PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polymers”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

Alkylamine odors from degradation of flocculant polymers in sludges.

The cationic organic polymers used to enhance thickening and dewatering processes are potential sources of strong odors. These polymers vary in chemical structure, and some may be more susceptible to biotic or abiotic degradation than others. The product organic amines will be volatilized most noticeably at high pH, as in lime addition. These possibilities were examined using several structural types of polymers combined with anaerobically digested sludge. Two commonly used polymers gave significant production of trimethylamine (TMA), which was released upon lime addition. Their structures were correlated with reactions that yield TMA. An initial ester hydrolysis step appears to be biologically mediated, but subsequent steps can occur due to alkaline conditions. An alternative cationic polymer structure did not generate TMA but required a much higher dose to effect sufficient conditioning of the sludge. The acrylamide-based polymers were shown to be the predominant source of TMA in limed sludges.

Biodegradation, Environmental↗

Shifts in chain-melting transition temperature of liposomal membranes by polymer-grafted lipids.

The chain-melting transition temperature of dipalmitoyl phosphatidylcholine (DPPC) bilayer membranes containing poly(ethylene glycol)-grafted dipalmitoyl phosphatidylethanolamine (PEG-DPPE) was determined by optical turbidity measurements. The dependence on content, Xp, of PEG-DPPE lipid was studied for different polar headgroup sizes, np, of the polymer lipid, throughout the lamellar phase of the mixtures with DPPC. Mean-field theory for the polymer brush regime predicts that the downward shift in transition temperature should vary with polymer size and content as npXp(5/3) (approximately npXp(11/6) for scaling theory). Any shift induced by the charge on PEG-lipids is independent of polymer size. These predictions are reasonably borne out for the longer polymer lipids (PEG molecular masses 750, 2000 and 5000 Da). Transition temperature shifts in the lamellar phase, before the onset of micellisation, are in the region of -1 to -2 degrees C (+/-0.1-0.2 degrees C) in reasonable accord with theoretical estimates of the lateral pressure exerted by the polymer brush. Shifts of this size are significant to the design of liposomes for controlled release of contents by mild hyperthermia.

1,2-Dipalmitoylphosphatidylcholine↗

Polymer-induced membrane contraction, phase separation, and fusion via Marangoni flow.

Experiments have shown that the depletion of polymer in the region between two apposed (contacting or nearly contacting) bilayer membranes leads to fusion. In this paper we show theoretically that the addition of nonadsorbing polymer in solution can promote lateral contraction and phase separation of the lipids in the outer monolayers of the membranes exposed to the polymer solution, i.e., outside the contact zone. This initial phase coexistence of higher- and lower-density lipid domains in the outer monolayer results in surface tension gradients in the outer monolayer. Initially, the inner layer lipids are not exposed to the polymer solution and remain in their original "unstressed" state. The differential stresses on the bilayers give rise to a Marangoni flow of lipid from the outer monolayers in the "contact zone" (where there is little polymer and hence a uniform phase) to the outer monolayers in the "reservoir" (where initially the surface tension gradients are large due to the polymer-induced phase separation). As a result, the low-density domains of the outer monolayers in the contact zone expose their hydrophobic chains, and those of the inner monolayers, to the solvent and to each other across the narrow water gap, allowing fusion to occur via a hydrophobic interaction. More generally, this type of mechanism suggests that fusion and other intermembrane interactions may be triggered by Marangoni flows induced by surface tension gradients that provide "action at a distance" far from the fusion or interaction zone.

Cell Membrane↗

The effect of chain length on protein solubilization in polymer-based vesicles (polymersomes).

Using a mean-field analysis we derive a consistent model for the perturbation of a symmetric polymeric bilayer due to the incorporation of transmembrane proteins, as a function of the polymer molecular weight and the protein dimensions. We find that the mechanism for the inhibition of protein incorporation in polymeric bilayers differs from that of their inclusion in polymer-carrying lipid vesicles; in polymersomes, the equilibrium concentration of transmembrane proteins decreases as a function of the thickness mismatch between the protein and the bilayer core, whereas in liposomes the presence of polymer chains affects the protein adsorption kinetics. Despite the increased stiffness of polymer bilayers (when compared to lipid ones), their perturbation decay length and range of protein-protein interaction is found to be relatively long. The energetic penalty due to protein adsorption increases relatively slowly as a function of the polymer chain length due to the self-assembled nature of the polymer bilayer. As a result, we predict that transmembrane proteins may be incorporated in significant numbers even in bilayers where the thickness mismatch is large.

