Electrochemical biosensors: towards point-of-care cancer diagnostics.

Wide-scale point-of-care diagnostic systems hold great promise for early detection of cancer at a curable stage of the disease. This review discusses the prospects and challenges of electrochemical biosensors for next-generation cancer diagnostics. Electrochemical biosensors have played an important significant role in the transition towards point-of-care diagnostic devices. Such electrical devices are extremely useful for delivering the diagnostic information in a fast, simple, and low cost fashion in connection to compact (hand-held) analyzers. Modern electrochemical bioaffinity sensors, such as DNA- or immunosensors, offer remarkable sensitivity essential for early cancer detection. The coupling of electrochemical devices with nanoscale materials offers a unique multiplexing capability for simultaneous measurements of multiple cancer markers. The attractive properties of electrochemical devices are extremely promising for improving the efficiency of cancer diagnostics and therapy monitoring. With further development and resources, such portable devices are expected to speed up the diagnosis of cancer, making analytical results available at patient bedside or physician office within few minutes.

Biomarkers, Tumor↗

A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane.

This paper describes the preparation method as well as the in vitro and in vivo evaluation of a novel flexible glucose biosensor designed for long-term subcutaneous implantation. An epoxy-enhanced polyurethane membrane, which includes ca. 30-40% epoxy resin adhesive and 50-70% polyurethane, has been developed and used for the first time as the outer protective membrane of the sensor. This new membrane was developed to increase the in vivo durability and lifetime of implantable biosensors. This epoxy-polyurethane membrane was shown to be porous and is of excellent durability. A sensor with such a membrane shows excellent long-term stability and can last for 4-8 months in solutions at room temperature. To verify the in vivo performance of the sensor, nine sensors were implanted in three rats and tested regularly. Eight sensors kept functioning well in the rats for 10-56 days. The ninth sensor was damaged during implantation. All original sensitivity data as well as four response curves obtained at days 7, 17, 52 and 56, respectively are presented.

Animals↗

Multiplexed measurement of serum antibodies using an array biosensor.

The array biosensor provides the capability for simultaneously measuring titers of antibody against multiple antigens. Human antibodies against four different targets, tetanus toxin, diphtheria toxin, staphylococcal enterotoxin B (SEB) and hepatitis B, were measured simultaneously in sera from eight different donors in a single assay and titers were determined. The assays could measure amounts of bound antibody as low as approximately 100 fg. Each individual serum exhibited a different pattern of reactivity against the four target antigens. Applications of this biosensor capability include monitoring for exposure to pathogens and for efficacy of vaccination.

Animals↗

Design of molecular wires based on supramolecular structures for application in glucose biosensors.

In the present work, the synthesis and the spectroelectrochemical characterization of a novel iron compound derived of tetra-2-pyridyl-1,4-pyrazine (TPPZ) with hexacyanoferrate species forming a very stable supramolecular complex in the presence of polypyrrole (PPY) matrix, is described. The hybrid material has shown excellent catalytic activity towards H(2)O(2) detection that makes it suitable for being used as redox mediator in a glucose biosensor. The hybrid FeTPPZFeCN/PPY film presents satisfactory detection limits and high sensitivity for H(2)O(2) in the presence of K(+) or Na(+) ions. For the glucose biosensor, a linear range up to 1.1 mmoll(-1) of glucose was observed with no interferences. In this case, the sensitivities obtained were 7.88 and 5.90 microAmmol(-1)lcm(-2) in phosphate buffer or NaCl solutions, respectively. The good sensitivity is related to the presence of a high-dimensional structure based on polypyridine type ligands providing an "electron antennae effect" facilitating electron tunneling between the protein and the electrode.

Biosensing Techniques↗

Measurement of dimensions of pentagonal doughnut-shaped C-reactive protein using an atomic force microscope and a dual polarisation interferometric biosensor.

