PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Neonatal Screening”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Relation of basic and clinical research on foetal and neonatal thyroid pathology to neonatal thyroid screening.

In this short review the importance is emphasized of basic and clinical research in regard to the interpretation of screening results. This review covers foetal thyroid physiology during the first 48 h of life, the importance of thyroid hormones for normal brain development, the definition of a critical period which might explain intellectual abnormalities in 10-15% of detected hypothyroid children and the importance of autoimmunity in the aetiology and diagnosis of transient congenital hypothyroidism.

Animals↗

[Universal neonatal hearing screening of infants with otoacoustic emissions].

BACKGROUND: The incidence of congenital hearing impairment is 1-2/1,000--higher than for congenital hypothyroidism and phenylketonuria combined. Universal screening of hearing impairment has been introduced in many countries with portable otoacoustic emission (OAE) and/or automated auditory brainstem response (AABR), but not in Norway. This is the first Norwegian report on universal hearing screening of newborns before hospital discharge. MATERIALS AND METHODS: All newborns in Østfold County (n = 5,712) in 2000 and 2001 were offered an OAE test on the second day in nursery by a two-step model. After two tests without OAE signals bilaterally, the infants were referred to the audiology clinic. RESULTS: 98.8% of the newborns were tested. Of these, 97.0% had a pass response after two tests. 169 (3.0%) were referred to the audiology clinic; 15 were withdrawn from follow-up examination by their parents. 23 infants had auditory brainstem response audiometry done, and sensorineural hearing impairment was found in six (1.0/1,000). Three infants (0.6/1,000) had conductive hearing impairment. INTERPRETATION: Our screening model was appropriate and cost-effective. The incidence of congenital hearing impairment was similar to that reported by others. The number of parental refusals should be reduced. This may be achieved by adding an AABR to the two OAE tests.

Audiometry↗

[National neonatal hearing screening and Central Registry for Hearing Loss in Children].

Implementation of Central Registry for hearing loss in children can answer many questions about the frequency, etiology and habilitation of hearing impairment by infant. Precondition for realize is implementation of universal newborn hearing screening. With introduction this screening we decrease dramatically the age of children, of which we predict, diagnosed and intervened bilaterally hearing loss. Despite the progress of the medicine, in particularly of the genetic, the etiology of some cases with hearing loss stay unknown. Future investigations in this field, inclusive molecular-genetic, is necessary to determine hereditary hearing loss by children in Bulgaria.

Bulgaria↗

Quality control system for mass screening in Japan.

Japan was the first country to establish a nationwide quality control system. When the Japanese Federal Government initiated Nationwide Neonatal Screening in 1977, the system officially included a Quality Control (QC) System that should cover all screening laboratories in Japan. This QC system is quite different from that for usual clinical chemistry. The aim of the National QC System for Neonatal Screening is evaluation of the accuracy of the tests and evaluation of the ability to detect suspicious samples with very mild abnormalities. For accomplishing the aim, the QC center established an inter-laboratory QC survey Screening laboratories having weak points can be identified through the inter-laboratory QC survey, and the Center must find a way to improve the ability of these screening laboratories. This requires a nationwide consensus regarding the cut-off levels of tested materials. Based on the cooperation of the Societies For Mass-screening, of Inborn Errors of Metabolism and of Pediatric Endocrinology, we set low cutoff levels for each compound to minimize the number of false negative cases. The system also included the evaluation of the quality of essential screening reagents and the special filter paper for blood collection (in partnership with the production companies). For this purpose, we developed some new methods for evaluating the standard-compounds for the various screening tests exactly, except in the case of TSH screening.

Humans↗

Thyrotropin enzyme-immunoassay in dried blood spots: a spectrophotometric method for neonatal thyroid screening.

