Atrial electrical remodeling by rapid pacing in the isolated rabbit heart: effects of Ca++ and K+ channel blockade.

INTRODUCTION: Electrical remodeling describes atrial electrophysiologic changes that occur following atrial fibrillation. The mechanism(s) responsible for this phenomenon is not well understood. The purpose of this study was to examine the effects of rapid atrial pacing on atrial action potential duration, conduction time and refractoriness in the isolated rabbit heart. The effects of Ca++ and K+ blockade in this model were also studied. METHODS AND RESULTS: Monophasic action potential recordings were made from 12 epicardial atrial sites in 50 isolated perfused rabbit heart preparations. These recordings were analyzed for activation time (AT), 90% action potential duration (APD) and conduction times (CT) measured at a 250 msec cycle length. Atrial effective refractory periods (ERP) were determined at a 200 msec cycle length. All measurements were made at baseline and repeated after 2 hours of biatrial pacing at 250 msec (control group, n = 10) or 2 hours of rapid biatrial pacing (approximately 80 msec) in 4 groups: rapid pacing alone (rapid pacing group); rapid pacing in the presence of 0.1 mM verapamil (verapamil group) for L-type Ca++ channel blockade; rapid pacing with 1 mM 4-aminopyridine (4-AP group) for K+ channel blockade; and rapid pacing with 50 microM nickel chloride (Ni++ group) for T-type Ca++ channel blockade (n = 10 each group). All baseline and post pacing measurements were taken in the presence of Ca++ or K+ blockers for the respective groups. After rapid atrial pacing alone the average APD shortened by 8.2 +/- 10.4 msec compared to 3.6 +/- 12.5 msec shortening for control group (p = 0.002). The shortening of APD was uniform at all recording sites. For the rapid pacing group, CT was unchanged for right to left atrial conduction but shortened significantly for left to right atrial conduction (26.8 +/- 1.9 msec at baseline to 22.3 +/- 4.1 msec post pacing, p = 0.005). Conduction times were unchanged in the control group. The dispersion of repolarization was unchanged by rapid pacing alone. The decrease in APD from baseline to post rapid pacing was similar to the control group for those hearts treated with verapamil and 4-AP (1.5 +/- 12.3 and 4.7 +/- 10.4 msec, respectively, both p > or = 0.18 vs control group). The decrease in APD was significantly greater for the Ni++ group (11.8 +/- 14.3 msec) than for either the control group or rapid pacing group (both p < or = 0.023). The dispersion of repolarization was increased only in the 4-AP group post rapid pacing (41.7 +/- 6.2 msec at baseline to 53.5 +/- 9.6 msec post pacing, p = 0.01). ERPs were unchanged in any of the 5 groups except for a decrease in left atrial ERP in the Ni++ group after rapid pacing (98 +/- 14 msec at baseline to 88 +/- 8 msec post rapid pacing, p = 0.005). CONCLUSIONS: In the isolated rabbit heart model: 1) atrial APD is shortened after rapid pacing; 2) the shortening of APD is attenuated by verapamil and 4-AP but exaggerated by Ni++; 3) atrial conduction times are shortened in a direction specific manner after rapid pacing; and 4) shortening of ERP in this model is measured only in the presence of Ni++. These findings suggest that both L-type Ca++ and 4-AP sensitive channels may participate in atrial electrical remodeling.

4-Aminopyridine↗

Congenitally complete heart block. Developmental aspects.

Three cases of congenitally complete heart block are described of hearts in which other minor congenital malformations were not in themselves severe enough to disrupt the atrioventricular conduction system. The cases fitted well into the categorization of complete heart block suggested by Lev. Two exhibited lack of communication between the atrial and conducting tissues, the other had discontinuity of the penetrating atrioventricular bundle. In an attempt to explain why this discontinuity between different segments of the conducting tissues occurs, we re-examined several series of graded human embryos. This investigation suggested that the anulus fibrosus in the normal heart is derived from sulcus tissue of the atrioventricular junction, the endocardial atrioventricular cushions playing a minor role in the separation of atria from ventricles. The relationships between the sulcus tissues and the different components of the atrioventricular junctional area are discussed in terms of an explanation both for the existence of different types of congenitally complete heart block and for persistence of Mahaim (nodo-ventricular and nodo-fascicular) fibers.

Abnormalities, Multiple↗

Dose-related cardiac electrophysiological effects of intravenous magnesium. A double-blind placebo-controlled dose-response study in patients with paroxysmal supraventricular tachycardia.