In order to develop the C-reactive protein (CRP) sensor chips for clinical detection of atherosclerosis and coronary heart disease, we used an atomic force microscope (AFM) and a dual polarization interferometric (DPI) biosensor to probe the surface ultrastructure and to measure the dimensions of CRP. A single pentagonal structure was directly visualized by AFM, and quantitative measurements of the dimensions of the protein were provided. The average height calculated for each pentagonal CRP particle was approximately 3.03+/-0.37 nm, which basically corresponds to that (36 A in protomer diameter) previously obtained from the structure of CRP determined by X-ray crystallography. Moreover, a experiment using dual polarization interferometric (DPI) as a biosensor was then performed, and the average monolayer thickness value (3.18+/-0.43 nm) that was calculated basically corresponds to that obtained from the experimental value (3.03+/-0.37 nm) of the height measured by an AFM method for CRP. Further investigations will be performed to study the surface ultrastructure of a single pentagonal CRP molecule, and for this purpose a CRP sample (at low concentration) was scanned in vacuum by AFM. The higher-resolution images clearly revealed the presence of doughnut-shaped CRP molecules. In addition, phase images of CRP molecules were captured simultaneously with their height images, and the lateral dimensions of the doughnut-shaped CRP molecules were then measured. It was found that the average values calculated for the outer diameter (11.13+/-1.47 nm) and pore diameter (3.52+/-0.42 nm) are respectively close to those (102 A in outer diameter and 30 A in pore diameter) previously obtained from the structure of CRP determined by X-ray crystallography. This study represents the first direct characterization of the surface ultrastructure and dimensional measurement of the CRP molecule on the sensor chip.

Biosensing Techniques↗

A sequential injection analysis/chemiluminescent plant tissue-based biosensor system for the determination of diamine.

In this paper, a new chemiluminescent plant tissue-based biosensor for diamine detection was presented by employing sequential injection analysis (SIA), which facilitates precise fluidic handling and lower consumption of sample and reagents. Pea-seedling tissue acted as the molecular recognition element and was packed in a mini-PTFE column and further incorporated in the SIA system. The analysis of diamines, such as putrescine and cadaverine, is based on an enzymatic conversion which takes place in the plant tissue column to produce hydrogen peroxide. The formed hydrogen peroxide was detected by a chemiluminescence reaction involving luminol and Co(2+). Under the optimal conditions, the linear calibration graphs were obtained within 0.2-80 microM (putrescine) and 0.5-100 microM (cadaverine). The detection limits of 0.03 and 0.06 microM were achieved for putrescine and cadaverine, respectively, along with the relative standard deviations of 2.14% and 3.08% (n=11) and a sampling frequency of 40 h(-1). The present biosensor has been used for the analysis of diamine in fish samples with an acceptable accuracy.

Biological Assay↗

A probe for NADH and H2O2 amperometric detection at low applied potential for oxidase and dehydrogenase based biosensor applications.

Modified screen-printed electrodes for amperometric detection of H(2)O(2) and nicotinamide adenine dinucleotide (NADH) at low applied potential are presented in this paper. The sensors are obtained by modifying the working electrode surface with Prussian Blue, a well known electrochemical mediator for H(2)O(2) reduction. The coupling of this sensor with phenazine methosulfate (PMS) in the working solution gives the possibility of measuring both NAD(P)H and H(2)O(2). PMS reacts with NADH producing PMSH, which in the presence of oxygen, gives an equimolar amount of H(2)O(2). This allows the measurement of both analytes with similar sensitivity (357 mA mol(-1)L cm(-2) for H(2)O(2) and 336 mA mol(-1)L cm(-2) for NADH) and LOD (5x10(-7)mol L(-1) for H(2)O(2) and NADH) and opens the possibility of a whole series of biosensor applications. In this paper, results obtained with a variety of dehydrogenase enzymes (alcohol, malic, lactate, glucose, glycerol and glutamate) for the detection of enzymatic substrates or enzymatic activity are presented demonstrating the suitability of the proposed method for future biosensor applications.

Biosensing Techniques↗

Embryonic stem cells as a novel cell source of cell-based biosensors.