We describe an enzyme-immunoassay with photometric endpoint determination, suitable for the measurement of thyrotropin (TSH) in dried blood spotted on filter paper. Using reagents of a commercially available test kit provided for the measurement of thyrotropin in 200 microliter serum, we have adapted the method to the determination of thyrotropin in blood spots containing ca. 10 microliter blood. This was achieved by prolongation of the assay time from 3 to 20 hours, and by increasing the amount of enzyme-antibody complex. Precision and sensitivity of the blood spot assay are comparable to those of our in-house thyrotropin RIA, and the RIA/EIA correlation coefficient is 0.987 (n = 150). The advantages of EIA are the simplicity of the photometric end point determination (although strict time control has to be observed in order to avoid drifts in results), the long stability of reagents, and the non-isotopic label. The method therefore appears to be a suitable alternative to thyrotropin RIA for the determination of thyrotropin in neonatal thyroid screening.

Humans↗

Evaluation of the Glucometer Elite XL device for screening for neonatal hypoglycaemia.

UNLABELLED: To prevent persistent neurodevelopment and physical growth deficits in neonatal care, it is mandatory to determine blood glucose levels as quickly and precisely as possible, preferably using micro-methods. However, most commercially available instruments have not been validated and approved for this purpose. The aim of this study was to validate the Glucometer Elite XL, a newly developed device for point-of-care testing (POCT). In samples from 869 newborn infants, glucose levels were simultaneously measured by the Glucometer Elite XL in whole blood and by an accepted clinical laboratory method in haemolysed blood using the ECA 2000 device. An acceptable method agreement was found between the POCT and the ECA 2000 method (mean difference 0.013 mmol/l, SD 0.69). As determined by regression analysis (Passing-Bablok), the slope was 1.086 with a y-intercept of -0.4 mmol/l ( r =0.959, P <0.05). The differences between measurement pairs of both assays versus the haematocrit were negligible. With a cut-off for hypoglycaemia at 2.6 mmol/l glucose in haemolysed blood, the sensitivity of the POCT device was 0.63 and specificity was 0.98. Raising the cut-off of the Glucometer Elite XL to 3.2 mmol/l, the sensitivity and specificity incremented to 1.0 and 0.89, respectively. CONCLUSION: The Glucometer Elite XL instrument can be recommended for point-of-care blood glucose measurement in newborn infants if its character as a screening method is taken into account. To compensate deviating results, we advise to shift its cut-off for hypoglycaemia recognition to a safe threshold of 3.2 mmol/l. However, hypoglycaemia has to be confirmed by a valid glucose measurement in the clinical laboratory.

Blood Chemical Analysis↗

Neonatal hearing screening: modelling cost and effectiveness of hospital- and community-based screening.

BACKGROUND: Children with congenital hearing impairment benefit from early detection and management of their hearing loss. These and related considerations led to the recommendation of universal newborn hearing screening. In 2001 the first phase of a national Newborn Hearing Screening Programme (NHSP) was implemented in England. Objective of this study was to assess costs and effectiveness for hospital and community-based newborn hearing screening systems in England based on data from this first phase with regard to the effects of alterations to parameter values. METHODS DESIGN: Clinical effectiveness analysis using a Markov Model. OUTCOME MEASURE: quality weighted detected child months (QCM). RESULTS: Both hospital and community programmes yielded 794 QCM at the age of 6 months with total costs of 3,690,000 pound sterling per 100,000 screened children in hospital and 3,340,000 pound sterling in community. Simulated costs would be lower in hospital in 48% of the trials. Any statistically significant difference between hospital and community in prevalence, test sensitivity, test specificity and costs would result in significant differences in cost-effectiveness between hospital and community. CONCLUSION: This modelling exercise informs decision makers by a quantitative projection of available data and the explicit and transparent statements about assumptions and the degree of uncertainty. Further evaluation of the cost-effectiveness should focus on the potential differences in test parameters and prevalence in these two settings.

Community Health Services↗

The impact of information on maternal attitudes towards universal neonatal hearing screening.

