PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Absorbable Implants”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Protein electrostatic self-assembly on poly(DL-lactide) scaffold to promote osteoblast growth.

The development of protein coating on 3D biodegradable scaffold based on electrostatic self-assembly (ESA) to promote osteoblast growth is reported. Poly (ethylenimine) (PEI) was employed to obtain a stable positively charged surface on poly(DL-lactide) (PDL-LA) substrate. An extracellular-matrix (ECM)-like biomacromolecule, gelatin, was chosen as the polyelectrolyte to deposit on the activated PDL-LA substrate via ESA technique. Osteoblast (MC3T3) was then cultured on unmodified and gelatin-modified PDL-LA scaffolds. Osteoblast testing regarding total intracellular protein content, total DNA content, cell activity, and cell morphology on the ECM-like multilayer-modified PDL-LA scaffold showed that osteoblast growth was promoted. It will be easy to replace the gelatin with osteoinductive proteins or other polyelectrolytes to promote specific osteoblast functions. In comparison with conventional coating methods, polyelectrolyte multilayers are easy and stable to prepare. They may be a good choice for the surface modification of complex biomedical devices, especially for the 3D tissue-engineering scaffold. These very flexible systems allow broad medical applications for drug delivery and tissue engineering.

3T3 Cells↗

Maxillary sinus augmentation with Bio-Oss particles: a light, scanning, and transmission electron microscopy study in man.

Biological interactions occurring at the bone-biomaterial interface are critical for long-term clinical success. Bio-Oss is a deproteinized, sterilized bovine bone that has been extensively used in bone regeneration procedures. The aim of the present study was a comparative light, scanning, and electron microscopy evaluation of the interface between Bio-Oss and bone in specimens retrieved after sinus augmentation procedures. Under light microscopy, most of the particles were surrounded by newly formed bone, while in a few cases, at the interface of some particles it was possible to observe marrow spaces and biological fluids. Under scanning electron microscopy, in most cases, the particle perimeter appeared lined by bone that was tightly adherent to the biomaterial surface. Transmission electron microscopy showed that the bone tissue around the biomaterial showed all the phases of the bone healing process. In some areas, randomly organized collagen fibers were present, while in other areas, newly formed compact bone was present. In the first bone lamella collagen fibers contacting the Bio-Oss surface were oriented at 243.73 +/- 7.12 degrees (mean +/- SD), while in the rest of the lamella they were oriented at 288.05 +/- 4.86 degrees (mean +/- SD) with a statistically significant difference of 44.32 degrees (p < 0.001). In the same areas the intensity of gray value was 172.56 +/- 18.15 (mean +/- SD) near the biomaterial surface and 158.71 +/- 21.95 (mean +/- SD) in the other part of the lamella with an unstatistically significant difference of 13.79 (p = 0.071). At the bone-biomaterial interface there was also an electron-dense layer similar to cement lines. This layer had a variable morphology being, in some areas, a thin line, and in other areas, a thick irregular band. The analyses showed that Bio-Oss particles do not interfere with the normal osseous healing process after sinus lift procedures and promote new bone formation. In conclusion, this study serves as a better understanding of the morphologic characteristics of Bio-Oss and its interaction with the surrounding tissues.

Absorbable Implants↗

Strength retention of 70:30 poly(L-lactide-co-D,L-lactide) following real-time aging.

This study evaluated the in vitro strength retention and polymer characteristics of plates and screws made from commercially available 70:30 poly(L-lactide-co-D,L-lactide) over a 2-year time period. Test samples included three routine manufacturing lots each of plates (1.2 mm thick, 41.70 mm long, with 2.5-mm holes), which were machined from compression-molded sheets, and screws (2.4-mm major diameter and 1.86-mm minor diameter), which were manufactured by injection molding. All samples were sterilized by e-beam irradiation prior to in vitro aging following a standard methodology. Mechanical testing and polymer analysis was performed after 0, 6, 13, 26, 39, 52, 65, 78, and 104 weeks. The initial (time zero) tensile strength of the plates averaged 33.2+/-1.9 MPa; the plates retained 100% of this strength at 6 weeks, 84% at 13 weeks, and 34% at 39 weeks. The screws had an initial (time zero) shear strength of 29.8+/-4.2 MPa, and maintained 97% of this strength at 26 weeks and 73% of this strength at 39 weeks. The inherent viscosity and molecular weight (M(w)) at time zero averaged approximately 1.4 dL/g and 165,000 g/mol, respectively, and decreased at similar rates for both the plates and screws. These results demonstrate excellent strength retention of devices fabricated from 70:30 poly(L-lactide-co-D,L-lactide) over time periods exceeding those associated with normal bone healing.

