PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Conditioning, Operant”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

Cellular investigations of behavioral reinforcement.

Using the hippocampal-slice preparation, we attempted to demonstrate operant conditioning of pyramidal cell activity using local micropressure applications of transmitters and drugs as reinforcement; the same injections administered independently of bursting provided a control for direct pharmacological stimulation or facilitation of firing. The results suggested that the spontaneous bursting of individual CA1 pyramidal neurons may be reinforced with activity-contingent injections of dopamine and cocaine, whereas, CA3-bursting responses may be reinforced with contingently-applied dynorphin A. We sought to confirm these indications of cellular reinforcement at the behavioral level in studies of hippocampal self-administration (despite the fact that the hippocampus has been ignored as a brain site for chemical self-administration experiments). The results suggested that dynorphin A is a powerful reinforcer of hippocampal self-administration behavior when injected in the CA3 field; experiments still in progress suggest that dopamine can reinforce self-administration behavior when injected in the CA1 field. Successful prediction of new behavioral data from operant-conditioning data at the cellular level helps to validate the cellular data by providing suggestive evidence of interrelationship between cellular and behavioral operant conditioning processes.

Animals↗

Glucose transporter plasticity during memory processing.

Various types of learning, including operant conditioning, induce an increase in cellular activation concomitant with an increase in local cerebral glucose utilization (LCGU). This increase is mediated by increased cerebral blood flow or changes in brain capillary density and diameter. Because glucose transporters are ultimately responsible for glucose uptake, we examined their plastic expression in response to cellular activation. In vitro and in vivo studies have demonstrated that cerebral glucose transporter 1 (GLUT1) expression consistently parallels changes in LCGU. The present study is the first to investigate the effect of memory processing on glucose transporters expression. Changes in GLUT expression produced by training in an operant conditioning task were measured in the brain of CD1 mice. Using semi-quantitative immunohistochemistry, Western blot and real time RT-PCR the cerebral GLUT1 and GLUT3 expression was quantified immediately, 220 min and 24 h following training. Relative to sham-trained and naive controls, operant conditioning training induced an immediate increase in GLUT1 immunoreactivity level in the hippocampus CA1 pyramidal cells as well as in the sensorimotor cortex. At longer post-learning delays, GLUT1 immunoreactivity decreased in the sensorimotor cortex and putamen. Parallel to the changes in protein levels, hippocampus GLUT1 mRNA level also increased immediately following learning. No effect of learning was found on hippocampal GLUT3 protein or mRNA expression. Measures of changes in glucose transporters expression present a link between cellular activation and glucose metabolism. The learning-induced localized increases in GLUT1 protein as well as mRNA levels observed in the present study confirm the previous findings that GLUT1 expression is plastic and respond to changes in cellular metabolic demands.

Animals↗

Interpreting the effects of temperature and solvent composition on separation of amino-acid racemates by chiral ligand-exchange chromatography.

Routinely applied at both preparative and analytical scales, chiral ligand-exchange chromatography (CLEC) separates enantiomers capable of chelating a divalent transition-metal-ion through a pair of coordinating electronegative atoms. CLEC separation efficiencies are strongly dependent on column operating conditions, including temperature and mobile-phase solvent composition. Although previous empirical studies provide some useful guidelines for optimizing column operating conditions, the fundamental mechanisms underlying the unusually high sensitivity of CLEC performance to operating temperature and solvent composition remain poorly understood, limiting efforts to develop a comprehensive model for the technology. To address this problem, we report transport and chemical equilibria data for the separation of alpha-amino acids on a Nucleosil chiral-1 column presenting L-hydroxyproline as the immobilized ligand. Solute transport is found to be limited by pore diffusion at all column operating temperatures and solvent compositions, validating the existence of local equilibria throughout the column. Changes in separation performance are found to correlate with changes in chemical equilibria, emphasizing the need to carefully account for all speciation within the column when modeling CLEC and providing important fundamental data to achieve this goal. Each enantiomer participates in a large number of solution-phase complexes. As a result, the thermodynamic driving force for separation is unusually complex, allowing subtle changes in column operating conditions to mediate significant changes in speciation profiles and separation efficiency. A reaction-equilibria model accounting for all speciation within the CLEC column is proposed and used to estimate enantiomer partition coefficients and retention times.

Amino Acids↗

Ride vibration on tractor-implement system.