Amino Acid Sequence↗

Temperature-dependent interaction of thermo-sensitive polymer-modified liposomes with CV1 cells.

Egg yolk phosphatidylcholine liposomes modified with a copolymer of N-acryloylpyrrolidine and N-isopropylacrylamide having a lower critical solution temperature at ca. 40 degrees C were prepared and an effect of temperature on their interaction with CV1 cells was investigated. The unmodified liposomes were taken up by the cells approximately to the same extent after 3 h incubation at 37 and 42 degrees C. In contrast, uptake of the polymer-modified liposomes by CV1 cells decreased slightly at 37 degrees C but increased greatly at 42 degrees C, compared to the unmodified liposomes. Proliferation of the cells was partly prohibited by the incubation with the unmodified liposomes encapsulating methotrexate at 37 and 42 degrees C. The treatment with the polymer-modified liposomes containing methotrexate at 37 degrees C hardly effected the cell growth. However, the treatment at 42 degrees C inhibited the cell growth completely. It is considered that the highly hydrated polymer chains attached to the liposome surface suppressed the liposome-cell interaction below the lower critical solution temperature of the polymer but the dehydrated polymer chains enhanced the interaction above this temperature. Because interaction of the polymer-modified liposomes with cells can be controlled by the ambient temperature, these liposomes may have potential usefulness as efficient site-specific drug delivery systems.

Acrylic Resins↗

Propranolol hydrochloride-anionic polymer binding interaction.

Three different anionic polymers namely Eudragit S 100, Eudragit L 100-55 (methacrylic acid copolymers), and sodium carboxymethylcellulose (NaCMC) were used to evaluate the propranolol hydrochloride-anionic polymer interaction. The physical and chemical properties of propranolol hydrochloride and anionic polymer complex were investigated using Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC). The DSC profiles demonstrated that the characteristic peak of propranolol hydrochloride cannot be found in the heating curve of the complexes, indicating that complex is different in physicochemical properties from the physical mixture of drug-polymer. The FTIR spectra also confirmed that there is an interaction between propranolol hydrochloride and methacrylic acid copolymers. The binding of the drug to the polymers was due to the existence of preferential hydrogen bonding between the amino group of the propranolol hydrochloride and the carboxylic functions of the polymers and that pH conditions can influence this binding.

Acrylic Resins↗

New configurations and applications of molecularly imprinted polymers.

Molecularly imprinted polymers (MIPs) are applicable in a variety of different configurations. For example, bulk polymers imprinted with beta-lactam antibiotics are presented to be used as stationary phases for the chromatographic separation of beta-lactam antibiotics with both aqueous and organic mobile phases. However, in some analytical applications, monosized spherical beads are preferred over the currently used ground bulk polymers. A precipitation polymerization technique allows preparation of monosized spherical imprinted beads with diameters down to 200 nm having excellent recognition properties for different target molecules. Nevertheless, with current imprinting protocols a substantial amount of template has to be used to prepare the polymer. This can be problematic if the template is poorly soluble, expensive or difficult to obtain. It is shown that for analytical applications, the functional monomer:template ratio can be drastically increased without jeopardizing the polymer's recognition properties. Furthermore, a substantial reduction of the degree of crosslinking is demonstrated, resulting in much more flexible polymers that are useful for example the preparation of thin imprinted films and membranes for sensors. Apart from analysis, MIPs also are applicable in chemical or enzymatic synthesis. For example, MIPs using the product of an enzyme reaction as template are utilized for assisting the synthetic reaction by continuously removing the product from the bulk solution by complexation. This results in an equilibrium shift towards product formation.

Anti-Bacterial Agents↗

Molecular recognition in imprinted polymers: thermodynamic investigation of analyte binding using microcalorimetry.

This study aimed at elucidating the interaction mechanism between an imprinted polymer and its template in aqueous environment with thermodynamic aspects. The herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) was chosen as a model template to imprint a co-polymer of 4-vinylpyridine (4-VP) and ethyleneglycol dimethacrylate. Equilibrium binding isotherm analysis and isothermal titration microcalorimetry were used to quantify the contribution of enthalpy and entropy to the binding process, identify the nature of the interactions involved and confirm the existence of binding pockets with shape-complementarity to the template. For the binding process of 2,4-D to the imprinted polymer, we postulate three subprocesses: (1) dehydration of the binding pocket and of the 2,4-D, (2) adsorption of 2,4-D, and (3) rearrangement of the water molecules from the dehydration process. We found that binding in aqueous environment was due to the cumulative effect of pi-stacking and electrostatic interactions between the template and the functional monomers. At pH<6, entropy is the dominating driving force, while at pH>6 where the highest difference in binding between the imprinted and a non-imprinted reference polymer was observed, the enthalpy change accounts for most of the binding free energy. The developed microcalorimetric method sheds light on the binding mechanism of analyte molecules with imprinted polymers, in particular if the polymers are used in aqueous solvents.

