PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Repeatability and Reproducibility”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

Epitope mapping by photobleaching fluorescence resonance energy transfer measurements using a laser scanning microscope system.

The donor photobleaching method (T. M. Jovin and D. J. Arndt-Jovin. 1989. Annu. Rev. Biophys. Biophys. Chem. 18:271-308.) has been adapted to an ACAS 570 (laser scanning microscope) system to measure fluorescence resonance energy transfer (FRET) on individual human peripheral blood T cells. Photobleaching was completed in approximately 100 ms in our case and it followed double-exponential kinetics. The energy transfer efficiency (E) was approximately 20% between the CD4 epitopes OKT4-FITC and Leu-3a-PE as well as between OKT4E-FITC and OKT4-PE. E was approximately 8% between OKT4-FITC and Leu-4-PE (alpha CD3) and barely detectable (approximately 4%) from OKT4-FITC to Leu-5b-PE (alpha CD2). The E values obtained by the photobleaching method were highly reproducible both in repeated measurement of identical samples and in experiments with different batches of cells and were in agreement with the flow cytometric donor quenching measurements. As expected, E measured between primary and secondary layers of antibodies increased (from approximately 14% to approximately 28%) when F(ab')2 fragments were substituted for whole antibody molecules as the donor. On a T cell line we mapped the distance between the idiotypic determinant of the T cell receptor (TcR) and the Leu-4 epitope of CD3 as proximal as E = 28%, as compared to E = 4% between a framework TcR epitope and Leu-4. In the latter case, however, approximately 40% less Leu-4 was bound suggesting that the antigen binding site of TcR is in close proximity with one of the two CD3 epsilon chains, which hence are not equivalent.

Antibodies, Monoclonal↗

The ETA receptor antagonist, BMS-182874, reduces acute hypoxic pulmonary hypertension in pigs in vivo.

OBJECTIVE: Elevated levels of the potent vasoactive peptide endothelin (ET), have been found in pathophysiological conditions associated with pulmonary hypertension. In this study, we have investigated the effects of the ETA receptor antagonist, BMS-182874, on hypoxic pulmonary hypertension in pigs. METHODS: Pigs were subjected to acute, intermittent 15-min periods of hypoxia (FiO2 0.1). Following a first hypoxia establishing hypoxic baseline values, vehicle or BMS-182874 (10 or 30 mg/kg) was administered i.v. before a second hypoxic period. In separate groups of animals, the effects of the nitric oxide synthase inhibitor N omega-nitro-L-arginine (L-NNA) in combination with BMS-182874 (10 mg) during repeated hypoxia were investigated. The ET-1-blocking properties of BMS-182874 were studied in vivo by infusion of ET-1 during normoxia and in vitro using isolated porcine pulmonary arteries. RESULTS: The hypoxia-evoked increase in mean pulmonary artery pressure was reduced by administration of BMS-182874 (10 mg/kg i.v.; from 42 +/- 8 to 34 +/- 4 mmHg, P < 0.05 and 30 mg/kg i.v.; from 38 +/- 4 to 30 +/- 5 mmHg, P < 0.05). In addition, BMS-182874 at 30 mg/kg reduced the pulmonary vascular resistance during hypoxia (from 7.4 +/- 1.5 to 5.3 +/- 1.1 mmHg.min.l-1 P < 0.05). The hemodynamic response to repeated hypoxia was reproducible in control animals and unaffected by the cyclo-oxygenase inhibitor diclophenac (3 mg/kg). Infusion of L-NNA alone resulted in an augmented pulmonary vasoconstriction during hypoxia; pulmonary arterial pressure from 35 +/- 6 to 43 +/- 9 mmHg; P < 0.05 and vascular resistance from 7.2 +/- 1.1 to 9.9 +/- 1.8 mmHg.min.l-1; P < 0.05. L-NNA in combination with BMS-182874 (10 mg/kg) resulted in a hypoxic pulmonary vasoconstriction of similar magnitude as hypoxic baseline. In addition, BMS-182874 reduced the hemodynamic response to ET-1 in normoxic pigs and competitively antagonized the vasoconstrictor effect of ET-1 in isolated porcine pulmonary arteries. CONCLUSIONS: The non-peptide, selective ETA receptor antagonist, BMS-182874, reduces hypoxic pulmonary vasoconstriction in pigs. The reduction in pulmonary vascular response to hypoxia following BMS-182874 is at least partly independent of nitric oxide.