India is the largest manufacturer of tractors in the world. They are used for primary and secondary tillage operations and as a means of transportation. Vibration in tractor driving can cause deafness and disorders of the spinal column and stomach. The effect of implements on tractor ride is not well understood in India. The present study was undertaken to quantify ride vibration of a low horsepower tractor-implement system. Tractor ride vibration levels have been measured at the person-seat interface along three mutually perpendicular axes, longitudinal, lateral and vertical, under different operating conditions. It was observed that the acceleration levels increased as forward speed of travel increased under most of the operating conditions. There was no conclusive difference in measured acceleration levels on a tar-macadam road and a farm road during transport mode. The measured ride vibration levels under different operating conditions were evaluated as per ISO 2631/1 (1985), Geneva, and BS 6841 (1987), London, standards. On the basis of this study, it is concluded that the exposure time for the tractor operator should not exceed 2.5 h during ploughing and harrowing operations. Increasing exposure time may cause severe discomfort, pain and injury.

Agriculture↗

A factorial experiment for optimizing the PCR conditions in routine genotyping.

Although most PCRs would produce proper PCR products when first tried, a general optimization is required to yield the best results. This optimization is often achieved by changing one factor at a time. However, this may lead to suboptimal results, since interactions between conditions are difficult to detect with this approach. In the present study, we describe the factorial optimization of PCR conditions for microsatellite genotyping, by introducing small systematic variations in conditions during the genotyping process. The hypothesis was that small changes will not affect genotyping results, but will provide information about the optimality of current conditions. The conditions to vary were the concentrations of buffer, MgCl(2), dNTPs, primers, Taq polymerase and DNA, the annealing temperature (T(a)) and the number of cycles. We show that, by a 2(8) factorial experiment, it is possible to identify not only the factors responsible for obtaining good results, but also those responsible for bad results. However, the condition leading to the highest signals is not necessarily the best operational condition. The best operational condition is minimally sensitive to random pipetting fluctuations and yields reliable genotypes as well.

Analysis of Variance↗

Perceptions of bed rest by anorexic patients.

OBJECTIVE: Few studies have investigated perceptions of operant conditioning programs by anorexic patients. This study examined patients' perceptions of the Bed Rest (BR) component which is employed in some operant conditioning programs. METHODS: A sample of 48 anorexic inpatients was administered a survey to elicit their attitudes towards BR. RESULTS: Results from the survey suggested that most patients perceived BR in a negative way. The main complaint, however, was not punishment or humiliation, as predicted, but isolation and boredom. A number of patients concluded that they wanted more individualization and distraction and less restriction while on BR. DISCUSSION: The findings justify the use of BR within a humane framework in the inpatient treatment of anorexia nervosa, but suggest that patients' perceptions of BR warrant systematic scrutiny.

Adolescent↗

A controlled study of the effects of applied relaxation and applied relaxation plus operant procedures in the regulation of chronic pain.

Chronic back/joint pain patients participated in a comparative study of relaxation and operant therapies for chronic pain. Patients were randomly assigned to: (1) a waiting-list control, or to either (2) an applied relaxation, or (3) an applied relaxation plus operant conditioning treatment programme. Waiting patients were subsequently randomly assigned to active treatment. The results indicated that the treatment groups tended to do significantly better than the waiting-list control group for pain, medicine use, activity, and depression, but there were few clear differences between the treatment groups. Applied relaxation plus the operant programme was significantly better than relaxation for medicine reduction, and applied relaxation was better than relaxation and operant conditioning for a patient evaluation of reaching treatment goals. Within-group and single-subject analyses indicated that there were significant improvements between pre- and post-tests for the treatment groups, but not for the waiting-list control group. Follow-up data indicated maintenance, and that applied relaxation had significantly lower pain ratings than applied relaxation plus operant conditioning. Taken as a whole, the results show that applied relaxation can produce significant decreases in pain, and that the addition of an operant programme does not improve pain reductions, but does tend to improve results with activity and especially medicine intake variables.

Adult↗

Intra-operator and inter-operator reliability of surface electromyography in the clinical evaluation of back muscles.