2,4-Dichlorophenoxyacetic Acid↗

Preparation of sterol-imprinted polymers with the use of 2-(methacryloyloxy)ethyl phosphate.

Steroid-selective polymers were prepared by the molecular imprinting technique, using 2-(methacryloyloxy)ethyl phosphate as functional monomer. The retentivity and selectivity of the obtained imprinted polymers were evaluated by liquid chromatography. The cholesterol-imprinted polymer showed higher affinity for cholesterol than that for cholesterol derivatives. The selectivity of the imprinted polymer was superior to the imprinted polymer prepared with the conventional functional monomer, 2-(trifluoromethyl)acrylic acid. Estradiol was also imprinted and gave similar results, demonstrating that 2-(methacryloyloxy)ethyl phosphate would be suitable for imprinted polymers of cholesterol and related compounds.

Cholesterol↗

Enantiomeric separation using temperature-responsive chiral polymers composed of L-valine diamide derivatives in aqueous liquid chromatography.

This paper describes enantiomer separation by aqueous liquid chromatography using chiral stationary phases (CSPs) in which temperature-responsive polymers derived from acryloyl-L-valine N-methylamide (1) and its N,N-dimethylamide analogue (2) were bound on silica gel supports. The linear polymers composed of monomer 1 and monomer 2 are temperature-responsive in solution and their aggregation and extension states related to water solubility are reversible at particular critical temperatures. During chromatography, enantioselectivity and retentivity for solute enantiomers were controlled by column temperature, which changes the aggregation and extension states of the chiral polymers depending upon their interior hydrophobic nature. Two different types of CSPs were made: a temperature-responsive linear polymer derived from 3-mercaptopropyl silica gel, and another polymer cross-linked with ethylene dimethacrylate from 3-methacryloyloxypropyl silica gel. The former CSP could separate racemic N-(3,5-dinitrobenzoyl(DNB))amino acid isopropyl esters. Retention of the amino acid derivatives was prolonged with an increase in column temperature. Enantioselectivity was also enhanced with temperature increase until the particular critical temperature. The latter, cross-linked CSP could not provide enantioselectivity for the amino acid derivatives in aqueous media, although the chiral valine diamide moieties were effective for enantiomer separation in non-aqueous media. The degree of hydrophobicity and volume of the bonded phase formed by the polymers on the support surface was determined by measuring the fluorescence of pyrene.

Chromatography, Liquid↗

Analysis of organosilicone copolymers by gradient polymer elution chromatography with evaporative light scattering detection.

Organosilicone copolymers have found numerous applications in the cosmetics, detergent and coating industries. Coupling a polar polymer (like polyglycols) to a non-polar silicone gives anchorage and emulsification capabilities to the polymer. When coupling a silicone polymer to a polyglycol, the copolymer formed differs from the starting polymers by a single bond which is often difficult to evidence using spectroscopic techniques such as NMR or infrared, especially when the polymers have a high molecular mass. Gradient polymer elution chromatography (GPEC) coupled to an evaporative light scattering detector was developed for the characterization of copolymers based on their chemical composition distribution. Different block and graft polyglycol-silicone copolymers were successfully characterized by GPEC and residual homopolymers have been easily quantified.

Chromatography, Liquid↗

Selective cell transplantation using bioabsorbable artificial polymers as matrices.

To date, selective cell transplantation has involved injecting cell suspensions into tissues or the vascular system. This study describes attaching cell preparations to bioerodable artificial polymers in cell culture and then implanting this polymer-cell scaffold into animals. Using standard techniques of cell harvest, single cells and clusters of fetal and adult rat and mouse hepatocytes, pancreatic islet cells, and small intestinal cells have been seeded onto biodegradable polymers of polyglactin 910, polyanhydrides, and polyorthoester. Sixty-five fetuses and 14 adult animals served as donors. One hundred fifteen polymer scaffolds were implanted into 70 recipient animals: 66 seeded with hepatocytes; 23 with intestinal cells and clusters; and 26 with pancreatic islet preparations. The cells remained viable in culture, and in the case of fetal intestine and fetal hepatocytes, appeared to proliferate while on the polymer. After four days in culture, the cell-polymer scaffolds were implanted into host animals, either in the omentum, the interscapular fat pad, or the mesentery. In three cases of fetal intestinal implantation coupled with partial hepatectomy, successful engraftment occurred in the omentum, one forming a visible 6.0 mm cyst. Three cases of hepatocyte implantation, one using adult cells and two using fetal cells, have also engrafted, showing viability of hepatocytes, mitotic figures, and vascularization of the cell mass. To date, no pancreatic islets have survived implantation. This method of cell transplantation, which we have termed "chimeric neomorphogenesis," is an alternative to current methods and requires further study.

