PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Extracorporeal Circulation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

[Hemodynamic-kinetic controlled extracorporeal circulation in heart surgery].

Mimicking the physiological characteristics of the circulatory system, pulsatile bloodflow has also been introduced into extracorporeal perfusion to avoid known postoperative complications. In a mathematical consideration of the situation bloodflow is seen as a function of time F(t) for approximately constant vessel diameter over a given time. The kinetic energy of a column of blood produced by the heart-lung machine is transmitted directly to the arterial circulation via the aorta. The nature of the energy release can give rise to both positive (organ perfusion) and negative (damage to endothelium) effects. This study investigates how this energy release can be optimised, using the following experimental approach. A Doppler flow-measuring probe is placed on the ascending aorta to monitor the extracorporeal circulation. At the same time, the blood pressure is measured and converted to a pressure-flow curve via an A/D converter. On the basis of the parameters thus obtained, the energy released by the heart-lung machine is calculated. By regulating the functional parameters of a new generation of heart-lung machines, the bloodflow can then be adapted to the physiological requirements. Within the pulse period (cycle) a 20% rise phase ending in a slightly increasing plateau is established. The energy increase within a cycle should not exceed 150 joules. To optimize the mode of functioning of the heart-lung machine, we introduced the "energy-equivalent pressure" (EEP). Adaptation of the EEP to the physiological conditions required a basic flow of 60% at a pulse rate of 60/min and a pulse duration of 35% within the pulsatile flow interval.

Adult↗

Improved methods for measurement of gaseous microbubbles during extracorporeal circulation.

The detection and quantification of gaseous microbubbles in the arterial line of the extracorporeal circuit (ECC) are very important aims for quality assurance of perfusion. A system that allows a continuous measurement of microbubble distribution in the range of 10 and 120 microm was tested. The two-channel ultrasonic bubble counter (UBC) was based on a 2-MHz ultrasound Doppler system with propriety ultrasound probes. The bubble size was determined using the backscattered Doppler signal and was corrected by means of a reference signal based on measurement conditions. Our studies have shown that the quality of this signal can be negatively affected in the clinical environment. Different influences are involved, such as electrocoagulation or electromagnetic disturbances. Various algorithms were tested and new ones were developed in order to minimize the effect of such interferences on the accuracy of the bubble detection. The on-line data were recorded during the entire surgical time to allow an off-line evaluation with different algorithms. This allowed us to obtain more exact results. Two clinical studies with 91 patients were performed with microbubbles measured in the arterial line during coronary artery bypass grafting (CABG) and valve replacement. The results confirmed the expected occurrence of microbubbles during various phases of surgery. The measurement itself proved to be resistant to different external disturbances.

Algorithms↗

SMART tubing presents an increased risk of disconnection during extracorporeal circulation.

A number of products exhibiting biocompatible features have been developed for use in extracorporeal blood circuits during cardiopulmonary bypass procedures. While attention has been focused on biocompatibility features of the blood-circuit interface, a number of issues applicable in clinical use of these circuits have arisen. Surface Modifying Additive Technology (SMART; Cobe Cardiovascular, Arvarda, CO) is one such technology. In this product, the structure of normal polyvinylchloride (PVC) tubing is altered through the blending of two copolymers to give a more biocompatible blood to plastic interface. In this study, we examined the in vitro mechanical ability of random samples (n = 10) of SMART and standard PVC tubing to withstand axial tension when the tubing was placed over a single barb of a connector. The tension required to remove the SMART tubing from the connector (83.3 +/- 7.3 [SD] N), was significantly less than standard PVC tubing (115.6 +/- 15.9 N; p < .0001, unpaired t test). The SMART tubing exhibited a 28% reduction in tubing to connector adhesion, which may have a significant effect on extracorporeal circuit disconnection and overall patient safety.

Accident Prevention↗

[Biological aspects of extracorporeal circulation].

Two problems are looked at in this work. That of glucose which is administered in considerable quantities during ECC and that of the iso-enzymes. The administration of glucose has two aims: one being the mechanical nature i.e. as an agent which decreases the risks of platelet aggregation, the other bio-energetic. But, owing to the CRABTREEE effect, an excess of glucose blocks the biosynthesis of ATP and a non-metabolisable structural analogue which has mechanical properties identical with glucose, such as fucose or rhamnose could be supplied instead. As far as the iso-enzymes are concerned, the author after having looked at the general value from the standpoint of signs and symptoms, suggests the study of two of them, cardiac lactic-dehydrogenase and the MB fraction of creatine phosphokinase could enable the follow-up of the course and of the consequences of extra-corporeal circulation.

Adenosine Triphosphate↗

In vivo effects of hypothermia on the microcirculation during extracorporeal circulation.

OBJECTIVE: Induced hypothermia has been shown to be protective during cardiac surgery, but also in traumatic, ischemic, burn, and neurological injury. In previous in vivo animal experiments, we documented increased leukocyte/endothelial (L/E) cell interaction following normothermic extracorporeal blood circulation (ECC). This study was carried out to investigate whether reduced core temperature during ECC affects the damage to the microcirculation as evidenced by leukocyte adherence and edema formation. METHODS: Intravital fluorescence microscopy was used on the dorsal skinfold chamber preparation in Syrian golden hamsters. ECC was introduced via a micro-rollerpump (1 ml/min) and a 60 cm silicon tube (1mm inner diameter) shunted between the carotid artery and the jugular vein after application of 300IE Heparin/kg per body weight. Experiments were performed in chronically instrumented, awake animals (age 10-14 weeks, weight 65-75 g). Animals of the experimental group were cooled to 18 degrees C body temperature while ECC, followed by a rewarming period (n=7), controls experienced ECC under normothermia (37 degrees C, n=7). RESULTS: 30 min ECC at 18 degrees C resulted in a decrease of rolling and adherent leucocytes (stickers) in postcapillary venules after 1, 4 and 8h compared with the control group (119+/-46 vs. 274+/-113 n/mm2, P<0.05, mean+/-SD; n=7 in each group). Functional capillary density was significantly reduced during hypothermia (80+/-16 vs. 148+/-16 cm/cm2, P<0.05), but restored after rewarming. In contrast, edema formation was markedly increased during hypothermia. CONCLUSIONS: Hypothermia during ECC significantly reduced L/E cell interaction in the early post-ECC period. Hypothermia markedly reduced microvascular perfusion, but was completely restored upon rewarming. Despite a reduced number of adherent leukocytes, no protection of endothelial barrier function was seen as a consequence of induced hypothermia.

Animals↗