Incidence of electromagnetic interference in implantable cardioverter defibrillators.

Electromagnetic interference (EMI) with ICDs can lead to temporary inhibition of the device or to inappropriate delivery of antitachycardia pacing and shocks. The incidence of interactions between electronic devices and the current generation of ICDs is not known. In a retrospective study of 341 patients (665 patient-years) who underwent a regular follow-up every 3 months, five episodes of EMI were detected in four different patients. The risk for receiving inappropriate shocks due to EMI is < 1% per year and patient. In conclusion, although inappropriate delivery of shocks by ICDs due to EMI rarely occurs, patient information should emphasize the avoidance of situations of possible interference. Further efforts concerning lead technology and detection algorithms are necessary to minimize the risk of EMI.

Aged↗

Hyperkalemia diagnosed by implantable cardioverter defibrillator T wave sensing.

A patient with congestive heart failure and an ICD had undergone atrioventricular nodal ablation and optimization of heart failure medical therapy. Intracardiac T wave sensing by the ICD drew attention to the new development of asymptomatic hyperkalemia. Surface ECG features of hyperkalemia were not readily identified due to pacemaker dependence.

Defibrillators, Implantable↗

Prospective evaluation of catheter ablation in patients with implantable cardioverter defibrillators and multiple inappropriate ICD therapies due to atrial fibrillation and type I atrial flutter.

The high incidence of inappropriate therapies due to drug refractory supraventricular tachycardia remains a major unsolved problem of the ICD. Most of the inappropriate therapies for supraventricular tachycardia are caused by AF and type I atrial flutter with rapid ventricular response. The purpose of this prospective study was to determine the usefulness of AVN modulation or ablation for rapid AF and ablation of the tricuspid annulus-inferior vena cava (TA-IVC) isthmus for type I atrial flutter in ICD patients with frequent inappropriate ICD interventions. Eighteen consecutive patients were enrolled in this study. Twelve patients received a mean of 34 +/- 36 antitachycardia pacing (ATP) and 41 +/- 32 shock therapies for rapid AF during 49 +/- 39 months, and 6 patients a mean of 111 +/- 200 ATP and 11 +/- 8 shock therapies for type I atrial flutter during 52 +/- 37 months preceding ablation procedure. Modification of the AVN was successful in 10 (83%) of 12 AF patients, in 2 (17%) patients ablation of the AVN was performed. A complete TA-IVC isthmus block was achieved in 5 (83%) of 6 atrial flutter patients. Three (25%) AF patients had 11 +/- 24 recurrences of ATP and 0.4 +/- 1.1 shock therapies for rapid AF during 15 +/- 7 months. None of the atrial flutter patients had recurrences of inappropriate therapies for type I atrial flutter during 14 +/- 8 months, but two (33%) patients had inappropriate ICD therapies for type II atrial flutter or rapid AF. There was an overall mean incidence of 18 +/- 22 inappropriate ICD therapies per 6 months before and 4 +/- 9 per 6 months after the ablation procedure (P < 0.05). In conclusion, radiofrequency catheter modification or ablation of the AVN for rapid AF and ablation for atrial flutter type I are demonstrated to be highly effective in the majority of ICD patients with drug refractory multiple inappropriate ICD therapies.

Aged↗

Washing machine associated 50 Hz detected as ventricular fibrillation by an implanted cardioverter defibrillator.

This case report describes a patient with an automatic ICD who suffered a defibrillation shock without warning symptoms. An electrical interference can be observed in the stored EGM of the episode. The patient explained that the moment he felt the shock he was touching a washing machine. After correct grounding of this machine the patient did not suffer more inappropriate shocks.

Defibrillators, Implantable↗

Enhanced detection criteria in implantable cardioverter defibrillators: sensitivity and specificity of the stability algorithm at different heart rates.