In order to improve the acceptability of universal newborn hearing screening (UNHS) among parents, several authors have proposed that information about hearing screening be provided to them. The purpose of the present study was to test the hypothesis that mothers who are informed about their baby's hearing test are more likely to have a positive attitude towards hearing screening than are mothers who are not informed. Information given to mothers was assessed by three items concerning their involvement in their baby's hearing test. Subjects were 90 mothers who were interviewed during their stay at the maternity unit after delivery. Mothers' attitudes towards the screening were assessed through their answer to the following question: 'Should UNHS be performed despite the possibility that parents become worried by false-positive test results?' Mothers who answered 'Yes' were categorized as advocates of UNHS, whereas those who answered 'No' or 'Undecided' were categorized as sceptics. The great majority of mothers (84%) turned out to be advocates. In keeping with the hypothesis, among advocates a significantly higher proportion of mothers were well-informed about the hearing test (78% versus 50%; p = 0.016), were present at the hearing test (51% versus 14%; p<0.01) or knew the result of the hearing test (71% versus 29%; p<0.01). These findings support the view that providing information about the hearing test will positively affect parental attitude towards UNHS.

Attitude to Health↗

A screening method for biotinidase deficiency in newborns.

We describe a method for neonatal screening for biotinidase (EC 3.5.1.12) deficiency. Biotinidase activity is assessed colorimetrically from dried samples of whole blood spotted on the same filter papers as used in the neonatal screening for phenylketonuria. After the reaction, samples from normal infants are characteristically purple, whereas those from affected individuals are straw-colored. To confirm the deficiency, the enzyme is quantitatively assayed in additional blood spots or serum. A pilot study has been initiated with samples obtained by the Commonwealth of Virginia for phenylketonuria testing.

Amidohydrolases↗

Early intervention after universal neonatal hearing screening: impact on outcomes.

This article summarizes the developmental outcomes of Colorado children with significant hearing loss. Some of the research compares children born in hospitals that have implemented universal newborn hearing screening programs for newborns. Other research compares the developmental outcomes of children who have been early-identified with hearing loss. Early-identification is defined as identification of hearing loss within the first six months of life. Late identification in the Colorado studies is defined as age of identification of hearing loss after the age of six months. In a few of the Colorado studies, age at initiation of intervention was used. Within the Colorado system, age of identification can be interpreted as almost synonymous with age of intervention, as the vast majority of children enter intervention services with two months after the identification of the hearing loss. Children who were early-identified and had early initiation of intervention services (within the first year of life) had significantly better vocabulary, general language abilities, speech intelligibility and phoneme repertoires, syntax as measured by mean length of utterance, social-emotional development, parental bonding, and parental grief resolution. Two other studies (Nebraska and Washington state) of early- versus later-initiation of intervention services report findings similar to the Colorado studies. Direct comparisons with the historical literature are not possible because the developmental delays of what would now be termed "later-identified" were too low to report developmental ages for the birth through five-year-old population.

Child, Preschool↗

Psychosocial aspects of genetic screening of pregnant women and newborns: a systematic review.

OBJECTIVES: To address five broad questions concerned with knowledge, anxiety, factors associated with participation/non-participation in screening programmes and the long-term sequelae of false-positive, true-positive in newborns and true-negative results. DATA SOURCES: Five electronic databases, two journals and attempts were made to locate unpublished work. REVIEW METHODS: This review started from a substantial literature base that provided the basis for (a) scoping the literature, (b) informing search strategy terms and (c) identifying preliminary article inclusion and exclusion criteria. The main eligibility criteria were: any screening programme aimed at pregnant women or newborn babies that included a 'genetic' target condition, this included chromosomal anomalies; any study that reported psychosocial data collected directly from parents. The data extraction form developed for this study elicited data from the selected studies. The data were entered into a database, which provided a summary of the included papers. RESULTS: A total of 288 candidate publications were identified, 106 of which were eligible: 78 were concerned with antenatal screening and 28 with newborn screening. It was found that levels of knowledge adequate for decision-making were not being achieved despite information leaflets and videos having some effect. Studies that have succeeded in increasing knowledge have not observed a corresponding increase in anxiety, although some anxiety might be an appropriate response and may aid coping and decision-making. Anxiety is clearly raised in women receiving positive screening results, especially young women. However, evidence is lacking of a beneficial (i.e. reassuring) effect of receiving a screen-negative result. Anxiety in screen-positive women falls on receipt of subsequent reassuring results, but some residual anxiety may remain. A minority (perhaps up to 30%) of women receiving a screen-positive result in pregnancy expressed regret about their screening decision. Uptake of neonatal screening has been treated as a 'given' and not as a research topic. CONCLUSIONS: The results of this review have many implications for the work of the National Screening Committee. The most pressing of these, in order of priority, relate to: the inadequacy of current procedures for achieving informed consent; the cost of providing a satisfactory service; the unmet needs of 'false-positives', and the unmet needs of women's partners, particularly in carrier screening. It is suggested that research is conducted on the above four topics in order to fill gaps in the evidence base that relate to screening technologies which have been available for many years. In addition, future screening programmes will create a new list of research questions, based on the same main agenda but applied to new areas, for example, new conditions such as haemoglobinopathies and fragile X syndrome; new client groups such as young women and minority ethnic groups; and new testing modalities such as ultrasound.

