PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Volatile Organic Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Bio-effect monitoring using a [(15)N]methacetin test as diagnostic tool to monitor remediation effects in an industrially polluted region.

The classical way to demonstrate the efficiency of remediation is measuring the reduction of toxic compounds in the environment. Nevertheless, more important is the risk reduction in human health. To determine changing health effects, exposure and bio-effects have to be monitored at time of and during remediation. Kindergarten children from a heavily polluted industrial (n=23) and a control area (n=12) were investigated. The region-specific outdoor and indoor exposure [27 volatile organic compounds (VOC), emphasis on tri- and tetrachloroethylene (TRI, TETRA)], the internal load [(trichloroacetic acid-TCA-as urine metabolites of TRI and TETRA and S-phenyl- and S-benzylmercapturic acid (SPMA and SBMA) as metabolites of benzene and toluene], and biological effect assessment ([(15)N]methacetin test-a non-invasive stable isotope test to determine the unspecific liver detoxification capacity of an individual) were measured twice a year during 2 years of remediation (1997/1998). It could be shown that in- and outdoor levels of TRI and TETRA decreased by 47% in the heavily polluted village, Greppin, while the levels remained much the same in the control village, Roitzsch. This trend was reflected in the decreasing elimination of TCA in the urine (41%) by the Greppin children, with no differences in the TCA elimination in Roitzsch probands. As the remediation efforts decreased the burden of exposure, the children's liver detoxification capacity improved as well. Combining different methods, such as exposure-effect (external and internal loads) and bio-effect monitoring, proved to be useful to assess remediation successes including the improvement in human health.

Acetamides↗

Using 'mute' plants to translate volatile signals.

When attacked by herbivores, plants release volatile organic compounds (VOCs) that attract natural enemies of the herbivores and function as indirect defenses. Whether or not neighboring plants 'eavesdrop' on these VOCs remains controversial because most studies use unrealistic experimental conditions and VOC exposures. In order to manipulate exposures of wild-type (WT) Nicotiana attenuata'receiver' plants, we elicited transformed 'emitter' plants, whose production of herbivore-induced C6 green leaf volatiles (GLVs) or terpenoid volatiles was genetically silenced, and placed them up-wind of WT 'receiver' plants in open-flow experimental chambers. We compared the transcriptional and secondary metabolite defense responses of WT receiver plants exposed to VOCs from these transgenic emitter plants with those of plants exposed to VOCs from WT emitter plants. No differences in the constitutive accumulation of defense metabolites and the signal molecule jasmonic acid (JA) were found. Additional elicitation of receiver plants revealed that exposure to WT, GLV-deficient and terpenoid-deficient volatile blends did not prime induced defenses, JA accumulation, or the expression of lipoxygenase 3 (NaLOX3), a gene involved in JA biosynthesis. However, exposure to wound- and herbivore-induced VOCs significantly altered the transcriptional patterns in receiver plants. We identified GLV-dependent genes by complementing the GLV-deficient volatile blend with a mixture of synthetic GLVs. Blends deficient in GLVs or cis-alpha-bergamotene regulated numerous genes in receiver plants that did not respond to the complete VOC blends of WT emitters, indicating a suppressive effect of GLVs and terpenoids. Whether these transcriptional responses translate into changes in plant fitness in nature remains to be determined.

Organic Chemicals↗

Utilization of a multimembrane inlet and a cyclic sudden sampling introduction mode in membrane inlet mass spectrometry.

Sudden sampling introduction into a membrane inlet mass spectrometer (MIMS) considerably improves the selectivity of the membrane inlet and is therefore applicable even for compounds with low permeabilities through a silicone membrane. In this study the basics of cyclic non-steady-state sudden increase sample injection were studied using a three-membrane inlet and a portable sector double-focusing mass spectrometer. The operational parameters of the inlet system providing the most efficient enrichment of volatile organic compounds (VOCs) in air were defined. Simulation of the diffusion process following sudden sample introduction into the three-membrane inlet was also carried out. Experimental testing of the three-membrane inlet system with the cyclic sudden sample injection mode for benzene, toluene, styrene, and xylene in air was performed. The simulation and the experimental results demonstrated that, when this mode is used, the VOCs/nitrogen relative enrichment factor of samples introduced into the mass spectrometer equipped with a three-membrane inlet is increased by a factor of approximately 10(5) compared with a direct introduction method. This effect may be used to decrease detection limits of compounds obtained with mass spectrometry to decrease matrix flow through the inlet at the same detection limits.

Journal Article↗

Mass transfer in VOC adsorption on zeolite: experimental and theoretical breakthrough curves.

