PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Telemetry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

The diving behaviour of green turtles undertaking oceanic migration to and from Ascension Island: dive durations, dive profiles and depth distribution.

Satellite telemetry was used to record the submergence duration of green turtles (Chelonia mydas) as they migrated from Ascension Island to Brazil (N=12 individuals) while time/depth recorders (TDRs) were used to examine the depth distribution and dive profiles of individuals returning to Ascension Island to nest after experimental displacement (N=5 individuals). Satellite telemetry revealed that most submergences were short (<5 min) but that some submergences were longer (>20 min), particularly at night. TDRs revealed that much of the time was spent conducting short (2-4 min), shallow (approximately 0.9-1.5 m) dives, consistent with predictions for optimisation of near-surface travelling, while long (typically 20-30 min), deep (typically 10-20 m) dives had a distinctive profile found in other marine reptiles. These results suggest that green turtles crossing the Atlantic do not behave invariantly, but instead alternate between periods of travelling just beneath the surface and diving deeper. These deep dives may have evolved to reduce silhouetting against the surface, which would make turtles more susceptible to visual predators such as large sharks.

Animal Migration↗

QT PRODACT: in vivo QT assay with a conscious monkey for assessment of the potential for drug-induced QT interval prolongation.

In safety pharmacology studies, the effects on the QT interval of electrocardiograms are routinely assessed using a telemetry system in cynomolgus monkeys. However, there is a lack of integrated databases concerning in vivo QT assays in conscious monkeys. As part of QT Interval Prolongation: Project for Database Construction (QT PRODACT), the present study examined 10 positive compounds with the potential to prolong the QT interval and 6 negative compounds considered to have no such effect on humans. The experiments were conducted at 7 facilities in accordance with a standard protocol established by QT PRODACT. The vehicle or 3 doses of each test compound were administered orally to male cynomolgus monkeys (n=3-4), and telemetry signals were recorded for 24 h. None of the negative compounds prolonged the corrected QT using Bazett's formula (QTcB) interval. On the other hand, almost all of the positive compounds prolonged the QTcB interval, but haloperidol, terfenadine, and thioridazine did not. The failure to detect the QTcB interval prolongation appeared to be attributable for the differences in metabolism between species and/or disagreement with Bazett's formula for tachycardia. In the cynomolgus monkeys, astemizole induced Torsade de Pointes and cisapride caused tachyarrhythmia at lower plasma concentrations than those observed in humans and dogs. These results suggest that in vivo QT assays in conscious monkeys represent a useful model for assessing the risks of drug-induced QT interval prolongation.

Animals↗

The telemetric monitoring of heart rate, locomotor activity, and body temperature in mice and voles (Microtus arvalis) during ambient temperature changes.

We have studied the physiological and behavioural responses in small rodents to ambient alterations. For this purpose, voles and mice were exposed to relatively low (12 degrees C) and high (35 degrees C) ambient temperatures, and heart rate (HR), locomotor activity (LA) and body temperature (BT) were recorded using telemetry system. The control HR (at 24 degrees C) of voles was lower than that of mice. The 'heat exposure' decreased HR to 85.0 +/- 3.3% in voles, and to 78.0 +/- 3.2% in mice compared with the mean HR of the same time in the control day. The 'cold exposure' increased the HR to 131.9 +/- 8.8% in voles, and 119 +/- 10.9% in mice. The decreasing rate of HR in heat exposure was smaller in voles than mice, and in cold exposure the increased rate was larger in voles than mice. Cold exposure decreased BT in both species; 96.1 +/- 0.5% in voles and 93.7 +/- 1.0% in mice. The LA was not changed significantly by heat exposure in either species, but was partially increased by cold exposure. These results demonstrate that telemetry was helpful for qualitative and quantitative behavioural studies in small rodents, and confirmed that the physiological and behavioural responses to ambient temperature changes differed between these animals.

Animals↗

Variations in hemodynamic parameters and ECG in healthy, conscious, freely moving telemetrized beagle dogs.