Animals↗

NMR spectroscopy for determination of cationic polymer concentrations.

Organic polyelectrolytes are utilized extensively in wastewater treatment, but their fate after use is poorly understood. Analytical methods used for polymer determination in less complex systems appear to fail in application to wastewater systems, contributing to the lack of knowledge. Thus, the development of 1H NMR spectroscopy is reported here for specifically quantitating certain cationic flocculant polymers in environmental samples. Proton observe frequencies of 250 or 400 MHz proton were used. A copolymer of acrylamide and acryloyloxyethyltrimethylammonium chloride was used, representative of cationic flocculant polymers possessing quaternary ammonium groups with terminal methyls that provide a sharp singlet at a chemical shift of approximately 3.06 ppm. A strong linear relationship was demonstrated between polymer concentration and either height or area of this peak. Recoveries were up to 96% at higher concentrations (250 mg/L), and were greater than when using viscosity or charge titration methods for polymer determination. Lesser recoveries at lower concentrations (70% at 5 mg/L) were attributed to adsorptive losses. The detection limit of this method was determined to be <0.5 mg/L. Use of the method was exemplified by analysis of anaerobically digested sludges for residual polymer following a range of dosages, showing the resulting isotherm.

Bacteria, Anaerobic↗

Characterization of co-polymers of lactic and glycolic acid for supercritical fluid processing.

Polymers of lactic and glycolic acid are often used for the production of injectible microparticles with controlled drug release. In the variety of processes used for the microparticle formulation, the Aerosol Solvent Extraction System (ASES) is rather special. Microparticle formation and drying take place in one step by precipitating a methylene chloride solution of the polymer in supercritical CO2. This process sets special requirements to the polymers in crystallinity, solubility, and thermal behavior that are best fulfilled by blocked copolymers. This study investigates a number of lactide-co-glycolide polymers with blocked distribution of the co-monomers by NMR spectroscopy and powder diffraction. The molar ratios are determined by 1H-NMR spectroscopy to verify the manufacturer's declarations of the purchased specimens. Additionally, the block length is determined by application of 13C-NMR. Therefore, a method reported in the literature was modified and evaluated in order to calculate the length of lactide and glycolide sequences in the polymer. Furthermore, this study looks at the impact of synthesis conditions on block length and crystallinity, and the impact of the blocking on both, crystallinity and solubility of the polymers.

Biocompatible Materials↗

Tissue ingrowth and degradation of two biodegradable porous polymers with different porosities and pore sizes.

Commonly, spontaneous repair of lesions in the avascular zone of the knee meniscus does not occur. By implanting a porous polymer scaffold in a knee meniscus defect, the lesion is connected with the abundantly vascularized knee capsule and healing can be realized. Ingrowth of fibrovascular tissue and thus healing capacity depended on porosity, pore sizes and compression modulus of the implant. To study the lesion healing potential, two series of porous polyurethanes based on 50/50 epsilon-caprolactone/L-lactide with different porosities and pore sizes were implanted subcutaneously in rats. Also, in vitro degradation of the polymer was evaluated. The porous polymers with the higher porosity, more interconnected macropores, and interconnecting micropores of at least 30 microm showed complete ingrowth of tissue before degradation had started. In implants with the lower macro-porosity and micropores of 10-15 microm degradation of the polymer occurred before ingrowth was completed. Directly after implantation and later during degradation of the polymer, PMN cells infiltrated the implant. In between these phases the foreign body reaction remained restricted to macrophages and giant cells. We can conclude that both foams seemed not suited for implantation in meniscal reconstruction while either full ingrowth of tissue was not realized before polymer degradation started or the compression modulus was too low. Therefore, foams must be developed with a higher compression modulus and more connections with sufficient diameter between the macropores.

Animals↗

Why degradable polymers undergo surface erosion or bulk erosion.

