PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Robotics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Complex behavior by means of dynamical systems for an anthropomorphic robot.

We present an architecture to generate behavior for an anthropomorphic robot. The goal is to equip the robot with the capacity to interact with a human. Motivated by the research on biological systems, our basic assumption is that the behavior to perform determines the external and internal structure of the behaving system. We describe the anthropomorphic design of our robot and present a distributed control system that generates human-like navigation and manipulation behavior. As the mathematical framework for this purpose we have developed a control system which is entirely based on dynamical systems in the form of instantiated dynamics and neural fields. We also present a dynamic scheme for the behavioral organization based on competitive dynamics.

Journal Article↗

Synthesis of autonomous robots through evolution.

Evolutionary robotics is the attempt to develop robots through a self-organized process based on artificial evolution. This approach stresses the importance of the study of systems that have a body and that are situated in a physical environment, and which autonomously develop their own skills in close interaction with the environment. In this review we briefly illustrate the method and the main concept of evolutionary robotics, and examine the most significant contribution in this area. We also discuss some of the contributions that this research area is making to the foundational debate in cognitive science.

Journal Article↗

Robotic devices in surgery.

Robotic devices are defined wich can be used as an aid to surgery. A classification system is proposed that reflects the manner of use and the safety of the systems. Typical benefits and problems of using robots are discussed, and a number of applications are reviewed. These cover "autonomous" systems, that involve no intervention from the surgeon; "hands-on" systems, that require the direct involvement of the surgeon; and "Master/Slave" (or Telemanipulator) systems, that are somewhere between these two and involve some degree of indirect surgeon activity. A number of predictions for the future of medical robotics are provided.

Journal Article↗

The robotic mouse: unravelling the function of AF4 in the cerebellum.

The devastating nature and lack of effective treatments associated with neurodegenerative diseases have stimulated a world-wide search for the elucidation of their molecular basis to which mouse models have made a major contribution. In combination with transgenic and knockout technologies, large-scale mouse mutagenesis is a powerful approach for the identification of new genes and associated signalling pathways controlling neuronal cell death and survival. Here we review the characterization of the robotic mouse, a novel model of autosomal dominant cerebellar ataxia isolated from an ENU-mutagenesis programme, which develops adult-onset region-specific Purkinje cell loss and cataracts, and displays defects in early T-cell maturation and general growth retardation. The mutated protein, Af4, is a member of the AF4/LAF4/FMR2 (ALF) family of putative transcription factors previously implicated in childhood leukaemia and FRAXE mental retardation. The mutation, which lies in a highly conserved region among the ALF family members, significantly reduces the binding affinity of Af4 to the E3 ubiquitin-ligase Siah-1a, isolated with Siah-2 as interacting proteins in the brain. This leads to a markedly slower turnover of mutant Af4 by the ubiquitin-proteasome pathway and consequently to its abnormal accumulation in the robotic mouse. Importantly, the conservation of the Siah-binding domain of Af4 in all other family members reveals that Siah-mediated proteasomal degradation is a common regulatory mechanism that controls the levels, and thereby the function, of the ALF family. The robotic mouse represents a unique model in which to study the newly revealed role of Af4 in the maintenance of vital functions of Purkinje cells in the cerebellum and further the understanding of its implication in lymphopoeisis.

Amino Acid Sequence↗

Robotic synthesis of 6-[18F]fluoro-L-dopa.