AIMS: The role of magnesium as an antiarrhythmic drug is yet not conclusive. Therefore, we performed a double-blind, randomized, placebo-controlled dose-response study of cardiac electrophysiological effects of intravenous magnesium. METHODS AND RESULTS: Thirty-six patients undergoing an electrophysiological evaluation for paroxysmal supraventricular tachycardia were randomized to one of the following dosages of intravenous magnesium (0, 5, 10 or 20 mmol). Conventional electrophysiological variables for sinus node function, atrial, atrioventricular node and ventricular conduction and refractoriness were measured before and after magnesium administration. Prolongation of the atrial-His interval was found at 5 mmol of magnesium compared with placebo and no further prolongation was observed at higher doses (-3 +/- 8, 11 +/- 9, 7 +/- 15, 11 +/- 16, for the dosages of 0, 5, 10 and 20 mmol of magnesium, respectively, P < 0.05). Measures of sinus node function, intra-atrial conduction and conduction through the Purkinje system were unaffected by magnesium. Male gender was associated with prolongation in atrial effective refractory period, in contrast to shortening in females: 2 +/- 43, 35 +/- 44, 36 +/- 33, 13 +/- 12 ms for males and 3 +/- 6, -12 +/- 11, -13 +/- 12, 0 +/- 23 ms for females, respectively (P < 0.001). CONCLUSION: Atrioventricular node conduction was prolonged by 5 mmol intravenous magnesium and no further prolongation was observed at higher dosages. At dosages of 5 and 10 mmol magnesium the atrial effective refractoriness was prolonged in males and shortened in females.

Adolescent↗

The use of implantable sensors for the control of pacemaker mediated tachycardias: a comparative evaluation between minute ventilation sensing and acceleration sensing dual chamber rate adaptive pacemakers.

The role of implantable sensors to control pacemaker mediated tachycardias was investigated in 16 patients with two different dual chamber rate adaptive (DDDR) pacemakers, which sensed eiter minute ventilation (DDDR-Meta, nine patients) or body acceleration (Relay, seven patients). Successive atrial sensed events beyond a programmable rate occurring in the absence of detection of exercise by the sensors were considered to represent retrograde conduction or atrial arrhythmias, and the pacemakers responded by either a mode shift from DDDR to ventricular rate adaptive (VVIR) pacing (DDDR-Meta) or by tracking at an interim rate, the so-called conditional ventricular tracking limit (CVTL, Relay). In the unipolar atrial sensing mode, myopotential sensing (MPI) and external chest wall stimulations (CWS) at 250 beats/min were induced to be preferentially sensed by the atrial channel to simulate the conditions of atrial arrhythmias. In the DDD mode, these maneuvers resulted in ventricular responses of 88 +/- 3 beats/min and 110 +/- 3 beats/min for MPI and CWS, respectively. The pacing rate was significantly reduced in the DDDR mode with the sensors correctly detecting and responding to the sensed abnormal atrial signals (68 +/- 5 beats/min during MPI and 71 +/- 5 beats/min during CWS, P less than 0.005 compared with the corresponding DDD rate). One patient with a Relay pacemaker developed spontaneous atrial flutter and the ventricular tracking responses were 140 and 85 beats/min in the DDD and DDDR pacing modes, respectively. Thus MPI and CWS are useful bedside testing methods to assess pacemaker response during atrial arrhythmias. The use of implantable sensors to judge the appropriateness of atrial rate is a new approach to the management of pacemaker mediated tachycardias.

Adult↗

Uneven distribution of injuries in calcium paradox, postischemic reperfusion and by reactive oxygen species damaged heart. Histochemical and ultrastructural studies.

Under physiological conditions different parts of the heart reveal superspecialization of the myocardium reflected by biochemical, functional, structural and histochemical differences, which are even more pronounced under pathological conditions. Postischemic reperfusion, Ca paradox and injury caused by reactive oxygen species were found to result in transmurally unhomogenous damage of the ventricular wall. In the present experiments isolated perfused rat hearts were subjected to damage by the above mechanism and a different vulnerability of defined parts of the heart was observed. Activities of glycogen phosphorylase, SDH, beta-HBDH, and LDH were studied histochemically in both ventricles, the atria and the specialized conductive system of the heart. Marked decreases of activities were observed in the ventricular muscle. The enzyme activities were less decreased in the atrial muscle. Conductive fibres were the least affected tissue in this respect. The differential changes were most sensitively reflected by glycogen phosphorylase. The differences in transmural distribution of damage were shown to be dependent on a complex of specific factors such as intramural pressure gradient, transmural pressure, end-diastolic intraventricular pressure, differences in transmural vessel distribution, transmural hematocrit differences, blood flow, perfusate volume, and endothelial injuries of different origin. It can be concluded that differences in ultrastructure as well as in enzyme activities in different parts of the heart reflect functional, structural and metabolic heterogeneity of the different functional parts of the heart muscle.