From experimental results of adsorption of volatile organic compounds (VOCs) on zeolite, we propose simulations of the breakthrough curves based on the Linear Driving Force model. Experiments were run on fixed beds of hydrophobic commercial zeolites. Pollutants chosen are from several chemical classes with different polarities. A good agreement between experimental and numerical results is found when an adjustable value of the internal mass-transfer coefficient is used. A constant value of effective diffusivity is found independent of the nature and the amount of VOCs adsorbed. A relation linking intrapellet mass-transfer coefficient and equilibrium constant is proposed, including the average effective diffusivity, to make predictions of breakthrough curves for any kind of volatile organic pollutant in gaseous effluents.

Adsorption↗

(M)VOC and composting facilities. Part 2: (M)VOC dispersal in the environment.

BACKGROUND, AIMS AND SCOPE: Composting facilities are known to release odorous volatiles due to biodegradation of municipal waste and plant residues. Although odour perception and its grading is influenced by experience, attitude and adaptation, these emissions have created a lack of acceptance for residents in the vicinity of composting facilities. Enclosure of compost pile halls, ventilation systems and biofilters are often insufficient to minimise the burden of compost-derived compounds in the air. Moreover, economic considerations forced smaller communities to establish less sophisticated facilities with open storage areas and other relevant sources for wind-borne dispersal of bioaerosols. Aim of the present study was to characterise the immission and dispersal of microbial volatiles (MVOC) and, besides, to find coincidences between MVOC and compost odour. METHODS: In the course of this study, the surroundings of two composting facilities, differing in their type of process engineering, were investigated for emission of volatiles in the environment. Both microbially and plant-derived substances were assessed, several of which have low odour thresholds. Air samples were taken in distances ranging from 50 to 800 m in a downwind direction from each facility. RESULTS AND DISCUSSION: Compost-derived and microbial volatile organic compounds (MVOC) were found at distances of up to 800 m from the composting facilities. Terpenes like alpha-pinene, camphene and camphor were the dominant compounds and coincided with typical compost odour, whereas several typical MVOC were not found at greater distances. The terpenes in combination with certain MVOC may play an important role in the perception of compost odour. Exposure concentrations were not of toxicological relevance, but sensory irritation and psychohygienic effects due to an annoyance potential of such compounds should not be dismissed. RECOMMENDATIONS AND OUTLOOK: Although terpenes are generally associated with pleasant odour characteristics, they seemed to contribute to malodours in a mixture with other VOC, in this context of volatile waste from compost facilities. Malodorous emissions from biowaste have to be considered as sources of health complaints and the investigation of mixtures of compost-derived volatiles is still inevitable. Exposure levels have to be discussed taking VOC mixtures into account. Within composting facilities, technical devices have to be improved to minimise dispersal of volatiles to prevent residents from immissions eventually causing health complaints.

Aerosols↗

Emission patterns and emission rates of MVOC and the possibility for predicting hidden mold damage?

UNLABELLED: Laboratory trials were performed in order to search for the variety of the production of microbial volatile organic compounds (MVOC), which could be used as indicators for hidden mold damage. Concerning MVOC production the experiments showed a dependency on the mold genus/species, the different strains used and the building materials used as substrate. It could be proved that the production of certain MVOC is not consistent at all times. On the whole low emission rates in terms of microg/h/m2 of the MVOC were found. Extrapolating the emissions rates from the laboratory trails to an indoor air situation results in concentrations below the analytical detection limit in most cases. According to these results only heavy or very large fungal contaminations might be detected by this method in indoor air. The studies were performed at the Institute of Hygiene and Environmental Medicine, Charite, Germany. PRACTICAL IMPLICATIONS: Microorganisms like bacteria and molds produce a huge variety of substances, and a part of them are released into the environment. Some compounds like, e.g. alcohols or ketones are volatile, therefore found in the air and called MVOC. Those compounds were considered helpful to track especially hidden mold damage. The study presented here showed, that the emission pattern varies from genus to genus and sometimes even from fungal strain to fungal strain. The results concerning the emission rates from different infested building materials proved, that the concentrations produced are much too low to be detected in indoor air, especially considering the dilution because of ventilation. Therefore, we conclude that MVOC should not be used as predictors for mold damage in indoor environments.

Air Microbiology↗

Relationship between environmental exposure to toluene, xylene and ethylbenzene and the expired breath concentrations for gasoline service workers.