The aim of this study was to develop a method of semi-automated 6-[18F]fluoro-L-dopa (6-[18F]FDOPA) synthesis using a robotic system (Scanditronix Anatech RB III, Uppsala, Sweden). [18F]Fluorine was produced via 20Ne(d,alpha)18F using a Scanditronix MC17F cyclotron (Uppsala). The radiosynthesis was performed by the Scanditronix Anatech RB III robotic system. On average, a typical run produced 16-19 mCi of 6-[18F]FDOPA at end of synthesis (EOS) after 2 h irradiation of the F2/neon gas target. The total synthesis time was 110 min. The retention time of 6-[18F]FDOPA (the radio peak) was 8.2 min, which was consistent with the 6-[19F]FDOPA ultraviolet peak. The radiochemical purity was greater than 97%. A robotic, semi-automated method for 6-[18F]FDOPA radiosynthesis is therefore feasible. The radiation burden for the operator can be reduced as much as possible. Sufficient activity of 6-[18F]FDOPA could be obtained for positron emission tomography studies of dopaminergic function.

Dihydroxyphenylalanine↗

Design and control of an IPMC wormlike robot.

This paper presents an innovative wormlike robot controlled by cellular neural networks (CNNs) and made of an ionic polymer-metal composite (IPMC) self-actuated skeleton. The IPMC actuators, from which it is made of, are new materials that behave similarly to biological muscles. The idea that inspired the work is the possibility of using IPMCs to design autonomous moving structures. CNNs have already demonstrated their powerfulness as new structures for bio-inspired locomotion generation and control. The control scheme for the proposed IPMC moving structure is based on CNNs. The wormlike robot is totally made of IPMCs, and each actuator has to carry its own weight. All the actuators are connected together without using any other additional part, thereby constituting the robot structure itself. Worm locomotion is performed by bending the actuators sequentially from "tail" to "head," imitating the traveling wave observed in real-world undulatory locomotion. The activation signals are generated by a CNN. In the authors' opinion, the proposed strategy represents a promising solution in the field of autonomous and light structures that are capable of reconfiguring and moving in line with spatial-temporal dynamics generated by CNNs.

Animals↗

Semiautomatic and robotic methods for determining serum haptoglobin levels.

The assay of Makimura and Suzuki for serum haptoglobin has been adapted to use one tube with both semiautomated and robotic methods. The adaptation permits the determination of haptoglobin in several hundred serum samples per day. Both methods were strongly correlated with the original two-tube method and had within-assay variability of 4.4% for the semiautomated and 4.8% for the robotic method. Day-to-day variability averaged 6.0% for the semiautomated and 5.5% for the robotic method. The y-intercepts for both assays were higher than that of the original two-tube method, and thus, reference values are higher than those reported previously.

Journal Article↗

Performance of the MagNA pure LC robot for extraction of Chlamydia trachomatis and Neisseria gonorrhoeae DNA from urine and swab specimens.

DNA from uncentrifuged urines (n = 195 and n = 202) and cervical swabs (n = 221 and n = 601) was extracted by the MagNA Pure LC robot and the Amplicor method to validate the robot's extraction for Chlamydia trachomatis and Neisseria gonorrhoeae testing by Roche PCR. The robot provided a highly sensitive and specific method of DNA extraction.

Bacteriuria↗

Stacker Modules Used in a High-Capacity Robotics System for High Throughput Screening Compound Replication.

High throughput screening is now established as a key component of the pharmaceutical lead identification process in many pharmaceutical companies. Over recent years, thanks to advances in assay technology, process automation, and logistics control, the throughput capacity of HTS groups has increased significantly. It is now entirely possible to screen corporate compound collections against an individual pharmacological target within a timescale of several weeks. Despite these improvements, many HTS groups find that their capacity is limited by the rate at which they can provide test compounds in a "screen-ready" format. This limitation is usually imposed by the capacity and productivity of the single-armed robotic systems utilized. We have recently constructed a robotic system aimed at overcoming this particular problem. This system uses purpose-built microplate stacker units that provide high-capacity microplate storage and, importantly, provide an easy and fast interface between the robotic system and the human operators. This paper describes this automation project and the benefits that have resulted from its deployment.

Journal Article↗

Secondary prevention of allergic symptoms in a dairy farmer by use of a milking robot.

