs. This may alter venous hemodynamics enough to result in venous stasis in the legs, thus increasing the risk of thrombus formation. Duplex ultrasound was used to measure the diameter and venous flow volume of the common femoral vein during laparoscopic cholecystectomy. Measurements were obtained at three different times: after induction of anesthesia but prior to creation of pneumoperitoneum, during pneumoperitoneum, and after abdominal deflation but prior to reversal of anesthesia. After insufflation of the abdomen, the mean cross-sectional area of the common femoral vein increased (0.83 to 1.15 cm2; p = 0.0024) and the venous flow decreased (11.00 to 6.06 cm3/sec; p = 0.0008). After deflation of the abdomen, there was no significant change in cross-sectional area of the common femoral vein, but there was an increase in venous flow (6.06 to 9.94 cm3/sec; p = 0.0005). Abdominal insufflation during laparoscopic cholecystectomy results in dilation of and decreased flow in the common femoral vein. After deflation of the abdomen, flow in the vein returns to baseline levels.

Adult↗

Superficial femoral-popliteal vein as a conduit for brachiocephalic arterial reconstructions.

Revascularization of brachiocephalic arteries with prosthetic graft offers excellent patency for most reconstructions. For complex brachiocephalic reconstructions, such as redo operations or reconstructions for infection, autogenous conduit may be preferable. Occasionally saphenous vein is inadequate or absent. The purpose of this study was to evaluate the indications and intermediate-term outcomes of superficial femoral-popliteal vein (SFPV) as an alternative conduit for brachiocephalic reconstructions. Over a 6-year period, 71 patients underwent carotid, subclavian, or axillary artery bypass. In 18 (25%) of these reconstruction SFPV was used as the conduit. Ten bypasses (55%) were redo operations. Three bypasses (17%) were performed after failed prosthetic grafts. Three grafts (17%) were required in infected patients. Indications for the use of SFPV included inadequate saphenous vein (n = 13), infection (n = 3), and failed prosthetic bypass (n = 3). Thirty-day mortality was 5.5%. The neurologic event rate was 5.5%. During a mean follow-up of 26 +/- 5 months, there were no graft thromboses or graft infections. Revision-free primary patency was 92% at 48 months. Assisted primary patency was 100%. These data suggest that SFPV is a safe, durable conduit for brachiocephalic reconstructions. SFPV yielded excellent results for a disadvantaged patient population.

Adult↗

[Aneurysm of the femoral and popliteal vein].

Aneurysms of the popliteal and femoral veins are rare and may be seen as casual findings with no clinical manifestations whatsoever. On the other hand they may be potential source of recurrent pulmonary embolism. A case is reported, where an aneurysm of the femoral vein was found in a clinically symptomless woman aged 48.

Aneurysm↗

Critical capillary oxygen partial pressure and lactate threshold in patients with cardiovascular disease.

OBJECTIVES: The aim of this study was to determine the relation between femoral vein oxygen partial pressure (PO2) and lactate increase during exercise in patients with cardiovascular disease. BACKGROUND: Considerable controversy surrounds the relation between the increase in lactate during exercise and the oxygen supply to the exercising muscles. We assumed that femoral vein PO2 would be a measure of end-capillary PO2 during leg-cycling exercise and that it would decrease to a "floor" level when the critical capillary PO2 (the PO2 below which the capillary-mitochondrial difference would be too low to allow oxygen consumption) was reached. At the critical capillary PO2, anaerobic metabolism should take place, and lactate should increase in the effluent blood. METHODS: Ten patients with cardiovascular disease performed two 6-min constant work rate tests (moderate and heavy intensity) and an incremental exercise test to the symptom-limited maximum on a cycle ergometer. Femoral vein blood was repeatedly sampled through a percutaneous catheter before and during each exercise test. RESULTS: The PO2 rapidly decreased toward a minimal value with increasing oxygen uptake for all three tests in all patients. After reaching its nadir (18.2 +/- 2.0 mm Hg), the PO2 remained unchanged in five patients but increased in the other five patients despite the further increase in work rate and oxygen uptake. The relation between PO2 and oxygen uptake was characteristic for each patient and independent of the protocol used for the study. Femoral vein lactate did not change appreciably until PO2 reached the minimal (critical) value. Thereafter, it dramatically increased without a further decrease in PO2. The minimal PO2 was positively correlated with the peak oxygen uptake (r = 0.70, p = 0.01). CONCLUSIONS: During leg-cycling exercise, muscle capillary PO2 reaches a minimal value in the midrange of the subjects' work capacity before lactate concentration increases in patients with cardiovascular disease. The lack of further decrease in PO2 at the oxygen uptake at which lactate starts to increase suggests that the minimal capillary PO2 is the "critical" capillary PO2.