Adult↗

[Congenital transient hypothyroidism: characteristics of children identified at Newborn Screening Program of the State of Minas Gerais, Brazil].

Early diagnosis and treatment of congenital hypothyroidism are the main goals of the neonatal screening programs. A retrospective analysis was carried out to assess the characteristics and etiologies of congenital transient hypothyroidism (CTH) in the Newborn Screening Program of the State of Minas Gerais, Brazil. To reach a diagnosis of CTH, altered screening and serum confirmatory T4 and TSH tests and normal serum free T4 and TSH at 4 and 8 weeks after the withdrawal of levothyroxine were used. We studied 21 children with CTH who represented 4.23% of the whole group with detected hypothyroidism and followed them up in the Screening Program. These patients received LT4 therapy for a variable period of one month to three years. Serum confirmatory TSH levels varied from 10.4 to 583.4 microUI/mL. Maternal antibodies, TRAB and anti-TPO, were associated to CTH in two children and iodine overload in one of them. We concluded that CTH is an important component in neonatal screening and hormonal treatment during the first months of the life is essential. The TSH initial levels are not relevant to determine whether the thyroid dysfunction is transient or permanent.

Autoantibodies↗

Evaluation of growth and changes in body composition following neonatal diagnosis of cystic fibrosis.

Early deficits in nutritional status that might require specific treatment and early response to nutritional therapy were studied longitudinally in 25 infants with cystic fibrosis (CF) diagnosed by neonatal screening, using anthropometric and research body composition methodology, and evaluation of pancreatic function. At the time of confirmed diagnosis (mean 5.4 weeks), body mass, length, total body fat (TBF), and total body potassium (TBK) were all significantly reduced. Following diagnosis and commencement of therapy there was a normalization of weight, length, and TBK by 6-12 months of age, indicating catch-up growth. But in some individuals the response was incomplete, and as a group, mean total body fat remained significantly lower than normal at 1 year of age. Seven of 25 (28%) were pancreatic sufficient at diagnosis, and all but one had evidence of declining pancreatic function requiring the institution of pancreatic enzyme therapy during the next 1-9 months. The median age of commencement of enzyme therapy was 10 weeks (range 5 weeks to 11 months). These longitudinal assessments emphasize the dynamic changes occurring in absorptive function, body composition, and nutritional status following neonatal diagnosis of cystic fibrosis and may reflect previously described abnormalities of energy metabolism in this age group. Abnormal body composition is evident in most CF infants following diagnosis by neonatal screening but pancreatic damage may still be evolving. We suggest that early active nutritional therapy and surveillance for changes in pancreatic function are warranted in CF infants diagnosed by neonatal screening.

Body Composition↗

Congenital anomalies in infants with congenital hypothyroidism: is it a coincidental or an associated finding?