Animals↗

Optimization of solid-phase microextraction conditions using a response surface methodology to determine organochlorine pesticides in water by gas chromatography and electron-capture detection.

A response surface methodology was applied to optimise the solid-phase microextraction (SPME) conditions using a polyacrylate-coated fiber to determine thirteen organochlorine pesticides from water. Analyses were performed using gas chromatography-electron-capture detection. Variables affecting absorption in both the headspace and immersion extraction were optimised by using a response surface generated with a Doehlert design, and the results were compared. The immersion SPME method was selected since higher recoveries were obtained for most of the compounds studied. The method developed was applied to the analysis of tap and Ebro river water samples. The linear range of most pesticides for real samples was found to be between 0.001 and 2.5 micrograms l-1 and the limits of detection were between 0.15 and 0.35 ng l-1. The repeatability and the reproducibility between days of the method (n = 6), expressed as relative standard deviation, for tap water spiked at a level of 1 ng l-1 were between 5.7 and 25.6% and between 7.6 and 26.5%, respectively.

Chromatography, Gas↗

Drusen measurement from fundus photographs using computer image analysis.

Drusen are yellowish deposits at the level of the retinal pigment epithelium and are frequently associated with age-related maculopathy (ARM). Drusen often change in size and number over time and may be followed by atrophic or exudative macular degeneration. A quantitative method to measure the development of drusen is needed for controlled studies of the natural history, prognosis, and treatment of ARM. An objective method is described using computer image analysis of fundus photographs for the detection and measurement of drusen. This technique enables us to measure both the area of drusen in the macula and the changes in the drusen pattern over time. Evaluation of repeated photographs showed reproducibility of 6.1%, whereas the reproducibility of processing photographic duplicates was 2.3%. Digitization with a high-quality linear array solid state camera did not change reproducibility significantly.

Fundus Oculi↗

Interlaboratory random amplified polymorphic DNA typing of Yersinia enterocolitica and Y. enterocolitica-like bacteria.

A random amplified polymorphic DNA (RAPD) protocol was developed for interlaboratory use to discriminate food-borne Yersinia enterocolitica O:3 from other serogroups of Y. enterocolitica and from Y. enterocolitica-like species. Factors that were studied regarding the RAPD performance were choice of primers and concentration of PCR reagents (template DNA, MgCl(2), primer and Taq DNA polymerase). A factorial design experiment was performed to identify the optimal concentrations of the PCR reagents. The experiment showed that the concentration of the PCR reagents tested significantly affected the number of distinct RAPD products. The RAPD protocol developed was evaluated regarding its discrimination ability using 70 different Yersinia strains. Cluster analysis of the RAPD patterns obtained revealed three main groups representing (i) Y. pseudotuberculosis, (ii) Y. enterocolitica and (iii) Y. kristensenii, Y. frederiksenii, Y. intermedia and Y. ruckeri. Within the Y. enterocolitica group, the European serovar (O:3) and the North American serovar (O:8) could be clearly separated from each other. All Y. enterocolitica O:3 strains were found in one cluster which could be further divided into two subclusters, representing the geographical origin of the isolates. Thus, one of the subclusters contained Y. enterocolitica O:3 strains originating from Sweden, Finland and Norway, while Danish and English O:3 strains were found in another subcluster together with O:9 and O:5,27 strains. The repeatability (intralaboratory) and reproducibility (interlaboratory) of the RAPD protocol were tested using 15 Yersinia strains representing different RAPD patterns. The intralaboratory and the interlaboratory studies gave similarity coefficients of the same magnitude (generally >70%) for the individual strains. In the present study, it was shown that interreproducible RAPD results could be achieved by appropriate optimisation of the RAPD protocol. Furthermore, the study reflects the heterogeneous genetic diversity of the Y. enterocolitica species.