To investigate the use of embryonic stem cells as biosensor elements, mouse embryoid bodies were cultured on the surface of the light-addressable potentiometric sensor and induce to in vitro differentiate into cardiomyocytes and neurons. Extracellular potentials of the cells were recorded by sensor, to detect stem cells potential applications in drugs screening. The experimental results show that known cardiac stimulants (isoproterenol) and relaxants (carbamylcholine) have characteristic effects on the cardiomyocytes in terms of the changes of beat frequency, amplitude and duration. Thus, the embryonic stem cells potentially represent a renewable cell source for the cell-based biosensors.

Action Potentials↗

Comparison of amperometric biosensors fabricated by palladium sputtering, palladium electrodeposition and Nafion/carbon nanotube casting on screen-printed carbon electrodes.

Different strategies, including palladium electrodeposition (Pd(CV)), Pd sputtering (Pd(S)) and Nafion-solubilized carbon nanotube casting (Nafion/CNT), were used to modify screen-printed carbon electrodes (SPCEs) for the fabrication of amperometric enzyme biosensors. The electrochemical properties of the bare and modified SPCEs and the optimal conditions for surface modification were determined. The electrochemical response of the bare SPCE to H(2)O(2) under the potential of 0.3 V could be improved about 100-fold by Pd modification by electrodeposition or sputtering. By contrast, the electrochemical response of the bare SPCE was enhanced by only about 11-fold by Nafion/CNT casting. Moreover, the Pd(CV)-SPCEs exhibited better reproducibility of electrochemical response (a relative standard deviation (R.S.D.)<6.0%) than freshly prepared Pd(S)-SPCEs (R.S.D.>10%). The glucose biosensor fabricated from Pd-modified electrodes could be stored for up to 108 days without loosing significant activity. The Pd(CV)-SPCE also showed very reliable signal characteristics upon 50 consecutively repeated measurements of ascorbic acid. The electrocatalytic detection of the Pd-SPCE was combined with additional advantages of resistance to surface fouling and hence good stability. In conclusion, this study demonstrated that deposition of Pd thin film on SPCEs by electrodeposition or sputtering provided superior enhancement of electrochemical properties compared to Nafion/CNT-SPCEs. Despite their high electrochemical response, Pd(S)-SPCEs required an activation process to improve stability and Pd(CV)-SPCEs suffered from poor between electrode reproducibility.

Biosensing Techniques↗

Phage as a molecular recognition element in biosensors immobilized by physical adsorption.

Biosensors based on landscape phages immobilized by physical adsorption on the surface of a quartz crystal microbalance was used for detection of beta-galactosidase from Escherichia coli. The sensor had a detection limit of a few nanomoles and a response time of a approximately 100 s over the range of 0.003-210 nM. The binding dose-response curve had a typical sigmoid shape and the signal was saturated at the beta-galactosidase concentration of about 200 nM. A marked selectivity for beta-galactosidase over BSA was observed in mixed solutions even when the concentration of BSA exceeded the concentration of beta-galactosidase by a factor of approximately 2000. The apparent value of the dissociation constant (K(d)) of the interaction of free phage with beta-galactosidase (9.1+/-0.9 pM) was smaller compared with the one calculated for the bound phage (1.7+/-0.5 nM). The binding was specific with three binding sites needed to bind a single molecule of beta-galactosidase. The K(d) obtained from the enzyme-linked immunosorbent assay (ELISA) for the phage and the monoclonal anti-beta-galactosidase antibodies were 21+/-2 and 26+/-2 nM, respectively. Although the method of physical adsorption is simpler and more economical in comparison with Langmuir-Blodgett and molecular assembling methods the performances of the sensors made by these technologies compare well. This work provides evidence that phage can be used as a recognition element in biosensors using physical adsorption method for immobilization of phage on the sensor surface.

Adsorption↗

A novel alcohol dehydrogenase biosensor based on solid-state electrogenerated chemiluminescence by assembling dehydrogenase to Ru(bpy)(3)2+-Au nanoparticles aggregates.