The lack of specificity in the detection of ventricular tachyarrhythmias remains a major clinical problem in the therapy with ICDs. The stability criterion has been shown to be useful in discriminating ventricular tachyarrhythmias characterized by a small variation in cycle lengths from AF with rapid ventricular response presenting a higher degree of variability of RR intervals. But RR variability decreases with increasing heart rate during AF. Therefore, the aim of the study was to determine if the sensitivity and specificity of the STABILITY algorithm for spontaneous tachyarrhythmias is related to ventricular rate. Forty-two patients who had received an ICD (CPI Ventak Mini I, II, III or Ventak AV) were enrolled in the study. Two hundred ninety-eight episodes of AF with rapid ventricular response and 817 episodes of ventricular tachyarrhythmias were analyzed. Sensitivity and specificity in the detection of ventricular tachyarrhythmias were calculated at different heart rates. When a stability value of 30 ms was programmed the result was a sensitivity of 82.7% and a specificity of 91.4% in the detection of slow ventricular tachyarrhythmias (heart rate < 150 beats/min). When faster ventricular tachyarrhythmias with rates between 150 and 169 beats/min (170-189 beats/min) were analyzed, a stability value of 30 ms provided a sensitivity of 94.5% (94.7%) and a specificity of 76.5% (54.0%). For arrhythmia episodes > or = 190 beats/min, the same stability value resulted in a sensitivity of 78.2% and a specificity of 41.0%. Even when other stability values were taken into consideration, no acceptable sensitivity/specificity values could be obtained in this subgroup. RR variability decreases with increasing heart rate during AF while RR variability remains almost constant at different cycle lengths during ventricular tachyarrhythmias. Thus, acceptable performance of the STABILITY algorithm appears to be limited to ventricular rate zones < 170 beats/min.

Aged↗

Absence of a morning peak in ventricular tachycardia and fibrillation events in nonischemic heart disease: analysis of therapies by implantable cardioverter defibrillators.

A growing number of Japanese patients are being treated with ICDs. Efforts are warranted to minimize the rates of ICD shocks that cause discomfort and anxiety. The circadian distribution of ICD discharges was investigated in 80 patients (57+/-10 years of age, 69 men) from ten Japanese medical centers. The underlying heart disease was ischemic in 27 versus nonischemic in 53 patients. All patients had refractory VT or VF, and received appropriate shocks confirmed by stored data retrieved from the memory of the ICD. In the analysis of 354 appropriate shocks delivered in the overall population, a morning peak in VT or VF episodes was observed. However, subgroup analyses of the circadian distribution of ICD shocks revealed that the morning peak in VT or VF episodes was confined to patients with ischemic heart disease and was blunted by treatment patients with beta-adrenergic blockers. The absence of a morning peak in appropriate ICD shocks among patients with nonischemic heart disease remains unexplained and was unrelated to the use of beta-adrenergic blockers. In conclusion, the circadian pattern of appropriate ICD discharges was related to the underlying heart disease. In patients with ischemic heart disease, recurrences of VT or VF peaked in the morning. In contrast, in patients without ischemic heart disease, the episodes of VT or VF were evenly distributed during waking hours. Beta-adrenergic blockers appeared to blunt the morning peak in VT or VF among patients with ischemic heart disease.

Adrenergic beta-Antagonists↗

Implantable cardioverter defibrillator T wave oversensing caused by hyperglycemia.

This case report highlights a previously unreported cause of T wave oversensing in a patient with an ICD and recent onset diabetes. Consistent T wave oversensing was observed at elevated serum glucose levels and this finding was reproduced with a glucose challenge. No T wave oversensing was seen during treatment of hyperglycemia. Alterations in serum chemistry may account for intermittent T wave oversensing in patients with ICDs.

Defibrillators, Implantable↗

Electrogram width parameter analysis in implantable cardioverter defibrillators: Influence of body position and electrode configuration.