Absorbable Implants↗

Manufacture of porous polymer nerve conduits through a lyophilizing and wire-heating process.

We have developed a method for nerve tissue regeneration using longitudinally oriented channels within biodegradable polymers created by a combined lyophilizing and wire-heating process. This type of cell-adhesive scaffold provides increased area to support and guide extending axons subsequent to nerve injury. Utilizing Ni-Cr wires as mandrels to create channels in scaffold increased safety, effectiveness, and reproducibility. The scaffolds tested were made from different biodegradable polymers, chitosan and poly(D,L-lactide-co-glycolide) (PLGA), because of their availability, ease of processing, low inflammatory response, and approval by the FDA. According to our experimental results, the high permeability and the characteristic porous structure of chitosan proved to be a better material for nerve guidance than PLGA. The scanning electron micrographs revealed that the scaffolds were consistent along the longitudinal axis with channels being distributed evenly throughout the scaffolds. There was no evidence to suggest merging or splitting of individual channels. The diameter of the channels was about 100 mum, similar to the 115 micromameter of the Ni-Cr wire. Regulating the size and quantity of the Ni-Cr wires allow us to control the number and the diameter of the channels. Furthermore, the neutralizing processes significantly influenced the porous structure of chitosan scaffolds. Using weak base (NaHCO(3) 1M) to neutralize chitosan scaffolds made the porous structure more uniform. The innovative method of using Ni-Cr wires as mandrels could be easily tailored to other polymer and solvent systems. The high permeability and the characteristic porous structure of chitosan made it a superior material for nerve tissue engineering. These scaffolds could be useful for guiding regeneration of the peripheral nerve or spinal cord after a transection injury.

Absorbable Implants↗

Mechanical properties and in vitro degradation of bioresorbable fibers and expandable fiber-based stents.

Bioresorbable polymeric support devices (stents) are being developed in order to improve the biocompatibility and drug reservoir capacity of metal stents, as well as to offer a temporary alternative to permanent metallic stents. These temporary devices may be utilized for coronary, urethral, tracheal, and other applications. The present study focuses on the mechanical properties of bioresorbable fibers as well as stents developed from these fibers. Fibers made of poly(L-lactide) (PLLA), polydioxanone (PDS), and poly(glycolide-co-epsilon-caprolactone) (PGACL) were studied in vitro. These fibers combine a relatively high initial strength and modulus together with sufficient ductility and flexibility, and were therefore chosen for use in stents. The effect of degradation on the tensile mechanical properties and morphology of these fibers was examined. The expandable stents developed from these fibers demonstrated excellent initial radial compression strength. The PLLA stents exhibited excellent in vitro degradation resistance and can therefore support body conduits such as blood vessels for prolonged periods of time. PDS and PGACL stents can afford good support for 5 and 2 weeks, respectively, and can therefore be utilized for short-term applications. The degradation resistance of the stents correlates with the profile of mechanical property deterioration of the corresponding bioresorbable fibers.

Absorbable Implants↗

In-patient versus in vitro degradation of P(L/DL)LA and PLGA.

To assess and compare degradation rates, poly(70L-lactide-co-30DL-lactide) [P(L/DL)LA] and poly(85L-lactide-co-15-glycolide) (PLGA) copolymer degradation were studied in patients (maxillofacial region) and in vitro. Five patients of a total of 20 with 85:15 PLGA osteosyntheses, and 15 of a total of 60 with 70:30 P(L/DL)LA osteosyntheses, (10 females and 10 males, 26-55 years; mean, 33 years) underwent explantations after 3, 6, 9, 12, 18, and 24 months. Identical resorbables immersed in physiological buffer solution at 37 degrees C were compared at identical intervals. P(L/DL)LA's initial average molecular weight of 45,000 decreased to 25,000 in patients (and to 21,000 in vitro) after 6 months, and to 8000 in patients after 18 months. PLGA's average molecular weight decreased from 44,600 to 22,000 after 3 months in patients and in vitro, and to 11,000 in patients and 1300 in vitro at 6 months. In-patient and in vitro glass-transition temperatures decreased from approximately 60 degrees C to 50 degrees C over 18 months. Crystallinity in explants was < or = 4% in P(L/DL)LA throughout testing, and 16% and 30% in PLGA at 6 and 12 months, respectively. Both copolymers decomposed reliably in patients: 85:15 PLGA within 12 months and 70:30 P(L/DL)LA within 24 months on average (p < 0.005), leaving only extremely small granules that powder upon finger touch. In vitro rates were significantly faster (p < 0.005). Crystallinity associated with foreign-body reactions was minor and did not inhibit decomposition.

