Regional cerebral blood flow changes associated with emotions in children.

Combining a wireless telemetry system and a portable near-infrared instrument, we developed a movable optical spectroscopy system for monitoring cerebral hemodynamic changes. The patient carries a miniaturized near-infrared spectroscopy instrument on the back, and data are sent by a wireless telemetry system to a computer, without restricting patient movement. We used this system to detect hemodynamic changes associated with being startled, anticipation, and pleasant and unpleasant emotions in the bilateral prefrontal cortices of 16 right-handed 4- to 6-year-old preschool children while they were watching a 21-minute video clip consisting of various scenes that elicited emotional responses, interpolated with neutral scenes for comparison. The children were relaxed and cooperative when they were studied. Anticipation was associated with increases in cerebral blood flow in the left prefrontal cortex of the 6-year-old children, and unpleasant emotion was associated with decreases in cerebral blood flow bilaterally compared with neutral emotion, irrespective of age. No hemodynamic changes associated with the startle response were observed. Although this study should be considered preliminary, it is suggested that the emotional response is age-dependent and that the left prefrontal cortex participates in anticipation. Our newly developed system will open a window into brain physiology in children.

Child↗

A new screening model for safety evaluation of superantigen-antibody recombinant fusion proteins (mAb Fab-SEA/E) using telemetric monitoring in conscious rabbits.

INTRODUCTION: Carcinoma recognising monoclonal antibodies (mAb) and mutated forms of the T-cell-activating bacterial staphylococcal enterotoxin A/E (SEA/E) have been combined in single hybrid constructs (mAb Fab-SEA/E). By introducing substitutions in an MHC class II binding site, these harmful toxins can be converted into tolerable immunotoxins. Rabbits and humans are sensitive to SE toxins, and cardiovascular effects in rabbits are similar to those seen in septic shock in man. A new screening model using telemetry in conscious rabbits was applied in the safety evaluation of different mAb Fab-SEA/E constructs administered intravenously. METHODS: Telemetry transmitters were implanted in the peritoneal cavity of animals with a pressure catheter in the aorta and electrodes for ECG recording subcutaneously following administration of mAb Fab-SEA/E constructs intravenously. RESULTS: The responses in body temperature, heart rate, and blood pressure varied depending on the treatment regimen and the mutations of the drug given. For example, 25 micro g/kg of C215 Fab-SEAmut9 were given as a first treatment cycle on days 1, 5, and 7 and as a second treatment cycle on days 13-15. The first dose induced high fever, whereas the second and third doses induced fever responses more rapidly and were of lower and shorter duration. The second treatment cycle, starting on day 13, did not induce any responses probably due to anti-SEA antibodies formed because of the treatment. Another construct, 5T4 Fab-SEA/E-11 at 50 micro g/kg, induced a similar response as C215 Fab-SEAmut9 on days 1, 5, and 7. In this case, the pharmacologic response was still present on days 13-15, though no clinical signs developed or no formation of anti-SEA antibodies occurred. When 50 micro g/kg of 5T4 Fab-SEA/E-11 was administered once daily for 4 days, body temperature after the first dose increased slowly during the first 24 h, whereas the second to fourth doses induced more rapid and higher responses. The fourth dose of another compound, K305 Fab-SEA/E-11 (50 micro g/kg), induced an even more pronounced response both in magnitude and in duration as well as in adverse clinical signs. DISCUSSION: By using continuous telemetric registration in the rabbit as a tool in superantigen-antibody (mAb Fab-SEA/E) drug selection, it has been possible to evaluate the dynamics of drug-induced immune effects (fever) and concomitant engagement of the cardiovascular system, conditions that are essential before clinical trials can be initiated.

Animals↗

Application of computer-assisted radiotelemetry in the pharmacokinetic and pharmacodynamic modeling of procainamide and N-acetylprocainamide.