Animals↗

Electroanatomic mapping to identify breakthrough sites in recurrent typical human flutter.

The accuracy of conventional techniques in localizing previous radiofrequency (RF) ablation sites and thus breakthrough sites of recurrent atrial flutter is somewhat limited. We investigated the role of electroanatomic mapping for identifying breakthrough sites or "gaps" at the tricuspid annulus and inferior vena cava (IVC)/eustachian ridge isthmus to help RF ablation in patients with recurrent typical flutter. Twelve patients (8 men, 4 women, age 63 +/- 10 years) with recurrent typical atrial flutter were included in the study. An electroanatomic mapping system (CARTO) was used to create a voltage map and activation and propagation patterns in the right atrium. Detailed voltage, activation, and propagation mapping of the tricuspid annulus and IVC/eustachian ridge isthmus allowed precise identification of gaps in all 12 patients at the tricuspid annulus (eight sites), IVC ridges (two sites), mid-isthmus region (one site), and tricuspid annulus and IVC ridges (one site). Radiofrequency energy directed at these sites eliminated atrial flutter in all 12 patients, confirmed by noninducibility of atrial flutter and demonstration of conduction block during atrial pacing on either side of the lesion lines. During a mean follow-up of 14.8 +/- 3.5 months (range 8-19 months), paroxysmal atrial flutter recurred in only one patient and was subsequently treated with amiodarone, although this had been ineffective prior to ablation. Electroanatomic mapping can precisely identify gaps in the lesion line responsible for breakthrough of recurrent typical atrial flutter at the tricuspid annulus and at the IVC/eustachian ridge isthmus. These sites can be targeted with RF ablation with a high degree of success.

Atrial Flutter↗

Enhancement of coronary conductance by alpha-human atrial natriuretic polypeptide without effects on myocardial contractility.

The effect of synthetic human atrial 28-amino acid peptide (alpha-human atrial natriuretic polypeptide, alpha-hANP) on coronary circulation and cardiac functions was examined in open-chest dogs. Intravenous injection of alpha-hANP increased coronary and systemic conductance, and coronary and aortic blood flow with a significant fall in blood pressure. Continuous infusion of alpha-hANP into the left anterior descending coronary artery (LAD) increased LAD blood flow in a dose-dependent manner. The linear regression analysis revealed the relationship of logit (changes in mean coronary conductance (delta MCC] = 1.45 x log (coronary plasma concentration of alpha-hANP) + 7.51 (r = 0.87, n = 29). REC50 of alpha-hANP was 5.1 microM, where REC50 was the concentration to increase MCC to a half maximum MCC during reactive hyperemia after a 30-s coronary occlusion. alpha-hANP increased coronary conductance with no changes of myocardial oxygen consumption (MVO2) when blood pressure remained constant. Indices of myocardial contractility measured with a strain gauge arch, myocardial force (F), max dF/dt and LV max dp/dt, were not altered by either bolus intravenous injection or continuous intracoronary infusion of alpha-hANP. These results indicated a direct increase by alpha-hANP of coronary and systemic vascular conductance.

Animals↗

Localisation of atrial natriuretic peptide immunoreactivity in the ventricular myocardium and conduction system of the human fetal and adult heart.

Atrial natriuretic peptide immunoreactivity was found in ventricular and atrial tissues with specific antisera raised to the amino and carboxy terminal regions of the precursor molecule. In 13 developing human hearts (7-24 weeks' gestation) the immunoreactivity was concentrated in the atrial myocardium and ventricular conduction system but it was also detected in the early fetal ventricular myocardium. Immunoreactivity in five normal adults was largely confined to the atrial myocardium although it was also found in the ventricular conduction tissues of hearts removed from 10 patients who were undergoing cardiac transplantation. The ventricular conduction system is an extra-atrial site for the synthesis of atrial natriuretic peptide. In the failing heart this synthesis may be further supplemented by expression of the gene in the ventricular myocardium. It is possible that ventricular production of the peptide contributes to the raised circulating concentrations of atrial natriuretic peptide immunoreactivity found in severe congestive heart disease, particularly in patients with dilated cardiomyopathy.