BACKGROUND: Animal-derived allergens include lipocalins which play an increasing role in occupational respiratory sensitizations. The prevention of sensitization in stock farming is often difficult due to intense exposure, with traditional milking still requiring close animal contact. Complete avoidance of allergen exposure is only possible if stock farming is abandoned. This is, however, often not feasible in small dairy plants because of the resulting loss of income. CASE PRESENTATION: In a 37-year-old female farmer daily asthmatic complaints appeared, associated with cow dust-derived allergen exposure by milking with a conventional device. Respiratory symptoms increased during a period of 12 years. Allergic bronchial asthma was diagnosed, caused by sensitization against cow dust-derived allergens, as demonstrated by positive skin prick test and by detection of IgE antibodies. In a separate specific inhalation challenge test using a 10% extract of cow dust-derived allergens a 330% increase of airway resistance was detected. To enable further dairy farming, a milking robot was installed in 1999, i.e., an automatic milking system. The novel milking technique reduced the daily exposure from over 2 hours to approximately 10 min. The clinical course after the installation of the milking robot was favourable, with less frequent allergic and asthmatic symptoms. Furthermore, asthma medication could be reduced. Improvement was noted also in terms of lung-function and decreased total serum IgE. CONCLUSION: The case presented and the evidence from the literature indicates that the strategy of exposure minimization to allergens at workplaces can be an effective alternative to total elimination. In farmers with cow dust allergy a milking robot is an appropriate technical measure to minimize allergen-exposure.

Journal Article↗

Dynamic robotic telepathology: a preliminary evaluation on frozen sections, histology and cytology.

We evaluated the diagnostic efficacy of a dynamic robotic telepathology system for the delivery of pathology services to distant hospitals. The system provided static/dynamic features and the remote control of a robotic microscope using four ISDN lines. For evaluation purposes, 184 consecutive cases were diagnosed at distance using the system. The cases were 60 frozen sections, 64 cases of gastrointestinal pathology and 60 cases of urinary cytology. The telemedicine diagnoses obtained in this way were compared with traditional microscopic diagnosis. Diagnostic agreement ranged from 90% in urinary cytology to 100% in frozen sections. The results suggest that a dynamic robotic telepathology system can be a useful tool for supporting the pathology practice of isolated hospitals.

Evaluation Studies as Topic↗

Graph rigidity and localization of multi-robot formations.

This paper provides theoretical foundation for the problem of localization in multi-robot formations. Sufficient and necessary conditions for completely localizing a formation of mobile robots/vehicles in SE(2) based on distributed sensor networks and graph rigidity are proposed. A method for estimating the quality of localizations via a linearized weighted least-squares algorithm is presented, which considers incomplete and noisy sensory information. The approach in this paper had been implemented in a multi-robot system of five car-like robots equipped with omni-directional cameras and IEEE 802.11b wireless network.

Journal Article↗

Image-guided robotic radiosurgery

PURPOSE: To describe the design and performance of a novel frameless system for radiosurgery. This technology, called image-guided radiosurgery (IGR), eliminates the need for stereotactic frame fixation by relating the identified lesion to radiographic landmarks. CONCEPT: IGR uses a lightweight x-band linear accelerator, computer-controlled robotic arm (Fanuc manipulator [Fanuc Robotics North America, Inc., Rochester Hills, MI]), paired orthogonal x-ray imagers, and a computer workstation that performs rapid image-to-image registration. During radiosurgery, the x-ray imaging system determines the location of the lesion and communicates these coordinates to the robot, which adjusts the pointing of the linear accelerator beam to maintain alignment with the target. RATIONALE: Existing stereotactic techniques require rigid cranial fixation to establish and maintain a system of reference for targeting. Such frames cause pain for the patient, limit the use of fractionation, and necessitate a prolonged period of general anesthesia if children are to be treated. Furthermore, skeletal or any other type of rigid fixation is difficult to achieve beyond the cranium. IGR was designed to overcome these limitations, which are inherent to nearly all current radiosurgical methods. DISCUSSION: Preliminary testing and early clinical experience have demonstrated the practicality and potential of the IGR concept and have identified the most important directions for improvement. For example, an IGR prototype accurately tracked target displacements in three dimensions but showed reduced accuracy when confronted by rotational movements. This observation led to development of a new generation of tracking algorithm that promises to improve tracking in all six dimensions. Further experience indicated that improvements in the quality of the x-ray images were needed to allow the system to locate and treat target sites outside the cranium. Consequently, a new x-ray imaging technology with superior resolution and increased sensitivity has been added to the system. These improvements should make it possible to apply IGR techniques to a variety of targets located throughout the body. This article describes and critiques the components of the IGR and summarizes our preliminary clinical experience.