The cardiovascular pharmacodynamics (PD) of procainamide and N-acetylprocainamide have not been well characterized in small rodents without the presence of anesthesia or restraint. This study was undertaken to examine the pharmacokinetics (PK) and PD relationship of procainamide and N-acetylprocainamide by use of electrocardiogram (ECG) telemetry in unrestrained rats. Male Sprague Dawley rats received the following treatments: vehicle, procainamide 50 and 100 mg/kg and N-acetylprocainamide 50 and 100 mg/kg via intraperitoneal (i.p.) administration. Blood samples were collected over 8 h and subsequently analyzed. PD measurements (PQ, QS, QR, QT, RR, and HR) were collected prior to dosing and over a 24 h period. Mean PK parameters after the 50 mg/kg dose were as follows: Cls/Fprocainamide = 86.42 mL min-1 kg-1, Cls/FN-acetylprocainamide = 36.62 mL min-1 kg-1, Vdprocainamide = 10.42 L/kg, and VdN-acetylprocainamide = 5.91 L/kg. The relationship between concentration (procainamide or N-acetylprocainamide) and effect (percent change QT interval) was best described by an Emax model for procainamide (EC50 = 445 ng/mL; Emax = 30.09%). These results approximate ECG changes noted in procainamide clinical studies, suggesting that telemetry can be used as a predictive tool of efficacy. Furthermore, the proposed PK-PD model describes the electrophysiological effects associated with procainamide.

Acecainide↗

Ginkgo biloba extract attenuates the development of hypertension in deoxycorticosterone acetate-salt hypertensive rats.

1. We examined the effects of Ginkgo biloba extract (GBE) on the development of hypertension, platelet activation and renal dysfunction in deoxycorticosterone acetate (DOCA)-salt hypertensive rats. Both DOCA-salt hypertensive rats and normotensive rats were fed a 2% GBE diet for 20 days. Blood pressure (BP) was measured by two methods, namely by the tail-cuff and telemetry methods. 2. Development of hypertension was attenuated in rats fed a 2% GBE diet. In addition, an increase in heart weight, an indicator of sustained high BP, was inhibited significantly by feeding of the GBE diet. 3. Decreases in 5-hydroxytryptamine content in platelets, a marker of platelet activation in vivo associated with hypertension, were also prevented by feeding of the GBE diet. Ginkgo biloba extract itself did not inhibit ADP- and collagen-induced platelet aggregation examined in vitro. Feeding of the GBE diet tended to inhibit increases in plasma urea nitrogen due to hypertension. 4. The telemetry study demonstrated that BP and heart rate (HR) showed a clear circadian rhythm and the antihypertensive effect of GBE was prominent in the daytime, a resting period for rats. This anti-hypertensive effect of GBE was not detected in normotensive rats. In contrast, the inhibitory effect of GBE on HR was independent of time and was observed in both normotensive and hypertensive rats. 5. These results indicate that GBE has an anti-hypertensive and bradycardiac action, which are time dependent and independent, respectively. Thus, it appears that the chronopharmacological action of GBE may be ascribed not to pharmacokinetic factors, but rather to a circadian susceptibility rhythm to GBE in DOCA-salt hypertensive rats.

Animals↗

Comparison of telemetric and tail-cuff blood pressure monitoring in adrenocorticotrophic hormone-treated rats.

1. The aim of the present study was to validate a telemetric blood pressure (BP) monitoring system against tail-cuff blood pressure in both adrenocorticotrophic hormone (ACTH)- and sham-treated rats. In the statistical analyses, we first tested whether there was a detectable effect on systolic blood pressure (SBP) of 10 days treatment with ACTH compared with saline. Second, we compared results of telemetered and tail-cuff measurements and, third, we developed a novel method for estimating the relative power of the two techniques. 2. Twenty-three male Sprague-Dawley rats were randomly divided into two groups: (i) ACTH (100 microg/kg per day, s.c; n = 12) treated; or (ii) sham treated (0.9% saline, s.c; n = 11). Systolic BP was measured by the telemetric system (sampled for 10 s every 2 min) continuously for 4 h (n = 16) or for 30 min (n = 23) and also by the indirect tail-cuff method daily (n = 23). Data were compared within and between groups; ordinary least products (OLP) regression analysis was then performed to test for bias between the two methods. Sample size/power estimations were also performed. 3. Adrenocorticotrophic hormone treatment raised telemetered SBP by 11 mmHg (P < 0.001) compared with 14 mmHg (P < 0.001) using the tail-cuff method. There was no fixed or proportional bias between the two methods of measurement, as shown by regression analysis. Power calculations indicate that a minimum sample size of six gives a power of telemetered to tail-cuff of 0.84/0.86 = 0.98. The power of 4 h versus 30 min BP measurements was 0.99/0.82 = 1.2. 4. Telemetry gave very similar results to the tail-cuff method. Telemetry allows for a longer period of measurement, giving greater power to the study so that fewer animals are needed.