A theoretical model was developed that allows to predict the erosion mechanism of water insoluble biodegradable polymer matrices. The model shows that all degradable polymers can undergo surface erosion or bulk erosion. Which way a polymer matrix erodes after all depends on the diffusivity of water inside the matrix, the degradation rate of the polymer's functional groups and the matrix dimensions. From these parameters the model allows to calculate for an individual polymer matrix a dimensionless 'erosion number' epsilon. The value of epsilon indicates the mode of erosion. Based on epsilon, a critical device dimension Lcritical can be calculated. If a matrix is larger than Lcritical it will undergo surface erosion, if not it will be bulk eroding. Lcritical values for polymers were estimated based on literature data. Polyanhydrides were found to be surface eroding down to a size of approximately Lcritical = 10(-4) m while poly(alpha-hydroxy esters) matrices need to be larger than Lcritical = 10(-1) m to lose their bulk erosion properties. To support our theoretical findings it was shown experimentally that poly(alpha-hydroxy ester) matrices, which are considered classical bulk eroding materials, can also undergo surface erosion.

Biocompatible Materials↗

The use of absorbable co-polymer pads with alginate and cells for articular cartilage repair in rabbits.

PURPOSE: To determine the effect of polyglycolic acid (PGA)-polylactic acid (PLA) co-polymer pads with calcium alginate on chondrogenic gene expression for chondrocytes cultured in vitro. We also evaluated the ability of these absorbable pads with alginate to deliver chondrocytes and influence osteochondral defect repair in vivo in immature rabbit knees. METHODS: Rabbit rib chondrocytes were suspended in calcium alginate and co-polymer pads composed of either 47.5/52.5 PGA-PLA or 90/10 PGA-PLA at two different cell concentrations and cultured in vitro for 1, 3, and 5 days. Analysis was performed using RT-PCR for chondrogenic gene expression of aggrecan, type II collagen, and type I collagen. Cells labeled with a traceable green fluorescent protein (GFP) marker in vitro were suspended within the pads to analyze for dispersion and attachment to the pad. An in vivo study was performed in which full-thickness (3x4mm(2)) osteochondral defects were made in 60 rabbit knees. The study comprised four treatment groups based on the type of implant into the defect (empty, alginate alone, or either type of co-polymer pad) and harvested at either 6 or 12 weeks. Two independent blinded observers analyzed and scored the defects grossly and histologically. RESULTS: In vitro analysis of the chondrocytes after 1, 3, and 5 days in culture showed no statistical differences between the types of PGA/PLA co-polymer pad with regard to expression of aggrecan, type II collagen, or type I collagen. However, although statistically insignificant, the expression of aggrecan and type II collagen was found to be greater than that for type I collagen in both types of pads, confirming the chondrogenic effect of suspension culture for this system. The addition of alginate to polymer pads allowed costal chondrocytes to be implanted in vivo, as evidenced by the attachment of the cells to the fibers and the uniform dispersion of the GFP-labeled cells through the pad as seen on fluorescent microscopy. Histologic results showed improved scores for the 47.5/52.5 PGA-PLA group (21.3) and the 90/10 PGA-PLA group (18.3) when compared to empty (15.3) or alginate alone (15.1) defects at 12 weeks. CONCLUSION: The addition of calcium alginate to the co-polymer pads offers a new approach to deliver cells to an osteochondral defect and may enhance cartilage regeneration. Future application of this model may allow for an arthroscopic delivery system to assist the healing of cartilage defects.

Absorbable Implants↗

Rheological properties of PLGA film-based implants: correlation with polymer degradation and SPf66 antimalaric synthetic peptide release.

This paper reports on the rheological properties of poly(D,L-lactic-co-glycolic acid) polymers (PLGA) dispersions used to form films and of the implants prepared by compression of SPf66 antimalaric peptide between several films, before application and during drug release. 25% PLGA (M(w)=48,000Da) dispersions in dichloromethane showed viscous Newtonian behaviour, being easy flowing and adaptable to the moulds. Evolution of viscoelastic properties, polymer molecular weight, and SPf66 release pattern from the implants immersed in various media was evaluated. Oscillatory shear test showed that freshly prepared implants have an elastic modulus, G', greater than the viscous modulus, G", being both practically independent of angular frequency. After 6 weeks immersion in a pH 7.4 phosphate buffer, G' and G" increased in almost one order of magnitude, despite of a significant polymer degradation. Polymer molecular weight decreased slowly during the first 10 days of immersion (a similar pattern was obtained at pHs 2 and 7.4) and then the degradation process accelerated (degradation index on day 7 equals to 0.89, and on day 14 equals to 16.5). SPf66 release profile followed a pattern similar to that of the polymer degradation index. These observations are explained in terms of changes in polymer structure and conformation that happen in the implant.

Absorbable Implants↗