PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tools”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Diabetic foot care: developing culturally appropriate educational tools for Aboriginal and Torres Strait Islander peoples in the Northern Territory, Australia.

Evidence shows that Aboriginal and Torres Strait Islander people have the highest national percentage of morbidity in relation to diabetes. Aboriginal and Torres Strait Islander people also suffer the greatest risk of amputation as a complication of diabetes. This participatory action research project sought to discover the opinions of a range of people, including registered nurses, general practitioners, Aboriginal health workers, cross-cultural liaison officers and Aboriginal and Torres Strait Islander people with diabetes. Focus groups provided valuable information regarding relevant issues of foot care education in the Northern Territory. The emergent themes included communication issues, educational resources, changing behaviour and other practical resources required for health education. The themes provided evidence of the inherent issues of foot care for Aboriginal and Torres Strait Islander people and guidance for the development of a visual educational tool. The results have lead to the development of a foot care educational tool that will be used by health-care professionals and clients in urban, community, rural and remote areas. The use of a participant action research process will ensure that the educational tool will be owned by Aboriginal and Torres Strait Islander People and health-care professionals.

Attitude of Health Personnel↗

Validation of a malnutrition screening tool for patients receiving radiotherapy.

Nutrition screening identifies individuals who are malnourished or at risk of becoming malnourished and who may benefit from nutrition support. The aim of this study was to validate a new malnutrition screening tool (MST) in cancer patients undergoing radiotherapy. The MST was compared with the subjective global assessment (SGA) of nutritional status. One hundred and six patients attending two cancer care centres in Australia were independently rated as well nourished or malnourished using SGA and at risk or not at risk of malnutrition using the MST. Convergent validity of the MST was established by determining the ability of the MST to predict SGA. According to SGA, 89% of the patients were well nourished and 11% were moderately malnourished. According to the MST, 28% of patients were at risk of malnutrition. The MST had a sensitivity of 100% and a specificity of 81%. The positive predictive value was 0.4 and the negative predictive value was 1.0. The MST is easy to use and is a strong predictor of nutritional status. The malnutrition screening tool is a simple, quick, valid tool that can be used to identify radiation oncology outpatients who are at risk of malnutrition.

Adolescent↗

Pilot study of a pain assessment tool in the Neonatal Intensive Care Unit.

OBJECTIVES: To develop and validate a pain assessment tool to assess procedural pain experienced by mechanically ventilated neonates. METHODS: Assessment of ventilated infants, before, during and after a known routine traumatic procedure using the Nepean Neonatal Intensive Care Unit Pain Assessment Tool (NNICUPAT). This tool scores physiological and behavioural responses to pain. Variables used in the NNICUPAT included facial expression, body movement, skin colour, saturation, respiratory rate, heart rate and nurses' perception of pain. To test the validity of the NNICUPAT, it was compared to a visual analogue scale (VAS), which is a unidimesional observation measure, where zero equals no pain and 10 equals severe pain. RESULTS: Thirty ventilated neonates (mean gestation 28 +/- 3.3 standard deviation (SD)) weeks) were enrolled in the pilot study over a 9-month period. The total score before the procedure was: 0.26 +/- 0.14 (mean +/- standard error of the mean (SEM)) range 0-3; total score during the procedure 5.1 +/- 2.2 (mean +/- SD) range 1-10; and the total score after the procedure was 0.26 +/- 0.15 (mean +/- SEM) range 0-3. There was a significant correlation between the NNICUPAT and the VAS during the procedure (r = 0.825, P = < 0.01) and after the procedure (r = 0.375, P = < 0.05). Inter-rater reliability was calculated between the principle coder and other coders (using the NNICUPAT) and showed a significant correlation before (r = 0.88, P < 0.01) and during (r = 0.88, P < 0.01) the procedure. CONCLUSIONS: The NNICUPAT does show validity in the assessment of procedural pain in the ventilated neonate. Further evaluation of both inter- and intra-rater reliability will be necessary to establish the ongoing validity of the NNICUPAT.

Analysis of Variance↗

Ancillary tools in pacemaker and defibrillator lead extraction using a novel lead removal system.