Adrenocorticotropic Hormone↗

Recording soccer players' heart rates during matches.

The aim of this study was to examine the possibility of obtaining information about the heart rate and physiological load imposed on soccer players during a game. The study was conducted on 27 soccer players, 9 each from semi-professional, university and recreational soccer teams. Players from all positions (attack, midfield and defence) were selected for the study. Each subject's heart rate was monitored during a match using a short-range radio telemetry (Sport Tester PE3000), and was sampled at 5-s intervals. The results indicate that it is possible to monitor successfully the heart rate of players with such equipment. The mean heart rate and standard deviation for each player during match play were: semi-professional players (172 +/- 12, 176 +/- 9 and 166 +/- 15 for forwards, midfielders and defenders, respectively); university players (171 +/- 13, 173 +/- 10 and 156 +/- 13 for forwards, midfielders and defenders, respectively); and recreational players (173 +/- 13, 170 +/- 12 and 162 +/- 13 for forwards, midfielders and defenders, respectively). Analysis by playing position revealed that midfield and forward players has a greater mean heart rate during a game than defensive players. To examine the suitability and accuracy of the two methods of obtaining objective data on heart rate, comparisons were made between the Sport Tester PE3000 and a standard electrocardiograph (ECG) telemetry technique. The results show that both techniques produce similar results; the former was the more convenient.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Assessment of work capacity in patients with ischaemic heart disease: methods and practices.

Analysis of 1150 post-infarct and post-aorto-coronary bypass graft patients referred to the Toronto Rehabilitation Centre revealed that approximately 10% have not returned to work six months after the acute event. White-collar workers are more successful than blue-collar workers in resuming work, as are those medically treated as compared with the surgically treated. The reasons for prolonged unemployment were more frequently non-medical than medical. Detailed assessment is required where there is doubt about the patient's work capacity, or where legislation and/or trade practices demand it. The simplest procedure is an exercise test with energy cost matching. Telemetry during simulated work tasks or while on work stations in the Centre allows more flexibility, with actual observation and telemetry on the job site the only recourse in certain situations.

Canada↗

Recent improvements in a completely implanted total artificial heart.

The total artificial heart under development by the Pennsylvania State University and 3M Health Care has undergone a number of design improvements to improve reliability, manufacturability, implantability, and performance. These improvements are nearing completion in preparation for formal durability testing. The redesigned implanted electronics canister, consisting of a welded titanium shell with hermetic connectors, contains the control, telemetry, and energy transmission electronics, as well as a 9 cell, 800 mAhr Ni-Cd battery pack. Functional changes include a reduction in the battery recharge time from 14 hours to 4 hours, and a new inductive telemetry system. The energy transmission system operating frequency has been increased from 160 kHz to 200 kHz. Electromagnetic interference filters and a more efficient control mode have also been implemented. The energy converter has been modified to incorporate a new motor with integral Hall effect position sensors, and new cable, and compliance chamber conduit fittings. High flex life cable is now used for the motor and coil cables. Two prototype durability mock circulatory loops have been built and are being tested. Substantial progress has been made in the completion of manufacturing documentation, and in the implementation of a quality system.

Animals↗

Daytime outpatient versus inpatient video-EEG monitoring for presurgical evaluation in temporal lobe epilepsy.