This study evaluated the relationship between the breath concentrations of, and personal exposure to, toluene, xylene and ethylbenzene of thirty workers from ten gasoline stations. Personal exposure air samples and workplace samples were collected simultaneously. Each subject provided a sample of exhaled breath after his or her personal exposure air was sampled. Twenty-five personal air, 17 workplace and 30 breath samples were collected in this study. Results indicated that breath concentrations of toluene and xylene were significantly correlated with personal monitoring concentrations. Furthermore, multiple regression analysis showed that exhaled toluene levels were highly influenced by personal toluene concentrations and the amount of personal gasoline sold (r2 = 0.762), while exhaled xylene levels depended on wind speed and personal xylene exposure concentrations (r2 = 0.665). Exhaled ethylbenzene levels were too low to present a relationship between concentrations and personal exposure levels. The exhaled toluene, xylene and ethylbenzene concentrations ranged from 4.3 to 41.8, 0.9 to 13.9, and 0.2 to 6.5 ppb, and the corresponding personal monitoring concentrations ranged from 60.3 to 572.3, 16.4 to 156.6, and 10.7 to 136.6, respectively. The average number of symptoms per person, according to neurotoxic questionnaire 16 (abbreviated as Q16) was 4.1 and six workers showed over six symptoms in Q16. This study suggests that exhaled toluene and xylene levels are suitable for use as biological exposure indices even at the ppb-level of exposure. Gasoline service workers are exposed to high levels of volatile organic compounds (VOCs) and the potential threats to their neurological systems deserve further investigation.

Adult↗

Does Haber's law apply to human sensory irritation?

Irritation of the eyes, nose, and throat by airborne chemicals--also referred to as "sensory irritation"--is an important endpoint in both occupational and environmental toxicology. Modeling of human sensory irritation relies on knowledge of the physical chemistry of the compound(s) involved, as well as the exposure parameters (concentration and duration). A reciprocal relationship between these two exposure variables is postulated under Haber's law, implying that protracted, low-level exposures may be toxicologically equivalent to brief, high-level exposures. Although time is recognized as having an influence on sensory irritation, the quantitative predictions of Haber's Law have been addressed for only a handful of compounds in human experimental studies. We have conducted a systematic literature review that includes a semiquantitative comparison of psychophysical data extracted from controlled human exposure studies versus. the predictions of Haber's law. Studies containing relevant data involved exposures to ammonia (2), chlorine (2), formaldehyde (1), inorganic dusts such as calcium oxide (1), and the volatile organic compound 1-octene (1). With the exception of dust exposure, varying exposure concentration has a proportionally greater effect on sensory irritation than does changing exposure duration. For selected time windows, a more generalized power law model (c(n) x t = k) rather than Haber's law per se (c x t = k) yields reasonably robust predictions. Complicating this picture, however, is the frequent observation of intensity-time "plateauing," with time effects disappearing, or even reversing, after a relatively short period, depending on the test compound. The implications of these complex temporal dynamics for risk assessment and standard setting have been incompletely explored to date.

Alkenes↗

Simplified analysis of organic compounds in headspace and aqueous samples by high-capacity sample enrichment probe.

A sample enrichment probe (SEP) consisting of a thin rod of an inert material and provided at one end with a short sleeve of polydimethylsilicone rubber was used for the high-capacity sample enrichment of analytes from gaseous and aqueous samples for analysis by gas chromatography (GC) and its hyphenated techniques. The silicone rubber was exposed to the analytical sample, after which the end of the rod carrying the silicone rubber was introduced into the injector and the analytes thermally desorbed and analysed by GC. This technique is similar to, but differs from, solid-phase microextraction (SPME) in that a much larger volume of the sorptive phase is employed, the sorptive phase is not introduced into the inlet of the GC via a needle and the injector is opened to the atmosphere for the introduction and removal of the SEP. In the determination of volatile and semi-volatile organic compounds in gaseous and aqueous media, the SEP technique gave results comparable with those obtained by the stir-bar-sorptive extraction (SBSE) and high-capacity sorption probe (HCSP) techniques. Implementation of the SEP technique requires only minor adaptations to the gas chromatograph and does not require any auxiliary thermal desorption and cryotrapping equipment.

Chromatography, Gas↗

Dynamic headspace analyses of residual volatiles in pharmaceuticals.

Pharmaceutical preparations may be assayed for volatile organic compounds by purging them with a stream of inert carrier gas and collecting the organics onto a suitable sorbent material, from which they may be backflushed to a gas chromatograph. Compared to solvent extraction, the process offers advantages of increased sensitivity, ease of automation, and elimination of the solvent peak. Examples are given of three major sources of volatiles in pharmaceuticals, with the development of a method for quantitating the volatiles using an internal standard.