Adolescent↗

Atrial pacing in the management of sick sinus syndrome: long-term observation for conduction disturbances and supraventricular tachyarrhythmias.

Atrial pacing (AAI) in sick sinus syndrome (SSS) has been questioned because of the risk of distal conduction disturbances (DCD) and atrial tachyarrhythmias. The authors studied the incidence of clinically relevant DCD and arrhythmias in 52 SSS patients with AAI. The observation time was 25-67 (mean 48) months. Invasive electrophysiologic investigation was performed preoperatively in 29 cases and preoperative atrial pacing to Wenckebach block or to 150 ppm in 23. The preoperative investigation showed prolonged HV-time in three cases and Wenckebach block at 110 ppm in one case, while six patients had LAH-block, five RBB-block and two first degree AV-block. No further DCD developed in any of these patients. Second-degree type I AV-block developed in two patients after 2 and 19 months, respectively. One had been treated with digitalis and verapamil and was asymptomatic. The other patient, who had a low ventricular rate, experienced near-syncope. These two blocks could not be predicted from the preoperative and peroperative investigations. In five patients (10%) permanent atrial fibrillation developed during the follow-up period. The incidence of concomitant supraventricular tachyarrhythmias in the patients with the bradycardia-tachycardia syndrome appeared to be unaffected by the pacemaker treatment.

Adult↗

A new algorithm to determine complete isthmus conduction block after radiofrequency catheter ablation for typical atrial flutter.

The induction of a complete conduction block of the isthmus between inferior vena cava and tricuspid annulus is considered the best predictor for lack of arrhythmia recurrence if radiofrequency catheter ablation for typical atrial flutter is performed. We evaluated a simplified algorithm to determine complete isthmus block that, in our series, had a predictive accuracy of 100% when compared with the gold standard.

Algorithms↗

Impaired longitudinal conduction in crista terminalis is necessary for sustenance of experimental atrial flutter.

Sustained atrial flutter (AFL) can be induced by creating a lesion between the vena cava in dogs. In previous studies on this model, the crista terminalis (CT) was often injured, and thus, role of CT in sustained reentry was not well understood. We hypothesized that impaired longitudinal conduction in CT is necessary for sustained AFL. In 16 anesthetized, open-chest dogs, linear radiofrequency ablation of the intercaval region was performed without interrupting CT. Intra-atrial conduction times (IAT) along CT were measured using a plaque electrode (25x35 mm) containing 30 bipolar electrodes before and after additional ablation of CT (group A, n=10) or the pectinate muscle (PM) region (group B, n=6). In group A, IAT along CT was 27 +/- 5 ms at baseline and was increased to 43 +/- 3 ms after ablation of CT (P<0.001). In group B, IAT along CT was 28 +/- 4 ms at baseline and 27 +/- 3 ms after ablation of PM (P=NS). Sustained AFL lasting >20 minutes was induced in 10/10 dogs in group A only after additional ablation of CT, and in 0/6 dogs in group B (P<0.001). The cycle lengths of AFL after ablation of the intercaval region and additional ablation of CT were 119 +/- 14 and 140 +/- 14 ms, respectively (P<0.01). There was a significant positive correlation between the cycle length of AFL and IAT along CT (r2=0.63, P<0.001). These results indicate that longitudinal conduction property in CT and not in PM strongly affects sustenance of AFL in this model.

Analysis of Variance↗

Radiofrequency catheter modification of atrioventricular conduction to control the ventricular rate during atrial fibrillation.