Video-EEG monitoring documentation of seizure localization is one of the most important aspects of a presurgical investigation in refractory temporal lobe epilepsy (TLE) patients. The objective of this study was to evaluate the efficacy of inpatient versus daytime outpatient telemetry. The authors evaluated prospectively 73 patients with medically intractable TLE. Ninety-one telemetry sessions were performed: 35 as inpatients and 56 as outpatients. Outpatient monitoring was performed in the EEG laboratory. They used 18-channel digital EEG. Medications were not changed in the outpatient group. For analysis of the data, time was counted in periods (12 hours = 1 period). Statistical analyses were performed using Student's t-test and the chi2 test. There were no differences between the two groups (outpatient versus inpatient) with respect to age and mean seizure frequency before monitoring, mean time to record the first seizure (1.1 versus 1.4 periods), mean number of seizures per period (0.6 for both groups), lateralization by interictal spiking (46% versus 57%), and lateralization by ictal EEG (59% versus 77%). Daytime outpatient video-EEG monitoring for presurgical evaluation is efficient and comparable with inpatient monitoring. Therefore, the improved cost benefit of outpatient monitoring may increase the access to surgery for individuals with intractable TLE.

Adolescent↗

Remote monitoring. Expanding a successful system.

A successful telemetry placement system moves into five medical/surgical areas and two step-down units. The updated equipment included an alarm gateway with an arrhythmia detection system. Telemetry signals are transmitted to a pager worn by nurses; remote display monitors allow nurses to eyeball arrhythmias and reset their alarm without going to a central station.

Equipment Failure↗

Real-time in vivo loading in the lumbar spine: part 1. Interbody implant: load cell design and preliminary results.

STUDY DESIGN: Instrumented interbody implants were placed into the disc space of a motion segment in two baboons. During the animal's activities, implants directly measured in vivo loads in the lumbar spine by telemetry transmitter. OBJECTIVES: Develop and test an interbody implant-load cell and use the implant to measure directly loads imposed on the lumbar spine of the baboon, a semiupright animal. SUMMARY OF BACKGROUND DATA: In vivo forces in the lumbar spine have been estimated using body weight calculations, moment arm models, dynamic chain models, electromyogram measurements, and intervertebral disc pressure measurements. METHODS: An analytical model was used to determine the force-strain relation in a customized interbody implant. After validation by finite element modeling, strain gauges were mounted onto the implant and connected to a telemetry transmitter. Implants were placed surgically into the L4-L5 disc space of skeletally mature baboons and the transmitter in the flank. After surgery, load data were collected from the animals during activities. Radiographs were taken monthly to assess fusion. RESULTS: The implant-load cell is sufficiently sensitive to monitor dynamic changes in strain and load. During extreme activity, highest measurable strain values were indicative of loads in excess of 2.8 times body weight. CONCLUSIONS: The study technique and technology are efficacious for measuring real-time in vivo loads in the spine. Measuring load on an intradiscal implant over the course of healing provides key information about the mechanics of this process. Loads may be used to indicate performance demands on the intervertebral disc and interbody implants for subsequent implant design.

Animals↗

A programmable microsystem using system-on-chip for real-time biotelemetry.

A telemetry microsystem, including multiple sensors, integrated instrumentation and a wireless interface has been implemented. We have employed a methodology akin to that for System-on-Chip microelectronics to design an integrated circuit instrument containing several "intellectual property" blocks that will enable convenient reuse of modules in future projects. The present system was optimized for low-power and included mixed-signal sensor circuits, a programmable digital system, a feedback clock control loop and RF circuits integrated on a 5 mm x 5 mm silicon chip using a 0.6 microm, 3.3 V CMOS process. Undesirable signal coupling between circuit components has been investigated and current injection into sensitive instrumentation nodes was minimized by careful floor-planning. The chip, the sensors, a magnetic induction-based transmitter and two silver oxide cells were packaged into a 36 mm x 12 mm capsule format. A base station was built in order to retrieve the data from the microsystem in real-time. The base station was designed to be adaptive and timing tolerant since the microsystem design was simplified to reduce power consumption and size. The telemetry system was found to have a packet error rate of 10(-3) using an asynchronous simplex link. Trials in animal carcasses were carried out to show that the transmitter was as effective as a conventional RF device whilst consuming less power.

Computer Systems↗

Quantitative analysis of bottlenose dolphin movement patterns and their relationship with foraging.