Absorbable Implants↗

Modulation of protein release from biodegradable core-shell structured fibers prepared by coaxial electrospinning.

Biodegradable core-shell structured fibers with poly(epsilon-caprolactone) as shell and bovine serum albumin (BSA)-containing dextran as core were prepared by coaxial electrospinning for incorporation and controlled release of proteins. BSA loading percent in the fibers and its release rate could be conveniently varied by the feed rate of the inner dope during electrospinning. With the increase in the feed rate of the inner dope, there was an associated increase in the loading percent and accelerated release of BSA. Poly(ethylene glycol) (PEG) was added to the shell section of the fibers to further finely modulate the release behavior of BSA. It was revealed that the release rate of BSA increased with the PEG percent in the shell section. By varying the feed rate of the inner dope and PEG content, most of BSA could be released from the core-shell structured fibers within the period of time ranging from 1 week to more than 1 month. The effect of the feed rate of the inner dope and addition of PEG into the shell section on the fiber morphology was also examined by scanning electron microscope.

Absorbable Implants↗

Collapse pressures of bilayered biodegradable stents.

Biodegradable helicoidal stent prototypes made up of layers of poly-L-lactic acid (PLLA) and poly(L-lactic-co-glycolic acid) (PLGA) polymers were fabricated by temperature conditioning the stents at different stages of fabrication. The process incorporated elastic memory, or self-expandability in the stent, which is desirable to minimize stent recoil. The collapse pressures of such stents were studied, with and without in vitro degradation. The effects of thickness and the composition of each layer on the collapse pressure were modeled using the simple series model. Results of the in vitro studies for over 3 months showed that collapse pressure of the stents depended mainly on the degradation and other side-effects brought about by the degradation of different polymer compositions. Generally, the trend is dominated by the thicker of the two layers that were used to form the stents.

Absorbable Implants↗

Evaluation of a bioresorbable polylactide sheet for the reduction of pelvic soft tissue attachments in a porcine animal model.

In an adult porcine model, the effectiveness of a bioresorbable film to minimize soft tissue attachment to the pelvic viscera was evaluated at 4-week and 12-week endpoints. Following a transperitoneal laparotomy through a midline incision, the bladder and uterus were abraded in all animals to promote soft tissue attachment to the viscera. Control animals received no further treatment. The experimental group animals were treated with bioresorbable polylactide (PLa) sheets, 0.02 mm thick, one between the bladder and the abdominal wall, and a second sheet between the bladder and the uterus. Quantitative assessment of the severity and location of soft tissue attachments, and qualitative histologic assessment were performed at 4 and 12 weeks post-operatively. Statistically significant differences in the quantitative soft tissue attachment scores were observed in comparing the PLa film treated animals versus the control animals, at both the 4-week and 12-week time points. In the control animals, the formation of numerous thick fibrous bands was observed at both time points. Histology revealed no adverse reaction to the bioresorbable PLa barrier film. The bioresorbable PLa sheet provided an effective barrier between adjacent anatomical structures and minimized soft tissue attachments to the device when in contact with the viscera as compared to the control groups. Surgical dissection planes between the abdominal wall and adjacent soft tissues were maintained with the use of the PLa sheet at both time points.

Absorbable Implants↗

Biodegradation process of alpha-TCP particles and new bone formation in a rabbit cranial defect model.