Interpretation of the dynamic cardiovascular parameters on safety pharmacology studies is a challenging process; sometimes, it is difficult to separate normal physiological variations from the effects of the test drug. Data from healthy control Beagle dogs (41 males and 25 females) implanted with telemetry transmitters (DSI, St. Paul, MN) from 34 studies performed from 2003 to 2005 were analyzed. Telemetry data were collected for a 30-s period every 10 min for 24 h after sham dosing. One-hour averages were analyzed. Prior to dosing, heart rate (HR) was 95.6 +/- 26.6 bpm; mean, systolic, and diastolic blood pressure (BP) were 105.3 +/- 12.7, 142.5 +/- 5.3, and 84.7 +/- 11.1 mmHg, respectively. PR, QRS, QT, and corrected (Van de Water) QT intervals were 121 +/- 13, 33 +/- 3, 217 +/- 23, and 245 +/- 18 ms, respectively. Seasonal and slight diurnal patterns were noticed only in HR; BP and body temperature were more stable. PR and QT intervals were inversely related to HR; in addition, the duration of PR was influenced by the light cycle. A comparison of three QT correction formulas demonstrated that Van de Water's formula provided the optimal results in Beagle dogs over a wide range of HR.

Animals↗

Transmitting patient and device data via GSM--central management for decentral mobile medical devices.

Equipping medical devices with long range telemetry opens completely new possibilities for emergency response, home care and remote diagnosis. Mobile communications nowadays seem to be a generally accepted part of our modern world, but bridging the gap between new (consumer-) technologies and medical devices still is a challenge today. Providing a telemetry link (GSM) is just the trivial part--ensuring security, reliability and service management are the more critical tasks that need to be addressed. Therefore, a complete system concept consists of an automatic fleet management (e.g. periodic device-initiated service calls) as well as customer relationship management (CRM), including technical service and a trouble-ticket system.

Artificial Intelligence↗

Surgical implantation and evaluation of heart rate transmitters in captive bighorn sheep.

A surgical approach was developed for implantation of transmitters to monitor heart rate of bighorn sheep (Ovis canadensis) with an objective of discrete long-term, long-range data collection. We surgically implanted Telonics model HR400 transmitters on the dorsolateral thorax of 15 captive adult bighorn sheep ewes in April-May and October-November 1995. No complications or marked impairment of function were associated with the surgery; however, a transmitter was passively expelled from one ewe 19.5 mo post-implantation. Twelve of 15 transmitters remained functional > or = 1 yr, while three failed 3.5 to 4.5 mo following implantation. Heart rate data collected from the transmitters using a Lotek SRX_400 telemetry receiver/datalogger equipped with W9 EVENT_LOG accurately reflected heart rate as measured with electrocardiogram tracings. Line of sight signal range was at least 800 m in 95% (37/39) of collections made from standing ewes, while data could be collected reliably (74%; 29/39) to 600 m from bedded ewes. When a reliable long-lasting inconspicuous telemetry system is required, we believe that this approach holds promise for success in free-ranging as well as captive ungulates.

Animals↗

Teletransmission of physiological data.

The routine procedure of EEG recording is recalled to show the advantages of telemetric assessment of this parameter. The procedure for EEG telemetry is shown under different circumstances, e.g., by transmission with the aid of the 'Community Antenna System' of a hospital. Finally, a 16-channel telemetry system, using pulse width modulation is described.

Electroencephalography↗

Physiologic monitoring systems.

Physiologic monitoring systems monitor vital physiologic parameters so that clinicians can be informed of changes in a patient's condition. They typically consist of several distinct components, including a central station, bedside monitors, and ambulatory telemetry transmitters and receivers. We previously evaluated physiologic monitoring systems in our January-February 1999 issue (Health Devices 28[1-2]). For this update, we have tested systems from two additional suppliers, using the same criteria and test methods that we used for the eight systems in the original study. As in the earlier Evaluation, we have examined how each system functions as a whole, rather than focusing on the performance of individual components. We judged the systems primarily on adaptability, alarm implementation, and human factors design. In the Conclusions, we compare all 10 units evaluated to date. We also provide updated product information for the systems evaluated in our original study; in some cases, the changes that have been made to those systems have caused us to revise our ratings. We rated all the systems based on their capabilities for each of six applications: (1) critical care unit, (2) emergency department, (3) intermediate care unit and general medical/surgical floor, (4) operating room, (5) postanesthesia care unit, and (6) transport. As in our earlier study, we have determined that most of the evaluated systems have drawbacks for one or more of the evaluated applications. In our January-February 1999 Evaluation of physiologic monitoring systems (Health Devices 28[1-2]), we discussed the issues surrounding the purchase and use of these systems. In this introduction, we recap the most significant points from that discussion, provide some new information about ambulatory telemetry and wireless networks, and briefly describe the components of this Update Evaluation.

Equipment Design↗

Telemetric evaluation of body temperature and physical activity as predictors of mortality in a murine model of staphylococcal enterotoxic shock.