1. Broad-scale telemetry studies have greatly improved our understanding of the ranging patterns and habitat-use of many large vertebrates. However, there often remains considerable uncertainty over the function of different areas or the factors influencing habitat selection. Further insights into these processes can be obtained through analyses of finer scale movement patterns. For example, search behaviour may be modified in response to prey distribution and abundance. 2. In this study, quantitative analysis techniques are applied to the movements of bottlenose dolphins, recorded from land using a theodolite, to increase our understanding of their foraging strategies. Movements were modelled as a correlated random walk (CRW) and a biased random walk (BRW) to identify movement types and using a first-passage time (FPT) approach, which quantifies the time allocated to different areas and identifies the location and spatial scale of intensive search effort. 3. Only a quarter of the tracks were classed as CRW movement. Turning angle and directionality appeared to be key factors in determining the type of movement adopted. A high degree of overlap in search effort between separate movement paths indicated that there were small key sites (0.3 km radius) within the study area (4 km(2)). Foraging behaviour occurred mainly within these intensive search areas, indicating that they were feeding sites. 4. This approach provides a quantitative method of identifying important foraging areas and their spatial scale. Such techniques could be applied to movement paths for a variety of species derived from telemetry studies and increase our understanding of their foraging strategies.

Animals↗

Psychiatric outcome after temporal lobectomy: a predictive study.

PURPOSE: The occurrence of psychiatric symptoms after temporal lobectomy is well documented. The aim of the present study was to identify preoperative factors that predict postoperative psychiatric outcome. METHODS: We studied the case notes of 121 patients (from an initial sample of 167) who underwent temporal lobectomy at the National Hospital of Neurology and Neurosurgery, Queen Square, London, between 1988 and 1997. Data concerning gender, laterality of lesion, pathology, seizure outcome, psychiatric history, psychiatric outcome, resection volume, telemetry, and MRI scans were systematically collected. Factors that predict the occurrence of postoperative psychiatric symptomatology were investigated using correlational, chi(2), and logistic regression techniques. RESULTS: Poor postoperative psychiatric outcome in general was positively associated with preoperative bilateral independent spike discharges at telemetry. The size of surgical resection was positively correlated with the occurrence of postoperative emotional lability. The laterality of the epileptogenic lesion was not associated with a poor psychiatric outcome. Developmental lesions were associated with a good psychiatric outcome at a marginally significant level. Patients with a preoperative psychiatric history and de novo psychiatric symptomatology had a poorer surgical outcome in terms of seizure frequency, also at a marginally significant level. A significant correlation was found between a past psychiatric history and seizure outcome. CONCLUSIONS: We identified a high frequency of psychiatric symptoms both before and after temporal lobectomy, demonstrating that it is not a benign procedure from the point of view of psychopathology. Our results show that there are certain predictive factors that may help identify patients most at risk for postoperative psychiatric disorders.

Adult↗

From clinical observation to long-term monitoring: diagnostic developments in conservative epileptology.

The diagnostic goals in nonsurgical (conservative) epileptology differ from presurgical diagnostic aims. The resulting development of diagnostic methods in a tertiary-level epilepsy center is shown and the major technical and organizational consequences of this difference for diagnostic long-term monitoring (LTM) as opposed to presurgical LTM are investigated. A total of 133 consecutive daytime LTM investigations using radio telemetry were reviewed and seizure parameters such as type, duration, method of seizure detection, and need of mobility were evaluated and compared to presurgical LTM. Compared to presurgical LTM, partial seizures were relatively rare (17.8%) and short epileptic or nonepileptic motor events lasting <1 s, such as myoclonic, atonic, short tonic seizures, spasms, tics, or startle reactions, are frequent (34.9%). Of all seizures, 23% had no or minor ictal EEG changes, subtle symptomatology without signaling by a patient or accompanying person, and could be detected only by continuous online surveillance by an experienced EEG technician. Due to the nature of the patient population in diagnostic LTM, there is an increased need for ictal and interictal mobility (radio telemetry). LTM in conservative epileptology requires more intense human surveillance for seizure detection and increased patient mobility compared to presurgical LTM.

Adolescent↗

Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators.