During the period between December 1988 and February 1995, a total of 279,482 newborn infants were screened in the regional neonatal screening program for congenital hypothyroidism (CH) in Riyadh province, Saudi Arabia. Eighty-one infants were confirmed to have CH giving an incidence of 1 in 3,450. Variable congenital anomalies, other than those of the thyroid gland, were present in 16 (19.8%). The anomalies most frequently encountered were congenital heart defects (7), unclassified multiple congenital anomalies (5) and Down's syndrome (2). The results of our study confirm this association, and emphasize the need to search for such anomalies in infants born with CH. Nationwide studies, however, on birth defects in the general population and those associated with CH are still needed to help us understanding the role of local genetic and environmental factors.

Abnormalities, Multiple↗

Congenital hypothyroid screening using cord blood TSH.

BACKGROUND: Clinical diagnosis of congenital hypothyroidism (CH) is difficult at birth without neonatal screening. In line with the priorities of the national health services in Malaysia towards preventive medicine, early diagnosis and treatment of CH is emphasised. We conducted a pilot study at Kuala Lumpur's Maternity Hospital between April 1995 and November 1995 to estimate the incidence of CH and also evaluated the problems associated with large-scale neonatal screening using a commercial TSH kit on cord bloodspots. PATIENTS: A total of 11,000 newborns were screened using cord blood spots taken at birth. RESULTS: Two hundred and fifty newborns (2.27%) hand cord TSH > 20 mlU/L and had to be recalled for re-evaluation. Of these, 4 had cord TSH of > 100 mlU/L; three were confirmed to have congenital hypothyroidism and one had transient hyperthyrotropinaemia. Our study estimated the incidence of CH to be one in 3,666 live births in Kuala Lumpur, Malaysia. Clinical features of hypothyroidism are subtle during the early weeks of life. However, prolonged neonatal jaundice (3/3), widely opened posterior fontanelle (3/3) and dry skin (3/3) were the common features in all our cases by 2-6 weeks of life. CONCLUSION: This study suffered a high dropout rate. Twenty-six percent of the patients were not traceable after discharge and 48% did not respond to our recall. We stress the importance of public education and awareness in contributing to the cost-effectiveness of the screening program.

Congenital Hypothyroidism↗

Newborn screening for cystic fibrosis using an enzyme linked immunoabsorbent assay (ELISA) technique.

Neonatal screening for cystic fibrosis (CF) has been conducted using conventional radioimmunoassay. An alternative immunoassay approach has been developed and applied to screening 35,550 newborns. Seventeen confirmed CF infants were detected by both assays. This monoclonal antibody-based enzyme immunoassay using microtitre plate ELISA technology has proved effective in case finding and offers a number of advantages. A reduced labour component, ease of handling, use of nonradioactive reagents, long reagent shelf-life, greater specificity and a reduction in potential sample handling and transposition errors combine to make this technology appropriate for a large volume neonatal screening laboratory.

Antibodies, Monoclonal↗

Congenital nephrotic syndrome detected by hypothyroid screening.

An infant was evaluated for a low thyroxine value, detected on routine neonatal screening for congenital hypothyroidism. She was found to have the congenital nephrotic syndrome, and to be euthyroid with low thyroid binding globulin. Congenital nephrosis can be detected by neonatal screening programs which use thyroxine as the primary screening test, but not by those which use TSH. This may be important in those countries in which the incidence of congenital nephrosis approaches that of congenital hypothyroidism.

Congenital Hypothyroidism↗

[Screening of newborn infants in Norway for severe metabolic disease].

The objective of neonatal screening for phenylketonuria and congenital hypothyroidism is early diagnosis and initiation of treatment to prevent brain damage and mental retardation. We present the results of the Norwegian national neonatal screening programme for phenylketonuria and congenital hypothyroidism. Screening for phenylketonuria based on serum phenylalanine determinations started in 1967 and covered the whole country in 1978. National screening for congenital hypothyroidism started in 1979. One hundred children with phenylketonuria and 280 children with a strong indication of congenital hypothyroidism have been detected up to 1 October 1994. Screening-related challenges and principles of treatment are discussed.

Congenital Hypothyroidism↗