BACKGROUND AND PURPOSE: Hypothermia and death are used as experimental markers in murine models of staphylococcal enterotoxic shock. This study determined whether body temperature and physical activity, monitored telemetrically, could predict impending death and provide an earlier, more humane experimental endpoint. METHODS: The study consisted of two iterations (experiments 1 and 2) to determine reproducibility of the model. Each experiment consisted of 24 BALB/c mice surgically implanted with intra-abdominal telemetry transmitters and then injected intraperitoneally with sublethal or lethal doses of staphylococcal enterotoxin B (SEB) and/or lipopolysaccharide (LPS). Core body temperature and physical activity were continuously monitored in all mice for 10 days before, and 5 days after, injections. Additionally, in experiment 2, subcutaneous temperatures were compared with core body temperatures obtained by telemetry. RESULTS: Body temperature and physical activity were reduced in mice after administration of SEB and LPS, or LPS alone, but not SEB only. There was a significant (P < 0.05) correlation between mortality and body temperature (P = 0.0077), but not physical activity (P = 0.97). CONCLUSION: Body temperature proved to be an early indicator of mortality in this murine model of staphylococcal enterotoxic shock.

Animals↗

Applications of space communications technology to critical human needs: rescue, disaster relief, and remote medical assistance.

The applications of space communications technology to various critical human needs are discussed. Satellite communications, telemetry, and biotelemetry have provided timely and crucial communications capabilities over remote distances. The use of satellite/beacon systems have been used for disaster relief as well as search and rescue operations. The combination of telemetry and electronic medical systems (telemedicine) have augmented existing health care delivery and have provided consultation links between remotely located health care specialists working with patients and physicians at a central location. This has been expanded into networks to respond to victims of disasters in need of critical medical assistance with the hope that with further work, telemedicine may become available to all nations through an international network.

Communication↗

A repeater type biotelemetry system for use on wild big game animals.

A repeater type telemetry system was developed and field tested on a wild elk near laramie, Wyoming, in the summer of 1973. The telemetry system consisted of the following: (a) a heat flow rate sensing implanted transmitter, (b) a repeater type neck collar and (c) a portable receiving station consisting of a receiver, decoding circuitry and analog chart recorder. The transmitter in (a) produced relatively low frequency rf pulses whose repetition rate was directly proportional to heat flow rate through the hide of the animal. In (b), the pulses from the implant are sensed and retransmitted using a relatively high power, high frequency transmitter. A second rf pulse was generated whose pulse spacing was related to animal activity. Details of circuit design and performance are given. Field experience has shown that this method is extremely useful for the monitoring of biological data from secretive big game animals such as elk.

Animals↗

Telemetric recording of sleep and home cage activity in mice.

STUDY OBJECTIVES: This study assessed differences in spontaneous sleep and locomotor activity in inbred and hybrid mouse strains and evaluated telemetry for recording sleep in mice. DESIGN: Uninterrupted recordings of sleep and home cage activity were obtained in four mouse strains. Pre-operative and post-operative home cage activity was obtained in two strains. SETTINGS: N/A PARTICIPANTS: The subjects were mice of three inbred (C57BL/6J (B6), n=25; BALB/cJ (C), n=24; DBA/2J (D2), n=30) strains and one hybrid (CB6F1/J (CB6: C x B6), n=19) strain. INTERVENTIONS: Electroencephalogram (EEG) and activity were recorded by telemetry, and behavioral states were visually scored based on EEG and activity records. Home cage activity was determined utilizing photobeam interruptions. MEASUREMENTS AND RESULTS: 1) Among the three inbred strains: C mice had the least sleep and the greatest amount of activity; D2 mice exhibited the least non-rapid-eye-movement (NREM) sleep, the longest average NREM-bout length, and the greatest diurnal ratio of sleep and were the most inactive; B6 mice had the most sleep and an intermediate activity level; no differences among inbred strains were observed in total REM. The CB6 mice exhibited intermediate levels of total sleep and activity and had greater amounts of REM compared to its parental strains. 2) Total operative mortality was 9.3%, with all deaths occurring within 3 to 9 days after the operation; significant reductions in activity were observed after the operation. CONCLUSION: Differences in spontaneous sleep and activity exist among inbred and hybrid mouse strains. Accurate determination of sleep states in mice can be achieved with telemetrically recorded EEG and activity.

Animals↗

[Possibilities for the use of a wirelsss telemetric technic in electroencephalography].

Telemetry is the transmission of the test data of moving object, with a distinction being made between wireless and wire-connected telemetry. The applicability of this technique is examined on the basis of experience gained, and data gathered from books and articles on the subject. Biotelemetry constitutes a new development in technology and methodology which, if critically applied in meeting the various challenges confronting the specialist, can render useful service in the field of electroencephalography.