The incidence and cause of electrocardiographically documented spontaneous implantable cardioverter defibrillator (ICD) discharges for a rhythm other than ventricular tachycardia (VT) or fibrillation (VF) (unnecessary shocks) were determined in 241 patients who underwent ICD implantation between March 1983 and November 1991. During follow-up of 24 +/- 20 months, 54 of 241 patients (22%) received a total of 132 unnecessary ICD shocks confirmed by Holter or telemetry monitoring or stored electrograms (Egs) from the ICD. The rhythm preceding these unnecessary ICD shocks was atrial fibrillation in 30 patients, sinus or supraventricular tachycardia (SVT) in 11 patients, antitachycardia pacing triggered by atrial fibrillation or SVT resulting in VT in 5 patients, nonsustained VT in 3 patients, and normal sinus or pacemaker rhythm in 10 patients. Unnecessary ICD discharges occurred most frequently during the first week after implantation or generator replacement (18 of 54 patients [33%]). Unnecessary ICD discharges could be documented more often by stored Egs in patients with devices with Eg storage capability (Ventritex Cadence, 19 of 54 patients [35%]) than by Holter or telemetry monitoring in patients with devices without Egs storage capabilities (34 of 193 patients [18%], P < 0.01), despite a shorter mean follow-up duration of 14 +/- 9 months versus 26 +/- 21 months, respectively. Only six of 54 patients (11%) in whom unnecessary ICD discharges occurred had recurrent unnecessary shocks during 22 +/- 20 months of follow-up after treatment directed at the cause of the first episode or device reprogramming to preclude non-VT rhythm detection.(ABSTRACT TRUNCATED AT 250 WORDS)

Atrial Fibrillation↗

Changing trends in therapy delivery with a third generation noncommitted implantable defibrillator: results of a large single center clinical trial.

Thirty-four patients underwent implantation of a third generation ICD, the 4210 ATP, for sudden cardiac death or ventricular tachycardia. This device incorporates significant telemetry logs as well as a detailed analysis of each arrhythmia episode detected. During the period of clinical follow-up, a mean of 12.2 months, a total of 26,569 VT or VF detections were made. The vast majority of these were either due to atrial fibrillation, nonsustained VT, or "noise" detection, and only 6% led to device therapy. ATP was successful in 86.3% of episodes, with 3.5% accelerations and 2.4% failure of ATP trains. The majority of inappropriate therapy episodes were clustered in seven patients, and all were easily diagnosed with the aid of the extensive telemetry logs and sense histories. Of five late deaths, three were from congestive heart failure, one from cerebrovascular accident, and one unknown. These data reveal that this "tiered" therapy noncommitted ICD performs to expectations; the stored data is of significant value in diagnosing the cause of ICD therapy. In addition, ATP is an effective modality for termination of VT.

Aged↗

Holter recordings with continuous marker annotations: a new tool in pacemaker diagnostics.

UNLABELLED: Pacemakers provide marker annotations to facilitate the interpretation of pacemaker electrocardiograms (ECGs) and can be used in cases of suspected pacemaker malfunction or to understand pacemaker behavior. Due to the need for a programmer, only short-term evaluations are possible. We evaluated a prototype Telemetry Data Logger (TDL) designed to continuously transfer markers from the pacemaker to a conventional Holter recorder. A miniaturized telemetry receiving coil was attached to patient's skin above the pacemaker, which was programmed to transmit markers continuously. The TDL, which receives and converts markers into eight positive and eight negative deflections, ranging from -2.5 to +2.5 mV in amplitude, was connected to one channel of a conventional Holter recorder (Tracker 2). We performed 20 Holters in 13 patients who had implanted VDDR or DDDR devices from the same manufacturer and evaluated three versions of software. Marker transmission was possible in all patients, producing Holter ECGs with complete marker annotations. Artifacts occurred < 4% of the time. A 50-ms rectangular pulse was optimal for marker interpretation. The device, which was easy to use and well accepted by the patients, assisted in the diagnosis of inappropriate pacemaker programming, even when the surface ECG seemed to show regular pacemaker function. In the presence of low quality surface ECGs, marker annotations allowed the assessment of pacemaker function. The capability to annotate the onset of special algorithms, like tachycardia termination algorithms or mode switching, facilitates interpretation of pacemaker behavior, enabling a reliable assessment of the appropriateness of such algorithms. CONCLUSION: The TDL effectively enables pacemaker markers to be inscribed onto a conventional Holter recording, facilitating the interpretation of pacemaker ECGs and the diagnosis of inappropriate pacemaker programming even when not discernible from the surface ECG alone.

Algorithms↗