A previous report described our preliminary experience with a highly successful pacing lead removal system (VasoExtor). Extending this experience, we found it necessary to use additional tools to enhance the success of percutaneous lead extraction with this system. In the present series, we used the standard locking stylets (S and K), and recently, one newer type of stylet (Magic) over the last 3 years in 34 patients to extract 48 pacemaker leads in 31 patients and 3 defibrillator (ICD) leads in 3 patients. Lead extraction was carried out in 23 men and 11 women (aged 64 +/- 17 years) because of pacemaker infection (n = 21), pacemaker (n = 8) or ICD (n = 3) lead malfunction, or prior to ICD implant (n = 2). Leads were in place for 3.5 +/- 3.7 years. Infections, involving pocket and lead(s), were due to S. epidermidis (n = 13), S. aureus (n = 6), S. aureus plus E. coli (n = 1), for fungi (n = 1). Of the 48 pacing leads, 31 were ventricular, 15 atrial, and 2 were VDD leads. The ICD leads were two double-coil leads (CPI) and one single-coil lead (Telectronics). Using the S (n = 12), K (n = 8), or Magic (n = 3) stylets, all pacing leads in 23 patients and the ICD leads in 2 patients were successfully removed from a subclavian approach using the locking stylets. However, in nine (26.5%) patients ancillary tools were required. In four patients, lead fragments were captured with use of a noose catheter, a pigtail catheter, and a bioptome from a right femoral approach. In two patients, locking could not be effected and a noose catheter from the right femoral vein was used, aided by a pigtail and an Amplatz catheter and a bioptome to remove three leads. In a patient with an ICD lead, a combined subclavian (stylet S) and right femoral approach (noose catheter) was required. In a patient with a dysfunctional ventricular lead 12 years old, a motor drive unit was used to facilitate the exchange of locking stylets, but extraction failed. In another patient, a fragment of a dysfunctional ventricular lead remained intravascularly despite resorting to a femoral approach. Finally, lead removal was completely (32/34, 94%) or partially (1/34, 3%) successful in 33 (97%) of 34 patients for 50 (98%) of 51 leads without complications. In conclusion, to enhance the success of pacing or ICD lead extraction with use of the VascoExtor locking stylets, an array of ancillary tools were required in more than one fourth of patients.

Adult↗

Extraction of pacemaker and implantable cardioverter defibrillator leads: patient and lead characteristics in relation to the requirement of extraction tools.

Effective tools for extraction of pacemaker and ICD leads have been developed in the past decennium. This study investigated the necessity of using these tools in addition to direct traction in relation to patient and lead characteristics. The study encompasses first attempts at extraction of consecutive pacemaker and ICD leads from the subpectoral area. A stepwise extraction protocol was used with traction first (directly or with a locking stylet) followed by laser sheath extraction if not successful. The indication, patient age, time from implant, fixation mechanism, location, and insertion site of the leads were studied in relation to the outcome of traction. A total of 145 leads in 83 patients were extracted. Leads were implanted for 71 +/- 61 months. Indication for extraction was infection in 96 leads and malfunction in 49 leads. There were 90 ventricular leads including 16 ICD leads. Forty-nine (34%) leads were extracted with traction; in 96 (66%) leads a laser sheath was necessary. All leads implanted for < 6 months could be removed with traction alone. In a multivariate logistic regression model, time from implant was the main factor determining success of traction (P < 0.001), but in case of infection the success rate increased (P = 0.004). In conclusion, time from implant is the decisive factor to judge the potential efficacy of lead extraction with direct traction. If leads are implanted for 6 months, the availability of additional extraction tools is necessary when lead extraction is considered. In addition to time from implant, infected leads have a better chance to be removed with traction although it is a much weaker predictor.

Defibrillators, Implantable↗

Validating the Derbyshire Children's Hospital Pain Tool: a pilot study.

BACKGROUND: The Derbyshire Children's Hospital Paediatric Pain Chart (DPC) is the current pain assessment tool used at the Derbyshire Children's Hospital. It was originally devised as a simple pain tool for use in the clinical area, and it is applicable for use in children of all ages within the postoperative setting. The pain assessment chart encompasses pain assessment by utilizing facial expression, body movement and verbal expression. An exploratory study was performed to define its reliability and validity. METHODS: The research nurse (V.P.) assessed 40 children aged 1-5 undergoing minor and intermediate surgery comparing the Toddler Preschooler Postoperative Pain Scale and the DPC. Assessments were performed preoperatively and for 4 h postoperatively. Any analgesia administered postoperatively was recorded. RESULTS: All the children scored 0 preoperatively with both pain scales, thus demonstrating known groups validity. There were 116 dual assessments by the research nurse using both pain scales. There was a strong correlation (r = 0.89) demonstrating convergent validity. There was a significant correlation between 182 joint assessments by the research nurse (V.P.) and the nursing staff using the DPC (Spearmans rank correlation, 0.81) and the Cronbach alpha coefficient ranged from 0.83 to 0.98. Construct validity was demonstrated by a fall in the mean pain scores from 1.8 to 0.1 following analgesia in 19 children. CONCLUSIONS: This exploratory study suggests the DPC holds construct, convergent and known groups validity and is a reliable pain assessment tool for children aged 1-5 years undergoing minor and intermediate surgery.