Benzene↗

Kinetics of catalytic oxidation of benzene, n-hexane, and emission gas from a refinery oil/water separator over a chromium oxide catalyst.

With the advances made in the past decade, catalytic incineration of volatile organic compounds (VOCs) has become the technology of choice in a wide range of pollution abatement strategies. In this study, a test was undertaken for the catalytic incineration, over a chromium oxide (Cr2O3) catalyst, of n-hexane, benzene, and an emission air/vapor mixture collected from an oil/water separator of a refinery. Reactions were carried out by controlling the feed stream to constant VOC concentrations and temperatures, in the ranges of 1300-14,700 mg/m3 and 240-400 degrees C, respectively. The destruction efficiency for each of the three VOCs as a function of influent gas temperature and empty bed gas residence time was obtained. Results indicate that n-hexane and the oil vapor with a composition of straight- and branch-chain aliphatic hydrocarbons exhibited similar catalytic incineration effects, while benzene required a higher incineration temperature or longer gas retention time to achieve comparable results. In the range of the VOC concentrations studied, at a given gas residence time, increasing the operating temperature of the catalyst bed increased the destruction efficiency. However, the much higher temperatures required for a destruction efficiency of over 99% may be not cost-effective and are not suggested. A first-order kinetics with respect to VOC concentration and an Arrhenius temperature dependence of the kinetic constant appeared to be an adequate representation for the catalytic oxidation of these volatile organics. Activation energy and kinetic constants were estimated for each of the VOCs. Low-temperature destruction of the target volatile organics could be achieved by using the Cr2O3 catalyst.

Air Pollutants, Occupational↗

Emission modelling and validation of VOCs' source strengths in air-conditioned office premises.

An emission model for indoor volatile organic compounds (VOCs) based on mass balance considerations has been presented and validated under steady state conditions. Comparison were made for the measured and predicted concentrations of 37 selected VOCs and TVOC through a case intervention study on the filters of the ventilation system in a new commercial air-conditioned office building. The intervention involved replacing media filters with electronic and carbon filtration. TVOC and 37 compounds selected for their health and comfort impact, representation of major chemical classes that occur in indoor air and their utility as markers of pollution sources were studied. The concentration levels predicted by the model were compared with actual measurements. Twenty-five target compounds and the TVOC were adequately described by the model where the measured concentrations were in agreement with the predicted concentrations. Modeling of the remaining 12 compounds was found to be affected by the emission rates that were occupant related.

Air Conditioning↗

External capillary condensation and adsorption of VOCs onto activated carbon fiber cloth and felt.

Adsorption isotherms of some volatile organic compounds (VOCs), present in air at concentrations ranging from 10 to 2500 mg m(-3), were performed onto activated carbon fiber cloth and felt. The VOCs loading air were isopropanol, toluene, acetone, methyl ethyl ketone, ethyl acetate and dichloromethane. Isotherm adsorption data were generated. These experimental values were modeled by the equation of Dubinin and co-workers and by the Langmuir relation. Model parameters are discussed as a function of adsorbent materials and VOC structure. Adsorption capacity was generally found higher for the cloth than for the felt. An effect of external capillary condensation onto the felt of compounds with high surface tension was demonstrated for VOC concentrations above 1500 mg m(-3).

Adsorption↗

Biofiltration of a mixture of volatile organic emissions.

Air biofiltration is now under active consideration for the removal of the volatile organic compounds (VOCs) from polluted airstreams. To optimize this emerging environmental technology and to understand compound removal mechanisms, a biofilter packed with peat was developed to treat a complex mixture of VOCs: oxygenated, aromatic, and chlorinated compounds. The removal efficiency of this process was high. The maximum elimination capacity (ECmax) obtained was approximately 120 g VOCs/m3 peat/hr. Referring to each of the mixture's components, the ECmax showed the limits in terms of biodegradability of VOCs, especially for the halogenated compounds and xylene. A stratification of biodegradation was observed in the reactor. The oxygenated compounds were metabolized before the aromatic and halogenated ones. Two assumptions are suggested. There was a competition between bacterial communities. Different communities colonized the peat-based biofilter, one specialized for the elimination of oxygenated compounds, the others more specialized for elimination of aromatic and halogenated compounds. There was also substrate competition. Bacterial communities were the same over the height of the column, but the more easily biodegradable compounds were used first for the microorganism metabolism when they were present in the gaseous effluent.

Air Pollutants↗

Sonolysis of an aqueous mixture of trichloroethylene and chlorobenzene.