Aged↗

Magnetic resonance venography to evaluate the deep venous system of the pelvis in patients who have an acetabular fracture.

We performed a prospective, blinded study to assess and compare the values of preoperative contrast venography and magnetic resonance venography in the detection of deep venous thrombosis in the thigh and pelvis of forty-five consecutive patients who had a displaced acetabular fracture. The magnetic resonance venography and contrast venography were performed an average of seven days (range, one to twenty-nine days) after the injury. Twenty-four asymptomatic thrombi were identified with magnetic resonance venography in fifteen (33 percent) of the patients. Four of the thrombi were in the superficial femoral vein, nine were in the common femoral vein, one was in the external iliac vein, seven were in the internal iliac vein, and three were in the common iliac vein. Ten (42 percent) of the twenty-four thrombi were confirmed with contrast venography; nine of them were located in the thigh. The remaining fourteen thrombi (58 percent) that had been noted on magnetic resonance venography could not be seen with contrast venography because they were located either in the deep pelvic veins or in the uninjured extremity. The thrombi in the internal iliac vein were identified only with magnetic resonance venography. Twelve of the fifteen patients who had thrombi had a filter placed in the inferior vena cava preoperatively. In eight of these patients, the filter was placed because of the findings of magnetic resonance venography alone. Magnetic resonance venography resulted in a change in the therapeutic management of ten (22 per cent) of the forty-five patients. There were no pulmonary emboli. We concluded that magnetic resonance venography is superior to contrast venography for the preoperative evaluation of proximal deep venous thrombosis in patients who have an acetabular fracture. Magnetic resonance venography is non-invasive, does not require the use of contrast medium, images the proximal aspects of both lower extremities simultaneously, and, most importantly, allows for the identification of deep venous thrombosis in the pelvis.

Acetabulum↗

Venous valvular insufficiency: influence of a single venous valve (native and experimental).

This report evaluates the ability of a single competent (native or experimental) superficial femoral vein valve to correct canine hindlimb venous insufficiency. The time to maximal ankle venous pressure after standing (VFT) and to 90% of that time after exercise (VRT90), and the minimal pressure after exercise (AVP) were measured in 17 greyhounds before intervention, after only the superficial femoral vein valve remained (n = 5), and after complete lower limb venous valvulotomy (n = 17). Three weeks later, 12 dogs underwent a native (n = 4) or experimental (n = 8) autogenous venous valve transplantation. Immediately and at 3 weeks after transplantation, venous pressure measurements were obtained. The manual strip test confirmed valve competence at the time of sacrifice. Only one valve transplant became incompetent. Immediately after single superficial femoral vein valve construction, VFT, AVP, and VRT90 measurements were not significantly different from normal. Three weeks after transplantation the AVP measurements were consistent with an insufficient venous system, whereas the VRT90 measurements were between and statistically different from both the control and totally incompetent system (p less than 0.05). After the native valve but not the experimental valve transplantations VFT normalized. These data suggest that insertion of a single competent superficial femoral vein valve into an incompetent lower limb venous system corrects venous pressure measurements initially but soon provides only a partially competent system. The experimental valve, although competent, is less responsive than a native valve.

Animals↗

[Endovascular treatment of sinus dural fistulas using vein catheterism].