Journal Article↗

Prototype application of a robot in the clinical laboratory enabling fully automated quantification of fecal porphyrins.

Unpleasant specimens, sensitive analytes, and a lengthy chromatographic procedure were the main reasons we implemented fecal porphyrin analysis with a laboratory robot. We describe the system in detail and compare it with the same technique performed manually. The day-to-day variation of assays of standards was lower with the robot than with the manual operation: 8% (CV) for coproporphyrin I and 11% for protoporphyrin IX. We repeatedly analyzed a specimen from a healthy volunteer and determined that the specimen contained (in nmol/g dry wt) 7.1 (SD 0.7) for coproporphyrin I, 3.0 (SD 0.4) for coproporphyrin III, and 44.4 (SD 4.3) for protoporphyrin IX. Upper reference limits as measured in 20 healthy volunteers were 20 nmol/g dry wt for coproporphyrin I, 12 nmol/g for coproporphyrin III, and 80 nmol/g for protoporphyrin IX. We also present characteristic chromatograms for samples from various different porphyrias that exhibit abnormal fecal porphyrin excretion. Calculations of return on investment show that the robot, working at full capacity, is a profitable tool.

Autoanalysis↗

[Mental load of robot operation upon workers].

In recent years industrial robots have been widely used in factories. In various stages of their introduction mental stress on workers is predicted and factory workers and managers are being forced to deal with the problem seriously. This study centers upon the operation of taking and giving parts between men and robots to estimate the physical and mental load on workers through the analysis of behaviors by means of such physiological indices as RMR, GSR, EOG, etc. and Video Tapes. At the same time I examined the relation of the level of consciousness with the change of the time of selection responses and psychological quantity such as working senses. I also referred to observations and researches in the field of mental medicine. As compared with conveyer system work, robot operation gives a greater mental influence for better or worse, so a more careful operation control is needed from the viewpoint of labor hygiene.

Adult↗

Early clinical evaluation of a robot arm/worktable system for spinal-cord-injured persons.

In Part I, "Developmental Case Study", this evaluation traces anecdotally the increasing application of microcomputer technology in a research program examining the uses of a robot arm in the rehabilitation of the high-spinal-cord-injured person. This program, supported by the Veterans Administration since 1974, built upon still earlier VA-supported work at Johns Hopkins on powered upper-limb prostheses. The Johns Hopkins University powered shoulder prosthesis served as the basis for the Robotic Arm/Worktable System, whose evolution is described in applications ranging from handling simple reading materials to self-feeding and the operation of a personal computer, all under the user's control through the same chin control interface employed for the control of the user's power wheelchair. Part II of this report focuses on the results of clinical evaluation in the development of the system. In the early stages of development, evaluation was provided by four subjects who used the system regularly for periods ranging from 4 months to a year. A later stage of evaluation featured a total of 16 subjects located in two VA Medical Centers, using the system for periods of from a few days to 4 months in duration. The VA's new Rehab R&D Evaluation Unit has begun an intensive evaluation process based upon 25 of the Robotic Arm/Worktable Systems currently on order.

Adult↗

The Effect of Robot-Assisted Gait Training on Balance, Gait and Kinesiophobia in Individuals With Post-Stroke Hemiparesis: A Randomized Controlled Trial.