Cluster Analysis↗

Hydrolytic degradation of nitrendipine and nisoldipine.

The development of a new HPLC-UV diode array procedure applied to follow the hydrolytic degradation of two well-known 4-nitrophenyl-1,4-dihydropyridine derivatives, nitrendipine and nisoldipine is reported. Hydrolysis of each drug were carried out in ethanol/Britton-Robinson buffer at different pHs, stored into amber vials at controlled temperatures of 40, 60 and 80 degrees C and periodically sampled and assayed by HPLC. Nitrendipine degradation in different parenteral solutions was also evaluated. The HPLC procedure exhibited an adequate selectivity, repeatability (<1%) and reproducibility (<2%). The recoveries were higher than 98% with CV of 1.13 and 1.54% for nitrendipine and nisoldipine, respectively. A significant degradation was observed at alkaline pH (>pH 8) with a first order kinetic for both drugs. At pH 12, 80 degrees C, k values of 3.56x10(-2) x h(-1) and 2.22x10(-2) for nitrendipine and nisoldipine, respectively were obtained. Also, activation energies of 16.8 and 14.7 kcal x mol(-1) for nitrendipine and nisoldipine, respectively, were calculated. Furthermore, from the results obtained from hydrolytic degradation in different solutions for parenteral use, we can affirm that solutions significantly increased the degradation of nitrendipine. In conclusion, the HPLC proposed procedure exhibited adequate analytical requirements to be applied to the hydrolytic degradation studies of nitrendipine and nisoldipine. Furthermore, all tested parenteral solutions significantly increased the hydrolytic degradation of nitrendipine, the composition of solution being a relevant factor.

Buffers↗

Calibration and characterization of a digital X-ray fluorescence bone lead system.

Five different combinations of digital shaping parameters were tested for a newly assembled. 109Cd source, K X-ray fluorescence bone lead system. System calibration results are presented, along with analyses of measurement uncertainty and reproducibility obtained from repeat measurements of a bone phantom and a human tibia. Digital shaping parameters of 2.4 micros for a rise time/fall time and 1.2 micros for a flat top width were identified as superior. The digital system provided significant improvements in overall measurement precision, with gains of at least 25-35% over conventional system results.

Bone and Bones↗

Furosine as indicator of maillard reaction in jams and fruit-based infant foods.

To investigate the presence of furosine in commercial samples of jams and fruit-based infant foods a simple method by ion-pair reversed-phase liquid chromatography is described. The yield of furosine during the hydrolysis with hydrochloric acid was optimized. The reproducibility in the repeatability and recovery of the method, expressed in relative standard deviation percentages, proved to be in the ranges of 4.1-8.3% and 1.0-4.4%, respectively. The recovery percentages of furosine varied between 86.7 and 95.3%. The obtained results support the suitability of the method. Furosine was detected in all studied samples. Although a high variability in the content of furosine was noticed, in general terms, the lowest levels of furosine were observed in samples of fruit-based infant foods and the highest were observed in jams of more than 60% sugar. These results could be due to different heat treatment, storage conditions, and/or differences in the values of water activity (a(w)) and amounts of sugar. The results obtained in the present paper point out the usefulness of furosine as an indicator of Maillard reaction for jams and fruit-based infant foods.

Chromatography, High Pressure Liquid↗

Development of a seven-target multiplex PCR for the simultaneous detection of transgenic soybean and maize in feeds and foods.

The detection of genetically modified organisms (GMOs) in food and feed is an important issue for all the subjects involved in raw material control, food industry, and distribution. Because the number of GMOs authorized in the EU increased during the past few years, there is a need for methods that allow a rapid screening of products. In this paper, we propose a method for the simultaneous detection of four transgenic maize (MON810, Bt11, Bt 176, and GA21) and one transgenic soybean (Roundup Ready), which allows routine control analyses to be sped up. DNA was extracted either from maize and soybean seeds and leaves or reference materials, and the recombinant DNA target sequences were detected with 7 primer pairs, accurately designed to be highly specific for each investigated transgene. Cross and negative controls were performed to ensure the specificity of each primer pair. The method was validated on an interlaboratory ring test and good analytical parameters were obtained (LOD = 0.25%, Repeatability, (r) = 1; Reproducibility, (R) = 0.9). The method was then applied to a model biscuit made of transgenic materials baked for the purpose and to real samples such as feed and foodstuffs. On account of the high recognition specificity and the good detection limits, this multiplex PCR represents a fast and reliable screening method directly applicable in all the laboratories involved in raw material and food control.