The purpose of the present study was to observe the biodegradation process of pure alpha-tricalcium phosphate (alpha-TCP) particles and to determine the efficacy of alpha-TCP as a space maintainer in a bone defect. We used 14 rabbits and prepared two cranial bone defects in each rabbit. One defect was left empty as a control, whereas the other was filled with alpha-TCP particles about 300 mum in diameter. Animals were sacrificed at 1 week, 4 weeks, and 8 weeks. The cranial bone was then embedded either in paraffin wax for the preparation of decalcified specimens, or in polyester resin for the preparation of nondecalcified specimens. All specimens were evaluated histologically and histomorphometrically. As a consequence of the degradation of alpha-TCP, a "reticulate structure" appeared in the particles at 1 week and new bone was observed in this structure at 8 weeks. The amount of new bone between the control and experimental groups was not significantly different at any of the time points. However, in the experimental group, new bone at the surface of alpha-TCP was evident even in the center of the defect whereas fibrous connective tissue was dominant in the control group. These results indicate that alpha-TCP is a degradable osteoconductive material that is able to act as a space maintainer for bone regeneration when applied to a bone defect. While there was no significant difference in total bone formation between the experimental and negative control groups, the space-maintaining and osteoconductive properties of the particles may result in more complete bone formation in longer-term studies.

Absorbable Implants↗

Improving the elasticity and cytophilicity of biodegradable polyurethane by changing chain extender.

Two types of biodegradable polyurethanes (PUs) were synthesized from methylene di-p-phenyl-diisocyanate (MDI), polycaprolactone diol (PCL-diol), and chain extenders of either butanediol (BD) or 2,2'-(methylimino)diethanol (MIDE). The effects of two types of chain extenders on the degradation, mechanical properties, hydrophilicity, and cytophilicity of PUs were evaluated. In vitro degradation studies showed that PU containing MIDE has a higher degradation rate than PU synthesized using BD as a chain extender. Mechanical testing on dry and wet samples demonstrated that PU containing MIDE has a much higher elongation in the elastic region than PU containing BD. PU containing MIDE is more hydrophilic and retains more liquid during in vitro culture. Furthermore, preliminary cytocompatibility studies showed that both types of degradable PU are nontoxic, and fibroblasts adhere better and proliferate faster on MIDE containing PU than BD containing PU. To compare the cytocompatibility and degradation behaviors of the synthesized PU with existing FDA approved biocompatible material, polylactide (PLA), with a similar degradation rate, was used as negative control. Two types of PU were shown to have similar cytocompatibility and degradation behaviors as those of the PLA material. To verify the effectiveness of the cytotoxicity assay, latex was used as a positive control. Latex samples showed toxicity to cultured cells as expected. In conclusion, by changing the type of chain extender used during the synthesis of degradable PUs, the degradation rate, mechanical properties, hydrophilicity, and cytophilicity can be adjusted for different tissue engineering applications.

Absorbable Implants↗

The role of biological extracellular matrix scaffolds in vascularized three-dimensional tissue growth in vivo.

An in vivo murine vascularized chamber model has been shown to generate spontaneous angiogenesis and new tissue formation. This experiment aimed to assess the effects of common biological scaffolds on tissue growth in this model. Either laminin-1, type I collagen, fibrin glue, hyaluronan, or sea sponge was inserted into silicone chambers containing the epigastric artery and vein, one end was sealed with adipose tissue and the other with bone wax, then incubated subcutaneously. After 2, 4, or 6 weeks, tissue from chambers containing collagen I, fibrin glue, hyaluronan, or no added scaffold (control) had small amounts of vascularized connective tissue. Chambers containing sea sponge had moderate connective tissue growth together with a mild "foreign body" inflammatory response. Chambers containing laminin-1, at a concentration 10-fold lower than its concentration in Matrigel, resulted in a moderate adipogenic response. In summary, (1) biological hydrogels are resorbed and gradually replaced by vascularized connective tissue; (2) sponge-like matrices with large pores support connective tissue growth within the pores and become encapsulated with granulation tissue; (3) laminin-containing scaffolds facilitate adipogenesis. It is concluded that the nature and chemical composition of the scaffold exerts a significant influence on the amount and type of tissue generated in this in vivo chamber model.

Absorbable Implants↗

Histological and histomorphometrical comparative study of the degradation and osteoconductive characteristics of alpha- and beta-tricalcium phosphate in block grafts.