Child, Preschool↗

Biofeedback vs verbal feedback as learning tools for pelvic muscle exercises in the early management of urinary incontinence after radical prostatectomy.

OBJECTIVE: To evaluate the comparative effectiveness of electromyographic (EMG) biofeedback with verbal instructions as learning tools of pelvic muscle exercises (PMEs) in the early management of urinary incontinence after radical prostatectomy. PATIENTS AND METHODS: Forty-two consecutive patients (mean age 64 years, sd 4.2), with urinary incontinence after radical retropubic prostatectomy for localized prostate cancer, were randomized to receive biofeedback (group A, 28 men) or verbal feedback (group B, 14 men) as learning tools for PMEs immediately after catheter removal. Group A received 15 sessions of EMG biofeedback (three times weekly, 30 min each) and group B verbal instructions. Evaluation at baseline and 1, 2, 3 and 6 months included the 1-h pad-test and a questionnaire (number of pads/day and incontinence episodes). RESULTS: By the last follow-up, 27 patients had received biofeedback and 15 verbal instructions. Data were analysed according to the intention-to-treat principle. Urine loss as assessed by the 1-h pad-test at baseline, 1, 2, 3 and 6 months was 39, 18, 7, 4 and 3 g for group A and 31, 11, 3, 1 and 0 g for group B, respectively (P > 0.05). The number of pads/day was 3.9, 3.4, 1.2, 0.8 and 0.4 for group A and 3.6, 1.8, 0.9, 0.4 and 0.2 for group B, respectively (P > 0.05). The overall continence rate at 6 months was objectively (urine loss > 1 g) 91% and subjectively (0-1 pad/day) 95%. CONCLUSION: Intensive verbal instructions and biofeedback were both very effective behavioural methods and learning tools for PMEs in the early management of urinary incontinence after radical prostatectomy.

Biofeedback, Psychology↗

Validation of 2 depression screening tools in dialysis patients.

BACKGROUND: Depression is the most common psychiatric disorder in long-term dialysis patients and is a risk factor for morbidity and mortality. An efficient and valid method of diagnosing depression might facilitate recognition and treatment. We sought to validate 2 depression assessment tools, the 21-question Beck Depression Inventory (BDI) and the 9-question Patient Health Questionnaire (PHQ-9), in a dialysis population. METHODS: We surveyed patients who had received dialysis for at least 90 days in Portland, OR. We excluded patients with dementia, delirium, or a history of major psychiatric disorders other than depression. The Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, a gold-standard measure for depression, was administered by trained psychologists within 2 weeks of the BDI and PHQ-9. RESULTS: Of 62 enrolled subjects, 16 were diagnosed with a depressive disorder, including 12 patients (19%) with major depression, 3 patients with dysthymia, and 1 patient with minor depression. Optimal BDI and PHQ-9 cutoff values for depressive disorders combined was 16 or greater and 10 or greater, respectively. Sensitivities were 91% and 92%, specificities were 86% and 92%, positive predictive values were 59% and 71%, and negative predictive values were both 98%, with kappa values of 0.65 and 0.75, respectively. The difference between the 2 receiver operating characteristic curves was not statistically significant (P > 0.9). CONCLUSION: Our results validate the PHQ-9 and revalidate the BDI against a gold-standard measure for depressive disorders in the dialysis population. Both tools performed equally well. Because depression is prevalent, readily diagnosed, and associated with poor outcomes, screening by means of short and valid measurement tools may lead to better diagnosis and treatment of this modifiable risk factor. This may lead to improved clinical outcomes in dialysis patients.

Aged↗

MDCT pulmonary angiography: image processing tools.