Based on electrogenerated chemiluminescence (ECL), a novel method for fabrication of alcohol dehydrogenase (ADH) biosensor by self-assembling ADH to Ru(bpy)(3)(2+)-AuNPs aggregates (Ru-AuNPs) on indium tin oxide (ITO) electrode surface has been developed. Positively charged Ru(bpy)(3)(2+) could be immobilized stably on the electrode surface with negatively charged AuNPs in the form of aggregate via electrostatic interaction. On the other hand, AuNPs are favourable candidates for the immobilization of enzymes because amine groups and cysteine residues in the enzymes are known to bind strongly with AuNPs. Moreover, AuNPs can act as tiny conduction centers to facilitate the transfer of electrons. Such biosensor combined enzymatic selectivity with the sensitivity of ECL detection for quantification of enzyme substrate, and it displayed wide linear range, high sensitivity and good stability.

Alcohol Dehydrogenase↗

Surface plasmon resonance biosensor for direct detection of antibody against Epstein-Barr virus.

This paper describes the direct label-free detection of antibodies against the Epstein-Barr virus (anti-EBNA) using a surface plasmon resonance (SPR) biosensor. The antibody detection was performed using the immunoreaction between anti-EBNA and a respective synthetic peptide (EBNA-1), which was conjugated with bovine serum albumin (BSA-EBNA) and immobilized on the sensor surface. Three immobilization chemistries for the attachment of BSA-EBNA were investigated to optimize ligand density and minimize loss of EBNA-1 immunoreactivity. The developed SPR biosensor functionalized with the optimal immobilization method was calibrated and characterized in terms of detection limit, reproducibility, regenerability and storability. It was demonstrated that the sensor is capable of detecting concentrations of anti-EBNA as low as 0.2 ng/ml (approximately 1 pM) both in buffer and 1% human serum and can be stored and regenerated for repeated use.

Antibodies↗

Determination of organophosphorous pesticides by a novel biosensor based on localized surface plasmon resonance.

Liquid and gas chromatography are commonly used to measure organophosphorus pesticides. However, these methods are relatively time consuming and require a tedious sample pretreatment. Here, we applied the localized surface plasmon resonance (LSPR) of gold nanoparticles covalently coupled with acetylcholinesterase (AChE) to create a biosensor for detecting an example of serial signals responding to paraoxon in the range of 1-100 ppb by an AChE modified LSPR sensor immersing in a 0.05 mM ACh solution. The underlying mechanism is that paraoxon prevents acetylcholine chloride (ACh) reacting with AChE by destroying the OH bond of serine in AChE. We found that the AChE modified LSPR sensors prepared by incubation with 12.5 mU/mL of AChE in phosphate buffer solution at pH 8.5 room temperature for 14 h have the best linear inhibition response with a 0.234 ppb limit of paraoxon detection. A 14% of inhibition on the sensor corresponds to the change of paraoxon concentration from 1 to 100 ppb. The sensor remained 94% of its original activity after six cycles of inhibition with 500 ppb paraoxon followed with reactivation of AChE by 0.5 mM 2-pyriding-aldoxime methoiodide (2-PAM). In addition, the sensor retains activity and gives reproducible results after storage in dry state at 4 degrees C for 60 days. In conclusion, we demonstrated that the AChE modified LSPR sensors can be used to determine the concentration of paraoxon biosensor with high sensitive and stable characteristics.

Acetylcholinesterase↗

Oxygen tolerance of an implantable polymer/enzyme composite glutamate biosensor displaying polycation-enhanced substrate sensitivity.

Biosensors were fabricated at neutral pH by sequentially depositing the polycation polyethyleneimine (PEI), the stereoselective enzyme L-glutamate oxidase (GluOx) and the permselective barrier poly-ortho-phenylenediamine (PPD) onto 125-microm diameter Pt wire electrodes (Pt/PEI/GluOx/PPD). These devices were calibrated amperometrically at 0.7 V versus SCE to determine the Michaelis-Menten parameters for enzyme substrate, l-glutamate (Glu) and co-substrate, dioxygen. The presence of PEI produced a 10-fold enhancement in the detection limit for Glu (approximately 20 nM) compared with the corresponding PEI-free configurations (Pt/GluOx/PPD), without undermining their fast response time (approximately 2 s). Most remarkable was the finding that, although some designs of PEI-containing biosensors showed a 10-fold increase in linear region sensitivity to Glu, their oxygen dependence remained low.