As a prerequisite to the use of a test battery based on electromyographic (EMG) analysis of the paraspinal muscles for identifying and remedying back muscle dysfunction, the intra- and inter-operator reliability was assessed. Fifteen volunteers underwent EMG tests on three occasions. The test subjects were asked to perform 22 exercises, subdivided into four categories: coordination, stabilization, balance and strength exercises. The time interval between the tests was one week. The myoelectric signals of the multifidus (MF) and iliocostalis lumborum pars thoracis (ICLT) were analysed with regard to amplitude (averaged EMG) and frequency (zero cross rate). The results indicated that the reliability was better for the MF than for the ICLT, and also for exercises at higher loads (strength exercises). In the intra-operator condition, the reproducibility of the averaged EMG was good (ICC>0.75), except for the balance exercises (ICC = 0.40-0.74). In general, the averaged EMG in the inter-operator condition and the zero cross rate in both the intra- and inter-operator conditions are less or poorly reliable. These results demonstrate that when back muscle function is evaluated during coordination, stabilization and strength exercises, only the averaged EMG parameter has acceptable reproducibility over time when assessed by the same operator.

Adult↗

[Changes in blood pressure, heart rate, respiration frequency and ECG in rhesus monkeys exposed to socio-emotional stress].

Blood pressure, heart rate, respiration frequency and ECG parameters were measured in 3 juvenile male rhesus monkeys under acute and chronic influence of a stepped load schedule including positive (nutritional), negative (pain-related) and socially operant conditioning and phases of a pharmacological sensibilization (angiotensin-II) of the cardiovascular system. The results suggest a general adaptation to the positively operant conditioning, while the latter stressing influences (either single or in combination) produced blood pressure and heart rate elevations, which had the character of dysregulatory functional changes (borderline hypertension model) and were reached by other authors, if at all, only through stronger stress influences.

Animals↗

Biomechanical study of anterior spinal instrumentation configurations.

The biomechanical impact of the surgical instrumentation configuration for spine surgery is hard to evaluate by the surgeons in pre-operative situation. This study was performed to evaluate different configurations of the anterior instrumentation of the spine, with simulated post-operative conditions, to recommend configurations to the surgeons. Four biomechanical parameters of the anterior instrumentation with simulated post-operative conditions have been studied. They were the screw diameter (5.5-7.5 mm) and its angle (0 degrees - 22.5 degrees), the bone grip of the screw (mono-bi cortical) and the amount of instrumented levels (5-8). Eight configurations were tested using an experimental plan with instrumented synthetic spinal models. A follower load was applied and the models were loaded in flexion, torsion and lateral bending. At 5 Nm, average final stiffness was greater in flexion (0.92 Nm/degrees) than in lateral bending (0.56 Nm/degrees) and than in torsion (0.26 Nm/degrees). The screw angle was the parameter influencing the most the final stiffness and the coupling behaviors. It has a significant effect (p < or = 0.05) on increasing the final stiffness for a 22.5 degrees screw angle in flexion and for a coronal screw angle (0 degrees) in lateral bending. The bi-cortical bone grip of the screw significantly increased the initial stiffness in flexion and lateral bending. Mathematical models representing the behavior of an instrumented spinal model have been used to identify optimal instrumentation configurations. A variation of the angle of the screw from 22.5 degrees to 0 degrees gave a global final stiffness diminution of 13% and a global coupling diminution of 40%. The screw angle was the most important parameter affecting the stiffness and the coupling of the instrumented spine with simulated post-operative conditions. Information about the effect of four different biomechanical parameters will be helpful in preoperative situations to guide surgeons in their clinical choices.

Biomechanical Phenomena↗

[The design and evaluation of horizontal pipe mini-flame atomization and ionization synchronous detector in GC/AAS].