The postprocessing of multidetector row computed tomography (MDCT) data sets is best termed "volume interrogation." Most techniques are best applied as problem-solving tools rather than as preset protocols, and radiologist involvement is essential. The ability to interact with an isotropic or nearly isotropic data set in near real-time is a tremendous advance, but is one that radiologists must rapidly embrace and master. This review begins with a discussion of the basic postprocessing tools relevant to the analysis of the pulmonary vasculature and proceeds to illustrate the clinical application of these techniques to the MDCT of acute and chronic thromboembolic disease. It is clear that in the era of MDCT, axial image review alone is rapidly becoming not only impractical, but also suboptimal. Reformatted images are also beneficial as communication tools for our referring colleagues and can enhance the role of the radiologist as part of the clinical team.

Angiography↗

The active movement scale: an evaluative tool for infants with obstetrical brachial plexus palsy.

Newborns with peripheral nerve lesions involving the upper extremity are difficult to evaluate. The reliability of the Active Movement Scale (AMS), a tool for assessing motor function in infants with obstetrical brachial plexus palsy (OBPP), was examined in 2 complementary studies. Part A was an interrater reliability study in which 63 infants younger than 1 year with OBPP were independently evaluated by 2 physical therapists using the AMS. The scores were compared for reliability and controlled for chance agreement by using kappa statistics. Overall kappa analysis of the 15 tested movements showed a moderate strength of score agreement (kappa = 0.51). Quadratic-weighted kappa (kappa(quad)) statistics showed that 8 of the 15 movements tested were in the highest strength of agreement category (kappa(quad) = 0.81-1.00). Five movements showed substantial agreement (kappa(quad) = 0.61-0.80), and 2 movements had moderate agreement (kappa(quad) = 0.41- 0.60). The overall kappa(quad) was 0.89. Part B was a variability study designed to examine the dispersion of scores when infants with OBPP were evaluated with the AMS by multiple raters. Ten pediatric physical therapists with varying degrees of experience using the scale attended a 1(1/2)-hour instructional workshop on administration of the tool for infants with OBPP. A chain-block study design was used to obtain 30 assessments of 10 infants by 10 raters. A 2-way analysis of variance indicated that the variability of scores due to rater factors was low compared with the variability due to patient factors and that variation in scores due to rater experience was minimal. The results of part A indicate that the AMS is a reliable tool for the assessment of infants with OBPP when raters familiar with the scale are compared. The results of part B suggest that, with minimal training, raters with a range of experience using the AMS are able to reliably evaluate infants with upper-extremity paralysis.

Brachial Plexus↗

Nursing in Colorectal Cancer Initiative: the audit phase. Part 2. Content validity of the audit tool and implications of the standards set for clinical practice.

This paper gives an account of the process of refining the content validity of an audit tool, which defines and measures best practice in colorectal cancer nursing and identifies areas for development. The European Oncology Nursing Society (EONS) and AstraZeneca collaborated to develop the Nursing in Colorectal Cancer Initiative (NICCI). The initiative was funded through educational grants from AstraZeneca and led by EONS. It is a project with two components, education and audit. The education component culminated in a manual that provides a core set of materials concerning fundamental aspects of colorectal cancer, to foster a common understanding amongst nurses at national and international levels. An audit tool was developed to measure standards of nursing care in relation to the delivery of cytotoxic chemotherapy to patients with advanced colorectal cancer. The content validity of the audit tool was established in three stages by expert panel review with revisions made to the content and organisation of the audit measures at each stage. The standards set by the NICCI Audit Project have key implications for multi-professional practice in colorectal cancer care.

Journal Article↗

[A software tool for automatic image-based ventilation analysis using dynamic chest CT-scanning in healthy and in ARDS lungs].