Amino Acid Oxidoreductases↗

A magnetoelastic resonance biosensor immobilized with polyclonal antibody for the detection of Salmonella typhimurium.

Mass-sensitive, magnetoelastic resonance sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted by the sensor in response to an applied, time varying, magnetic field. This magnetostrictive platform has a unique advantage over conventional sensor platforms in that measurement is wireless and remote. A biosensor for the detection of Salmonella typhimurium was constructed by immobilizing a polyclonal antibody (the bio-molecular recognition element) onto the surface of a magnetostrictive platform. The biosensor was then exposed to solutions containing S. typhimurium bacteria. Binding between the antibody and antigen (bacteria) occurred and the additional mass of the bound bacteria caused a shift in the sensor's resonant frequency. Sensors with different physical dimensions were exposed to different concentrations of S. typhimurium ranging from 10(2) to 10(9)CFU/ml. Detection limits of 5x10(3) CFU/ml, 10(5) CFU/ml and 10(7) CFU/ml were obtained for sensors with the size of 2 mmx0.4 mmx15 microm, 5 mmx1 mmx15 microm and 25 mmx5 mmx15 microm, respectively. Good agreement between the measured number of bound bacterial cells (as measured by scanning electron microscopy (SEM)) and frequency shifts was obtained.

Animals↗

Electrochemical study of the effect of nano-zinc oxide on microperoxidase and its application to more sensitive hydrogen peroxide biosensor preparation.

Direct electron transfer reactions of microperoxidase were achieved with the help of semiconductive zinc oxide nanoparticles on a pyrolytic graphite electrode. The enzyme could also exhibit fine electrocatalytic activity towards the reduction of hydrogen peroxide. Thereby, a hydrogen peroxide biosensor was constructed based on the electrocatalysis of microperoxidase. Further studies revealed that after irradiating the microperoxidase/zinc oxide nanoparticles co-modified electrode with UV light for 4h, the catalytic ability of microperoxidase could be greatly promoted, which could be beneficial to developing more sensitive hydrogen peroxide biosensors. As comparison, it was found that the catalytic activity of the enzyme would be depressed if microperoxidase/agarose co-modified electrode was irradiated. We supposed it was the photovoltaic effect of the zinc oxide nanoparticles that improved the catalytic ability of microperoxidase.

Biosensing Techniques↗

Surface modified amorphous ribbon based magnetoimpedance biosensor.

Magnetoimpedance (MI) changes due to surface modification of the sensitive element caused by human urine, were studied with the aim of creating a robust biosensor working on a principle of electrochemical magnetoimpedance spectroscopy. A biosensor prototype with an as-quenched amorphous ribbon sensitive element was designed and calibrated for a frequency range of 0.5-10 MHz at a current intensity of 60 mA. Measurements as a function of the exposure time were made both in a regime where chemical surface modification and MI measurements were separated as well as in a regime where they were done simultaneously. The MI variation was explained by the change of the surface magnetic anisotropy. It was shown that the magnetoimpedance effect can be successfully employed as a new option to probe the electric features of the Fe(5)Co(70)Si(15)B(10) amorphous ribbon magnetic electrode surface modified by human urine.

Biosensing Techniques↗

Screen-printed biosensors for glucose determination in grape juice.

An approach to the glucose determination by amperometric biosensing in wine industry applications is presented. Integrated screen-printed biosensors based on horseradish peroxidase (HRP) and glucose oxidase (GOx) have been developed. The experimental design methodology has been used to find the optimum conditions of the experimental variables, in such a way that a chronoamperometric response specific for glucose was recorded. Under these conditions, repeatability and reproducibility of the modified electrodes have been analyzed. The detection limit for glucose has been calculated taking into account the probability of false positive (alpha) and negative (beta), reaching a medium value of 4.37+/-0.21 micromol dm-3 (alpha=beta=0.05, and a replicate n=4). The biosensor was applied to the determination of glucose in white wine samples.

Beverages↗