BACKGROUND AND PURPOSE: Robot-assisted gait training (RAGT) is well established for post-stroke gait rehabilitation, but its potential effects on psychological and behavioral outcomes are less clear. This study investigated the effects of adding RAGT to conventional rehabilitation on balance, gait, kinesiophobia, and movement confidence in individuals with post-stroke hemiparesis. METHODS: This single-blind, parallel-group randomized controlled trial included 60 individuals with post-stroke hemiparesis (50-75&#xa0;years), randomly allocated to an RAGT group (n&#xa0;=&#xa0;30) or control group (n&#xa0;=&#xa0;30). Ethical approval was obtained from the Clinical Research Ethics Committee of Istanbul Yeni Y&#xfc;zy&#x131;l University (Approval No. 20.01.2022/05; approval date: 20 January 2022). Both groups received conventional rehabilitation for 8&#xa0;weeks; the RAGT group additionally received 24 sessions of RAGT. Kinesiophobia was a prespecified study outcome assessed using the Kinesiophobia Causes Scale (KCS); balance, gait, and balance confidence were also assessed. All 60 randomized participants completed follow-up and were analyzed in their assigned groups. RESULTS: Significant group&#xa0;&#xd7;&#xa0;time interactions were observed for several outcomes, including BBS, TUG duration, 10MWT walking speed, ABC, and KCS total score (p&#xa0;<&#xa0;0.05). The between-group difference in change for KCS total score was -0.36 (95% CI: -0.51 to -0.21; partial eta squared&#xa0;=&#xa0;0.292). In post hoc analyses adjusting each outcome for its baseline value, significant group effects remained for BBS, TUG duration, 10MWT walking speed, ABC, KCS biological domain, and KCS total score (p< = 0.031), whereas 10MWT step count and the KCS psychological domain were no longer statistically significant. DISCUSSION: Adding RAGT to conventional rehabilitation was associated with greater improvements in several balance, mobility, walking-speed, balance-confidence, and kinesiophobia outcomes compared with conventional rehabilitation alone. These findings suggest potential additional physical and psychological benefits of incorporating RAGT into post-stroke rehabilitation. However, because the RAGT group received greater overall treatment exposure, the observed between-group differences cannot be attributed solely to the robotic component. The principal contribution of this study is the concurrent evaluation of kinesiophobia and movement confidence alongside physical outcomes.

Aged↗

Transabdominal lumbar approach (TALA) versus retroperitoneal approach for robot-assisted renal surgery: a prospective randomised controlled trial.

PURPOSE: Common robotic nephrectomy approaches access the kidney via transperitoneal (TP) or retroperitoneal (RP) routes, each with distinct trade-offs. We developed the transabdominal lumbar approach (TALA), combining advantages of both accesses with improved visualisation and strategic trocar placement, and compared it with conventional RP in a prospective randomised controlled trial using technique-oriented intraoperative endpoints. METHODS: In this single-centre, prospective, open-label RCT, 40 patients were randomised to TALA (n&#x2009;=&#x2009;18) or conventional RP (n&#x2009;=&#x2009;22). Eligible patients were &#x2265;&#x2009;18 years with a renal tumour or non-functional kidney requiring robot-assisted total or partial nephrectomy. Exclusions included prior surgery on the affected kidney, renal vein tumour thrombus, and pregnancy. Both groups were followed for 30 days. The primary endpoint was time from first skin incision to renal artery identification. RESULTS: TALA achieved a median time saving of 16&#xa0;min compared to conventional RP (38 vs. 54&#xa0;min, p&#x2009;=&#x2009;0.001). Perioperative safety was comparable between groups, with three patients (7.5%) experiencing Clavien-Dindo grade III-IV complications. CONCLUSIONS: TALA met its primary endpoint with a significantly shorter time to renal artery identification than conventional RP access, and improving perceived surgical exposure and instrument handling.

Humans↗