Gas chromatography/atomic absorption spectroscopy(GC/AAS) is a good method for the species analysis of organometallic compounds. But the traditional atomizers are not very suitable for this technology and all of them response only to one kind of signal--the concentration of the metallic atoms of the ground state. They can not give any information about the organic group of organometallic compounds and organic compounds which coexist with the former. For GC/AAS we want to design and manufacture a new kind of detector which is much more sensitive and has a much smaller dead volume and will sensitively and synchronously response to the atomization signal of organometallic compound and ionization signal of organic compound. The authors have noticed that the atomization of organometallic compound and ionization of organic compound have been existing in the same hydrogen flame. The question is how to gain and exchange and output the two signals which are completely different in characters. For this purpose we designed and manufactured a new type of horizontal pipe mini-flame atomization and ionization synchronous detector. The key part is a T type glass tube (80 mm x 13 mm x 10 mm i.d.) which covers horizontally on the jet of the mini-flame atomizer and a long pipe stainless steel collector (70 mm x 9.5 mm o.d. x 9 mm i.d.) is tightly inserted in the tube. The light beam of the hollow cathode lamp passes through the hydrogen flame along the axial center of the glass tube and the ground state metallic atoms in the flame diffuses to both ends of the tube along the axial center of the glass tube too. This process enriches the depth of the light absorption and then increases the sensitivity of atomization. At the same time the long pipe collector can enrich the collection efficiency of the ionization and increases the sensitivity and widens the linear range. So the detector can synchronously and sensitively detect the organometallic and organic compounds. The detection limit for atomization of the organometallic compound(diethylmercury) is 2.5 x 10(-11) g.s-1 and for ionization of the organic compound (benzene) is 1.0 x 10(-11) g.s-1. The linear range is 7.0 x 10(2) for atomization of diethylmercury (r = 0.9989) and 2.5 x 10(5) for ionization of benzene (r = 0.9992). The selectivity of the detector to the organic solvent under the optimum operating condition of atomization is 10(4)-10(7). The relative standard deviation (RSD, n = 11) of the peak area in the optimum operating conditions of atomization for the organometallic compound (diethylmercury) and of ionization for the organic compound (benzene) is 1.8% and 1.5% respectively. Under the same operating condition, the atomization and the ionization can not reach the optimum performance at the same time. If the atomization is in the optimum performance state, the performance for ionization is like a chromatographic thermal conductivity detector (TCD). The optimum performance of the atomization and ionization can be quickly adjusted by changing the flow rates of the corresponding gases such as H2, N2 and air.

Benzene↗

The prediction of variability occurring in fluidized bed coating equipment. I. The measurement of particle circulation rates in a bottom-spray fluidized bed coater.

The purpose of this work was to investigate the effect that changes in design and process variables had on the movement of particles around a fluidized bed coating apparatus. To measure the mean and variance of the particle cycle time distribution (CTD), the number of passages taken by a magnetic tracer particle through the spray zone was measured by a detector coil wound around the partition. The reproducibility of the measurement technique was tested by taking repeated measurements of the tracer particle movement, using similar bed operating conditions, and the method was found to give reproducible results. A series of experiments was carried out by varying operating conditions such as the partition gap, fluidizing air rate, and partition diameter and length, and measuring the change in the rate at which the tracer particle circulated in the coating device. The results of the experiments showed that, over the range of parameters tested in this work, the partition gap had the strongest influence on the rate of particle circulation. Moreover, for the 6-in.-diameter Wurster process used in the current work, the mean circulation time for the 1.1-mm-diameter Nu-Pareil particles was found to vary over the range of 2.2-10.4 sec. In addition, the mean and standard deviation of the CTD could be linearly correlated over a wide range of operating conditions, with a correlation coefficient of 0.80. Finally, an estimate of the variability in mass coating uniformity was made based on the results from the cycle time distributions. It was concluded that the effect of variability in the CTD could account for only a small fraction of the variability in the observed mass coating distribution.

Technology, Pharmaceutical↗

Review of computerized orthoptics with specific regard to convergence insufficiency.

Traditional vision training or orthoptics has used line or contour targets to eliminate suppression and improve vergence performance. Manipulation of these stimuli is slow and arduous. Line stimuli require an experienced doctor/technician to interpret responses. Recently, automated vision training using microprocessor anaglyph stimuli, i.e., random dot stereograms (RDS), has been used in an operant conditioning paradigm. This technique has improved motivation of the patient, improved reliability, and provided standardization of therapy. In addition, the utilization of RDS associated with operant conditioning has been shown to improve vergence performance and to reduce asthenopia in the convergence insufficiency patient.

Accommodation, Ocular↗

Autogenic-feedback training: a potential treatment for orthostatic intolerance in aerospace crews.

Postflight orthostatic intolerance has been identified as a serious biomedical problem associated with long-duration exposure to microgravity in space. High priority has been given to the development of countermeasures for this disorder that are both effective and practical. A considerable body of clinical research has demonstrated that people can be taught to increase their own blood pressure voluntarily, and that this is an effective treatment for chronic orthostatic intolerance in paralyzed patients. The current pilot study was designed to examine the feasibility of adding training in control of blood pressure to an existing preflight training program designed to facilitate astronaut adaptation to microgravity. Using an operant conditioning procedure, autogenic-feedback training (AFT), three men and two women participated in four to nine training (15-30-minute) sessions. At the end of training, the average increase in systolic and diastolic pressure, as well as mean arterial pressures, that the subjects made ranged between 20 and 50 mm Hg under both supine and 45 degrees head-up tilt conditions. These findings indicate that AFT may be a useful alternative treatment or supplement to existing approaches for preventing postflight orthostatic intolerance. Furthermore, the use of operant conditioning methods for training cardiovascular responses may contribute to the general understanding of the mechanisms of orthostatic intolerance.