The purpose of the present study was to compare alpha- and beta-tricalcium phosphate (TCP) as bone graft material for augmenting highly resorbed alveolar ridges. The cranial bones of 15 rabbits were used. Three titanium chambers filled with porous blocks of alpha-TCP, beta-TCP, or blood clots were placed in each slit. The two TCP blocks had similar inner/outer structures and purities. Animals were sacrificed after 2, 4, and 8 weeks. Specimens were embedded in polyester resin as nondecalcified specimens, and evaluated both histologically and histomorphometrically. In both TCP groups, blocks had hardly degraded at 2 weeks while in the alpha-TCP group, the block had notably started degrading after 4 weeks. In the beta-TCP group, degradation began at 4 weeks and this degradation had increased just slightly after 8 weeks. The alpha-TCP block degraded significantly more than the beta-TCP block. Residual alpha-TCP particles surrounded by newly formed bone decreased over time, and both particles and newly formed bone were simultaneously absorbed by osteoclast-like cells. These observations suggest that residual alpha-TCP particles surrounded by newly formed bone may disappear progressively from bone and could be incorporated into the bone remodeling cycle in combination with newly formed bone.

Absorbable Implants↗

Use of isolated mature osteoblasts in abundance acts as desired-shaped bone regeneration in combination with a modified poly-DL-lactic-co-glycolic acid (PLGA)-collagen sponge.

Controlled regeneration of bone or cartilage has recently begun to facilitate a host of novel clinical treatments. An osteoblast line, which we isolated is able to form new bone matrix in vivo within 2 days and exhibits a mature osteoblast phenotype both in vitro and in vivo. Using these cells, we show that cuboidal bones can be generated into a predesigned shaped-bone with high-density bone trabeculae when used in combination with a modified poly-DL-lactic-co-glycolic acid (PLGA)-collagen sponge. PLGA coated with collagen gel serves as a good scaffold for osteoblasts. These results indicate that mature osteoblasts, in combination with a scaffold such as PLGA-collagen sponge, show promise for use in a custom-shaped bone regeneration tool for both basic research into osteogenesis and for development of therapeutic applications.

Absorbable Implants↗

A biodegradable delivery system for antibiotics and recombinant human bone morphogenetic protein-2: A potential treatment for infected bone defects.

To produce an osteogenic and bacteriocidal biomaterial for the treatment of infected nonunions or bone defects, a synthetic degradable block copolymer of poly-D,L-lactic acid segments with randomly inserted p-dioxanone and polyethylene glycol (PLA-DX-PEG) segments was mixed with recombinant human BMP-2 (rhBMP-2) and antibiotics at high concentration. We then examined the in vitro elution profile of an antibiotic (teicoplanin) from the polymer, the effects of antibiotics on the bone-inducing capacity of rhBMP-2 or on ectopic new bone formation induced by the rhBMP, and the ability of the polymer to repair bone in a rat cranial defect model. Approximately 40% of teicoplanin was released within the first 24 h, with the remaining amount released steadily over 21 days with no loss of antibacterial activity. The polymer had disappeared by degradation in the phosphate buffered saline (pH 7.4) at the end of the incubation period. The in vivo performance of pellets with antibiotics and rhBMP-2 revealed no significant change in bone yield within the ossicles after 3 weeks. Also, antibiotics had no inhibitory effect on the ability of rhBMP2 to repair cranial defects. Indeed, when the defect was filled by a polymer disc loaded with rhBMP-2 with or without teicoplanin, the defect was repaired by new bone, and normal anatomy was restored within 6 weeks. In conclusion, the PLA/DX/PEG polymer appears to work as effectively for antibiotics as it does for rhBMP-2. Additionally, the biological activity of rhBMP-2 was retained irrespective of the presence of antibiotics.

Absorbable Implants↗

Does a tensioning device pinned to the tibia improve knee anterior-posterior load-displacement compared to manual tensioning of the graft following anterior cruciate ligament reconstruction? A cadaveric study of two tibial fixation devices.