PURPOSE: We report two techniques for treatment of dural arteriovenous fistulas using femoral vein catheterism and direct surgery via the superior ophthalmic vein. We will attempt to show the advantages of these new techniques instead of using the arterial pathway, which is currently the reference procedure. SUBJECTS AND METHOD: Mrs G, 75 years old was sent by her ophthalmologist because of a suspected orbital tumor. Visual acuity: right eye: 3/10, exophthalmia, chemosis, with no thrill or murmur. The fundus examination was normal. The ultrasound exam with color Doppler imaging showed an arterialization of the superior ophthalmic vein compatible with an arteriovenous sinus dural fistula. Angio-MRI revealed a large left cavernous sinus, confirming the diagnosis. Considering the type of the fistula and the weak physical condition of the patient, we decided to attempt an endovascular embolization with coil placement, using femoral vein catheterism. Exophthalmia regressed within days. The fistula remains sealed 1 year after the procedure. Mr D, 40 years old, showed a similar clinical aspect of sinus dural fistula. We attempted an embolization with the femoral vein, which failed. We decided to embolize the cavernous sinus via the direct surgical pathway of the superior ophthalmic vein. Coils were placed and the fistula was sealed. CONCLUSION: These clinical cases show two less invasive alternatives giving better results than arterial embolization, the reference method (Brooks 1930; Spearmann 1964; Parkinson 1965), endovascular trapping, or surgery.

Adult↗

[Femoral arterio-venous fistula. A rare complication of right heart catheterization].

Percutaneous central venous catheterization through the femoral vein is frequently used in the Coronary Care Unit. Complications such as thrombophlebitis, thromboembolism and femoral artery puncture are rare. We describe a case of arteriovenous fistula due to femoral vein catheterization in a 61 year old man who was admitted because of advanced atrioventricular block. Auscultation revealed a systodiastolic murmur. Two dimensional and color Doppler flow imaging demonstrated an arteriovenous communication between the superficial femoral artery and common femoral vein without hemodinamic consequences. Two months later, on physical examination and Doppler investigation, the fistula had disappeared.

Arteriovenous Fistula↗

[Stent implantation for iliac compression syndrome with acute deep vein thrombosis: a case report].

An 80-year-old woman presented with left lower limb pain and swelling with tenderness over the great saphenous vein. Venography revealed thrombus in the lower leg vein and occlusion of the femoral vein. A temporary vein filter was placed below the renal vein and catheter intervention was performed. The wire was carefully advanced from the left femoral vein to the vena cava. Hard resistance was felt at the proximal iliac vein. After balloon dilation, intravascular ultrasonography showed a very flat lumen at the occlusion site. Stent implantation was performed followed by anticoagulation therapy. Venography at 3 months follow-up showed a widely opened iliac vein. Angiography showed the occlusion site was the crossing point of the right iliac artery and left iliac vein. Stenting for iliac compression syndrome is effective to maintain patency of the vein.

Aged↗

Modulation of contractions to and receptors for endothelins in canine veins.

Experiments were designed to characterize endothelin receptors in canine femoral veins and to determine whether their distribution or sensitivity could be altered by chronic changes in blood flow and oxygen tension in veins proximal to an arteriovenous fistula. Endothelium was removed from unoperated or fistula-operated femoral veins of anesthetized dogs. Veins were cut into rings and suspended in organ chambers for the measurement of isometric force or frozen for isolation of membrane proteins. Endothelin-1, endothelin-3, and sarafotoxin S6c caused concentration-dependent increases in tension in all rings. In rings of unoperated veins, maximal tensions were significantly less to endothelin-3 and sarafotoxin S6c than to endothelin-1. In rings of fistula-operated veins, maximal tensions to endothelin-1 and endothelin-3 were the same. Contractions to endothelin-1 or endothelin-3 in unoperated veins were not inhibited by an antagonist of endothelin-A receptors, BQ-123. Binding of 125I-labeled endothelin-1 (125I-endothelin-1) to membranes from veins without endothelium increased as a function of membrane protein. Affinity of receptors, as determined by competitive inhibition of 125I-endothelin-1 was as follows: endothelin-1 > endothelin-3 > sarafotoxin S6c. Competitive inhibition of 125I-endothelin-1 by endothelin-3 and sarafotoxin S6c was significant for a two-site binding model in all veins. The total number of binding sites was reduced significantly in fistula-operated veins; the relative proportions of high- and low-affinity binding sites did not change. Affinity of high- and low-affinity receptors increased in fistula-operated veins.(ABSTRACT TRUNCATED AT 250 WORDS)

Acetylcholine↗