Adult↗

Assessment of dose and risk to the body following conventional and spiral computed tomography.

BACKGROUND: Computed tomography (CT) is one of the most frequently used examination procedures in diagnostic radiology and the dose given to the patients is higher than in general radiographic procedures. In this study LiF chip thermoluminescent dosimeters (TLD-100) were placed in each relative organ or tissue position, including head, chest and abdomen, in a Rando phantom. CT was performed using both conventional and spiral modes, and effective dose and effective dose equivalent were assessed for each organ or tissue scanned. METHODS: The TLD reader used in this experiment was controlled at a nitrogen flow rate of 450 ml/min, preheat time of 14 seconds, reading time of 16 seconds and annealing time of 16 seconds. This CT scanner can be used to perform both conventional and spiral tomography. Operating conditions for spiral tomography were 120 kV, 80 mA for scout film, and 120 kV, 200 mA, 1 sec/slice for each scanning. However, for conventional tomography, the operating conditions were 120 kV, 80 mA for scout film and 120 kV, 160 mA, 1.5 sec/slice for each scanning. These operating conditions are satisfactory to most clinical applications, and therefore were adopted for the present studies. RESULTS: Results showed that, in both effective dose and effective dose and effective dose equivalent, conventional tomography was higher than spiral tomography. The average effective doses for each part were measured to be 1.89 and 4.95 mSv for the head, 30.01 and 40.65 mSv for the chest, and 12.85 and 19.62 mSv for the abdomen of spiral and conventional CT, respectively. Higher carcinogenic risk was assessed in organs such as liver, lung, stomach and bone marrow, other organs had a relatively lower incidence of risk. CONCLUSIONS: The main purpose of this study was to obtain distribution values of effective dose and effective dose equivalent, and to know the probability of carcinogenic effect upon each organ or tissue after CT scanning. Results showed the average effective dose for spiral CT to be less than conventional CT, and the dose in the body surface was generally lower than the dose in the central region.

Humans↗

Modification of provider behavior to achieve improved asthma outcomes.

Despite an abundance of scientific evidence supporting the use of guidelines, adherence to asthma practice guidelines by physicians generally is low, regardless of provider and patient characteristics. As a result, scientific information, obtained with great effort and at huge expense, is not being translated into clinical practice. To remedy this, we developed a disease management program that emphasizes alteration of provider behavior using operant conditioning. We did this by placing asthma educators in private offices for up to 8 weeks. The educators used a combination of problem-based learning, role modeling, and operant conditioning with positive reinforcement to affect behavior change. As a result of these behavior changes, by the end of 8 weeks the cost to treat asthma patients decreased, despite an increase in the cost of medications. We concluded that behavior-oriented programs targeted at provider offices can lead to improved asthma care while reducing costs.

Asthma↗

Microbial community structure and activity in a compartmentalized, anaerobic bioreactor.

The objective of this study was to evaluate staging and its effects on reactor performance in a compartmentalized bioreactor, designated the anaerobic migrating blanket reactor (AMBR). The AMBR was operated by reversing the flow several times per day, which allowed for substantial biomass migration without biomass accumulation in the final compartment. During reactor startup, the structures of the microbial communities in the five compartments were quite similar despite substantial differences in substrate types and concentrations in the different compartments. During the rest of the operational period, biomass migration was reduced by changing operating conditions and, as a result, a larger difference in the structures of the microbial communities developed for the different compartments (biomass staging). For example, after changing operating conditions, rRNA levels for the acetate-utilizing methanogen Methanosaeta concilii were approximately 35 and 10% of the total rRNA in the middle and outside compartments, respectively (before changing operating conditions these levels were approximately 20 and 12% of the total rRNA, respectively). Promoting larger differences in the structures of the microbial communities for the different compartments did not improve reactor performance as lower levels of M. concilii in the outside compartments hindered acetate removal and compromised effluent quality.

Biomass↗