PURPOSE: Density measurements in dynamic CT image series of the lungs allow one to quantify ventilated, hyperinflated, and atelectatic pulmonary compartments with high temporal resolution. Fast automatic segmentation of lung parenchyma and a subsequent evaluation of it's respective density values are a prerequisite for any clinical application of this technique. MATERIAL AND METHODS: For automatic lung segmentation in thoracic CT scans, an algorithm was developed which uses (a) different density masks, and (b) anatomic knowledge to differentiate heart, diaphragm and chest wall from ventilated and atelectatic lung parenchyma. With Animal Care Committee approval, the automated technique was tested in 8 anaesthetized ventilated pigs undergoing dynamic CT before and after induction of lavage-ARDS. Images were acquired in one supradiaphragmatic, cross-sectional slice (temporal resolution of 100 ms; slice thickness of 1 mm, high resolution reconstruction algorithm). In 120 CT images the total pixel number and the calculated MLD from the automatically segmentated lung were compared to the values obtained from an interactive lung segmentation. RESULTS: The software tool was able to read all image series (DICOM standard). Automatic and interactive segmentation were in high agreement (R(2) = 0.99 for the total number of pixels and the MLD). Originally, the most frequent error was misclassification of atelectasis as extrapulmonary solid tissue. CONCLUSION: An automatic software tool is presented for lung segmentation in healthy lungs and in ARDS. Aerated lung and atelectasis were identified with high accuracy. This post-processing tool allows for a quantitative, CT based assessment of ventilation and recruitment processes in the lung. Thus, it may help to optimize ventilation patterns in patients with ARDS.

Animals↗

[Improving medical education in psychosocial disciplines by multimedia tools].

The use of multimedia tools is gaining increasing importance in medical education. These tools provide adequate techniques and possibilities for education within all medical including the psychosocial disciplines. Until now, a lack of multimedia learning programs and websites providing material related to psychosocial issues has to be considered in Germany. On the other hand, a new Medical Licensure Act (Approbationsordnung fuer Aerzte) will have a dramatic impact on medical education and teaching. On this basis there is a broad need for multimedialearning-environments, covering parts of the changes demanded by the new educational standards. Considering the lack of available multimedia learning programs and the need for those tools due to the medical education reform in Germany, the rapid development, validation and curricular implementation of those programs is required. This should be a goal of high priority, especially for the teaching of issues related to medical psychology, medical sociology, and psychosomatic medicine and psychotherapy.

Audiovisual Aids↗

[Which functional diagnostic tools do German coloproctologists favour?].

AIM: We tried to evaluate the role of anorectal functional diagnostic tools according to the judgement of German coloproctologists. METHOD: Questionnaires concerning accuracy of different diagnostic tests were sent to 585 physicians specialized in coloproctology. RESULTS: 261 (44.6 %) completed forms were returned. An analysis of the answers revealed that endorectal sonography is widely (73 %) regarded as useful and reliable diagnostic tool. Though manometry is still frequently used, only 50.5 % of the coloproctologists made their decision concerning the further treatment depending on the results of this method. Other radiologic methods as defecography and colon transit time are still regularly performed, though video-defecography is not accepted by most coloproctologists. Neurological investigations as pudendal nerve terminal latency, surface-EMG and needle-EMG are exclusively applied in specialized departments. DISCUSSION: Regarding the variety of diagnostic tools and its different appraisal a consensus should be defined. The usefulness of neurological examination techniques needs to be clarified before their performance can be recommended for a wide-spread routine work up.

Colonic Diseases↗

Multislice CT coronary angiography: evaluation of an automatic vessel detection tool.

PURPOSE: To investigate the potential of a new detection tool for multislice CT (MSCT) coronary angiography with automatic display of curved multiplanar reformations and orthogonal cross-sections. MATERIALS AND METHODS: Thirty-five patients were consecutively enrolled in a prospective intention-to-diagnose study and examined using a MSCT scanner with 16 x 0.5 mm detector collimation and 400 ms gantry rotation time (Aquilion, Toshiba). A multisegment algorithm using up to four segments was applied for ECG-gated reconstruction. Automatic and manual detection of coronary arteries was conducted using the coronary artery CT protocol of a workstation (Vitrea 2, Version 3.3, Vital Images) to detect significant stenoses (> or = 50 %) in all segments of > or = 1.5 mm in diameter. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of conventional coronary angiography. RESULTS: The overall sensitivity, specificity, nondiagnostic rate, and accuracy of the automatic and manual approach were 90 vs. 94 %, 89 vs. 84 %, 6 vs. 6 %, and 89 vs. 88 %, respectively (p = n. s.). The vessel length detected with the automatic and manual approach were highly correlated for the left main/left anterior descending (143 +/- 30 vs. 146 +/- 24 mm, r = 0.923, p < 0.001), left circumflex (94 +/- 35 vs. 93 +/- 33 mm, r = 0.945, p < 0.001), and right coronary artery (145 +/- 36 vs. 144 +/- 37 mm, r = 0.925, p < 0.001). The time required to create reformations along the coronary arteries was significantly shorter with the automatic tool compared to the manual approach (203 +/- 77 vs. 391 +/- 104 sec, p < 0.005). In 90 % of the coronary branches automatic detection required less time than the manual approach. CONCLUSION: Automatic coronary vessel detection is feasible and reduces the time required to create reformations by a factor of approximately two without deteriorating the diagnostic accuracy.