Aerospace Medicine↗

Correlation between NRT measurement and behavioural levels in patients with the Nucleus 24 cochlear implant.

Aim of this study was to determine the relationship between the electrically evoked whole nerve action potential (EAP) and T- and C-level for subjects using the Nucleus 24 cochlear implant system. EAP thresholds were measured using the Neural Response Telemetry system of the Nucleus 24 device. Twelve Nucleus 24 cochlear implant users took part in this study. EAP thresholds were compared with the behavioural measures of T- and C-levels used to programme the speech processor. The EAP and the T- and C-levels were obtained, on the same day, 1 month after cochlear implant activation. EAP thresholds were seen to fall between the T- and C-level. On average, EAP thresholds fell at 72% of the map dynamic range. The majority of absent answers were found in three of the 12 patients, and out of a total of 195 activated electrodes an EAP was recorded in 169. These data show that Neural Response Telemetry is a valuable clinical tool in the Nucleus cochlear implant system, providing information concerning integrity of the implant and status of the peripheral auditory nerves.

Adolescent↗

Comparison of body surface temperature measurement and conventional methods for measuring temperature in the mouse.

Temperature is a valuable parameter used to judge wellness of animals in a research setting; therefore, reliable, noninvasive, and inexpensive methods for monitoring temperature are becoming a necessity in research laboratories. A new method for obtaining temperature in mice, the measurement of body surface temperature via an external probe, was compared to two more common methods, the rectal probe and telemetry. The comparisons of the temperature measuring devices were performed in mice made hypothermic via prolonged anesthesia and in mice made hyperthermic by injection of endotoxin. The results demonstrated good correlation between the surface temperature measurements and the temperatures obtained by both telemetry and the rectal probe. The correlations were particularly significant when core body temperatures were below normal. In addition, the surface probe compared favorably with the other methods with regard to animal stress, observed complications, and initial cost. These results suggest that the surface probe could provide an efficient means for obtaining valuable physiological data and determining humane endpoints.

Animals↗

Video-EEG recording: a four-year clinical audit.

In the setting of a regional neurological unit without an epilepsy surgery service as in our case, video-EEG telemetry is undertaken for three main reasons; to investigate whether frequent paroxysmal events represent seizures when there is clinical doubt, to attempt anatomical localization of partial seizures when standard EEG is unhelpful, and to attempt to confirm that seizures are non-epileptic when this is suspected. A clinical audit of all telemetry performed over a four-year period was carried out, in order to determine the clinical utility of this aspect of the service and to determine means of improving effectiveness in the unit. Analysis of the data showed a high rate of negative studies with no attacks recorded. Of the positive studies approximately 50% showed non-epileptic attacks. Strategies for improving the rate of positive investigations are discussed.

Electroencephalography↗

Identification, capture, and biotelemetry of socially living monkeys.

Remote monitoring of physiologic function using socially living monkeys differs from that using individually housed animals in that access to subjects may be limited. Some logistic aspects of working with socially housed monkeys are reviewed, including identification of individuals and capturing subjects. Methods of remote sampling include hormonal assays of urine and fecal samples, measurement of physical indices as estimates of reproductive status, and the use of telemetry devices to record activity and biopotentials. Key factors in the selection of a telemetry system are discussed. In many cases, remote monitoring may permit assessment of physiologic function without the stress of handling or restraint.

Animal Identification Systems↗

[Development of direct and indirect ambulatory 24-hour blood pressure monitoring].

The direct ambulatory 24-hour blood-pressure monitoring has been applied in two ways. With the so called "Oxford-system", blood pressure is recorded via a cannula in the brachial artery which is connected to a perfusion unit that is worn around the neck, on the front of the chest, with a tape recorder carried in a pouch on the patient's belt. Using the micro-catheter blood-pressure telemetry recording is done in the same way, but transmission of the data to a stationary-receiving unit is managed by telemetry. The usage of the latter method is limited by the weight and complexity of the patient-sited equipment. Compared to the Oxford-system there is the advantage of continuously observing the patients blood-pressure "on-line" during the recording. The invasive character of both methods limits the application to special, scientific investigations. In recent years the indirect recording machines for 24-hour blood-pressure monitoring has been developed further. They are now accurate, easy to apply and simple to work out. Beside the auscultatory way of recording, with or without ECG-gating, the oscillometry recording machines have been improved. There should be automatically-operated intervals with recordings in day-time every 15-20 minutes and during the night every 30 minutes. The recorded data should be analysed by computer, calculating mean values with standard deviations in day-time and night-time separately. Further more, there should be a listing of reading-errors and probably corrected measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Pressure↗