Animal Feed↗

Stereotactic magnetic resonance guidance for anatomically targeted ablations of the fossa ovalis and the left atrium.

INTRODUCTION: Targets for radiofrequency ablation (RFA) of atrial fibrillation are increasingly being selected based on anatomic considerations. Because fluoroscopy provides only limited information about the relationship between catheter positions and cardiac structures, we evaluated whether stereotactic catheter guidance might facilitate anatomical catheter navigation and RFA to the great vessels, the fossa ovalis and the left atrium (LA). METHODS AND RESULTS: An electromagnetic catheter's position system was superimposed on three-dimensional (3D) MR images using fiducial markers. This allowed the dynamic display of the catheter position on the true anatomy of previously acquired MRI in real-time. To assess the reproducibility of RFA, repeat ablations were created at the identical anatomic site in the inferior vena cava (IVC) in 5 swine. Average distance of the repeated ablations was 4.4 +/- 2.4 mm.In five swine the catheter was anatomically guided with the MRI to the fossa ovalis and a single RFA was performed. On the pathological specimen all ablation sites were located within the fossa ovalis with an average distance of 3.9 +/- 2.1 mm from its center. In two of the experiments the ablation catheter was passed into the left atrium and anatomically targeted ablation performed in the lateral wall of the left atrial appendage. Catheter location and ablation site were confirmed by autopsy and histology. CONCLUSION: Real-time display of the catheter position on 3D-MRI allows anatomically targeted catheter navigation and RFA in the IVC, the fossa ovalis, and the left atrium. This may facilitate anatomically based interventions like septal puncture or pulmonary vein ablation and decrease fluoroscopy times.

Animals↗

Pseudomonas putida B2: a tod-lux bioluminescent reporter for toluene and trichloroethylene co-metabolism.

A tod-lux transcriptional fusion bioluminescent reporter strain, Pseudomonas putida B2, was developed to permit on-line analysis of trichloroethylene (TCE) transformation by toluene dioxygenase (todC1C2BA) in Pseudomonas putida F1. Strain B2 was exposed to toluene in growing and resting cell bioluminescence assays. The growing cells showed a direct correlation between bioluminescence and toluene concentration, while resting cells showed reproducible bioluminescence with repeated toluene exposures. In addition, P. putida B2 was encapsulated in alginate beads and used in a packed bed flow-through differential volume reactor. The TCE feed into the differential volume reactor was constant at 20 mg L-1 and toluene was pulsed in square-wave perturbations at 10 mg L-1. The system showed a direct correlation between the expression of the tod operon (as monitored by light output) and the co-metabolism of TCE. Approximately 20% of the TCE and 50% of the toluene was removed at a flow rate of 0.4 ml min-1. This approach allowed the on-line monitoring of tod gene expression and its relation to TCE biotransformation.

Alginates↗

A diagnostic biochip for the comprehensive analysis of MLL translocations in acute leukemia.

Reciprocal rearrangements of the MLL gene are among the most common chromosomal abnormalities in both Acute Lymphoblastic and Myeloid Leukemia. The MLL gene, located on the 11q23 chromosomal band, is involved in more than 40 recurrent translocations. In the present study, we describe the development and validation of a biochip-based assay designed to provide a comprehensive molecular analysis of MLL rearrangements when used in a standard clinical pathology laboratory. A retrospective blind study was run with cell lines (n=5), and MLL positive and negative patient samples (n=31), to evaluate assay performance. The limits of detection determined on cell line data were 10(-1), and the precision studies yielded 100% repeatability and 98% reproducibility. The study shows that the device can detect frequent (AF4, AF6, AF10, ELL or ENL) as well as rare partner genes (AF17, MSF). The identified fusion transcripts can then be used as molecular phenotypic markers of disease for the precise evaluation of minimal residual disease by RQ-PCR. This biochip-based molecular diagnostic tool allows, in a single experiment, rapid and accurate identification of MLL gene rearrangements among 32 different fusion gene (FG) partners, precise breakpoint positioning and comprehensive screening of all currently characterized MLL FGs.