Aged↗

[Evaluation of a new software tool for the automatic volume calculation of hepatic tumors. First results].

PURPOSE: Computed tomography has become the preferred method in detecting liver carcinomas. The introduction of spiral CT added volumetric assessment of intrahepatic tumors, which was unattainable in the clinical routine with incremental CT due to complex planimetric revisions and excessive computing time. In an ongoing clinical study, a new software tool was tested for the automatic detection of tumor volume and the time needed for this procedure. MATERIALS AND METHODS: We analyzed patients suffering from hepatocellular carcinoma (HCC). All patients underwent treatment with repeated transcatheter chemoembolization of the hepatic arteria. The volumes of the HCC lesions detected in CT were measured with the new software tool in HepaVison (MeVis, Germany). The results were compared with manual planimetric calculation of the volume performed by three independent radiologists. RESULTS: Our first results in 16 patients show a correlation between the automatically and the manually calculated volumes (up to a difference of 2 ml) of 96.8 %. While the manual method of analyzing the volume of a lesion requires 2.5 minutes on average, the automatic method merely requires about 30 seconds of user interaction time. CONCLUSION: These preliminary results show a good correlation between automatic and manual calculations of the tumor volume. The new software tool requires less time for accurate determination of the tumor volume and can be applied in the daily clinical routine.

Algorithms↗

Application of the fetal alcohol syndrome facial photographic screening tool in a foster care population.

We determined the prevalence of fetal alcohol syndrome (FAS) in a foster care population and evaluated the performance of the FAS Facial Photographic Screening Tool. All children enrolled in a Washington State Foster Care Passport Program were screened for three conditions: (1) the FAS facial phenotype from a photograph, (2) evidence of brain damage with prenatal alcohol exposure from their Health and Education passport, and/or (3) other syndromes identifiable from a facial photograph. Screen-positives received diagnostic evaluations at a FAS Diagnostic and Prevention Network clinic. The prevalence of FAS in this foster care population was 10 to 15/1000, or 10 to 15 times greater than in the general population. The screening tool performed with 100% sensitivity, 99.8% specificity, 85.7% predictive value positive, and 100% predictive value negative. We conclude that the foster care population is a high-risk population for FAS. The screening tool performed with very high accuracy and could be used to track FAS prevalence over time in foster care to accurately assess the effectiveness of primary prevention efforts.

Child↗

Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool.

PURPOSE: The purpose of this study was to assess accuracy and reliability of a volumetric analysis of abdominal aneurysms on the basis of multidetector row computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) with a commercially available automated vessel analysis software program. MATERIALS AND METHODS: Twenty patients with abdominal aortic aneurysms underwent preoperative CTA and MRA before endovascular repair. Postdeployment CTA was performed in 15 of these 20 patients (75%). All preoperative CTA and MRA and postdeployment CTA data sets were analyzed with an automated software tool. The length of the stent grafts on postdeployment CTA was measured and compared with the true length of the primary component. Two readers independently evaluated 13 vessel parameters on preoperative CTA and MRA, which are considered to be important in planning stent graft deployment. RESULTS: With the automated analysis software tool, all measurements could be performed on either CTA or MRA data sets. There was no statistically significant difference between postdeployment measurements of stent graft length on CTA and the true dimensions of the implanted stent grafts. Interobserver agreement for all of the measurements with either CTA or MRA was good to excellent (interclass coefficient, 0.71 to 0.99) with only minimal mean differences of measured dimensions between both readers (range, -2.0 to +2.3 mm, Bland-Altman). Intermodality agreement between CTA and MRA was good to excellent (interclass coefficient, 0.62 to 0.98) with small mean differences of measured dimensions between both methods (range, -4.1 to +2.1 mm, Bland-Altman). CONCLUSION: Volumetric measurement with an automated analysis software tool allows a fast, precise, and reliable noninvasive preoperative determination of all aortic dimensions on the basis of either CTA or MRA data sets.

Aged↗