The "EGM width criterion" is a discrimination algorithm that was available in the last generation ICDs. It improved ventricular tachycardia detection by withholding inappropriate therapy deliveries in the presence of narrow QRS tachycardias. The accuracy of the algorithm depends on the optimal settings of the intracardiac EGM source, the "slew thresholds," and the "width threshold." The possible dependence of these parameters on body position may affect the detection efficacy. Whether these effects can be minimized by a proper choice of the electrode configuration used for signal analysis is still to be investigated. This study aimed to evaluate the stability of the slew threshold and width threshold obtained in the supine and orthostatic positions detected by the tip-to-ventricular coil and can-to-ventricular coil electrode configurations. Their time dependence was also evaluated at the 6-month follow-up. Fifty-eight patients who were recipients of an ICD (model Medtronic 7223cx and 7227cx) were included in the study. Changing from supine to orthostatic position caused a marked variation of slew and width thresholds (21.0 +/- 13.9 V/s and 10.1 +/- 9.6 ms, respectively) in 36% of patients with tip-to-ventricular coil and in 44% of patients with can-to-defibrillating coil (the mean slew threshold variation was in this case 17.6 +/- 15.8 V/s, while the mean width threshold variation was 18.8 +/- 21.0 ms). Width threshold variation was statistically significant (P < 0.02) with the latter electrode configuration. Slew thresholds settings changed between the 1- and 6-month follow-ups in the 75% of patients with can-to-defibrillating coil configuration and in 50% with tip-to-defibrillating coil. These time related variations were significantly larger with the tip-to-defibrillating coil configuration (P < 0.01). In conclusion, EGM width parameters may change between supine and orthostatic position and over time with tip-to-defibrillating coil configuration and can-to-defibrillating coil configuration. The former configuration was less sensitive to body position changes, but more sensitive to time related variations. These findings may be useful for optimal programming of the EGM width criterion, but if parameter programming based on these results can improve the discrimination specificity still needs to be investigated.

Aged↗

Inappropriate tachycardia detection by a biventricular implantable cardioverter defibrillator.

This case describes "double counting" of intrinsic conduction due to the combination of intraventricular conduction delay and the merging of the electrograms from the right and left ventricle (coronary sinus) leads in a biventricular cardioverter defibrillator. This situation prompted asymptomatic antitachycardia pacing. Lengthening of AV conduction by betablocker solved the problem.

Adrenergic beta-Antagonists↗

Robotically enhanced placement of left ventricular epicardial electrodes during implantation of a biventricular implantable cardioverter defibrillator system.

Biventricular pacing has gained increasing acceptance in advanced heart failure patients. One major limitation of this therapy is positioning the left ventricular stimulation lead via the coronary sinus. This report demonstrates the feasibility of totally endoscopic direct placement of an epicardial stimulation lead on the left ventricle using the daVinci surgical system.

Aged↗

The relative lymphocyte count predicts death in patients receiving implantable cardioverter defibrillators.

Although the survival benefit conveyed by the automatic defibrillator has been well established for several subsets of patients, some patients who receive the device still die early. The relative lymphocyte count (%L), a portion of the white blood cell count differential, which is decreased in states of excess systemic stress, has prognostic value in patients with coronary artery disease and advanced heart failure. This study assessed the association of %L with survival in patients receiving automatic defibrillators. A total of 136 consecutive patients (81% men; mean age 64 +/- 12 years) who were using automatic defibrillators were followed for 29.6 months. The mean ejection fraction was 0.36 +/- 0.17, the mean %L was 22.7 +/- 8%, and 55 (40%) patients had decreased %L (< 20.3%). There were 20 deaths, for a 4-year survival of 71.5%. The association of %L with time to death was assessed by Cox proportional hazards analysis. Ejection fraction (P = 0.005), %L (P = 0.01), and diagnosis (P = 0.03) were independently associated with time to death on multivariate analysis. One-year and 4-year survival rates were 93% and 54%, respectively, for the 55 patients with abnormal %L, compared with 99% and 84%, respectively, for the 81 with normal %L (P = 0.03). This suggests that the %L is a readily accessible prognostic marker in patients using automatic defibrillators. This association is independent of age, sex, diagnosis, and ejection fraction.

Aged↗

Inhibition of bradycardia pacing and detection of ventricular fibrillation due to far-field atrial sensing in a triple chamber implantable cardioverter defibrillator.

Oversensing of intracardiac signals or myopotentials may cause inappropriate ICD therapy. Reports on far-field sensing of atrial signals are rare, and inappropriate ICD therapy due to oversensing of atrial fibrillation has not yet been described. This report presents a patient with a triple chamber ICD and a history of His-bundle ablation who experienced asystolic ventricular pauses and inappropriate detection of ventricular fibrillation due to far-field oversensing of atrial fibrillation. Several factors contributed to the complication, which resolved after reduction of the ventricular sensitivity.

Aged↗