Acute Disease↗

Polymer agglutination-based piezoelectric immunoassay for the determination of complement III.

A piezoelectric immunoassay technique, which is based on the detection of agglutination of antibody- or antigen-bearing polymer by an immunoreaction using a piezoelectric quartz crystal, has been developed for the determination of complement III (C3). Anti-C3 antibodies were physically adsorbed onto the carboxymethyl cellulose polymer by hydrogen bonds. The agglutination of the (anti-C3 antibody)-bearing polymer by immunoreaction caused a viscosity change of the solution, which could be monitored by a piezoelectric quartz crystal. The effect of experimental conditions such as the polymer concentration, the antibody dilution ratio and the reaction temperature on the frequency response were investigated. The linear ranges for C3 concentration determined by the end-point method and the initial rate method were 22.0-43.2 micrograms ml-1 and 22.0-49.1 micrograms ml-1, respectively. Other antigens presenting in serum did not interfere with the determination of C3. Analytical results of ten clinical specimens obtained using the developed technique were in satisfactory agreement with those given by the rate diffusion turbidimetry. With a simple regeneration method devised, the crystal can be used repeatedly with acceptable reproducibility.

Complement C3↗

Chemical synthesis and microvascular effects of new nitric oxide donors in humans.

Nitric oxide (NO) is produced continuously from the endothelium and plays a pivotal role in the control of vascular tone. Many of the current therapeutic agents that increase blood flow through production of NO have to be taken orally and can produce significant adverse side effects. We now report on some novel NO-donor drugs, based on thiosugars that generate NO spontaneously. From the range of compounds synthesized, D-SNAG ( S -nitroso-1-thio-2,3,4,6-tetra- O -acetyl-beta-D-glucopyranose) was as effective a vasodilator as any other and, as it was the easiest to synthesize, we undertook a more detailed evaluation to understand the chemistry and mode of action of its vasodilator effect. From the chemical kinetic data, we found that NO release occurred predominantly by thermal decomposition, with a 20-fold increase in decomposition rate between 19 and 37 degrees C. In the forearm of eight normal male subjects, we found that D-SNAG produced a significant dose-dependent vasodilator effect ( P =0.001) with good reproducibility (19%) on repeated testing. We propose that delivery of NO from D-SNAG to the forearm skin microvessels most probably occurs by diffusion across the epidermis. Since such compounds release NO in a non-enzymic manner following topical application, they might produce an attractive therapeutic source of localized NO delivery without inducing systemic side effects.

Adult↗

A collaborative study of a method for enumeration of probiotic enterococci in animal feed.

AIMS: Validation of an enumeration method to be used as an official control method in the framework of Council Directive 70/524/EEC for probiotic enterococci used as feed additives. METHODS AND RESULTS: Twenty laboratories in 12 European countries carried out a collaborative study. A plate count method using bile esculin azide (BEA) agar was used. Precision data in terms of repeatability (r) and reproducibility (R) of the method using different feeding stuffs and three inoculation levels were determined. Enterococci were present in the samples as a single component or in mixtures with other probiotic feed additives. The enumeration of enterococci on BEA agar showed a relative standard deviation (RSD)r of 1.5-3.6% and an RSD(R) between 2.9 and 7.4%. BEA agar was selective for enterococci in the presence of other probiotic micro-organisms such as pediococci, lactobacilli and yeast. CONCLUSIONS: For routine analysis of viable enterococci concentrations in feeding stuffs, the use of BEA is recommended. This methodology is not applicable for mineral feeds. SIGNIFICANCE AND IMPACT OF THE STUDY: An official control method for enumeration of authorized probiotic enterococci in feeding stuffs was validated. The results are intended for consideration for adoption as CEN and ISO standards.