BACKGROUND: In some patients with atrial fibrillation, the ventricular rate may be difficult to control with medications. We evaluated a radiofrequency catheter technique to modify atrioventricular conduction in atrial fibrillation in order to control the ventricular rate without creating pathologic atrioventricular block. METHODS: We studied 19 consecutive patients with atrial fibrillation and uncontrolled ventricular rates refractory to drug therapy. They had had atrial fibrillation for a mean (+/- SD) of 5.5 +/- 4.9 years, had had 4.9 +/- 0.9 unsuccessful drug trials, and were 62 +/- 15 years old. Before the procedure, the maximal ventricular rate during exercise was 180 +/- 39 beats per minute. A total of 11 +/- 5 radiofrequency-energy applications were delivered to the posterior septal or midseptal right atrium, near the ostium of the coronary sinus. RESULTS: Successful control of the ventricular rate without pathologic atrioventricular block was achieved in 14 of the 19 patients (74 percent). Persistent third-degree atrioventricular block requiring a permanent pacemaker occurred inadvertently in four patients (21 percent). Atrioventricular conduction was intentionally ablated in one patient. The 14 patients who had successful modification of conduction had persistent reductions in maximal ventricular rate during exercise (rate at three months, 126 +/- 24 beats per minute; P < 0.01). These patients had resolution of symptoms related to rapid rates during 8 +/- 2 months of follow-up. One patient had a recurrence of a rapid ventricular rate but was again asymptomatic after a second modification procedure. One patient with dilated cardiomyopathy died suddenly, five months after a successful procedure. CONCLUSIONS: A catheter technique to modify atrioventricular conduction without creating pathologic atrioventricular block is feasible in the majority of patients with symptomatic atrial fibrillation and a rapid ventricular rate refractory to drug therapy.

Adult↗

Clinical observations with long-term atrial pacing.

Atrial pacing (AP), despite its beneficial hemodynamic and antiarrhythmic effect, is still an underused mode of stimulation. The main purpose of this study was to evaluate the long-term results of AP. Sixty four patients (pts) with sinus node disease (28 male and 36 female: mean age 54.2; range: 44-88 years), 3.2% of the total implantation at our clinic were treated with AP between 1982-96. Criteria for atrial pacing were: no AV block in the history, no AV-block during carotid sinus massage, Wenckebach point > 130/min, left atrium < 50 mm, left ventricular EF > 40%. The indication for pacing was predominant sinus bradycardia (SB) in 34 pts and tachycardia-bradycardia syndrome (TBS) in 30 pts. Pts with TBS were on antiarrhythmic treatment, while most pts with SB received no antiarrhythmic drugs. All the pts were checked up at every 3-6 month. Sixty-two pts were followed for 3-154 (mean: 67) months, two pts were lost for follow-up. Repeated lead dislodgment occurred in two pts, which made a pacing mode change necessary. Four pts died during the follow-up period for non-cardiac reasons. At the end of the follow-up period the data of 60 pts were available for evaluation (33 pts with SB, 27 pts with TBS). All the pts with SB were in sinus rhythm, and no patient developed AV block by the end of the follow-up period. Seven out of 27 pts with TBS developed chronic atrial fibrillation, 3 out of them suffered a cerebral embolism; the remaining 20 pts were in sinus rhythm, and the number of paroxysmal attacks decreased significantly, which improved their quality of life significantly. Three pts in this group developed a temporary complete AV block, which regressed with decreasing the dosage of antiarrhythmic drugs. Atrial pacing is proved to be a safe and reliable treatment for sick sinus syndrome. Proper patient selection is crucial in preventing the development of AV conduction disturbance. Atrial stimulation had a satisfactory long-term antiarrhythmic effect in pts with sick sinus syndrome (SSS).

Anti-Arrhythmia Agents↗

Different patterns of interatrial conduction in clockwise and counterclockwise atrial flutter.

BACKGROUND: The terms counterclockwise (CC) and clockwise (C) atrial flutter (Afl) are used to describe right atrial activation around the tricuspid valve in the left anterior oblique view. The manner in which the left atrium is activated, as reflected by coronary sinus (CS) recordings, has not been systematically evaluated. METHODS AND RESULTS: Nine patients with both CC and C Afl underwent electrophysiological study with CS recordings during both rhythms with the use of a decapolar catheter with the tip placed in the distal CS. Patterns of CS activation during each type of Afl as well as during during sinus rhythm were categorized into 1 of 3 patterns: sequential proximal-to-distal, sequential distal-to-proximal, and fused, indicating activation from different directions. In 7 of 9 patients, the pattern of CS activation in CC Afl and C Afl differed, with a proximal-to-distal pattern in CC Afl and a fused pattern in C Afl. In 2 patients, pacing the high right atrial septum near the presumed site of Bachmann's bundle in sinus rhythm showed a similar fused pattern of CS activation. CONCLUSIONS: These results demonstrate different patterns of CS activation in CC Afl and C Afl in the majority of patients and are consistent with a model in which the left atrium is activated predominantly over Bachmann's bundle during C Afl and over the CS os in CC Afl. These findings may have implications for maintenance of Afl, interpretation of flutter wave morphology on surface ECG, and left atrial mechanical function in Afl.

Aged↗