The effect of the initial concentration on the ultrasonic degradation of two volatile organic compounds trichloroethylene (TCE) and chlorobenzene (CB) was investigated. At higher concentrations, slower sonolysis rates were obtained due to the lowering of the average specific heat ratio gamma of the gas inside the cavitation bubbles. Furthermore, the effect of different concentrations of CB on the sonolysis of 3.34 mM TCE and the effect of different concentrations of TCE on the sonolysis of 3.44 mM CB was examined. The presence of CB lowered the sonolysis rate of TCE, while the sonolysis rate of CB did not decrease by TCE addition. An even higher sonolysis rate was obtained for 3.44 mM CB in the presence of 0.84 mM TCE than without TCE. The explanation for the different effects of both volatile organics on each other's sonolysis rate is thought to be the difference in reaction rate of TCE and CB with the radicals formed during sonolysis. The effect of TCE on the sonolysis rate of CB by lowering the gamma value is compensated by an increased indirect degradation of CB by radicals formed out of TCE. The decreased thermal degradation and the increased indirect radical degradation of CB in the presence of TCE is demonstrated by determining the kinetics of the degradation products styrene and dichlorobenzene.

Journal Article↗

Measurement and modeling of single- and multi-component adsorption equilibria of VOC on high-silica zeolites.

From pure and binary gas adsorption equilibria measurements carried out using a volumetric method for three volatile organic compounds (methyl ethyl ketone, toluene (TOL), and 1,4-dioxane) on two high-silica zeolites, desaluminated faujasite Y (Fau Y) and ZSM-5 (Sil Z), co-adsorption was investigated and modeled. Apart from steric exclusion taking place with TOL-containing mixtures on Sil Z, micropore filling was similar to distillation since the component with the lower volatility adsorbed preferentially. At low coverage, chemisorption on specific sites happened in favor of polar or major compound, whereas at saturation the adsorbent was selective for the minor compound. Second, a quantitative prediction of binary equilibria was performed using the ideal adsorbed solution theory (IAST), examining the influence of pure component adsorption fitting model. The efficiency of correlations when extending AST to real mixture behavior was satisfactory in most cases. For engineering purposes, Fau Y is to be considered as a high-adsorption capacity adsorbent, whose selectivity can be described qualitatively by the distillation analogy and predicted quantitatively with the IAST in case of quasi-ideal mixtures.

Adsorption↗

Steam stripping of the unsaturated zone of contaminated sub-soils: the effect of diffusion/dispersion in the start-up phase.

The unsteady process of steam stripping of the unsaturated zone of soils contaminated with volatile organic compounds (VOCs) is addressed. A model is presented. It accounts for the effects of water and contaminants remaining in vapour phase, as well as diffusion and dispersion of contaminants in this phase. The model has two components. The first is a one-dimensional description of the propagation of a steam front in the start-up phase. This is based on Darcy's law and conservation laws of mass and energy. The second component describes the transport of volatile contaminants. Taking the view that non-equilibrium between liquid and vapour phases exists, it accounts for evaporation, transport, and condensation at the front. This leads to a moving-boundary problem. The moving-boundary problem is brought into a fixed domain by a suitable transformation of the governing partial differential equations, and solved numerically. For a broad range of the governing dimensionless numbers, such as the Henry, Merkel and Péclet numbers, computational results are discussed. A mathematical asymptotic analysis supports this discussion. The range of parameter values for which the model is valid is investigated. Diffusion and dispersion are shown to be of qualitative importance, but to have little quantitative effect in the start-up phase.

Diffusion↗

Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer.

Miniature gas chromatography (GC) and miniature mass spectrometry (MS) instrumentation has been developed to identify and quantify the chemical compounds present in complex mixtures of gases. The design approach utilizes micro-GC components coupled with a Paul quadrupole ion trap (QIT) mass spectrometer. Inherent to the system are high sensitivity, good dynamic range, good QIT resolution, low GC flow-rates to minimize vacuum requirements and the need for consumables; and the use of a modular approach to adapt to volatile organic compounds dissolved in water or present in sediment. Measurements are reported on system response to gaseous species at concentrations varying over four orders of magnitude. The ability of the system to deal with complicated mixtures is demonstrated, and future improvements are discussed. The GC/QIT system described herein has a mass, volume and power that are, conservatively, one-twentieth of those of commercial off-the-shelf systems. Potential applications are to spacecraft cabin-air monitoring, robotic planetary exploration and trace-species detection for residual gas analysis and environmental monitoring.

Complex Mixtures↗