Devices that are pinned to the tibia to tension an anterior cruciate ligament (ACL) graft produce joint reaction loads that in turn can affect the maintenance of graft initial tension after tibial fixation and hence knee anterior-posterior (AP) load-displacement. However, the effect of these devices on AP load-displacement is unknown. Our objectives were to determine whether tensioning by device versus tensioning by hand causes differences in AP load-displacement and intraarticular graft tension for two commonly used tibial fixation devices: a bioresorbable interference screw and a WasherLoc. AP load-displacement and intraarticular graft tension were measured in 20 cadaveric knees using a custom arthrometer. An initial tension of 110 N was applied to a double-looped tendon graft with the knee at extension using a tensioning device pinned to the tibia and a simulated method of tensioning by hand. After inserting the tibial fixation device, the 134 N anterior limit (i.e., anterior position of the tibia with respect to the femur with a 134 N anterior force applied to the tibia) and 0 N posterior limit (i.e., AP position of the tibia relative to the femur with a 0 N force applied to the tibia) were measured with the knee in 25 degrees flexion. Intraarticular graft tension was measured at extension. These limits and intraarticular graft tension were also measured after cyclically loading the knee 300 times. Compared to a simulated method of tensioning by hand, tensioning with a device pinned to the tibia did not decrease the 134 N anterior limit and did not cause posterior tibial translation. However, intraarticular graft tension was maintained better with a tensioning device pinned to the tibia for the Washerloc, but not the interference screw. For two commonly used tibial fixation devices, a tensioning device pinned to the tibia does not improve AP load-displacement at 25 degrees flexion over tensioning by hand when the graft is tensioned at full extension, but does improve the maintenance of intraarticular graft tension for the Washerloc.

Absorbable Implants↗

Mechanical and radiological assessment of the influence of rhTGFbeta-3 on bone regeneration in a segmental defect in the ovine tibia: pilot study.

Limitations in the use of autologous bone graft, which is the gold standard therapy in bone defect healing, drive the search for alternative treatments. In this study the influence of rhTGFbeta-3 on mechanical and radiological parameters of a healing bone defect in the sheep tibia was assessed. In the sheep, an 18-mm long osteoperiosteal defect in the tibia was treated by rhTGFbeta-3 seeded on a poly(L/DL-lactide) carrier (n = 4). In a second group (n = 4), the defect was treated by the carrier only, in a third group (n = 4) by autologous cancellous bone graft, and in a fourth group (n = 2) the defect remained blank. The healing process of the defect was assessed by weekly in vivo stiffness measurements and radiology as well as by quantitative computed tomographic assessment of bone mineral density (BMD) every 4 weeks. The duration of the experiment was 12 weeks under loading conditions. In the bone graft group, a marginally significant higher increase in stiffness was observed than in the PLA/rhTGFbeta-3 group (p = 0.06) and a significantly higher increase than in the PLA-only group (p = 0.03). The radiographic as well as the computed tomographic evaluation yielded significant differences between the groups (p = 0.03), indicating the bone graft treatment (bone/per area, 83%; BMD, 0.57 g/cm(3)) performing better than the PLA/rhTGFbeta-3 (38%; 0.23 g/cm(3)) and the PLA-only treatment (2.5%; 0.09 g/cm(3)), respectively. Regarding the mechanical and radiological parameters assessed in this study, we conclude that rhTGFbeta-3 has a promoting effect on bone regeneration. However, under the conditions of this study, this effect does not reach the potential of autologous cancellous bone graft transplantation.

Absorbable Implants↗

Lumbar body fusion with a bioresorbable cage in a goat model is delayed by the use of a carboxymethylcellulose-stabilized collagenous rhOP-1 device.

The purpose of this study was to evaluate the efficacy of recombinant human osteogenic protein-1 (rhOP-1) with a carboxymethylcellulose-stabilized collagenous carrier as a bone graft substitute for instrumented lumbar spinal fusion in an established goat model. Twenty goats received a resorbable poly-L-lactic acid (PLLA) interbody cage packed with either rhOP-1 and its carrier or autologous bone graft. The carrier material was bovine collagen type-1 stabilized with carboxymethylcellulose. The fusion segments were retrieved at 3 or 6 months postimplantation and evaluated by radiographic and histologic analyses. The rhOP-1 graft substitute, used in combination with the resorbable PLLA cage, showed inferior results as compared to autologous bone graft in the goat lumbar fusion model. Whereas four out of five segments from the autograft group were fused after 6 months, none of the four segments receiving the rhOP-1 graft substitute were fused at this time point. Bone ingrowth into the cage was delayed or absent in the experimental group, whereas all autograft specimens showed advanced bone ingrowth (3 months) or fusion (6 months). We suggest that the fusion process was inhibited, because cells were unable to penetrate the rhOP-1 graft material. This led to delayed bone formation and in some cases inadequate tissue formation.

Absorbable Implants↗