Animal Feed↗

Validation of an official control method for enumeration of authorised probiotic yeast in animal feed.

An official control method in the framework of Council Directive 70/524/EEC for probiotic yeast used as feed additives was validated in a collaborative study by twenty laboratories in 12 European Countries. A pour plate method following ISO 7954 using chloramphenicol glucose yeast extract (CGYE) and a plate count method using CHROMagar Candida were used. Precision data in terms of repeatability (r) and reproducibility (R) of the method using different feeding stuffs and three inoculation levels were determined. Yeast was present in the samples in mixtures with other probiotic feed additives at a lower, a higher concentration or not present. The enumeration of yeast on CGYE agar showed for the lower and higher concentration a RSD(r) of 2.4-4.9% and a RSD(R) of 7.7-8%, respectively and was preferred by the majority of labs. CHROMagar Candida had a RSD(r) of 1.9-2.8% and a RSD(R) of 1.9-5.9%. For routine analysis the use of the pour plate technique is recommended. CHROMagar Candida can be used for confirmation of the species Saccharomyces cerevisiae. The methods are not recommended for mineral feeds. The results from this study are intended for consideration for adoption as CEN and ISO standards.

Animal Feed↗

Determination of ethylenethiourea (ETU) and propylenethiourea (PTU) in foods by high performance liquid chromatography-atmospheric pressure chemical ionisation-medium-resolution mass spectrometry.

A robust and sensitive method for the determination of ethylenethiourea (ETU) and iso-propylenethiourea (i-PTU) in foods is reported. ETU and i-PTU were extracted by blending with dichloromethane (DCM) in the presence of sodium sulphate, sodium carbonate, thiourea and ascorbic acid. 2H4-ETU and n-PTU were used as internal standards. After filtration the DCM was removed by rotary evaporation and the extract re-dissolved in water before analysis by reversed-phase liquid chromatography with detection by atmospheric pressure chemical ionization-mass spectrometry using a double focusing mass spectrometer at a resolution of 5000. Mean recoveries of ETU and i-PTU from fruit-based, cereal-based and meat-based infant foods, potato chips and tinned potatos at 0.01 mg kg(-1) and from pizza and yoghurt at 0.02-0.1 mg kg(-1) were 95% and 97% respectively. Precision, including both repeatability and internal reproducibility, was in the range of 3.1-13.1%.

Chromatography, High Pressure Liquid↗

EC-collaborative study on the determination of aflatoxin B1 in animal feeding stuffs.

A collaborative study was conducted to test a method, proposed in the European Community (EC) as a candidate-official method for the determination of aflatoxin B1 in compounded feeding stuffs. The study was undertaken on behalf of the European Commission's Community Bureau of Reference (BCR). It involved 25 laboratories from 11 EC countries. The method, based on chloroform extraction and Sep-Pak Florisil and C18 cartridge clean-up, offered either reverse-phase high performance liquid chromatography (HPLC) with iodine post-column derivatization, or two-dimensional thin-layer chromatography (TLC) as determinative steps. In the study, 22 laboratories applied HPLC, three laboratories applied TLC. The study involved six unknown samples. These consisted of blind duplicate samples of compounded feeding stuff, with target concentrations of aflatoxin B1 at less than 2, 8 and and 14 micrograms/kg. Statistical analysis of the HPLC data was carried out according to ISO 5725. For the less than 2 micrograms/kg sample, all reported aflatoxin concentrations were less than 2 micrograms/kg. At the 8 and 14 micrograms/kg level (pooled), repeatability (r) and reproducibility (R), expressed as ratios, were 1.4 and 1.7 respectively, and within-laboratory and between-laboratory coefficients of variation were 11% and 18% respectively. The study revealed that admittance of daylight in the laboratory caused losses of aflatoxin B1 and must be avoided. New glassware coming into contact with aqueous solutions containing aflatoxin B1 was found to be a potential cause of loss of aflatoxin B1. The method has been recommended to the European Commission to be considered for adoption in EC regulations.

Aflatoxin B1↗